Model TR800 Transmitters

Transcrição

Model TR800 Transmitters
Transmitters
Model TR800
Compact Size, 1.73” (44mm) in Diameter For Quick Fit
in Most Industrial Protection Heads
High Precision (Accuracy = 0.1% of Span), Low Cost
Enhanced RFI and EMI Protection for Better
Measurement Stability
Universal Input Capability Accommodating
Thermocouple Types J, K, and Pt-100 RTD
Bottom View of Cover
Fixed-Range Units Offered in Standard or Special
Bottom Section
Simpson’s model TR800 is a high precision, low cost transmitter designed to control an output current (4-20mA) in a
linear relationship with a low level input signal for accurate
transmission over long distances.
The TR800 provides non-isolated, two-wire, 4-20mA amplification of low level process signals, including J, K, and Pt100 inputs.
Each transmitter offers 2 to 3-wire compensation and linearization for Pt-100, and ice point reference compensation
for thermocouples that are voltage linear.
On the model TR800, range is determined by a set of internally mounted resistors. No soldering of resistors is required
which allows for easy configuring of unit in the field.
Dimensions and Installation
Fits most industrial protection
heads.
Typical Application
PERFORMANCE
Accuracy: ±0.1% of span
Adjustability: ±25% for both zero and span
Burnout Detection: Upscale-standard
Standard Range Selection Chart - Sensor Type
8C
8F
RTD
-50+50
-50+125
*
0+50
0+125
*
0+100
0+212
*
0+200
0+300
*
*
*
0+400
0+500
*
*
*
0+500
0+750
*
*
0+600
0+1000
*
*
0+800
0+1500
*
*
0+1000
0+2000
*
*
0+1200
0+2200
*
K
INPUT
RTD: Pt-100, 2 or 3-wire
TC: all known types
Linearity: Better than ±0.03% of span (for TC/mV), ±0.05% of
span (for RTD)
Stability (For Both Zero & Span):
Pt-100 (100°C span): 0.03% of span/°C,
TC/mV (25mV input): 0.04% of span/°C
T/C Cold Junction Compensation: <0.05°C/°C of ambient temperature
INPUT SPAN
RTD: 20°C (36°F) min, 500°C (900°F) max
TC: 10mV min span
J
OUTPUT
Range: 4-20mA DC
Limit: 2.5 to 28mA
Maximum Load: Rmax = (V supply - 10V) ÷ 20mA
ENVIRONMENTAL
Ambient Temperature: -20 + 70°C (-4 + 160°F)
Humidity: 0-95% RH, non-condensing
ELECTRICAL
Supply Voltage: 8-38 VDC polarity protected
RFI and EMI immunity from 20MHz to 500MHz
Wiring Diagrams
RTD Configuration
Thermocouple Configuration
Hawk Controller
Hawk Controller
Thermocouple
Pt-100RTD
-
ZERO SPAN
2
3
4
5
6
1
2
3
4
5
6
+V -V
+
1
1
2
3
4
5
2
3
4
5
+V -V
-
+
SPAN
ZERO
1
CONFIGURATION:
-
1.
Connect the positive supply lead to terminal one.
2.
Connect the negative supply lead to terminal two.
3.
For Pt-100 RTD Inputs, connect the Pt-100 leads to input terminals
4, 5, and 6 according to the RTD wiring diagram.
4.
For thermocouple inputs, connect the thermocouple leads to input
terminals
6
6
+
Cover Top View
Cover Top View
Ordering Information
TR800
INPUT TYPE
1
2
RTD
TC
TC TYPE
0
1
2
NONE (if RTD or MV)
J
K
UNITS (Measurement)
2
INPUT SENSOR RANGE
(MV or Temperature)
F8
ex.
0 - 300
Indicates Span Range
(Limited Available
Product)
For quickest delivery please choose sensor type and range form the Standard Range Selection Chart.
If special ranges are required please contact Simpson for ordering information.
Simpson Electric Co. 853 Dundee Ave. Elgin, IL 60120-3090
Printed in USA
•
Ph 847-697-2260
•
Fx 847-697-2272
Part No. 06-116806, Rev 3 12/00

Documentos relacionados

Transmissor de Temperatura

Transmissor de Temperatura distributor, model PH201G (Style B) The distributor, model PH201G, is designed to connect with the 2-Wire Analyzer. This distributor supplies drive power to the analyzer and receives simultaneously...

Leia mais

Temperature Uniformity and System Accuracy

Temperature Uniformity and System Accuracy is a general difference between the furnace chamber and the work space. The furnace chamber is the total volume available in the furnace. The work space is smaller than the furnace chamber and desc...

Leia mais

Sensor Controller S3D8

Sensor Controller S3D8 The set time of a timer can be experimentally changed and operation monitored even while the Sensor Controller is operating. Attach the S3D-P setting unit to the Sensor Controller. Then read out th...

Leia mais

HygroClip 2 (HC2) Humidity Temperature Probes: User Guide

HygroClip 2 (HC2) Humidity Temperature Probes: User Guide The HC2 series are digital humidity-temperature probes based on the AirChip 3000 technology. These probes feature a UART serial interface and two 0…1 V linear analog output signals. The HC2 probes ...

Leia mais