LS - Pendant - OM
Transcrição
LS - Pendant - OM
Installation Instructions Rua Santa Bárbara 27/45 4400–289 Vila Nova de Gaia Portugal Rua Fábrica Material de Guerra 10 – Porta 2 1950–128 Lisboa Portugal t. +351 223 710 419 f. +351 223 702 044 t. +351 211 919 300 f. +351 223 702 044 Av. Dr. Cardoso de Melo 1470 Edificio Net Office Cj. 108 Vila Olímpia 04548–005 São Paulo Brasil [email protected] www.om-light.com t. +55 (11) 3045 3095 LS - Pendant 01 02 12 Specifications • Emergency luminaire. • Structure in aluminium profile. • Pictogram printed on adhesive film with standardised signage. • Maintained or non-maintained emergency luminaire prepared for remote control. Page 1/3 RAL 00 IP 22 | 230V | 50/60Hz Compliant with standards: EN 60598-2-22 EN 60598-1 UNE 20392 Standard accessories • No. 6 plastic wall plugs • A2 stainless steel DIN 7505A 4.5 mm (width) x 40 mm (length) screws • Suspension accessories. Available wattages 3W (LED) Installation Instructions Rua Santa Bárbara 27/45 4400–289 Vila Nova de Gaia Portugal Rua Fábrica Material de Guerra 10 – Porta 2 1950–128 Lisboa Portugal t. +351 223 710 419 f. +351 223 702 044 t. +351 211 919 300 f. +351 223 702 044 Av. Dr. Cardoso de Melo 1470 Edificio Net Office Cj. 108 Vila Olímpia 04548–005 São Paulo Brasil [email protected] www.om-light.com t. +55 (11) 3045 3095 LS - Pendant 1st step Switch off power supply; 2nd step Marking the anchorage locations on the ceiling; Drill attachment holes 3rd step Remove the top cover; 4th step Attach the canopy to the ceiling; (Front view) 5th step Attach the suspension; Connect the wiring; 6th step Feed through mains cable; (Side view) 7th step Fit the cover; (Front view) 8th step Attach the 2nd suspension cable; Page 2/3 Installation Instructions Rua Santa Bárbara 27/45 4400–289 Vila Nova de Gaia Portugal Rua Fábrica Material de Guerra 10 – Porta 2 1950–128 Lisboa Portugal t. +351 223 710 419 f. +351 223 702 044 t. +351 211 919 300 f. +351 223 702 044 Av. Dr. Cardoso de Melo 1470 Edificio Net Office Cj. 108 Vila Olímpia 04548–005 São Paulo Brasil t. +55 (11) 3045 3095 LS - Pendant 9th step Feed the wiring through the cover; Connect the emergency luminaire wiring; 10th step Attach to the cover; Wiring diagram; Non-Maintained Maintained 11st step Test button; (For further information on tests and auto-tests see Page 3) Emergency luminaire installed. Test button Page 3/3 [email protected] www.om-light.com Installation Instructions Rua Santa Bárbara 27/45 4400–289 Vila Nova de Gaia Portugal Rua Fábrica Material de Guerra 10 – Porta 2 1950–128 Lisboa Portugal t. +351 223 710 419 f. +351 223 702 044 t. +351 211 919 300 f. +351 223 702 044 Av. Dr. Cardoso de Melo 1470 Edificio Net Office Cj. 108 Vila Olímpia 04548–005 São Paulo Brasil [email protected] www.om-light.com t. +55 (11) 3045 3095 Tests Connection • After connecting to the power network, charging begins and will be indicated by the LED display. After approximately 20 hours of charging the light is operational. For the battery to reach full capacity, up to 5 charging/discharging operations may be required (battery remanence). • In order to ensure proper initial setup, at least one discharging cycle must be carried out (disconnect from the network for 3 hours) to verify that the specified battery capacity has been reached. Autotest • According to the regulations, the electronics performs the following tests automatically: - Function test : 28 days after switching the supply on. Test duration: 5min; - Capacity test: The 12th function test runs as duration test.Test duration: 3h. • If the built-in battery is completely or partly discharged, the automatic capacity test is delayed by up to 24 hours. Manuel Test • By pressing the “test” button (1 sec), a manual test is triggered. The test will end automatically after 5 minutes and has no effect on the scheduled test times. Pressing the Button for more than 3 sec. until the green LED is flashing or Maintainedly lightning the test will be interrupted.. Function display (LED) • Operating conditions and malfunctions are displayed according to the following list: • Boost charge - green flashing (1 s cycle); • Normal charge - green Maintainedly; • Emergency operation (power off) - off; • Function test runs - orange flashing (0.5 s cycle); • Capacity test runs - orange flashing (1 s cycle); • Charge / Bad Battery - red Maintainedly; • Defective lamp - red flashing (1 s cycle); • Battery fault - red flashing (0.5 s cycle). Quit • The errors determined by a test (red LED) will be displayed until a new operation condition is detected by another test. • To reset the error indication after correcting the error, it must triggered a test again (manually or automatically). Installation Instructions Rua Santa Bárbara 27/45 4400–289 Vila Nova de Gaia Portugal Rua Fábrica Material de Guerra 10 – Porta 2 1950–128 Lisboa Portugal t. +351 223 710 419 f. +351 223 702 044 t. +351 211 919 300 f. +351 223 702 044 Av. Dr. Cardoso de Melo 1470 Edificio Net Office Cj. 108 Vila Olímpia 04548–005 São Paulo Brasil t. +55 (11) 3045 3095 General conditions Installation/Maintenance • The installation and maintenance of the different products must be performed by a qualified professional. The installation conditions described in the installation instructions and the operating conditions mentioned in the product datasheet must be duly guaranteed. Osvaldo Matos cannot be held liable for the incorrect assembly, installation, maintenance, repair or handling of its products. Osvaldo Matos cannot be held liable for unsuitable fittings. Osvaldo Matos cannot be held liable for product alteration or for instalation instructions not being duly followed. O/M products are prepared for installation in areas with ambient temperatures between 0ºC and 35ºC. Osvaldo Matos recommends that any false ceilings intended for the placement of recessed products should only be erected after the products to be mounted have been chosen. The same applies for the opening of slots to mount this type of product. Osvaldo Matos recommends reinforcing the ceiling close to the Mounting cutout according to the product characteristics. Performance • The performance of the product will only be guaranteed if its handling, use, installation and maintenance are performed according to the supplied instructions. Power values in products with LED Light Source may have a 10% variation on the indicated value. Flux indicated for LED systems is a mean value, for Tj=25°C. Photometry results are obtained by testing a standard product of each range, in the laboratory under ideal conditions. Sales conditions • All electrical components included in the products are of high quality. Warranty • O/M products have a 3-year warranty from the delivery date for any proven construction or manufacturing defects, provided the transport conditions, installation conditions described in the installation instructions and the operating conditions mentioned in the product datasheet are duly guaranteed. Parts and components requiring replacement due to normal wear are excluded from this warranty. The products must be installed and maintained by qualified personnel in accordance with the accompanying instructions, and they cannot be altered or repaired without the prior written permission of Osvaldo Matos. Osvaldo Matos must be formally notified of any defect that is found and covered by the warranty. Osvaldo Matos decides whether to repair and/or replace the product for the same or an equivalent product, subject to the changes arising from the technological evolution of the manufacturing process at that time, unless another solution is imposed by mandatory law. Returned products will only be accepted within 10 days of their delivery, and only for manufacturing defects that are confirmed by the factory, unless another conditions are stipulated by mandatory law. Hence, we recommend that products are checked on delivery. [email protected] www.om-light.com
Documentos relacionados
Installation Instructions - OM
for the opening of slots to mount this type of product. Osvaldo Matos recommends reinforcing the ceiling close to the Mounting cutout according to the product characteristics.
Leia mais