Model TR800 Transmitters
Transcrição
Transmitters Model TR800 Compact Size, 1.73” (44mm) in Diameter For Quick Fit in Most Industrial Protection Heads High Precision (Accuracy = 0.1% of Span), Low Cost Enhanced RFI and EMI Protection for Better Measurement Stability Universal Input Capability Accommodating Thermocouple Types J, K, and Pt-100 RTD Bottom View of Cover Fixed-Range Units Offered in Standard or Special Bottom Section Simpson’s model TR800 is a high precision, low cost transmitter designed to control an output current (4-20mA) in a linear relationship with a low level input signal for accurate transmission over long distances. The TR800 provides non-isolated, two-wire, 4-20mA amplification of low level process signals, including J, K, and Pt100 inputs. Each transmitter offers 2 to 3-wire compensation and linearization for Pt-100, and ice point reference compensation for thermocouples that are voltage linear. On the model TR800, range is determined by a set of internally mounted resistors. No soldering of resistors is required which allows for easy configuring of unit in the field. Dimensions and Installation Fits most industrial protection heads. Typical Application PERFORMANCE Accuracy: ±0.1% of span Adjustability: ±25% for both zero and span Burnout Detection: Upscale-standard Standard Range Selection Chart - Sensor Type 8C 8F RTD -50+50 -50+125 * 0+50 0+125 * 0+100 0+212 * 0+200 0+300 * * * 0+400 0+500 * * * 0+500 0+750 * * 0+600 0+1000 * * 0+800 0+1500 * * 0+1000 0+2000 * * 0+1200 0+2200 * K INPUT RTD: Pt-100, 2 or 3-wire TC: all known types Linearity: Better than ±0.03% of span (for TC/mV), ±0.05% of span (for RTD) Stability (For Both Zero & Span): Pt-100 (100°C span): 0.03% of span/°C, TC/mV (25mV input): 0.04% of span/°C T/C Cold Junction Compensation: <0.05°C/°C of ambient temperature INPUT SPAN RTD: 20°C (36°F) min, 500°C (900°F) max TC: 10mV min span J OUTPUT Range: 4-20mA DC Limit: 2.5 to 28mA Maximum Load: Rmax = (V supply - 10V) ÷ 20mA ENVIRONMENTAL Ambient Temperature: -20 + 70°C (-4 + 160°F) Humidity: 0-95% RH, non-condensing ELECTRICAL Supply Voltage: 8-38 VDC polarity protected RFI and EMI immunity from 20MHz to 500MHz Wiring Diagrams RTD Configuration Thermocouple Configuration Hawk Controller Hawk Controller Thermocouple Pt-100RTD - ZERO SPAN 2 3 4 5 6 1 2 3 4 5 6 +V -V + 1 1 2 3 4 5 2 3 4 5 +V -V - + SPAN ZERO 1 CONFIGURATION: - 1. Connect the positive supply lead to terminal one. 2. Connect the negative supply lead to terminal two. 3. For Pt-100 RTD Inputs, connect the Pt-100 leads to input terminals 4, 5, and 6 according to the RTD wiring diagram. 4. For thermocouple inputs, connect the thermocouple leads to input terminals 6 6 + Cover Top View Cover Top View Ordering Information TR800 INPUT TYPE 1 2 RTD TC TC TYPE 0 1 2 NONE (if RTD or MV) J K UNITS (Measurement) 2 INPUT SENSOR RANGE (MV or Temperature) F8 ex. 0 - 300 Indicates Span Range (Limited Available Product) For quickest delivery please choose sensor type and range form the Standard Range Selection Chart. If special ranges are required please contact Simpson for ordering information. Simpson Electric Co. 853 Dundee Ave. Elgin, IL 60120-3090 Printed in USA • Ph 847-697-2260 • Fx 847-697-2272 Part No. 06-116806, Rev 3 12/00
Documentos relacionados
Transmissor de Temperatura
distributor, model PH201G (Style B) The distributor, model PH201G, is designed to connect with the 2-Wire Analyzer. This distributor supplies drive power to the analyzer and receives simultaneously...
Leia maisTemperature Uniformity and System Accuracy
is a general difference between the furnace chamber and the work space. The furnace chamber is the total volume available in the furnace. The work space is smaller than the furnace chamber and desc...
Leia maisSensor Controller S3D8
The set time of a timer can be experimentally changed and operation monitored even while the Sensor Controller is operating. Attach the S3D-P setting unit to the Sensor Controller. Then read out th...
Leia maisHygroClip 2 (HC2) Humidity Temperature Probes: User Guide
The HC2 series are digital humidity-temperature probes based on the AirChip 3000 technology. These probes feature a UART serial interface and two 0…1 V linear analog output signals. The HC2 probes ...
Leia mais