Mark Hopkins - Hughes Associates Fire Engineering Consulting
Transcrição
Mark Hopkins - Hughes Associates Fire Engineering Consulting
Segurança contra Incêndios Fire Safety I Conferência NFPA - Portugal Estoril | 19 e 20 | Outubro | 06 Biography: Mark Hopkins, P.E. is a senior fire protection engineer with Hughes Associates, Inc. in Baltimore, MD. He has been conducting corrosion investigations for approximately 5 years and has extensive experience with the installation, design, and evaluation of sprinkler systems. Mark is the author of the Focus on Fire Protection column published by the American Society of Plumbing Engineers periodical Plumbing Systems & Design. He is a member of NFPA, the Society of Fire Protection Engineers, and NACE International. Mark holds both a bachelor-of-science degree and masters-ofscience degree in fire protection engineering from the University of Maryland at College Park. Corrosion in Dry Pipe and Preaction Sprinkler Systems This presentation identifies design limitations and installation pitfalls which influence corrosion in dry pipe and preaction sprinkler systems. The presentation identifies how corrosion is commonly detected and why it is a problem. The basic forms of corrosion, its affects on system reliability, and failure mode concepts will be described. The basic framework for conducting corrosion investigations, factors for consideration in determining whether to salvage or replace a system, and possible corrosion management strategies will also be discussed. A case study of an investigation conducted at a museum facility will be shared. Rua da República, Nº 270, Cacia Apartado nº 761 3801-801 Aveiro www.nfpaportugalconference.com NFPA R organização: em associação com:
Documentos relacionados
Segurança contra Incêndios Fire Safety
Segurança contra Incêndios Fire Safety I Conferência NFPA - Portugal Estoril | 19 e 20 | Outubro | 06
Leia maisSegurança contra Incêndios Fire Safety
The application of CPVC as Fire Sprinkler System Speaker of presentation Ms Sinikka Freidhof Curriculum Ms Freidhof has been employed by Noveon Europe BVBA since 1999 and has been working for the S...
Leia maisProteção Fixa Incluindo Sprinklers
CEA 4001en (Europe) “Sprinkler Systems: Planning and Installation” NFPA 13 (USA) “Standard for the Installation of Sprinkler Systems” SS EN 12845 also known as SBF 120:7 (Sweden) “Regler för ...
Leia mais3º PRATICOM - Encontro Cásper Líbero de Práticas de
Implantação da Comunicação Digital do Governo do Estado de São Paulo
Leia mais