Industrial Hydraulic Valves Catalog HY14-2502/US

Transcrição

Industrial Hydraulic Valves Catalog HY14-2502/US
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Technical Information
General Description
The D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature
solenoid controlled, 3 or 4-way valves. They are
available in 2 or 3-position and conform to NFPA’s D03/
CETOP 3 mounting patterns.
B
AB
A
PT
Features
•
•
•
•
•
•
Mechanically tunable soft shift
•
•
•
•
•
•
•
Internally ground
Proportional spools, 21 standard spool styles available
Repairable override
DC surge suppression
Nine electrical connection options
AC & DC lights available (CSA approval for
solenoids and lights)
Easy access mounting bolts
Waterproof (NEMA 4 rated)
Specifications
Explosion proof
Mounting Pattern
Mounting
Interface
CSA approved and U.L. recognized available
No tools required for coil removal
AC rectified coils
Response Time*
Maximum
Pressure
Nominal response time (milliseconds) at 345 Bar
(5000 PSI) is 32 L/M (8.5 GPM).
Solenoid Type
Pull-In
Drop-Out
AC
DC 8 Watt
or 10 Watt
DC 30 Watt
13
61
20
22
51
21
NFPA D03, CETOP 3; NG 6
DIN 24340-A6
ISO 4401-AB-03-4-A
CETOP R35H 4.2-4-03,
NFPA D03
P, A, B
345 Bar (5000 PSI) Standard
CSA
276 Bar (4000 PSI)
Tank:
103 Bar (1500 PSI) Standard
207 Bar (3000 PSI) Optional
with H, FH, G, LG
CSA
103 Bar (1500 PSI)
* For soft shift, see ordering code X-number.
2502-A1.p65, dd
A17
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
A
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Ordering Information
Standard Valves
A
D
1V
Directional
Control Valve
Basic Valve
Actuator#
Spool
Style
Seal
Solenoid
Voltage
2MD
NFPA D03
CETOP 3
DIN NG6
Code
W
HW
Code
N
V
Description
Solenoid, Wet Pin,
Screw-in
Reversed Wiring
E*
# Valve schematic symbols are per NFPA/ANSI
standards, providing flow P to A when
energizing solenoid A. Note operators
reverse sides for #008 and #009 spools. See
installation information for details. To
configure per DIN standards (A coil over
A port, B coil over B port) code valves as
D1VHW***.
Code
Symbol
A
Code
B
001
Code
A
D
G
J
K
L
N
Q
R
T
U
Y
Z
Description
Nitrile
Fluorocarbon
EPR
* Contact HVD for
availability.
Description
24/50 VAC
120 VDC
198 VDC
24 VDC
12 VDC
6 VDC
220/50 VAC
100/60 VAC
24/60 VAC
240/60 - 220/50 VAC
98 VDC
120/60 - 110/50 VAC
250 VDC
Symbol
A
B
014
P
T
P
T
A
B
A
B
002
015
P
T
A
B
Code
Symbol
b
B*
P
A
Description
T
B
b
003
016
P
T
P
T
A
B
A
B
004
b
P
T
P
T
A
B
A
B
D†
P
T
A
B
A
006
T
B
E
T
P
T
A
B
A
B
007
F
P
T
P
T
A
B
A
B
P
T
P
T
A
B
A
B
010
P
T
P
T
B
A
B
P
T
P
T
011
082
M
P
T
a
A
B
P
T
a
b
A
B
P
T
b
A
B
P
T
A
B
P
T
A
B
a
a
2 position, spring centered and P to A
081
A
T
2 position, spring offset P to B
030**
K
P
2 position, spring offset P to A and centered
026*
H*
B
2 position, spring centered and P to B
022
P
A
2 position, detent, P to A and B to T
021
P
B
3 position, spring centered
020*
005
008*,
009**
C
A
2 position, spring offset P to A
P
T
A
B
P
T
a
2 position, spring offset P to B and centered
* 020, 026 and 030 spools only.
† 020 and 030 spools only.
* 008, 020 & 026 spools have closed crossover.
** 009 & 030 spool have open crossover.
See Universal Spool Chart for other spool options.
2502-A1.p65, dd
A18
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Ordering Information
Standard Valves
A
Solenoid
Connection
Code
C
D
E
G
H*†
J**†
L
M**†
P
S
W*
Coil
Options
Tube
Options
Manual
Override
Options
Electrical
Options
Description
Conduit Box
Metric Plug (M12X1),
DESINA
Explosion Proof
Plug-In
Single Spade
Deutsch (DT06-25)
Dual Screw Lug
Metri-Pack (150)
DIN with Plug
Double Spade
DIN w/o Plug
Code
Omit
S2*
S3*
S4*
S5*
S6*
SN*
I7
I8
* Not available with lights.
** See valve variations for others.
† DC only.
Code
Omit
D
E
F**
C†
L***
O
U
X*
Description
High Watt
Explosion Proof,
EEXD ATEX
Explosion Proof,
EEXME ATEX
Low Watt
CSA Hazardous
Location
8 Watt
Explosion Proof,
MSHA
Explosion Proof,
UL/CSA
No Coils
Shift
Response
and
Indication
Approvals
Design
Series
NOTE:
Not required
when ordering.
Description
Standard Response
Soft Shift, 0.020" Orifice
Soft Shift, 0.030" Orifice
Soft Shift, 0.040" Orifice
Soft Shift, 0.050" Orifice
Soft Shift, 0.060" Orifice
Soft Shift, No Orifice
Monitor Switch Direct
Op. End Stroke
Monitor Switch
Direct Op. Start Stroke
* Not available with 8 watt.
Code
Omit
J
B
Code
Omit
P
T
R
W
Description
No Options
Diode Surge
Suppressor
Rectified Coil
Description
Standard
Extended with Boot
None
Repairable
Waterproof Override Protection
See solenoid voltage code
to specify proper tube.
** AC only.
*** DC/AC Rectified only.
† Applicable to conduit box
and plug-in style only.
Code
Omit
4*
K
Description
Standard Valve
C.S.A. Approved
UL Recognition
* Not available with high
pressure tube.
Code
5
6
7A
56
7B
*
1A
1B
1C
1D
Code
Omit
H
M
G
Valve
Variations
Description
Low Pressure, AC only
High Pressure, AC only
Low Pressure, DC-WI only
High Pressure, DC-WI only
4D
4E
Description
Signal Lights
Manaplug - Brad Harrison Mini
Manaplug - Brad Harrison
(12x1) Micro
Manaplug (Mini) with Lights
Manaplug (Micro) with Lights
(D1 only)
Manaplug (Mini) Single Sol. 5-pin
Manaplug (Micro) Single Sol. 5-pin
Manaplug (Mini) Single Sol. 5-pin,
with Lights
Manaplug (Micro) Single Sol. 5-pin,
with Lights
Twist & Lock Override (Old 5426)
Push Manual Override (Old x5450)
Valve Weight:
Single Solenoid
Double Solenoid
Standard Bolt Kit:
Metric Bolt Kit:
2502-A1.p65, dd
A19
1.36 kg (3.0 lbs.)
1.6 kg (3.5 lbs.)
BK209
BKM209
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Technical Information
Solenoid Ratings
A
Insulation System
Allowable Deviation
from rated voltage
Armature
CSA File Number
Environmental
Capability
Explosion Proof Solenoid Ratings*
Class F
-10% to +15% for DC and AC rectified coils
-5% to +5% for AC Coils
Wet pin type
LR60407
DC Solenoids are rated at NEMA 4 (IP67)
or better when properly wired and installed.
Contact HVD for AC coil applications.
U.L. & CSA (EU)
M.S.H.A. (EO)
ATEX (ED)
CSA Hazardous Location
Class I, Div 1 & 2, Groups C & D
Class II, Div 1 & 2, Groups E, F & G
As defined by the NEC
Complies with 30CFR, Part 18
Complies with ATEX requirements for:
Exd, Group IIB; EN50014: 1999+ Amds.
1 & 2, EN50018: 2000
Class II, Groups E, F & G
* Allowable Voltage Deviation +/- 10%
Note that AC coils are single frequency only.
Code
Voltage Code Power Code
A
D
L
Voltage
24/50 VAC, High Watt
120 VDC
G
L
24/60 VAC, High Watt
24/50 VAC, High Watt
198 VDC
J
L
24 VDC
K
L
12 VDC
L
L
6 VDC
M
L
9 VDC
E
P
R
S
T
U
X
Y
Z
Specials
110/50 VAC
24/60 VAC, High Watt
24/60 VAC, Low Watt
F
***Specials*** SEE BELOW
240/60 VAC, High Watt
220/50 VAC, High Watt
240/60 VAC, Low Watt
F
220/50 VAC, Low Watt
F
98 VDC
L
16 VDC
L
120/60 VAC, High Watt
110/50 VAC, High Watt
120/60 VAC, Low Watt
F
110/50 VAC, Low Watt
F
120/60 VAC, 10 Watt
L*B
110/50 VAC, 10 Watt
L*B
120/60 VAC, High Pressure
*H
110/50 VAC, High Pressure
*H
250 VDC
L
S
Explosion Proof Solenoids
R
T
N
Y
P
Q
K
J
D
Z
In Rush Amps
In Rush Amps
Amperage
D1VW VA @ 3MM
7.00 Amps
168 VA
N/A
N/A
N/A
N/A
6.00 Amps
144 VA
7.00 Amps
168 VA
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8.00 Amps
6.67 Amps
192 VA
160 VA
0.77 Amps
0.82 Amps
0.70 Amps
0.75 Amps
N/A
N/A
1.55 Amps
1.65 Amps
1.40 Amps
1.50 Amps
0.63 Amps
0.73 Amps
1.40 Amps
1.48 Amps
N/A
N/A
185 VA
180 VA
168 VA
165 VA
N/A
N/A
186 VA
182 VA
168 VA
165 VA
83 VA
79 VA
168 VA
163 VA
N/A
N/A
Holding Amps Watts
Resistance
D1VW
D1VW
D1VW
2.65 Amps
28 W
1.67 ohm(s)
0.09 Amps
10 W 1584.00 ohm(s)
0.26 Amps
30 W 528.00 ohm(s)
1.85 Amps
20 W
1.67 ohm(s)
2.65 Amps
28 W
1.67 ohm(s)
0.05 Amps
10 W 3920.40 ohm(s)
0.15 Amps
30 W 1306.80 ohm(s)
0.44 Amps
10 W
51.89 ohm(s)
1.32 Amps
30 W
17.27 ohm(s)
0.88 Amps
10 W
12.97 ohm(s)
2.64 Amps
30 W
4.32 ohm(s)
1.67 Amps
10 W
3.59 ohm(s)
5.00 Amps
30 W
1.20 ohm(s)
1.11 Amps
10 W
8.12 ohm(s)
3.35 Amps
30 W
2.67 ohm(s)
0.38 Amps
19 W 135.00 ohm(s)
2.70 Amps
27 W
1.40 ohm(s)
2.20 Amps
23 W
1.52 ohm(s)
0.26 Amps
0.31 Amps
0.22 Amps
0.26 Amps
0.10 Amps
0.63 Amps
0.49 Amps
0.58 Amps
0.42 Amps
0.50 Amps
0.18 Amps
0.20 Amps
0.50 Amps
0.60 Amps
0.04 Amps
0.13 Amps
25 W 134.50 ohm(s)
27 W 134.50 ohm(s)
21 W 145.00 ohm(s)
23 W 145.00 ohm(s)
10 W 960.00 ohm(s)
10 W
25.60 ohm(s)
25 W
33.70 ohm(s)
27 W
33.70 ohm(s)
21 W
36.50 ohm(s)
23 W
36.50 ohm(s)
10 W
75.00 ohm(s)
10 W
75.00 ohm(s)
26 W
36.50 ohm(s)
28 W
36.50 ohm(s)
10 W 6875.00 ohm(s)
30 W 1889.64 ohm(s)
Other voltages/frequencies may be available Contact HVD for more information
24/60 VAC
240/60 VAC
220/50 VAC
120/60 VAC
110/50 VAC
100/60 VAC
12 VDC
24 VDC
120 VDC
250 VDC
7.63 Amps
0.76 Amps
0.77 Amps
1.60 Amps
1.47 Amps
1.90 Amps
N/A
N/A
N/A
N/A
183 VA
183 VA
169 VA
192 VA
162 VA
192 VA
N/A
N/A
N/A
N/A
2.85 Amps
0.29 Amps
0.31 Amps
0.58 Amps
0.57 Amps
0.70 Amps
2.75 Amps
1.38 Amps
0.28 Amps
0.13 Amps
27 W
1.99 ohm(s)
27 W
1.34 ohm(s)
27 W
1.38 ohm(s)
27 W
33.50 ohm(s)
27 W
34.70 ohm(s)
27 W
38.60 ohm(s)
33 W
4.36 ohm(s)
33 W
17.33 ohm(s)
33 W 420.92 ohm(s)
33 W 1952.66 ohm(s)
2502-A1.p65, dd
A20
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
Plug-In Box, Double DC Solenoid
A
49.6
(1.95)
44.9
(1.77)
87.8
(3.46)
15.5
(0.61)
54.3 Min. Coil
(2.14) Removal
1/2 NPTF Thd.
Both Ends
143.7
(5.66)
24.8
(0.98)
93.2
(3.67)
66.0
(2.60)
50.0
(1.97)
23.8
(0.94)
244.4
(9.62)
46.0
(1.81)
Manual
Override
Plug-In Box, Single DC Solenoid
49.6
(1.95)
44.9
(1.77)
24.8
(0.98)
15.5
(0.61)
87.8
(3.46)
1/2 NPTF Thd.
Both Ends
93.2
(3.67)
66.0
(2.60)
54.3
(2.14)
Min. Coil
Removal
188.5
(7.42)
50.0
(1.97)
23.8
(0.94)
46.0
(1.81)
2502-A1.p65, dd
A21
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
A
Hirschmann, Double DC Solenoid
46.0
(1.81)
72.6
(2.86)
12.0
(0.47)
Min. Connector
Removal
115.4
(4.54)
54.3 (2.14)
Min. Coil
Removal
25.3
(1.00)
142.1
(5.59)
15.5
(0.61)
23.0
(0.91)
77.6
(3.06)
66.3
(2.61)
50.0
(1.97)
23.8
(0.94)
244.4
(9.62)
Manual
Override
Hirschmann, Single DC Solenoid
46.0
(1.81)
23.0
(0.91)
15.5
(0.61)
25.3
(1.00)
77.6
(3.06)
54.3
(2.14)
Min. Coil
Removal
100.8
(3.97)
72.6
(2.86)
12.0 (0.47) Min.
Conn. Removal
66.3
(2.61)
50.0
(1.97)
23.8
(0.94)
168.3
(6.63)
Manual
Override
2502-A1.p65, dd
A22
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
Conduit Box, Double AC Solenoid
79.9
(3.15)
36.8
(1.45)
A
126.8
(5.00)
42.75 (1.68) Min.
Coil Removal
½ NPTF Thread
Both Ends
49.5
(1.95)
24.8
(0.98)
15.5
(0.61)
3.0
(0.19)
94.6
(3.72)
66.0
(2.60)
50.0
(1.97)
23.8
(0.94)
See Note
210.7
(8.30)
Note: 22.0 mm (.87”) from bottom of bolt
hole counterbore to bottom of valve.
46.0
(1.81)
Manual Override
Conduit Box, Single AC Solenoid
49.5
(1.95)
24.8
(0.98)
42.75 (1.68) Min.
Coil Removal
84.0
(3.31)
36.8
(1.45)
½ NPTF Thread
Both Ends
15.5
(0.61)
3.0
(0.19)
94.6
(3.72)
66.0
(2.60)
50.0
(1.97)
23.8
(0.94)
163.7
(6.44)
46.0
(1.81)
Manual Override
2502-A1.p65, dd
A23
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
A
Conduit Box, Double AC Solenoid
with Variation 6 (Manaplug) & Variation P (Extended Manual Override)
42.8 (1.69) Min.
Coil Removal
126.8
(4.99)
95.7
(3.77)
36.8
(1.45)
Connector
NFPA T3.5.29
25.4 (1.00) Hex
49.5 (1.95)
24.8
(0.98)
15.5
(0.61)
3.0
(0.19)
94.6
(3.72)
Extended
Manual
Override
66.0
(2.60)
50.0
(1.97)
23.8
(0.94)
225.0
(8.86)
Manual
Override
46.0
(1.81)
61.2 (2.41) Minimum Coil Removal
Conduit Box, Double DC & AC Rectified Solenoids
with Variation 6 (Manaplug) & Variation P (Extended Manual Override)
142.1 (5.59)
95.7 (3.77)
79.9 (3.15)
36.8
(1.45)
54.3 (2.14)
Min. Coil
Removal
Connector
per NFPA
T3.5.29
25.4 (1.00)
Hex
49.5 (1.95)
24.8
(0.98)
15.5
(0.61)
3.0
(0.19)
94.6
(3.72)
Extended
Manual
Override
66.0
(2.60)
50.0
(1.97)
23.8
(0.94)
72.7 (2.86) Min. Coil Removal
46.0
(1.81)
255.4
(10.01)
Manual
Override
2502-A1.p65, dd
A24
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
Conduit Box, Double AC Solenoid
A
with Variation R (Repairable Override)
49.5
(1.95)
79.9
(3.15)
36.8
(1.45)
138.1
(5.44)
54.8 (2.16) Min.
Coil Removal
½ NPTF Thread
Both Ends
15.5
(0.61)
3.0
(0.19)
24.8
(0.98)
94.6
(3.72)
66.0
(2.60)
50.0
(1.97)
23.8
(0.94)
46.0
(1.81)
233.3
(9.19)
Manual
Override
Conduit Box, Double DC Solenoid
with Variation R (Repairable Override)
49.6
(1.95)
44.9
(1.77)
87.8
(3.46)
66.3 (2.61)
Min. Coil
Removal
1/2 NPTF Thd.
Both Ends
155.0
(6.10)
15.5
(0.61)
24.8
(0.98)
93.2
(3.67)
66.0
(2.60)
267.0
(10.51)
50.0
(1.97)
23.8
(0.94)
46.0
(1.81)
Manual
Override
2502-A1.p65, dd
A25
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
A
DESINA, Double DC Solenoid
48.0
(1.89)
90.7
(3.57)
142.1
(5.59)
54.3 (2.14)
Min. Coil
Removal
15.5
(0.61)
70.3
(2.77)
50.8
(2.00)
23.8
(0.94)
46.0
(1.81)
Manual Override
242.4
(9.54)
DESINA, Single DC Solenoid
90.7
(3.57)
142.1
(5.59)
543 (2.14)
Min. Coil
Removal
15.5
(0.61)
70.3
(2.77)
50.8
(2.00)
23.8
(0.94)
167.3
(6.59)
46.0
(1.81)
Manual Override
2502-A1.p65, dd
A26
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
Explosion Proof U.L. & C.S.A., Double Solenoid
163.7
(6.44)
60.4
(2.38)
A
18 Inch Lead
Wires Standard
1/2" NPT
94.4
(3.72)
15.1 (0.61)
130.8
(5.15)
7.5 (0.30)
304.4
(11.98)
46.0
(1.81)
73.0 (2.87)
Explosion Proof M.S.H.A., Double Solenoid
3/4-20 UNF
Thd.
163.7
(6.44)
60.4
(2.38)
3/4-20 UNF
Thd.
38.0 (1.50)
113.0
(4.45)
130.8
(5.15)
15.51 (0.61)
7.5 (0.30)
304.4
(6.44)
46.0
(1.81)
73.0 (2.87)
Explosion Proof ATEX, Double Solenoid
74.7 (2.94)
69.9 (2.75)
19.4
(0.76)
M20 x 1.5-6H Thd.
15.5
(0.61)
131.7
(5.19)
100.9
(3.97)
100.6
(3.96)
42.8
(1.69)
7.5 (0.30)
46.0 (1.81)
141.0 (5.55)
324.7 (12.78)
73.5 (2.89)
2502-A1.p65, dd
A27
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
A
Conduit Box, Single DC Solenoid
with Variation I7 (Monitor Switch) & Variation P (Extended Manual Override)
B
72.7
(2.86)
Min.Coil Removal
49.5
(1.95)
15.5
(0.61)
3.0
(0.12)
115.1
(4.53)
12.0 (0.47) Min.
Conn. Removal
24.8
(0.98)
94.6
(3.72)
81.9
(3.22)
50.0
(1.97)
70.6
(2.78)
Extended
Manual
Override
23.8
(0.94)
46.0
(1.81)
274.9
(10.82)
Monitor Switch
(valve variation I7)
Block Diagram
Pin 1
(Input 24VDC)
Inductor
This feature provides for electrical confirmation of the
spool shift. This can be used in safety circuits, to assure
proper sequencing, etc.
Pin 2
(Output – Normally Open)
Regulator
Pin 3
(Output – Normally Closed)
Switch Data
Inductive switch requiring +18-42 volt input. Outputs A
and B are opposite; one at “0” voltage, the other at input
voltage. During switching, A and B outputs reverse.
Provides 0.4A switching current.
Pin 4
(Ground Terminal)
(Extended, or Energized Position)
For repetitive switch power-up conditions, please consult
factory.
2502-A1.p65, dd
A28
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Directional Control Valves
Series D1VW
Catalog HY14-2502/US
Accessories
Conduit Box
Signal Lights
(connection option G & C)
(valve variation 5)
Interface
Interface
–
152.4 cm (6.0 inch) lead wires, 18 awg.
–
Waterproof
–
A
LED
Plug-In Conduit Box
–
NEMA 4 rated
–
Phoenix connector
–
Lights, Manaplug available
Manaplug
(valve variations 6, 56, 630)
Interface
–
Brad Harrison Plug
–
3-Pin for Single Solenoid
–
5-Pin for Double Solenoid
Hirschmann Plug with Lights
Ground
Wire #1 (Green)
Solenoid (Negative)
Wire #3 (Red/Black)
ISO 4400/DIN 43650 Form “A”
Pin #3
(Ground)
Solenoid (Positive)
Wire #2 (Red/White)
3-Pin Manaplug (Mini) with Lights
Single Solenoid Valves
"B” Solenoid (Positive)
Wire #1 (Red/White)
"A” Solenoid (Negative)
Wire #2 (Red)
Pin #1
(Positive)
Pin #2
(Negative)
"B” Solenoid (Negative)
Wire #5 (Red/Black)
"A” Solenoid (Positive)
Wire #4 (Red/Yellow)
Ground
Wire #3 (Green)
Face View of Plug
5-Pin Manaplug (Mini) with Lights
Single and Double Solenoid Valves
("A" and "B" Solenoids Reversed for #8 and #9 Spools)
Micro Connector
DESINA Connector
valve variations 7A, 7B
M12 pin assignment
Standard
Solenoid (Negative)
Wire /3 (Blue)
Solenoid (Positive)
Wire /4 (Black)
1 = Not used
Ground
Wire /1 (Brown)
"B" Solenoid (Negative)
Wire /1 (Brown)
2 = Not used
"B" Solenoid (Positive)
Wire /2 (White)
3 = 0V
Ground
Wire /5 (Gray)
"A" Solenoid (Positive)
Wire /4 (Black)
DESINA – design
Pin 1 and 2
connected
4=
(24 V)
"A" Solenoid (Negative)
Wire /3 (Blue)
Signal
5 = Earth Ground
2502-A1.p65, dd
A29
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA

Documentos relacionados

Industrial Hydraulic Valves Catalog HY14-2502/US

Industrial Hydraulic Valves Catalog HY14-2502/US Inductive switch requiring +18-42 volt input. Outputs A and B are opposite; one at “0” voltage, the other at input voltage. During switching, A and B outputs reverse. Provides 0.4A switching current.

Leia mais

especialista mundial em infraestruturas elétricas e

especialista mundial em infraestruturas elétricas e QUADRO P17 DLP TP130* QUADRO MOSAIC DLP 1 MOD. TP40 QUADRO AP.ENC.DLP SIMPLES TP85* QUADRO AP.ENC.DLP SIMPLS TP130* CX.ISOLAMENTO AP.ENC.SIMPLES QUADRO AP.ENC.DLP DUPLO TP85*

Leia mais