Industrial Hydraulic Valves Catalog HY14-2502/US
Transcrição
Industrial Hydraulic Valves Catalog HY14-2502/US
Directional Control Valves Series D1VW Catalog HY14-2502/US Technical Information General Description The D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position and conform to NFPA’s D03/ CETOP 3 mounting patterns. B AB A PT Features • • • • • • Mechanically tunable soft shift • • • • • • • Internally ground Proportional spools, 21 standard spool styles available Repairable override DC surge suppression Nine electrical connection options AC & DC lights available (CSA approval for solenoids and lights) Easy access mounting bolts Waterproof (NEMA 4 rated) Specifications Explosion proof Mounting Pattern Mounting Interface CSA approved and U.L. recognized available No tools required for coil removal AC rectified coils Response Time* Maximum Pressure Nominal response time (milliseconds) at 345 Bar (5000 PSI) is 32 L/M (8.5 GPM). Solenoid Type Pull-In Drop-Out AC DC 8 Watt or 10 Watt DC 30 Watt 13 61 20 22 51 21 NFPA D03, CETOP 3; NG 6 DIN 24340-A6 ISO 4401-AB-03-4-A CETOP R35H 4.2-4-03, NFPA D03 P, A, B 345 Bar (5000 PSI) Standard CSA 276 Bar (4000 PSI) Tank: 103 Bar (1500 PSI) Standard 207 Bar (3000 PSI) Optional with H, FH, G, LG CSA 103 Bar (1500 PSI) * For soft shift, see ordering code X-number. 2502-A1.p65, dd A17 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA A Directional Control Valves Series D1VW Catalog HY14-2502/US Ordering Information Standard Valves A D 1V Directional Control Valve Basic Valve Actuator# Spool Style Seal Solenoid Voltage 2MD NFPA D03 CETOP 3 DIN NG6 Code W HW Code N V Description Solenoid, Wet Pin, Screw-in Reversed Wiring E* # Valve schematic symbols are per NFPA/ANSI standards, providing flow P to A when energizing solenoid A. Note operators reverse sides for #008 and #009 spools. See installation information for details. To configure per DIN standards (A coil over A port, B coil over B port) code valves as D1VHW***. Code Symbol A Code B 001 Code A D G J K L N Q R T U Y Z Description Nitrile Fluorocarbon EPR * Contact HVD for availability. Description 24/50 VAC 120 VDC 198 VDC 24 VDC 12 VDC 6 VDC 220/50 VAC 100/60 VAC 24/60 VAC 240/60 - 220/50 VAC 98 VDC 120/60 - 110/50 VAC 250 VDC Symbol A B 014 P T P T A B A B 002 015 P T A B Code Symbol b B* P A Description T B b 003 016 P T P T A B A B 004 b P T P T A B A B D† P T A B A 006 T B E T P T A B A B 007 F P T P T A B A B P T P T A B A B 010 P T P T B A B P T P T 011 082 M P T a A B P T a b A B P T b A B P T A B P T A B a a 2 position, spring centered and P to A 081 A T 2 position, spring offset P to B 030** K P 2 position, spring offset P to A and centered 026* H* B 2 position, spring centered and P to B 022 P A 2 position, detent, P to A and B to T 021 P B 3 position, spring centered 020* 005 008*, 009** C A 2 position, spring offset P to A P T A B P T a 2 position, spring offset P to B and centered * 020, 026 and 030 spools only. † 020 and 030 spools only. * 008, 020 & 026 spools have closed crossover. ** 009 & 030 spool have open crossover. See Universal Spool Chart for other spool options. 2502-A1.p65, dd A18 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Ordering Information Standard Valves A Solenoid Connection Code C D E G H*† J**† L M**† P S W* Coil Options Tube Options Manual Override Options Electrical Options Description Conduit Box Metric Plug (M12X1), DESINA Explosion Proof Plug-In Single Spade Deutsch (DT06-25) Dual Screw Lug Metri-Pack (150) DIN with Plug Double Spade DIN w/o Plug Code Omit S2* S3* S4* S5* S6* SN* I7 I8 * Not available with lights. ** See valve variations for others. † DC only. Code Omit D E F** C† L*** O U X* Description High Watt Explosion Proof, EEXD ATEX Explosion Proof, EEXME ATEX Low Watt CSA Hazardous Location 8 Watt Explosion Proof, MSHA Explosion Proof, UL/CSA No Coils Shift Response and Indication Approvals Design Series NOTE: Not required when ordering. Description Standard Response Soft Shift, 0.020" Orifice Soft Shift, 0.030" Orifice Soft Shift, 0.040" Orifice Soft Shift, 0.050" Orifice Soft Shift, 0.060" Orifice Soft Shift, No Orifice Monitor Switch Direct Op. End Stroke Monitor Switch Direct Op. Start Stroke * Not available with 8 watt. Code Omit J B Code Omit P T R W Description No Options Diode Surge Suppressor Rectified Coil Description Standard Extended with Boot None Repairable Waterproof Override Protection See solenoid voltage code to specify proper tube. ** AC only. *** DC/AC Rectified only. † Applicable to conduit box and plug-in style only. Code Omit 4* K Description Standard Valve C.S.A. Approved UL Recognition * Not available with high pressure tube. Code 5 6 7A 56 7B * 1A 1B 1C 1D Code Omit H M G Valve Variations Description Low Pressure, AC only High Pressure, AC only Low Pressure, DC-WI only High Pressure, DC-WI only 4D 4E Description Signal Lights Manaplug - Brad Harrison Mini Manaplug - Brad Harrison (12x1) Micro Manaplug (Mini) with Lights Manaplug (Micro) with Lights (D1 only) Manaplug (Mini) Single Sol. 5-pin Manaplug (Micro) Single Sol. 5-pin Manaplug (Mini) Single Sol. 5-pin, with Lights Manaplug (Micro) Single Sol. 5-pin, with Lights Twist & Lock Override (Old 5426) Push Manual Override (Old x5450) Valve Weight: Single Solenoid Double Solenoid Standard Bolt Kit: Metric Bolt Kit: 2502-A1.p65, dd A19 1.36 kg (3.0 lbs.) 1.6 kg (3.5 lbs.) BK209 BKM209 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Technical Information Solenoid Ratings A Insulation System Allowable Deviation from rated voltage Armature CSA File Number Environmental Capability Explosion Proof Solenoid Ratings* Class F -10% to +15% for DC and AC rectified coils -5% to +5% for AC Coils Wet pin type LR60407 DC Solenoids are rated at NEMA 4 (IP67) or better when properly wired and installed. Contact HVD for AC coil applications. U.L. & CSA (EU) M.S.H.A. (EO) ATEX (ED) CSA Hazardous Location Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G As defined by the NEC Complies with 30CFR, Part 18 Complies with ATEX requirements for: Exd, Group IIB; EN50014: 1999+ Amds. 1 & 2, EN50018: 2000 Class II, Groups E, F & G * Allowable Voltage Deviation +/- 10% Note that AC coils are single frequency only. Code Voltage Code Power Code A D L Voltage 24/50 VAC, High Watt 120 VDC G L 24/60 VAC, High Watt 24/50 VAC, High Watt 198 VDC J L 24 VDC K L 12 VDC L L 6 VDC M L 9 VDC E P R S T U X Y Z Specials 110/50 VAC 24/60 VAC, High Watt 24/60 VAC, Low Watt F ***Specials*** SEE BELOW 240/60 VAC, High Watt 220/50 VAC, High Watt 240/60 VAC, Low Watt F 220/50 VAC, Low Watt F 98 VDC L 16 VDC L 120/60 VAC, High Watt 110/50 VAC, High Watt 120/60 VAC, Low Watt F 110/50 VAC, Low Watt F 120/60 VAC, 10 Watt L*B 110/50 VAC, 10 Watt L*B 120/60 VAC, High Pressure *H 110/50 VAC, High Pressure *H 250 VDC L S Explosion Proof Solenoids R T N Y P Q K J D Z In Rush Amps In Rush Amps Amperage D1VW VA @ 3MM 7.00 Amps 168 VA N/A N/A N/A N/A 6.00 Amps 144 VA 7.00 Amps 168 VA N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 8.00 Amps 6.67 Amps 192 VA 160 VA 0.77 Amps 0.82 Amps 0.70 Amps 0.75 Amps N/A N/A 1.55 Amps 1.65 Amps 1.40 Amps 1.50 Amps 0.63 Amps 0.73 Amps 1.40 Amps 1.48 Amps N/A N/A 185 VA 180 VA 168 VA 165 VA N/A N/A 186 VA 182 VA 168 VA 165 VA 83 VA 79 VA 168 VA 163 VA N/A N/A Holding Amps Watts Resistance D1VW D1VW D1VW 2.65 Amps 28 W 1.67 ohm(s) 0.09 Amps 10 W 1584.00 ohm(s) 0.26 Amps 30 W 528.00 ohm(s) 1.85 Amps 20 W 1.67 ohm(s) 2.65 Amps 28 W 1.67 ohm(s) 0.05 Amps 10 W 3920.40 ohm(s) 0.15 Amps 30 W 1306.80 ohm(s) 0.44 Amps 10 W 51.89 ohm(s) 1.32 Amps 30 W 17.27 ohm(s) 0.88 Amps 10 W 12.97 ohm(s) 2.64 Amps 30 W 4.32 ohm(s) 1.67 Amps 10 W 3.59 ohm(s) 5.00 Amps 30 W 1.20 ohm(s) 1.11 Amps 10 W 8.12 ohm(s) 3.35 Amps 30 W 2.67 ohm(s) 0.38 Amps 19 W 135.00 ohm(s) 2.70 Amps 27 W 1.40 ohm(s) 2.20 Amps 23 W 1.52 ohm(s) 0.26 Amps 0.31 Amps 0.22 Amps 0.26 Amps 0.10 Amps 0.63 Amps 0.49 Amps 0.58 Amps 0.42 Amps 0.50 Amps 0.18 Amps 0.20 Amps 0.50 Amps 0.60 Amps 0.04 Amps 0.13 Amps 25 W 134.50 ohm(s) 27 W 134.50 ohm(s) 21 W 145.00 ohm(s) 23 W 145.00 ohm(s) 10 W 960.00 ohm(s) 10 W 25.60 ohm(s) 25 W 33.70 ohm(s) 27 W 33.70 ohm(s) 21 W 36.50 ohm(s) 23 W 36.50 ohm(s) 10 W 75.00 ohm(s) 10 W 75.00 ohm(s) 26 W 36.50 ohm(s) 28 W 36.50 ohm(s) 10 W 6875.00 ohm(s) 30 W 1889.64 ohm(s) Other voltages/frequencies may be available Contact HVD for more information 24/60 VAC 240/60 VAC 220/50 VAC 120/60 VAC 110/50 VAC 100/60 VAC 12 VDC 24 VDC 120 VDC 250 VDC 7.63 Amps 0.76 Amps 0.77 Amps 1.60 Amps 1.47 Amps 1.90 Amps N/A N/A N/A N/A 183 VA 183 VA 169 VA 192 VA 162 VA 192 VA N/A N/A N/A N/A 2.85 Amps 0.29 Amps 0.31 Amps 0.58 Amps 0.57 Amps 0.70 Amps 2.75 Amps 1.38 Amps 0.28 Amps 0.13 Amps 27 W 1.99 ohm(s) 27 W 1.34 ohm(s) 27 W 1.38 ohm(s) 27 W 33.50 ohm(s) 27 W 34.70 ohm(s) 27 W 38.60 ohm(s) 33 W 4.36 ohm(s) 33 W 17.33 ohm(s) 33 W 420.92 ohm(s) 33 W 1952.66 ohm(s) 2502-A1.p65, dd A20 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Plug-In Box, Double DC Solenoid A 49.6 (1.95) 44.9 (1.77) 87.8 (3.46) 15.5 (0.61) 54.3 Min. Coil (2.14) Removal 1/2 NPTF Thd. Both Ends 143.7 (5.66) 24.8 (0.98) 93.2 (3.67) 66.0 (2.60) 50.0 (1.97) 23.8 (0.94) 244.4 (9.62) 46.0 (1.81) Manual Override Plug-In Box, Single DC Solenoid 49.6 (1.95) 44.9 (1.77) 24.8 (0.98) 15.5 (0.61) 87.8 (3.46) 1/2 NPTF Thd. Both Ends 93.2 (3.67) 66.0 (2.60) 54.3 (2.14) Min. Coil Removal 188.5 (7.42) 50.0 (1.97) 23.8 (0.94) 46.0 (1.81) 2502-A1.p65, dd A21 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) A Hirschmann, Double DC Solenoid 46.0 (1.81) 72.6 (2.86) 12.0 (0.47) Min. Connector Removal 115.4 (4.54) 54.3 (2.14) Min. Coil Removal 25.3 (1.00) 142.1 (5.59) 15.5 (0.61) 23.0 (0.91) 77.6 (3.06) 66.3 (2.61) 50.0 (1.97) 23.8 (0.94) 244.4 (9.62) Manual Override Hirschmann, Single DC Solenoid 46.0 (1.81) 23.0 (0.91) 15.5 (0.61) 25.3 (1.00) 77.6 (3.06) 54.3 (2.14) Min. Coil Removal 100.8 (3.97) 72.6 (2.86) 12.0 (0.47) Min. Conn. Removal 66.3 (2.61) 50.0 (1.97) 23.8 (0.94) 168.3 (6.63) Manual Override 2502-A1.p65, dd A22 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit Box, Double AC Solenoid 79.9 (3.15) 36.8 (1.45) A 126.8 (5.00) 42.75 (1.68) Min. Coil Removal ½ NPTF Thread Both Ends 49.5 (1.95) 24.8 (0.98) 15.5 (0.61) 3.0 (0.19) 94.6 (3.72) 66.0 (2.60) 50.0 (1.97) 23.8 (0.94) See Note 210.7 (8.30) Note: 22.0 mm (.87”) from bottom of bolt hole counterbore to bottom of valve. 46.0 (1.81) Manual Override Conduit Box, Single AC Solenoid 49.5 (1.95) 24.8 (0.98) 42.75 (1.68) Min. Coil Removal 84.0 (3.31) 36.8 (1.45) ½ NPTF Thread Both Ends 15.5 (0.61) 3.0 (0.19) 94.6 (3.72) 66.0 (2.60) 50.0 (1.97) 23.8 (0.94) 163.7 (6.44) 46.0 (1.81) Manual Override 2502-A1.p65, dd A23 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) A Conduit Box, Double AC Solenoid with Variation 6 (Manaplug) & Variation P (Extended Manual Override) 42.8 (1.69) Min. Coil Removal 126.8 (4.99) 95.7 (3.77) 36.8 (1.45) Connector NFPA T3.5.29 25.4 (1.00) Hex 49.5 (1.95) 24.8 (0.98) 15.5 (0.61) 3.0 (0.19) 94.6 (3.72) Extended Manual Override 66.0 (2.60) 50.0 (1.97) 23.8 (0.94) 225.0 (8.86) Manual Override 46.0 (1.81) 61.2 (2.41) Minimum Coil Removal Conduit Box, Double DC & AC Rectified Solenoids with Variation 6 (Manaplug) & Variation P (Extended Manual Override) 142.1 (5.59) 95.7 (3.77) 79.9 (3.15) 36.8 (1.45) 54.3 (2.14) Min. Coil Removal Connector per NFPA T3.5.29 25.4 (1.00) Hex 49.5 (1.95) 24.8 (0.98) 15.5 (0.61) 3.0 (0.19) 94.6 (3.72) Extended Manual Override 66.0 (2.60) 50.0 (1.97) 23.8 (0.94) 72.7 (2.86) Min. Coil Removal 46.0 (1.81) 255.4 (10.01) Manual Override 2502-A1.p65, dd A24 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit Box, Double AC Solenoid A with Variation R (Repairable Override) 49.5 (1.95) 79.9 (3.15) 36.8 (1.45) 138.1 (5.44) 54.8 (2.16) Min. Coil Removal ½ NPTF Thread Both Ends 15.5 (0.61) 3.0 (0.19) 24.8 (0.98) 94.6 (3.72) 66.0 (2.60) 50.0 (1.97) 23.8 (0.94) 46.0 (1.81) 233.3 (9.19) Manual Override Conduit Box, Double DC Solenoid with Variation R (Repairable Override) 49.6 (1.95) 44.9 (1.77) 87.8 (3.46) 66.3 (2.61) Min. Coil Removal 1/2 NPTF Thd. Both Ends 155.0 (6.10) 15.5 (0.61) 24.8 (0.98) 93.2 (3.67) 66.0 (2.60) 267.0 (10.51) 50.0 (1.97) 23.8 (0.94) 46.0 (1.81) Manual Override 2502-A1.p65, dd A25 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) A DESINA, Double DC Solenoid 48.0 (1.89) 90.7 (3.57) 142.1 (5.59) 54.3 (2.14) Min. Coil Removal 15.5 (0.61) 70.3 (2.77) 50.8 (2.00) 23.8 (0.94) 46.0 (1.81) Manual Override 242.4 (9.54) DESINA, Single DC Solenoid 90.7 (3.57) 142.1 (5.59) 543 (2.14) Min. Coil Removal 15.5 (0.61) 70.3 (2.77) 50.8 (2.00) 23.8 (0.94) 167.3 (6.59) 46.0 (1.81) Manual Override 2502-A1.p65, dd A26 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Explosion Proof U.L. & C.S.A., Double Solenoid 163.7 (6.44) 60.4 (2.38) A 18 Inch Lead Wires Standard 1/2" NPT 94.4 (3.72) 15.1 (0.61) 130.8 (5.15) 7.5 (0.30) 304.4 (11.98) 46.0 (1.81) 73.0 (2.87) Explosion Proof M.S.H.A., Double Solenoid 3/4-20 UNF Thd. 163.7 (6.44) 60.4 (2.38) 3/4-20 UNF Thd. 38.0 (1.50) 113.0 (4.45) 130.8 (5.15) 15.51 (0.61) 7.5 (0.30) 304.4 (6.44) 46.0 (1.81) 73.0 (2.87) Explosion Proof ATEX, Double Solenoid 74.7 (2.94) 69.9 (2.75) 19.4 (0.76) M20 x 1.5-6H Thd. 15.5 (0.61) 131.7 (5.19) 100.9 (3.97) 100.6 (3.96) 42.8 (1.69) 7.5 (0.30) 46.0 (1.81) 141.0 (5.55) 324.7 (12.78) 73.5 (2.89) 2502-A1.p65, dd A27 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) A Conduit Box, Single DC Solenoid with Variation I7 (Monitor Switch) & Variation P (Extended Manual Override) B 72.7 (2.86) Min.Coil Removal 49.5 (1.95) 15.5 (0.61) 3.0 (0.12) 115.1 (4.53) 12.0 (0.47) Min. Conn. Removal 24.8 (0.98) 94.6 (3.72) 81.9 (3.22) 50.0 (1.97) 70.6 (2.78) Extended Manual Override 23.8 (0.94) 46.0 (1.81) 274.9 (10.82) Monitor Switch (valve variation I7) Block Diagram Pin 1 (Input 24VDC) Inductor This feature provides for electrical confirmation of the spool shift. This can be used in safety circuits, to assure proper sequencing, etc. Pin 2 (Output – Normally Open) Regulator Pin 3 (Output – Normally Closed) Switch Data Inductive switch requiring +18-42 volt input. Outputs A and B are opposite; one at “0” voltage, the other at input voltage. During switching, A and B outputs reverse. Provides 0.4A switching current. Pin 4 (Ground Terminal) (Extended, or Energized Position) For repetitive switch power-up conditions, please consult factory. 2502-A1.p65, dd A28 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D1VW Catalog HY14-2502/US Accessories Conduit Box Signal Lights (connection option G & C) (valve variation 5) Interface Interface – 152.4 cm (6.0 inch) lead wires, 18 awg. – Waterproof – A LED Plug-In Conduit Box – NEMA 4 rated – Phoenix connector – Lights, Manaplug available Manaplug (valve variations 6, 56, 630) Interface – Brad Harrison Plug – 3-Pin for Single Solenoid – 5-Pin for Double Solenoid Hirschmann Plug with Lights Ground Wire #1 (Green) Solenoid (Negative) Wire #3 (Red/Black) ISO 4400/DIN 43650 Form “A” Pin #3 (Ground) Solenoid (Positive) Wire #2 (Red/White) 3-Pin Manaplug (Mini) with Lights Single Solenoid Valves "B” Solenoid (Positive) Wire #1 (Red/White) "A” Solenoid (Negative) Wire #2 (Red) Pin #1 (Positive) Pin #2 (Negative) "B” Solenoid (Negative) Wire #5 (Red/Black) "A” Solenoid (Positive) Wire #4 (Red/Yellow) Ground Wire #3 (Green) Face View of Plug 5-Pin Manaplug (Mini) with Lights Single and Double Solenoid Valves ("A" and "B" Solenoids Reversed for #8 and #9 Spools) Micro Connector DESINA Connector valve variations 7A, 7B M12 pin assignment Standard Solenoid (Negative) Wire /3 (Blue) Solenoid (Positive) Wire /4 (Black) 1 = Not used Ground Wire /1 (Brown) "B" Solenoid (Negative) Wire /1 (Brown) 2 = Not used "B" Solenoid (Positive) Wire /2 (White) 3 = 0V Ground Wire /5 (Gray) "A" Solenoid (Positive) Wire /4 (Black) DESINA – design Pin 1 and 2 connected 4= (24 V) "A" Solenoid (Negative) Wire /3 (Blue) Signal 5 = Earth Ground 2502-A1.p65, dd A29 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA
Documentos relacionados
Industrial Hydraulic Valves Catalog HY14-2502/US
Inductive switch requiring +18-42 volt input. Outputs A and B are opposite; one at “0” voltage, the other at input voltage. During switching, A and B outputs reverse. Provides 0.4A switching current.
Leia maisespecialista mundial em infraestruturas elétricas e
QUADRO P17 DLP TP130* QUADRO MOSAIC DLP 1 MOD. TP40 QUADRO AP.ENC.DLP SIMPLES TP85* QUADRO AP.ENC.DLP SIMPLS TP130* CX.ISOLAMENTO AP.ENC.SIMPLES QUADRO AP.ENC.DLP DUPLO TP85*
Leia mais