prismapor n 48i
Transcrição
prismapor n 48i
PRISMAPOR LDA R ANT. FERREIRA DA SILVA 67 4475-844 MAIA TEL 229825273 FAX 229825266 www.prismapor.pt EDITORIAL Dear Readers At the beginning of each year there is always an uncertainty how to go forward. In our company the level of incoming orders is reasonable, about 2.3 million euros, but there is a number of uncertainties, including lack of investment and the need to solve the problem of money transfer from Angola , all of this aggravated by the global finance crisis that makes us believe that 2016 will be even more difficult that the previous year , nevertheless we are prepared for the challenge. In fact I think that only a coordinated public investment with some structural reforms is likely to put end to this situation in which even the interest rates are negative. On the reverse side you will find the certificate of Assembly Manufacturer (Panel Builder) from Schneider Electrical Portugal for 2016 for the Functional System Prisma Plus type G & P up to 4000A in compliance with the standard IEC 61439-1 & 2 proceeding to the routine tests and report in accordance with Schneider Electric Manuals. In our site please download the certificate, (also in French) Best Regards A Pedrosa Schneider’s Panel Builder N. º48 FEBRUARY 2016 INSULATION CLASSES SWITCHBOARDS (IX) IN Because it is quite relevant we are going, in future issues of the Newsletter, disclose the document from Direcção Geral de Energia e Geologia (December 2012) and prepared by Technical Committee for Electro technical Standardization -CTE64- Insulation Classes in Switchboards (answers to frequently asked questions) 13. In a class I "QE"(Entry Switchboard) with a DR (Residual Device) in the incoming, could be considerer class II "QE" ? No. The protection with DR does not make the "QE" switchboard class I in a Class II switchboard. However, the protection against indirect contact could be performed, among other measures, by protection with DR or a class II insulation. See section 413.1 & 413.2 of the RTIEBT 14. The Technical Rules (RTIEBT) requires the use of "QE" class II in the electrical system TT? No. In the TT system the "QE" must be only be class II insulation if there is not protection against indirect contact made by a DR in the incoming of the switchboard. See section 531.2.4 & 801.5.9 of the RTIEBT End of the document from DGEG prepared by Technical Committee for electro technical standardization -CTE-64 Insulation Class in switchboards (answers to frequently asked questions) PSC PRISMAPLUS ? CALL PRISMAPOR !!! TEL: +351229825273 FAX+351229825266 www.prismapor.pt
Documentos relacionados
prismapor n 41i
Electric Portugal for 2014 of the Functional system Prisma Plus G & P up to 4000A in compliance with the requirements specified in IEC
Leia mais