ED 200-D Mounting and installing manual Montage

Transcrição

ED 200-D Mounting and installing manual Montage
Automatik
WN 057059 45532
12/06
DORMA
ED 200-D
Mounting and installing manual
Montage, Einstellung und
Inbetriebnahmeanleitung
194 553-01-6-50
WN 057059 45532
02 02/07
DORMA
Automatik
194 553-01-6-50
Inhaltsverzeichniss
02.2007
Seite
Contents
Inhaltsverzeichnis
--------Sicherheitshinweise nach DIN 18650 -----
-
-
-
-
Page
-
-
-
--------------------------------------------------Contents - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -----------------------------------------------3Safety advice DIN 18650 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 -
------------------Montage / Einstellung / Inbetriebnahme Texte ----------
-
-
-----------------------------------------------7
Mounting instructions Pictures - - - - - - - - - - - - - - - - - - - - - - - - - - - 7
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19
Mounting instructions / Adjustment / Commissioning texts - - - - - - - - 22
-
18
18
21
24
Klemmenbelegung Steuerung “A” “B” -----
Montageanleitung Bilder
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
2
4
6
-
-
-
-
-
-
-
-
-
--------------------------------Terminal definitions “A”Terminal definitions “B”
-
25
26
27
28
-
-
-
-
-
-
-
-
-
Connection diagrams
-------------------------------------------------Conductor colour code - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 30Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 30-
29
29
31
31
Anschlußpläne
Ader-Ident-Farbcode Übersicht
-
-
-
Intern - Ruhestromverriegeluing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 32
- - - - - - - - - - - - Internal - Activ locking system - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 32
Arbeitsstromverriegelung- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 33
- - - - - - - - - - - - Passiv locking system - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 33
mit 4-SAVE Sensor
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 34
- - - - - - - - - - - - with 4-SAVE sensor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 34
mit IRS 3 Sensor
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 35 - 36
- - - - - - - - - - - - with IRS 3 sensor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 35 - 36
Zweiflügelige Türen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 37
- - - - - - - - - - - - Dubbelleaf doors- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 37
Wartung bei Verwendung als Feststellanlage - - - - only for germany - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 38
2
2
DORMA
Sicherheit
WN 057014 45532
06/06
DORMA
D
Sicherheitshinweise
1. Bestimmungsgemäßer Gebrauch
Türantriebe dienen ausschließlich zum Öffnen und Schließen von Türen.
Das Spielen mit den Anlagen/Geräten durch kleine Kinder ist nicht gestattet.
Kinder nicht mit den Anlagen oder fest montierten Regel- und/oder Steuereinrichtungen
spielen lassen. Fernsteuerungen außerhalb der Reichweite von Kindern halten.
2. Produktspezifische Eigenarten
DORMA Türantriebe werden wie folgt eingesetzt:
4an Drehflügel-Anschlagtüren.
- DORMA CD 80
- DORMA ED 200
- DORMA CD 400
4an Drehflügel-Anschlagtüren und an Brandschutztüren.
- DORMA ES 200
- DORMA ES 200 Easy
4an Schiebetüren.
- DORMA ES 200 2D
4an Schiebetüren und an Flucht- und Rettungswegtüren.
3. Normen, Gesetze, Richtlinien und Vorschriften
Der neueste Stand der allgemeingültigen und länderspezifischen Normen, Gesetze,
Richtlinien und Vorschriften ist einzuhalten.
4. Haftungsbeschränkung
Der Antrieb darf nur gemäß seiner bestimmungmäßigen Verwendung eingesetzt werden.
Eigenmächtige Änderungen an der Anlage schließen jede Haftung durch die DORMA GmbH +
Co. KG für daraus resultierende Schäden aus.
5. Dokumentationsunterlagen
WICHTIGE ANWEISUNGEN FÜR SICHERE MONTAGE.
ALLE ANWEISUNGEN IN DEN DOKUMENTATIONSUNTERLAGEN BEACHTEN.
(z.B Briefumschlag mit der Aufschrift Dokumentationsunterlagen)
FALSCHE MONTAGE KANN ZU ERNSTHAFTEN VERLETZUNGEN FÜHREN.
FÜR DIE SICHERHEIT VON PERSONEN IST ES WICHTIG, DIESEN ANWEISUNGEN FOLGE ZU LEISTEN.
DIESE ANWEISUNGEN SIND AUFZUBEWAHREN.
6. Allgemeine Hinweise zur Montage
Bauseitige Vorbereitung
Den Arbeitsplatz gegen unbefugtes Betreten sichern.
Herunterfallende Teile oder Werkzeuge können zu Verletzungen führen
Die Befestigungsart und die Befestigungsmittel, wie z.B. Schrauben und Dübel, müssen auf
jeden Fall den baulichen Gegebenheiten angepaßt werden (Stahlkonstruktion, Holz, Beton
usw.).
Vor dem Einbau des Antriebs den/die Türflügel auf einwandfreien mechanischen Zustand und
Leichtgängigkeit prüfen.
3
DORMA
Sicherheit
Nach der Montage
Im Anschluss an die Montage sind die Einstellungen und die Funktionsweise des Antriebes
und der Schutzeinrichtungen zu überprüfen.
Die hier beschriebene Montage des Antriebs ist ein Beispiel. Bauliche oder örtliche
Gegebenheiten, vorhandene Hilfsmittel oder andere Umstände können eine andere
Vorgehensweise sinnvoll machen.
7. Restrisiken
An automatischen Türen können Quetsch-, Scher-, Stoß- und Einzugsgefahren entstehen. Je
nach baulicher Gegebenheit, Türvariante und Absicherungsmöglichkeit können Restgefahren
nicht ausgeschlossen werden. Zum Beispiel kraftbegrenztes Anstoßen oder Quetschen.
Gegenschließkante
Nebenschließkante
Hauptschließkante
Hauptschließkante
Nebenschließkante
8. Wartung und Pflege
Die Anlage ist vor der ersten Inbetriebnahme und je nach Bedarf, jedoch mindestens einmal
jährlich, von einem Sachkundigen zu prüfen und ggf. zu warten.
Die Wartung muss regelmäßig, nach den Vorgaben des Herstellers, von einer dafür
ausgebildeten Person durchgeführt werden.
(BG-Regel für kraftbetätigte Türen, Fenster und Tore. BGR 232/DIN 18650)
Vor Instandhaltungsarbeiten (Reinigung oder Wartung) muss der Antrieb abgeschaltet und
gegen irrtümliches und unbefugtes Einschalten gesichert werden.
Wir empfehlen, mit DORMA darüber einen Wartungsvertrag abzuschließen.
DORMA GmbH + Co.KG
4
Postfach 40 09 D-58247 Ennepetal • Breckerfelder Straße 42-48 D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
•
www.dorma.de
DORMA
Safety
WN 057014 45532
06/06
DORMA
Safety advice
GB
1. Intended application
Door operators are only designed to open and close doors.
Small children are not allowed to play with the systems/appliances.
Do not allow children to play with the systems or rigidly mounted adjustment and/or control
devices. Keep the remote controls out of reach of children
2. Product-specific characteristics
DORMA operators are applied as follows:
4at swing doors.
- DORMA CD 80
- DORMA ED 200
4at swing doors and at fire and smoke doors.
- DORMA CD 400
- DORMA ES 200
- DORMA ES 200 Easy 4at sliding doors.
4at sliding doors and at doors with application in emergency exits
- DORMA ES 200 2D
and escape routes.
3. Standards, laws, codes and regulations
The latest versions of the common and country-specific standards, laws, codes and
regulations have to be observed.
4. Limitation of liabilityg
The operator must only be applied according to its intended application.
The DORMA GmbH + Co. KG does not accept any liability for damages resulting from
unauthorized modifications of the system.
5. Documentation
IMPORTANT INSTRUCTIONS FOR THE SAFE INSTALLATION OF THE SYSTEM.
ALL INSTRUCTIONS MENTIONED IN THE DOCUMENTATION HAVE TO BE OBSERVED.
(e.g. an envelope reading documentation)
AN INCORRECTLY PERFORMED INSTALLATION MIGHT ENTAIL SERIOUS INJURIES.
TO INSURE THE PROPER SAFETY OF PEOPLE, IT IS IMPORTANT TO ABIDE BY THESE
INSTRUCTIONS.
THESE INSTRUCTIONS HAVE TO BE KEPT.
6. General information regarding the installation
Required preparation on site
The working area has to be secured against unauthorised access from other people.
Falling items or tools might cause injuries.
In any case, the way of installation and the mounting equipment, like screws and wall plugs,
have to be adequate with regard to the structural conditions (steel structure, wood, concrete etc.)
Before the installation of the operator, the door leaf/door leaves has/have to be checked for
proper mechanical condition and smooth running. .
5
DORMA
Safety
Following installation
Following installation, the setting and the proper function of the operator and the safety
devices have to be checked.
The installation instructions of this operator are only an example. Structural or local
conditions, available tools or other conditions might suggest a different approach. .
7. Residual risks
Automatic doors might cause hazards by crushing, shearing, hitting and drawing-in.
Depending on the structural conditions, the door version and the available safety measures,
residual risks cannot be excluded. Like for example by a force-limited hit or crushing.
Opposite closing edge
Secondary closing edge
Main closing edge
Main closing edge
Secondary closing edge
8. Maintenance and care
Before the first commissioning and depending on requirements, however, at least once a year,
the system has to be checked by a properly qualified technician and serviced if required.
The system has to be serviced at regular intervals by a specially trained person in accordance
with the manufacturer's instructions.
(According to the guidelines for power-operated doors, windows and gates. BGR (Federal
Institute for Geosciences and Natural Resources) 232/DIN 18650)
The operator has to be switched off and secured against unauthorized switching on before
performing maintenance work (cleaning or maintenance).
We would recommend to take out a maintenance contract with DORMA.
DORMA GmbH + Co.KG
6
Postfach 40 09 D-58247 Ennepetal • Breckerfelder Straße 42-48 D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
•
www.dorma.de
ED 200-D
WN 057023 45532
01 06/06
DORMA
a
b
c
4 3
1
2
1
34
7
7
2a
8
8
24
32,5
H2
19
25,5
46,5
69
54
100
X
176
315
58
69
384,5
299,5
133
50
Var.
X
01 -40 - 120mm
02 80 - 240mm
03 240 - 360mm
82
H1
584
530
H1 + 17
Var. 01, 02, 03
106
50
H1
584
530
69
315
384,5
299,5
100
176
46,5
97,5
79,5
70,5
30
21
122,5
73
48
H2
144,5
25,5
H1
19
24
95
69
54
WN 057023 45532
02 06/06
DORMA
ED 200-D
33
34
24
35
H2
19
25,5
46,5
175
69
54
100
176
18,5
82
20
133
69
384,5
299,5
H1
584
530
106
598
598
H1
584
530
69
384,5
299,5
46,5
77
68
30
21
120
73
95
142
95
48
H2
25,5
24
H1
69
54
175
100
176
WN 057023 45532
03 06/06
DORMA
ED 200-D
2b
9
9
10
10
24
20,5
46,5
H2
54
max.15
max. 28
250
69
284,5
199,5
408
18,5
82
H1
20
133
584
530
525
23 (40)
598
106
100
100
598
H1
584
530
525
408
69
46,5
21
13
120
112
129
137
129
146
164
147
48
30
H2/40
20,5
24
H2/23
54
H1
250
284,5
199,5
WN 057023 45532
04 06/06
DORMA
ED 200-D
2c
33
ED 200-D
WN 057023 45532
05 06/06
DORMA
5
5
3
6
1.
2.
5
584
4
5
6
34
11
11
ED 200-D
WN 057023 45532
06 06/06
DORMA
7a
7b
7c
2.
5
1.
8
12
12
9
ED 200-D
WN 057023 45532
07 06/06
DORMA
10a
11a
6
12a
13a
90 o
3.
1.
2.
4.
3.
14a
13
13
ED 200-D
WN 057023 45532
08 06/06
DORMA
1.
DIN-L
10
DIN-R
10o
o
4 3
2.
10b
6
11b
1.
2.
12b
6.
2.
5.
4 3
2.
1.
5.
4.
4.
3.
13b
14
14
1.
ED 200-D
WN 057023 45532
09 06/06
DORMA
1.
DIN-L
10
DIN-R
10o
o
4 3
2.
3.
90o
6
10c
11c
2.
4 3
1.
1.
2.
90o
3.
3.
12c
13c
6
2.
4.
2.
4.
3.
1.
3.
1.
14c
15
15
ED 200-D
WN 057023 45532
10 06/06
DORMA
X1
X2
X2 max
EN 4-6 1100 mm 1400 mm
EN 7
1600 mm
x1
o
115 - 25
o
4 3
9
11,1
o
1
43
1 2
15
16
25o - 0o
4 3
1
2
18
17
12 11 13
13 12 11
19A
16
16
A
B
C
A
B
19B
2
ED 200-D
WN 057023 45532
11 06/06
DORMA
max. 115o
A
B
C
B
20
21
X3
X4
B
X16
X6
A
B
0o - 75o
K4
S2
OFF ON
1
2
3
4
5
K2
D1
4 3
K3
X8
1
X7
222
51 50 7 8 49 48 25 26 27 47 46 13 11 45 12
2
23
A
75o - 115o
4 3
11,1o
24
1
2
B
25
17
17
ED 200-D
WN 057023 45532
12 06/06
DORMA
ED 200
43
1 2
27
Änderungen vorbehalten
Subject to change without notice
26
18
18
DORMA GmbH + Co.KG
Automatic Division
Postfach 40 09 D-58247 Ennepetal • Breckerfelder Straße 42-48 D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
•
www.dorma.com
WN 057024 45532
01 12/06
DORMA
ED 200-D
MONTAGE / EINSTELLUNG / INBETRIEBNAHME
Elektroinstallation:
a
Arbeiten an Elektroanlagen dürfen nur von
geschulten Fachkräften ausgeführt werden.
Die Elektroinstallation (230 VAC ± 10%, 50/60 Hz) ist
bauseits zu erstellen.
In die Zuleitung ist in Türnähe ein Not-Aus Schalter nach
VDE 0660 Teil 207 zu setzen.1)
Der Antrieb wird werkseitig mit einem Schukostecker
ausgeliefert. Zum Anschluß muß eine Schuko-Steckdose
mit 10 A - Absicherung vorhanden sein.
Wird der Steckeranschluß nicht verwendet, ist bauseits
die Stromzuführung so zu legen, daß die Kabel im
Bereich des Langlochs der Grundplatte aus der Wand
austreten.
In diesem Fall ist ein allpolig abschaltbarer Hauptschalter
zu setzen.1)
b
Feuer-/Rauchschutztüren:
Der ED 200 ist vom Institut für Bautechnik, Berlin, für
die Verwendung an Feuer-/Rauchschutztüren zugelassen.
Ein Eignungsnachweis für die jeweilige Feuer-/
Rauchschutztür in Verbindung mit ED 200 ist zusätzlich
erforderlich.
Der ED 200 ist gemäß der Zeichnung aus dem
Zulassungsbescheid des Türenherstellers anzubringen.
Wird der ED 200 in Feststellanlagen verwendet, ist es
erforderlich, gemäß den "Richtlinien für Feststellanlagen"
Rauchmelder zu installieren. Im System zugelasene
Rauchmelder können direkt an dem Sturzmelder
angeschlossen werden. Diese können am Antrieb mit
Steuerung „B“ direkt angeschlossen und mit einer
Spannung von 24V DC versorgt werden.
c
Vorbereitung
1
Maßbild: Montage auf der Bandgegenseite
(mit Normalgestänge)
2b
Maßbild: Montage auf der Bandgegenseite
(mit Gleitschiene)
2c
Maßbild: Montage auf der Bandseite
(mit Gleitschiene)
3
Auslieferungszustand des Antriebs kann bei Montage
auf eine andere DIN-Richtung der Tür umgerüstet
werden indem die Schaltelemente (Nockenscheiben
und Microschalter) auf die andere Achsseite montiert
werden..
4
Kunstoff-Spreizmutter heraushebeln und Endkappe
abschrauben.
Montage Antriebseinheit
Der Antrieb ist mit 2 Montagehilfschrauben und
mind. mit weiteren 6 Schrauben zu befestigen.
Bei Stahl-Profilen Kerndurchmesser bohren und
Gewinde (M6) schneiden.
Bei LM-Profilen Einnietmuttern (M6) verwenden.
5
2-flügelige Türen
Bei der Montage des ED 200 an 2-flügeligen Türen ist
1 Antrieb mit Steuerung A und 1 Antrieb mit Steuerung B
erforderlich. Die Montage des Antriebs mit Steuerung B
erfolgt am Gangflügel.
Bauliche Gegebenheiten
Für besondere bauliche Gegebenheiten ist folgendes
Zubehör lieferbar:
Montageplatte wenn eine Direktmontage, bedingt durch Glasfelder,
schmale Zarge usw., nicht durchführbar ist.
Verlängerte Hebelaugen zum Ausgleich von Höhendifferenzen.
Gestängevarianten zum Ausgleich von unterschiedlichen Sturztiefen.
1)
Abdeckhaube von der Antriebseinheit abnehmen.
2a
Weitere Hinweise/Vorschriften:
Merkblatt über die Verwendung von
Feststellanlagen.
Richtlinien für Feststellanlagen des Instituts für
Bautechnik, Berlin.
ED 200 mit Normalgestänge Montage auf der Bandgegenseite
ED 200 mit Gleitschiene Montage auf der Bandgegenseite
ED 200 mit Gleitschiene Montage auf der Bandseite
Bei Feuer-/Rauchschutztüren ist der ED 200
gemäß der Zeichnung aus dem Zulassungsbescheid des Türenherstellers anzubringen.
Löcher für Montagehilfsschrauben nach
Maßzeichnung anzeichnen und bohren und ggf.
Gewinde schneiden.
Montagehilfsschrauben eindrehen.
Abstand zwischen Schraubenkopf und
Sturz- bzw. Rahmenfläche = 6 mm.
6
Antriebseinheit auf die Montagehilfsschrauben
hängen.
7a
7b
7c
Löcher für Befestigungsschrauben durch die
Grundplatte der Antriebseinheit anzeichnen.
Antriebseinheit abnehmen.
Lochgruppe für Scharnier / Gleitschiene nach
Maßbild anzeichnen.
Löcher bohren und ggf. Gewinde schneiden.
8
Antriebseinheit wieder einhängen.
Befestigungsschrauben (+Zahnscheiben) eindrehen
und festziehen.
Montagehilfsschrauben festziehen.
9
Endkappe anschrauben und Kunstoff-Spreizmutter
eindrücken.
gemäß Richtlinien für kraftbetätigte Fenster,
Türen und Tore
19
19
WN 057024 45532
02 12/06
DORMA
ED 200-D
Montage Gestänge (Bandgegenseite)
10a Spannschraube des Hebels zusammenschrauben.
in Hebel einsetzen - Stellung des
11a Hebelauge
Vierkants zum Hebel beachten.
Hebelauge mit einem Hammer und einer
Hartholzleiste o.ä. bis zum Anschlag eintreiben.
12a Hebel im rechten Winkel zum Türrblatt auf
Antriebsachse stecken und mit Zylinderschraube
M 8 (incl. Scheibe und Zahnscheibe) befestigen.
der Spannschraube mit 2 Schrauben am
13a Scharnier
Türblatt befestigen.
soweit heraus-/ hineindrehen, daß
14a Spannschraube
im zusammengeclipsten Zustand des Gestänges die
Spannschraube rechtwinklig zum Türblatt steht.
Spannschraube und Hebel zusammenclipsen.
Mit Sechskantmutter kontern.
Montage Gleitschiene (Bandgegenseite)
auf Hebelauge:
10b Markierung
L = Hebelauge für DIN-links-Türen,
R = Hebelauge für DIN-rechts-Türen.
Hebelauge in Hebel einsetzen - Stellung des
Vierkants zum Hebel beachten.
Hebelauge mit einem Hammer und einer
Hartholzleiste o.ä. bis zum Anschlag eintreiben.
Gleitschiene für die Montage vorbereiten.
3 und 4 schließen.
11b Ventile
Hebel im Winkel von 45° zum Türrahmen auf die
Antriebsachse stecken und mit
Zyl.Schraube,Scheibe und Federring befestigen.
12b Gleitschiene auf das Gleitstück am Hebel schieben.
auf Gleitschiene stecken.
13b Endstücken
Gleitschiene am Türblatt befestigen.
16
17
Ausführung ED 200 mit werksseitig eingebauter
Steuerung:
Bei doppelflügeligen Türen Steuerungen über Kabel
verbinden.
Zusätzliche Komponenten, soweit vorhanden, an die
Steuerung anschließen.
Siehe hierzu Klemmenbelegung/Anschlußpläne.
Weiter mit Bild 20.
Einbau Steuerung
Steuerung A = Standard-Steuerung
Steuerung B = Comfort-Steuerung
Kombischrauben in die Zylindereinheit eindrehen.
Alle Kabel nach vorn legen. Platinenhalter mit
Steuerungsmodul (Typ A oder B) unter die
Schraubenköpfe schieben und befestigen.
aufstecken.
19A Stecker
Für die folgenden Punkte siehe auch
19B Klemmenbelegung/Anschlußpläne.
Kabel vom Programmschalter an Steuerung
anschließen.
Bei doppelflügeligen Türen Steuerungen über Kabel
verbinden. Zusätzliche Komponenten, soweit
vorhanden, an die Steuerung anschließen.
einstellen - hierzu Tür im
20 Türöffnungswinkel
gewünschten Öffnungswinkel festsetzen und die
schwarze Nockenscheibe mit beigefügtem Stift
soweit verdrehen, daß der Mikroschalter betätigt
wird.
18
Ventile 3 und 4 öffnen.
Montage Gleitschiene (Bandseite)
auf Hebelauge:
10c Markierung
L = Hebelauge für DIN-links-Türen,
R = Hebelauge für DIN-rechts-Türen.
Hebelauge in Hebel einsetzen - Stellung des
Vierkants zum Hebel beachten.
Hebelauge mit einem Hammer und einer
Hartholzleiste o.ä. bis zum Anschlag eintreiben.
Gleitschiene für die Montage vorbereiten.
3 und 4 schließen.
11c Ventile
Hebel im Winkel von 45° zum Türrahmen auf die
Antriebsachse stecken und mit Zyl.Schraube +
Scheibe gegen Abrutschen sichern.
Hebel um 90° in Richtung Türband aufziehen
(vorspannen). Hebel bleibt stehen.
von Achse demontieren, um 90° zurück in die
12c Hebel
vorherige Position umsetzen und mit
Zylinderschraube Scheibe und Federring befestigen.
auf das Gleitstück am Hebel schieben.
13c Gleitschiene
Ventile 3 und 4 öffnen.
Die Gleitschiene legt sich an das Türblatt an.
auf Gleitschiene stecken.
14c Endstücken
Gleitschiene am Türblatt befestigen.
15 Schließkraft über Stellschraube einstellen (nicht bei
Größe EN7). Bei der Ausführung ED 200 mit
werksseitig eingebauter Steuerung ist diese, falls
erforderlich, zu lösen. Die vorgeschriebene Kraft an
der Hauptschließkante der Tür ist auf 150 N zu
begrenzen.
Eine zu hoch eingestellte Schließkraft kann
zu Verletzungen von Personen führen.
20
20
Schließgeschwindigkeit im Bereich 115°-25° über
Ventil 3 einstellen.
Schließdämpfung im Bereich 25°- 0° über Ventil 4
einstellen.
21
22
Der Schaltpunkt muß vor dem maximal
möglichem Türöffnungswinkel (115°) liegen,
damit der Motor abschalten kann.
Bei Steuerung Typ "B" Betriebsartenschalter
einstellen:
A = Einflügeliger Türbetrieb
B = Zweiflügeliger Türbetrieb
C = Türbetrieb mit Motorschloß
Netzschalter und Programmschalter auf "AUS"
stellen. Netzstecker einstecken.
Alle DIP-Schalter von S2 auf „OFF“ stellen.
Erst wenn die Anlage funktioniert diese
entsprechend den Anforderungen einzeln
einstellen und der Reihe nach die Anlage auf
ihre Funktionstüchtigkeit überprüfen.
Not-Aus Schalter (meist in der Nähe der Tür)
entriegeln. Netzschalter auf "EIN" stellen.
Programmschalter auf "AUTOMATIK" stellen.
Ca. 3 Sekunden leuchten auf der Steuerung B die
Fehler - LEDs, abhängig von der Stellung S1
( LED A direkt neben dem Relais K4 zeigt den
Fehlerzustand der Steuerung A an )
( LED B direkt daneben zum Prozessor D1 zeigt
den Fehlerzustand der Steuerung B an )
Nach dem Erlöschen der LED´s sind die Steuerungen
B und A betriebsbereit
Die Steuerung B überwacht während des Betriebes
sowohl die Steuerung A als auch sich selbst.
WN 057024 45532
03 12/06
DORMA
23
24
25
26
ED 200-D
Der Schalter Wandausblendung darf in
Zuposition nicht betätigt sein, sonst wird
Sensorfehler 4 x blinken angezeigt, und die
Tür fährt nicht auf.
Abhilfe: Nocke Wandausblendung justieren.
Für die folgenden Einstellungen Öffnungsimpuls
über einen externen Impulsgeber (z.B. Radarmelder)
geben und Bewegungsablauf beobachten / regulieren.
Öffnungsgeschwindigkeit im Bereich 0°-75°über
Ventil 1 einstellen.
Öffnungsdämpfung im Bereich 75°-115° über Ventil
2 einstellen.
Gewünschte Offenhaltezeit (0 - 30 sek.) über
Potentiometer einstellen.
Hinweis: Damit die Tür die "Offen-Position" erreicht,
muß die eingestellte Offenhaltezeit größer sein als
die über Ventil 1 und 2 eingestellte Öffnungszeit.
Die eingestellte Offenhaltezeit beginnt abzulaufen,
sobald ein Impuls gegeben wird.
Option: Sicherheitsleiste auf der Bandseite.
Wenn erforderlich, Ausblendbereich für die
Sensorleiste über die weiße Nockenscheibe
einstellen. Nockenscheibe mit beigefügtem Stift
soweit verdrehen, daß der Mikroschalter betätigt
wird. Darauf achten, daß die schwarze
Nockenscheibe nicht verstellt wird.
Hinweis: An diesem Punkt schaltet die IRSSensorleiste in Richtung "Öffnen" zur Ausblendung
eventueller Hindernisse ab und erkennt für diesen
Bereich kein Hindernis mehr.
Es ist darauf zu achten, daß die
Nockenscheibe in der gewählten Einstellung
nicht den Endschalter auch in der ”Tür Zu”
Position betätigt.
Die Einstellung vorhandener Impulsgeber (z.B.
Radar-melder) / Sensorleisten erfolgt gemäß der
jeweiligen Montageanleitung.
O Option: Öffnungsimpulsgeber "Nacht-Bank".
Tür entriegelt und öffnet nach Impuls in der
Programmschalterstellung "Aus" und schließt nach
einer Offenhaltezeit von ca. 5 Sek. selbständig.
O Option: IRS - Sensorleisten
Bei eingeschalteten DIP Switches werden die
externen IR-Sensorleisten auf ihre Funktion getestet.
Hierbei gilt folgende Zuordnung:
S2 Grundeinstellung: alle OFF
O
O
O
Folgende Programmschalterstellungen sind möglich:
Programmschalter am Gerät:
Automatik - Aus - Daueroffen
Programmschalter extern:
Aus - Ausgang - Daueroffen - Automatik
(nur in Verbindung mit Steuerung B).
Öffnungsimpulsgeber für den Innenbereich prüfen.
Tür öffnet nach Impuls in den Programmschalterstellungen "Automatik" und"Ausgang" und schließt
nach Ablauf der eingestellten Offenhaltezeit.
Öffnungsimpulsgeber für den Außenbereich prüfen.
Tür öffnet nach Impuls in der Programmschalterstellung "Automatik" und schließt nach Ablauf der
eingestellten Offenhaltezeit.
ON = Test low aktiv
2 OFF = inaktiv Test GF BS
ON = aktiv Test GF BS (14/15)
3 OFF = inaktiv Test GF BGS ON = aktiv Test GF BGS (52/53)
4 OFF = inaktiv Test SF BS
O
O
Funktionprüfung
O
1 OFF = Test high aktiv
ON = aktiv Test SF BS (54/55)
5 OFF = inaktiv Test SF BGS ON = aktiv Test SF BGS (61/62)
Bandseite:
Befindet sich ein Hindernis im Erfassungsbereich der
IRS-Sicherheitsleiste:
- stoppt die Tür während der Öffnungsfahrt
- bleibt die Tür geschlossen, wenn sie sich in der
Tür-Zu-Position befindet.
Ist der Überwachungsbereich wieder frei, nimmt der
Antrieb seinen normalen Betrieb wieder auf.
Bandgegenseite
Befindet sich ein Hindernis im Erfassungsbereich
der IRS-Sicherheitsleiste:
- reversiert die Tür bei der Schließfahrt
- bleibt die Tür in geöffneter Position stehen.
Ist der Überwachungsbereich wieder frei, nimmt der
Antrieb seinen normalen Betrieb wieder auf.
Steuerung B schaltet die Sensorleiste nach 5 Sek.
ab. Sie ist erst aktiviert, wenn die Tür geöffnet wird.
O
Option: Verriegelung
Die Tür ist im geschlossenen Zustand verriegelt.
Bei jeder Aktivierung eines Öffnungsimpulsgebers
wird die Tür entriegelt (Entriegelungszeit 1 sek.) und
öffnet.
O
Option: Motorschloßverriegelung SVP 2xxx
(nur in Verbindung mit Steuerung B).
Die Tür ist im geschlossenen Zustand verriegelt.
Bei jeder Aktivierung eines Öffnungsimpulsgebers
wird das Motorschloss entriegelt und die Tür öffnet.
Restmontage
27
Schutzleiterkabel aufstecken.
Abdeckhaube aufsetzen und anschrauben.
Firmen-Logo anbringen.
Änderungen vorbehalten
Bei der Montage ist auf die Absicherung der
Nebenschließkante zu achten!
Einweisung
Nach erfolgter Einstellung / Inbetriebnahme der
Türanlage ist die Bedienungsanleitung dem Betreiber
auszuhändigen und eine Einweisung durchzuführen.
DORMA GmbH + Co.KG Postfach 40 09
D-58247 Ennepetal • Breckerfelder Straße 42-48
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
D-58256 Ennepetal
• www.dorma.com
21
21
WN 057024 45532
05 12/06
DORMA
ED 200-D
INSTALLATION / ADJUSTMENT /
COMMISSIONING
Electrical installation:
b
Electrical installation work must only be
performed by suitably qualified and trained
personnel.
Ensure compliance with local regulations
The electrical installation work (230 vAC ± 10%, 50/60
Hz) is performed by others.
According to German regulations 1), an emergency-off
pushbutton (VDE 0660, part 207) must be installed in the
power supply line (feeder cable) close to the door. Check
also local regulations.
The operator (drive unit) is supplied complete with a
2-pole-and-earth mains plug (German Schuko type
available). An earthed outlet socket fused at 10 A must be
provided by others.
If earthed outlet sockets are not available, the mains
feeder cable must be externally positioned to install a
lockable main switch. From the main switch the feeder
cable is connected to the operator through the baseplate.
The main switch must disconnect all poles from the mains.
Fire and smoke rated doors:
The ED 200 is approved for installation on fire and smoke
rated doors according to the German Institute for Building
Technology, Berlin. An approval certificate for the fire /
smoke rated door is additionally required. The ED 200
must be installed in accordance with the approved and
certificated drawings and templates provided by the
manufacturer of fire and smoke rated door.
If the ED 200 is used in conjunction with hold-open
systems, a smoke detector is required (acc. to the German
regulations for hold-open systems – check also local
regulations). The smoke detectors can be connected
directly to the ED 200 with control module B, and powered
with a supply of 24 VDC (stabilised).
Instruction sheet relating to the use and application for
hold open device systems. 2)
Guidelines for hold open systems published by the
Institute for Building Technology Berlin 2)or
equivalent national guidelines.
Fixing to double doors
When fixing to double doors, it is important to ensure that
the ED 200 is installed with control module A on the
inactive leaf and with control module B on the active leaf.
On-site requirements
The following accessories are available for special on-site
installations:
Mounting backplate for indirect fixing due to presence of glass panels, narrow
frame, etc..
Various sizes of spindle extension for overcoming height differentials.
Arm variants for accommodating different reveal depths/door types.
1)
2)
22
a
c
ED 200 with standard arm Installation on push side (opposite hinge side)
ED 200 with slide channel Installation on push side (opposite hinge side)
ED 200 with slide channel Installation on pull side (hinge side)
Preparation
1
2a
2b
2c
3
4
Remove cover from the operator.
Dimensional drawing: Installation on push side
(opposite hinge side) with standard arm
Dimensional drawing: Installation on push side
(opposite hinge side) with slide channel
Dimensional drawing : Installation on pull side
(hinge side) with slide channel
Standard setting on delivery is for right-hand
(DIN-R, ISO 5, CW closing) doors
To fit the operator to a left-hand door, the
microswitch and the cam must be refitted on the
other end of the spindle.
Pull out the plastic nut and unscrew the end cover.
Installing the operator
Secure the operator with 2 auxiliary mounting screws
and a minimum of a further 6 fixing screws.
When using steel profile sections drill pilot hole of
core diameter and tap thread (M 6).
When using LM profiles (aluminium alloy sections),
use riv-nuts (M 6).
5
In the case of fire/smoke rated doors, the
ED 200 must be installed in accordance with
the approved and certificated drawings and
templates provided by the door manufacturer.
Mark out and drill the holes for the auxiliary
mounting screws in accordance with the dimensioned
drawing and tap the thread if required.
Fix the auxiliary mounting screws
Distance between screw head and reveal or frame
surface = 6 mm.
6
Fix the operator to the auxiliary mounting screws.
7a
7b
7c
8
9
Mark out the holes for the fixing screws through the
baseplate onto the frame section.
Remove operator from baseplate.
Mark out the holes for the arm bracket /slide channel
in accordance with the dimensioned drawing.
Drill the holes and tap the tread if required.
Re-fit the operator.
Wind in the fixing screws (+ serrated lock washers)
and fix tightly.
Tighten the auxiliary mounting screws.
Fit the end caps and press in plastic nut.
As specified in German guidelines for power-operated
windows, doors and gates
These documents are only printed in German as they refer
exclusively to German market.
23
WN 057024 45532
06 12/06
DORMA
ED 200-D
Arm installation (opposite hinge side)
15 Fix slide channel and adapter plate to door leaf (not
applicable when using soundproof version)..
Set closing force using adjustment screw on side of
operator (not size EN 7).
If the ED 200 has a factory-fitted control module, this
may have to be detached.
Maximum force at main closing edge must not exceed
150 N 1)
10a Connect the two components of the standard arm.
spindle extension into arm. Ensure that the
11a Fit
position of the square section insert relative to the
arm is correct.
Tap the spindle extension home using a rubber
mallet, hammer and wooden block or similar.
12a Place the main arm onto the drive spindle so that it is
at right angles to the door frame, and secure with
washer, spring washer and cheesehead screw.
the arm fixing bracket with two screws to the
13a Secure
door leaf.
or unwind the adjustment screw so that, when
14a Wind
the arm sections are connected, the lower arm is at
right angles to the door.
Clip main arm and lower arm together.
Secure the adjustment screw with the lock nut.
Forces higher than 150 N can cause injury.
16
17
ED 200 operator with factory-fitted control module:
In the case of double doors, link the control modules
by interconnecting cable.
Connect any auxiliary components and accessories to
the control module as appropriate.See relevant
terminal assignment and connection diagrams.
Continue from Fig. 20.
Slide channel arm installation (opposite hinge side)
on spindle:
10b Marking
L = Spindle extension for left-hand
(ISO 6, CCW closing) doors
R = Spindle extension for right-hand
(ISO 5, CCW closing) doors
Fit spindle extension into arm. Ensure that the
position of the square section insert relative to the
arm is correct.
Tap the spindle extension home using a rubber
mallet, hammer and wooden block or similar.
Prepare sliding track for installation.
valves 3 and 4.
11b Close
Position arm at an angle of 45° to door frame and fit
over operator spindle and fix with cheesehead screw,
washer and spring washer.
12b Fit slide channel over slide shoe.
end caps on slide channel.
13b Fix
Fix slide channel and adapter plate to door leaf.
(adapter plate isn´t applicable when using soundproof
version)
Open valves 3 and 4.
Fixing of controlboard
Control module A = Standard control
Control module B = Enhanced control
Fix control module plus transformer with two screws to
operator cylinder unit. Adjust wires so that cover can
be fitted without damaging them.
Fit connectors to control module.
individual terminal assignments/connection
19AConsult
diagrams in performing the following operations.
19B Connect programme switch wires to control module.
In the case of double doors, link the control modules
by interconnecting cable.
Connect any auxiliary components and accessories to
the control module as appropriate.
door opening angle: Move door leaf to required
20 Adjust
open position and adjust black cam using pin supplied
until the cam activates the microswitch. Fix cam in
this position.
18
Slide channel arm installation (hinge side)
on spindle:
10c Marking
L = Spindle extension for left-hand
(ISO 6, CCW closing) doors
R = Spindle extension for right-hand
(ISO 5, CCW closing) doors
Fit spindle extension into arm. Ensure that the
position of the square section insert relative to the
arm is correct.
Tap the spindle extension home using a rubber
mallet, hammer and wooden block or similar.
Prepare sliding track for installation.
11c Close valves 3 and 4.
Position arm at an angle of 45° to door frame and fit
over operator spindle with cheese head screw to
prevent it from slipping off.
Rotate arm 90° in hinge direction (preload).
Leave arm in this position.
arm from spindle, refit at original position
12c Remove
(45° to door leaf) and fix with cheesehead screw,
washer and spring washer.
slide channel over slide shoe.
13c Fit
Open valves 3 and 4.
Slide channel is automatically pushed against door
leaf.
Fix end caps on slide channel.
Adjust closing speed in the range of 1150 - 250 by
valve 3.
Adjust closing damping in the range of 250 - 00 by
valve 4.
21
22
Switch must be activated at an angle less
than 115° (max. door opening angle) to allow
motor pump to switch off.
If using control module "B" adjust mode switch
A = single door mode
B = double door mode
C = application with motor lock
Set both mains switch and program switch to "OFF".
Connect to mains.
Set all DIP switches from S2 to “OFF“ position.
Adjust the system to your individual
requirements only when it is fully functional
then check one feature of the system after the
other for proper function.
Unlatch Emergency Off pushbutton (mostly located in
the close range of the door) and set the power switch
to "ON" position.
Set the program switch to "AUTOMATIC” position.
14c
24
23
DORMA
ED 200-D
WN 057024 45532
07 12/06
After approx. 3 seconds, the error LEDs on
control unit B will light up, depending on the position
of S1.
(LED A, located direct next to relay K4, indicates the
error status of control unit A.)
(LED B, located direct next to processor D1,
indicates the error status of control unit B.)
Control unit A and B are ready for operation
immediately after the LEDs went out.
Control unit B monitors both control unit A and itself
during operation.
23
24
25
26
O
The external infrared safety sensors are tested for
proper function when the DIP switches are switched
on. The following allocation is valid:
S2 basic setting: all OFF
The switch for the wall blanking must not be
activated while the door is in "closed"
position, otherwise a sensor error is indicated
(LED blinks 4 times) and the door does not
open.
Remedy: Adjust the cam for the wall blanking.
o
o
Opening speed adjustable at valve 1 in the range 0 - 75 .
Delayed action adjustable at valve 2 in the range 750
- 1150.
Adjust hold open time by potentiometer in the range
from 0 - 30 secs.
Note: For the door to reach the open position, the
hold-open time must be adjusted to a larger value
that the total time set at valves 1 and 2. The holdopen time starts with the activation signal.
Option IRS safety sensor on hinge-side.
If necessary use white cam to adjust the blanked
range of the IRS sensor (i.e. area for which sensor is
disabled). Turn the cam with the pin supplied until
the microswitch is activated. Ensure that the position
of the black cam remains unchanged.
Note: As the door opens to this point, the hinge-side
IRS sensor ceases to operate so that the door is not
tripped by obstacles in the blanked range.
O
O
Ensure that the white cam, once adjusted,
does not also activate the limit switch in the
“Door Closed” position.
Sensors in accordance with the relevant fixing
instructions.
Functional checks
O
O
O
O
O
Possible programme switch settings:
Programme switch integrated in ED200:
Automatic - OFF - Permanent open
External programme switch:
OFF - Exit only - Permanent open - Automatic
(only possible with control module B).
Check internal activator.
Door opens after signal emission in “Automatic” and
“Exit only” modes, and closes after hold-open time.
Check external activator.
Door opens after signal emission in “Automatic” and
and closes after hold open time.
Option: ”Night Bank” activator.
Door unlocks and opens on signal emission with
programme switch set to “OFF”. After approx. 5
seconds, door closes again automatically.
Option: IRS safety sensor
O
O
1 OFF = Test high active ON = Test low active
2 OFF = Test of active leaf, hinge side not activated
ON = Test of active leaf, hinge
side activated (14/15)
3 OFF = Test of active leaf, opposite hinge side not activated
ON = Test of active leaf,
opposite hinge side activated (52/53)
4 OFF = Test of passive leaf, hinge side not activated
ON = Test of passive leaf, hinge
side activated (54/55)
5 OFF = Test of passive leaf, opposite hinge side not activated
ON = Test of passive leaf,
opposite hinge side activated (61/62)
Hinge-side:
If the IRS detects an obstacle (person) in its
detection range
- doors stops moving during the opening cycle
- door stays closed if already in closed position
Once the detection range is free, the operator is reenabled and continues operation in the preset mode.
Opposite hinge side:
If the IRS detects an obstacle (person) in its
detection range
- door reverses during closing cycle
- door stays open if already in open position
Once the detection range is free, the operator is
re-enabled and continues operation in the preset
mode. The IRS on the opposite hinge side is switched
off automatically by control module B after 5 sec.
and reactivated only when door starts moving again.
Option: Locking system (electric strike plate), fail
safe, fail secure
Door is locked in closed position. If operator is
activated, door will unlock and move leaf to open
position (fixed unlocking signal pulse duration of 1
sec.)
Option: Motorlock SVP 2xxx
(only available with control module B).
Door is locked in closed position. If operator is
activated, motor lock unlocks and operator opens
the door.
Completion
27
Connect earthing cable
Install cover and fix with two screws.
Fix DORMA and ED 200 labels
Pay attention to protecting the secondary
closing edge during installation
User familiarisation
After commissioning and adjustment of the operator
and accessories, the operating instructions must be
handed to the owner/user and the owner/user properly
familiarised with the system.
24
25
WN 057025 45532
01 12/06
DORMA
ED 200-D
35 34 6 5 2 4 1
33
32
31
L1
37
36 39
N
38 X5
X1 X3
X4
X2
X6
A
F2 F3
X7
X8
X9
D
44
43
42 N
41 V
40 U
R4
21
20
19
18
17
16
25 26 27 14 15 7 8 11 12 13
Technische Daten
Versorgungsspannung:
Sicherung F2:
Sicherung F3:
230 VAC ±10%, 50/60 Hz
T 0,8 A bei 24 VAC
T 0,8 A bei 12 VAC
Klemmenbelegung Steuerung A
X1
1
4
2
5
6
34
35
- 24 VDC
+ 24 VDC
Versorgungsspannung für externe Verbraucher,
z.B. Verriegelung
1+2 = 24 VAC, 2+4 = 12 VAC.
Treibriegelendschalter / Rauchmelder oder
Brücke (wenn Anschluß unbenutzt).
Versorgungsspannung für externe Verbraucher,
z.B. Verriegelung (max. 400mA)
Max. 700 mA
X2
31
32
33
24 V
12 V
0V
Sekundärer Trafoanschluß
X3
36
37
Primärer Trafoanschluß
X4
38
39
N
L1
Netzanschluß: 230 VAC ±10%, 50/60 Hz
U
V
W
Motor
X5
40
41
42
43
44
6µF
Kondensator
X6
16
17
18
19
20
21
Endschalter "Tür auf"
Magnetventil
Endschalter Wandausblendung:
Schaltet die bandseitige Sicherheitseinrichtung aus.
X7
Automatik
Aus (GND)
Daueroffen
13
12
11
8
7
15
14
27
26
25
X8
R4
Programmschalter
Impulsgeber (Innenmelder, Außenmelder, IRS-Sensorleiste auf Bandgegenseite)
Sicherheitseinrichtung Bandseite (z.B. IRS-Sensorleiste), oder Brücke (wenn Anschluss unbenutzt).
C
NO
NC
X9
Elektromechanische Verriegelung: potentialfreier Kontakt (Wechsler), Impulsdauer 1 sek.
5 + 2-poliger Anschluß zur Verbindung der Steuerungen
bei zweiflügeligen Türantrieb.
Steuerungstyp B (Master / Gangflügel) steuert
Steuerungstyp A (Slave / Standflügel)
Offenhaltezeit 0 - 30 sek
25
27
ED 200-D
WN 057025 45532
02 12/06
DORMA
L1
31 32 33 35 34 6 5 2 2 4 4 1 1 37
X13
59
60
18K
X3
X2
X1
36 39
N
38 X5
F2
B
F3
58
57
56
R26
X6
X11
A
21
20
19
18
17
16
B
X10
S1
A B C
S2
X14
X8
X9
X15
D
44
43
42 N
41 V
40 U
X4
X7
Technische Daten
Versorgungsspannung: 230 VAC ±10%, 50/60 Hz
Sicherung F2:
T 1,6 A bei 24 VAC
Sicherung F3:
T 1,6 A bei 12 VAC
LED: A (V20)
Fehleranzeige Steuerung A
LED: B (V18)
Fehleranzeige Steuerung B
6162 55 54 14 15 53 52 51 50 7 8 49 48 25 26 27 47 46 13 11 45 12
Klemmenbelegung Steuerung B
X8
X1
31
32
33
24 V
12 V
0V
48
49
8
7
Sekundärer Trafoanschluß
Impulsgeber Nacht-Bank
Impulsgeber Innenbereich
X2
X9
1
1
4
4
2
2
5
6
34
35
Versorgungsspannung für externe Verbraucher,
z.B. Verriegelung
1+2 = 24 VAC, 2+4 = 12 VAC.
Treibriegelendschalter / Rauchmelder oder
Brücke (wenn Anschluß unbenutzt).
24 VDC Versorgungsspannung für externe Verbraucher,
24 VDC max. 700 mA.
max. 1400 mA
50
51
52
53
15
14
54
Sicherheitsleiste Bandgegenseite Gangflügel
Sicherheitsleiste Bandseite Gangflügel
oder Brücke (wenn Anschluß unbenutzt).
Sicherheitsleiste Bandseite Standfügel.
oder Brücke (wenn Anschluss unbenutzt).
55
X10
X3
36
37
Impulsgeber Aussenbereich
X14
Primärer Trafoanschluß
5 + 2-poliger Anschluß zur Verbindung der
Steuerungen bei zweiflügeligen Türantrieb.
Steuerungstyp B (Master / Gangflügel) steuert
Steuerungstyp A (Slave / Standflügel).
X4
38
39
N
L1
Netzanschluß: 230 VAC ±10%, 50/60 Hz
56
18K 57
58
X5
40
41
42
43
44
X6
16
17
18
19
20
21
Änderungen vorbehalten
X7
12
45
11
13
46
47
27
26
25
U
V
W
Spannungsversorgung für Rauchmelder
(max. 100mA) - wird nicht durch Treibriegelendschalter abgeschaltet.
Abschalteingang
Motor
X13
Kondensator
59
60
6µF
Endschalter "Tür auf"
Magnetventil
Endschalter Wandausblendung:
Schaltet die bandseitige Sicherheitsleiste aus.
Test Ausgang Sensorik GF
Test Ausgang Sensorik SF
X15
61
62
R26
Aus (GND)
S1
Ausgang
Programmschalter
Daueroffen
Automatik
Endschalter "Tür zu" (Schaltet die Sicherheitsleisten auf der Bandgegenseite aus)
S2
Anschluß unbenutzt: Brücke verwenden.
OFF ON
Elektromechanische Verriegelung:
C
NO potentialfreier Kontakt (Wechsler),
NC Impulsdauer 1 sek.
DORMA GmbH + Co.KG
26
28
X11
Sicherheitsleiste Bandgegenseite Standflügel
Offenhaltezeit 0 - 30 sek.
Betriebswahlschalter:
Einflügeliger Türbetrieb
A
B Zweiflügeliger Türbetrieb
Türbetrieb mit Motorschloß
C
DIP Schalter Grundeinstellung alle “OFF”
OFF
ON
1 Test high aktiv
Test low aktiv
2 Inaktiv Test GF BS
Aktiv Test GF BS
2 Inaktiv Test GF BGS Aktiv Test GF BGS
4 Inaktiv Test SF BS
Aktiv Test SF BS
5 Inaktiv Test SF BGS Aktiv Test SF BGS
Postfach 40 09 D-58247 Ennepetal • Breckerfelder Straße 42-48 D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
•
www.dorma.com
WN 057025 45532
03 12/06
DORMA
ED 200-D
35 34 6 5 2 4 1
33
32
31
L1
37
36 39
X1 X3
N
38 X5
X4
X2
X6
A
F2 F3
X7
X8
X9
GB
44
43
42 N
41 V
40 U
R4
21
20
19
18
17
16
25 26 27 14 15 7 8 11 12 13
Tecnical data
Power supply:
Fuse F2:
Fuse F3:
230 VAC ±10%, 50/60 Hz
T 0.8 A at 24 VAC
T 0.8 A at 12 VAC
Connection blocks Control board A
X1
1
4
2
5
6
34
35
- 24 VDC
+ 24 VDC
Power supply to external loads,
e.g. electro-mechanical lock or radar detector
1+2 = 24 VAC, 2+4 = 12 VAC.
Drive unit disabling contact for e.g. smoke detector input;
jumper if not used
Power supply to external loads,
e.g. electro-mechanical lock or radar detector (max. 400 mA)
max. 700 mA
X2
31
32
33
24 V
12 V
0V
Secondary side, transformer
X3
36
37
Primary side, transformer
X4
38
39
N
L1
Incomimg power supply 230 VAC +-10%, 50/60 Hz
U
V
W
Motor
X5
40
41
42
43
44
6µF
Capacitor
X6
16
17
18
19
20
21
„Door open“ limit switch
Solenoid valve
„Door closed“ limit switch (cam)
Switches off the hinge-side safety sensor (e.g.IRS)
X7
Automatic
OFF (GND)
Permanent open
13
12
11
8
7
15
14
27
26
25
X8
Programme switch
Activators (internal detector, external detector, IRS sensor on opposite hinge-side)
C
NO
NC
X9
Hinge-side safety device (e.g. IRS sensor);
jumper if not used
Electro-mechanical lock:
Floating contact (change over contact),
fixed pulse duration of 1 sec.
5 + 2-pin interface block for connection cable linking two control
modules for coordinated double-leaf operation
Control module B (master/ active leave) controls
module A (slave/ inactive leave).
R4
Hold open time 0-30sec.
27
29
ED 200-D
WN 057025 45532
04 12/06
DORMA
L1
31 32 33 35 34 6 5 2 2 4 4 1 1 37
X13
59
60
18K
X3
X2
X1
36 39
N
38 X5
44
43
42 N
41 V
40 U
X4
F2
B
F3
58
57
56
R26
X6
X11
A
21
20
19
18
17
16
B
X10
S1
A B C
S2
X14
X8
X9
X15
X7
6162 55 54 14 15 53 52 51 50 7 8 49 48 25 26 27 47 46 13 11 45 12
Technical data
Power supply:
Fuse F2:
Fuse F3:
LED: A (V20)
LED: B (V18)
230 VAC ±10%, 50/60 Hz
T 1,6 A at 24 VAC
T 1,6 A at 12 VAC
Error indicator Steuerung A
Error indicator Steuerung B
Connection blocks Control board B
X8
X1
31
32
33
24 V
12 V
0V
48
49
8
7
Secondary side, transformer
Night-bank activator
Internal activator
X2
X9
1
1
4
4
2
2
5
6
34
35
Power supply to external loads,
e.g. electro-mechanical lock (radar
detector) 1+2 = 24 VAC, 2+4 = 12 VAC.
Drive unit disabling contact for e.g.
smoke detector input; jumper if not used
24 VDC Power supply to external loads,
24 VDC e.g. electro-mechanical lock (max 700mA).
max. 1400 mA
50
51
52
53
15
14
54
Safety sensor, opposite hinge-side
Safety sensor hinge-side active leaf;
jumper if not used
Safety sensor hinge-side inactive leaf
Jumper if not used
55
X10
X3
36
37
External activator
X14
Primary side, transformer
5 + 2-pin interface block for connection cable
linking two control modules for coordinated
double-leaf operation
Control module B (master/ active leaf)
Controls module A (Slave/ inactive leaf).
X4
38
39
N
L1
Incoming power supply:
230 VAC ±10%, 50/60 Hz
U
V
W
Motor
X5
40
41
42
43
44
6µF
X11
56
18K 57
58
X13
59
60
Capacitor
Subject to change without notice
„Door open“ limit switch
47
27
26
25
„Door closed“ limit switch(cam) Switches off
the hinge-side safety sensor (e.g.IRS)
OFF (GND)
Programme switch
Exit only
Permanent open
Automatic
„Door closed“ limit switch (switches off the
safety sensor on the opposite hinge-side
jumper if not used.)
Electro-mechanical lock:
C
NO Floating contact (change over contact),
NC fixed pulse duration of 1 sec.1 sec.
DORMA GmbH + Co.KG
28
30
61
62
Sicherheitsleiste Bandgegenseite Standflügel
Solenoid valve
X7
12
45
11
13
46
Sensoric output test GF
Sensoric output test SF
X15
X6
16
17
18
19
20
21
Stabelized power supply for smoke detector
(max. 100mA) - not switched off by drive unit
disabling contact at terminal 5/6 limit switch
cut off input
R26
Hold open time 0 - 30 sec.
S1
Mode selector:
A Single-leaf mode
B Double-leaf mode
C Motor lock mode
S2
DIP Schalter Grundeinstellung alle “OFF”
OFF
ON
1 Test high active
test low active
2 Inactive test GF BS Active test GF BS
2 Inactive test GF BGS Active test GF BGS
4 Inactive test SF BS
Active test SF BS
5 Inactive test SF BGS Active test SF BGS
OFF ON
Postfach 40 09 D-58247 Ennepetal • Breckerfelder Straße 42-48 D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
•
www.dorma.com
Ader-Ident-Farbcode
D
WH
BN
GN
YE
GY
PK
BU
RD
BK
VT
GYPK
Weiß
Braun
Grün
Gelb
Grau
Rosa
Blau
Rot
Schwarz
Violett
Grau-rosa
GB
white
brown
green
yellow
grey
pink
blue
red
black
violet
grey-pink
F
blanc
marron
vert
jaune
gris
rose
bleu
rouge
noir
violet
gris-rose
I
bianco
marrone
verde
giallo
grigio
rosa
blu
rosso
nera
viola
grigio-rosa
NL
wit
bruin
groen
geel
grijs
roze
blauw
rood
zwart
paars
grijs-roze
S
vit
brun
grön
gul
grå
rosa
blå
röd
svart
lila
grå-rosa
E
blanco
marrón
verde
amarillo
gris
rosa
azul
rojo
negro
violeta
gris-rosa
Änderungen vorbehalten
Subject to change without notice
WN 055736 45532
12/06
DORMA
42
DORMA GmbH + Co.KG
Automatic Division
Postfach 40 09 D-58247 Ennepetal • Breckerfelder Straße 42-48 D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
•
www.dorma.com
31
29
WN 057029 45532
01 02/07
DORMA
ED 200-D Kabelplan
ED
ED
ED
ED
ED
ED
ED
200
200
200
200
200
200
200
an einflügeliger Tür
fixing to single double door
sur portes à un vantail
con porte a un battente
aan een enkele deur
enkelflyglig dörr.
en puerta de simple hoja
8
7
10
6
9
4
3
5
2 x ED 200 ohne Kommunikation
an zweiflügeliger Tür
2 x ED 200 without of communication
fixing to double door
2 x ED 200 sans communication
sur portes à 2 vantaux
2 x ED 200 senza comunicazione
con porte a due battenti
2 x ed 200 zonder kommunikatie
aan tweevleugelige deuren
2 x ED 200utan ihopkoppling
på dubbelflygliga dörrar
2 x ED 200 sin comunicación
con puertas de doble oja
PE
L1 N
2
1
8 7
10
10
PE
L1
N
1
6 6
2
9
3
5
2
5
4
2 kommunizierende ED 200
an zweiflügeliger Tür
2 ED 200 with communication
fixing to double door
2 ED 200 communicants
sur portes a 2 vantaux
2 ED 200 con comunicazione
con porte a due battenti
2 ED200 met Verbinding
aan tweevleugelige deuren
2 ihopkopplade ED 200
på dubbelflygliga dörrar.
2 ED 200 con comunicación
con puertas de doble oja
4
3
9
PE
L1 N
1
8 7
10
10
6 6
5
2
3
4
9
PE
L1 N
1
30
37
ED 200-D Kabelplan
WN 057029 45532
02 02/07
DORMA
1
2
3
D
GB
F
NL
Komponenten
components
Composants
bestanddelen
Sicherung
fuse
fusible
zekering
Schuko Steckverbindung
Schuko patch cord
raccord de courant
Schuko aansluiting aan net
Externer PGS
external programmme switch
commutateur de programme
extern-Programmaschakelaar
exterieur
4
5
6
7
8
9
10
1
2
3
Taster innen
pushbutton inside
commutateur intérieur
buitenschakelaar
Taster außen
pushbutton outside
commutateur extérieur
binnenschakelaar
Verriegelung
Interlock
verrouillage
grendeling
Radar innen
radar inside
radar intérieur
radar binnen
Radar außen
radar outside
radar extérieur
radar buiten
Schlüsseltaster
code key
commutateur à clef
sleutelschakelaar
ED 200
ED 200
ED 200
ED 200
I
S
E
componenti
komponent
componentes
fusibile
säkring
fusible
Schuko cavo di zona
nätanslutning
prise de courant
esterni selettore programma
yttre PGS
programador n posiciones
pulsante interno
udvendig impuls
botón interior
pulsante externo
yttre
botón exterior
serratura
lås
vlogeo elctromicanico
externo
4
5
6
7
8
9
10
3
radar insida
interior del radar
radar yttre
exterior del radar
tasto di codicer
nyckel kontakt
clave de código
ED 200
ED 200
ED 200
3 x 1,5
Änderungen vorbehalten
1
Radar interno
Radar externo
DORMA GmbH + Co.KG
38
Postfach 40 09 D-58247 Ennepetal • Breckerfelder Straße 42-48 D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
•
www.dorma.com
31
F
ED 200-D
WN 057027 45532
01 01/07
DORMA
230V/50Hz
230V/50Hz
L1 N PE
L1 N PE
T2A
24V
12V
0V
F1
24V
12V
0V
230V/50Hz
GY
GY L1
N
BU
33
32
31 X2
37
X3
36 39
X1
38 44
X4
43
42
41
40
6mF
W WH
V RD
U BK
M
18K
X1
59
60
F2
37
36 39
58
57
56
X11
X2
R26
S1
X14
X8
X1
X7
BN
GN
24
24
24
24
24
24
24
X3
38 44
X4
43
42
41
40
X7
R4
DC
DC
DC
CC
DC
DC
c.c.
W
V
U
25262714 15 7 8 11 12 13
21
20
19
18
17
16
18K
WH
stromlos öffnend
Fail save
Ouverture sans courant
Chiusura in mancanza di corrente
spanningsloos ontgrendeld
Strömlöst öppet
Desbloqueo sin corriente
X13
X6
F2 F3
X9
V
V
V
V
V
V
V
X5
35 34 6 5 2 2 4 4 1 1
36 39
A
X8
21
20
19
18
17
16
X5
37
M
6162 55 54 14 15 53 52 51 50 7 8 49 48 25 26 27 47 46 13 11 45 12
Ruhestromverriegelung
Active locking system
Verrouillage par rupture de courant
Bloccaggio a circuito aperto
Ruststroomvergrendeling
Elslutbleck (aktiv)
Electrocerradura (activa)
35 34 6 5 2 4 1
6mF
W WH
V RD
U BK
X6
B
BN
WH
GN
33
32
31 X2
44
38 43
X4
42
41
40
S2
X9
X15
N
B
A
A B C
25 26 27 14 15 7 8 11 12 13
X3
F3
X10
21
20
19
18
17
16
X7
R4
GY L1
X5
31 32 33
X13
X6
F2 F3
X9
GY
35 34 6 5 2 2 4 4 1 1
X5
A
X8
F1
230V/50Hz
BU GN YE
35 34 6 5 2 4 1
YE
GN
T2A
31 32 33
X1
59
60
F2
58
57
56
X11
37
X2
F3
R26
S1
A B C
X15
X9
B
44
38 43
X4
42
41
40
S2
X8
W
V
U
X6
B
A
X10
X14
X3
36 39
X7
21
20
19
18
17
16
6162 55 54 14 15 53 52 51 50 7 8 49 48 25 26 27 47 46 13 11 45 12
1a
32
32
33
WN 057027 45532
02 01/07
DORMA
F
ED 200-D
Arbeitsstromverriegelung
Passive locking system
Verrouillage par émission de courant
Bloccaggio a circuito chiuso
Arbeidsstroomvergrendeling
Elslutbleck (passiv)
Electrocerradura (passiva)
24
24
24
24
24
24
24
X3
36 39
X1
38 44
X4
43
42
41
40
31 32 33
X1
59
60
W
V
U
18K
37
X2
X3
36 39
F2
58
57
56
F3
A B C
25 26 27 14 15 7 8 11 12 13
X8
W
V
U
X6
21
20
19
18
17
16
S2
X9
X15
44
38 43
X4
42
41
40
B
A
S1
X14
B
R26
X11
X10
21
20
19
18
17
16
X7
R4
X13
X6
F2 F3
X9
X5
X5
37
A
X8
stromlos schließend
Fail secure
Fermeture sans courant
Apertura in mancanza di corrente
spanningsloos vergrendeld
Strömlöst stängt
Bloqueo sin corriente
DC
DC
DC
CC
DC
DC
c.c.
35 34 6 5 2 2 4 4 1 1
35 34 6 5 2 4 1
33
32
31 X2
V
V
V
V
V
V
V
X7
6162 55 54 14 15 53 52 51 50 7 8 49 48 25 26 27 47 46 13 11 45 12
1b
Arbeitsstromverriegelung
Passive locking system
Verrouillage par émission de courant
Bloccaggio a circuito aperto
Arbeidsstroomvergrendeling
Elslutbleck (passiv)
Electrocerradura (pasiva)
24
24
24
24
24
24
24
X3
36 39
38 44
X4
43
42
41
40
F2 F3
X7
X9
R4
X13
W
V
U
X6
A
X8
stromlos schließend
Fail secure
Fermeture sans courant
Chiusura in mancanza di corrente
spanningsloos vergrendeld
Strömlöst stängt
Bloqueo sin corriente
X5
X5
37
X1
AC
AC
AC
CA
AC
AC
c.a.
35 34 6 5 2 2 4 4 1 1
35 34 6 5 2 4 1
33
32
31 X2
V
V
V
V
V
V
V
25 26 27 14 15 7 8 11 12 13
21
20
19
18
17
16
18K
31 32 33
X1
59
60
F2
58
57
56
X11
37
X2
F3
S1
A B C
X14
X15
B
R26
X9
44
38 43
X4
42
41
40
S2
X8
W
V
U
X6
B
A
X10
X3
36 39
X7
21
20
19
18
17
16
6162 55 54 14 15 53 52 51 50 7 8 49 48 25 26 27 47 46 13 11 45 12
1c
34
33
33
WN 057027 45532
03 01/07
DORMA
F
ED 200-D
Anschluß 4SAVE -Sensorleiste
ED 200-D
1)
S2 Grundeinstellung: 1 ist ON - 2 bis 5 sind OFF
1 OFF = Test high aktiv
ON = Test low aktiv
2 OFF = inaktiv Test GF BS ON = aktiv Test GF BS(14/15)
3 OFF = inaktiv Test GF BGS ON = aktiv Test GF BGS(52/53)
4 OFF = inaktiv Test SF BS ON = aktiv Test SF BS(54/55)
5 OFF = inaktiv Test SF BGS ON = aktiv Test SF BGS(61/62)
OFF ON
BEA 4SAFE
Gangflügel
4SAFE Slave 3
GN BN
GN BN
X5
35 34 6 5 2 2 4 4 1 1
RD
RD
18K
31 32 33
X1
59
X2
F2
60
58
57
56
F3
R26
X11
S1
A B C
X14
X15
X9
B
S2
1
2
3
4
5
X8
W
V
U
4SAFE Slave 1
X6
B
A
X10
4SAFE Slave 2
X7
61 62 55 54 14 15 53 52 51 50 7 8 49 48 25 26 27 47 46 13 11 45 12
PK GY YE WH YE WH GY PK
BU BU
21
20
19
18
17
16
4SAFE Master
BU
RD
YE
BN
GN
WH
PK
GY
Bandseite
X13
44
37 36 39
38 43
X3
X4
42
41
40
Bandgegenseite
Sensoren positionieren
Initialisierung durchführen
Grauwert einstellen
Sensorik BS = Relais 1 / Sensorik BGS = Relais 2 zuweisen
GND
+24V
Standflügel
4SAFE Slave 3
4SAFE Slave 2
Bandgegenseite
2)
3)
4)
5)
4SAFE Master
2
34
34
BU
RD
YE
BN
GN
WH
PK
GY
GND
+24V
Bandseite
4SAFE Slave 1
WN 057027 45532
04 01/07
DORMA
F
ED 200-D
Gangflügel
Anschluß IRS-3 -Sensorleiste
ED 200-D
1)
S2 Grundeinstellung: 1 ist ON - 2 bis 5 sind OFF
1 OFF = Test high aktiv
ON = Test low aktiv
2 OFF = inaktiv Test GF BS ON = aktiv Test GF BS(14/15)
3 OFF = inaktiv Test GF BGS ON = aktiv Test GF BGS(52/53)
4 OFF = inaktiv Test SF BS ON = aktiv Test SF BS(54/55)
5 OFF = inaktiv Test SF BGS ON = aktiv Test SF BGS(61/62)
OFF ON
Bei Absicherung der Tür nach DIN 18650:
2)
3)
4)
5)
Sensoren anschließen
Dipschalter 1 an ED 200-D in Stellung ON (=Test low aktiv) stellen
Dipschalter 2 - 5 an ED 200-D entsprechend montierter Sensorik in Stellung ON schalten
Testfunktion an IRS-3 sensorik aktivieren.
Gangflügel Bandgegenseite
ED 200-D
3534
35
346
X5
5 2 2 4 4 1 1
44
37 36 39
38 43
X3
X4
42
41
40
X13 31 32 33
59
60
18K
X1
X2
F2
58
57
56
F3
R26
X11
A B C
X15
21
20
19
18
17
16
S2
S1
X14
X6
B
B
A
X10
1
2
3
4
5
X9
X8
53 5251 50 7
W
V
U
X7
8 49 48 25 26 27 47 46 13 11 45 12
61 62 55 54 14 15
3a
GND
1
2
+24V
C
3
NC
4
5
NO
6 Test input
IRS-3
GND
1
2
+24V
C
3
NC
4
5
NO
6 Test input
IRS-3
Gangflügel Bandseite
ED 200-D
3534
35
346
X5
5 2 2 4 4 1 1
X13 31 32 33
59
60
18K
X1
F2
58
57
56
37
X2
F3
R26
X11
S1
A B C
X15
X9
3b
B
S2
1
2
3
4
5
14 1553 52 51 50 7
61 62 55 54
44
38 43
X4
42
41
40
X8
W
V
U
X6
B
A
X10
X14
X3
36 39
X7
21
20
19
18
17
16
8 49 48 25 26 27 47 46 13 11 45 12
35
WN 057027 45532
05 01/07
DORMA
F
ED 200-D
Standflügel
Anschluß IRS-3 -Sensorleiste
ED 200-D
1)
S2 Grundeinstellung: 1 ist ON - 2 bis 5 sind OFF
1 OFF = Test high aktiv
ON = Test low aktiv
2 OFF = inaktiv Test GF BS ON = aktiv Test GF BS(14/15)
3 OFF = inaktiv Test GF BGS ON = aktiv Test GF BGS(52/53)
4 OFF = inaktiv Test SF BS ON = aktiv Test SF BS(54/55)
5 OFF = inaktiv Test SF BGS ON = aktiv Test SF BGS(61/62)
OFF ON
Bei Absicherung der Tür nach DIN 18650:
2)
3)
4)
5)
Sensoren anschließen
Dipschalter 1 an ED 200-D in Stellung ON (=Test low aktiv) stellen
Dipschalter 2 - 5 an ED 200-D entsprechend montierter Sensorik in Stellung ON schalten
Testfunktion an IRS-3 sensorik aktivieren.
Standflügel Bandgegenseite
ED 200-D
3534
35
346
X5
5 2 2 4 4 1 1
44
37 36 39
38 43
X3
X4
42
41
40
X13 31 32 33
X1
59
60
18K
F2
58
57
56
X2
F3
R26
X11
A B C
X15
21
20
19
18
17
16
S2
S1
X14
X6
B
B
A
X10
1
2
3
4
5
X9
X8
6162
61
6255 54 14 15 53 52 51 50 7
W
V
U
X7
8 49 48 25 26 27 47 46 13 11 45 12
3c
GND
1
2
+24V
C
3
NC
4
5
NO
6 Test input
IRS-3
GND
1
2
+24V
C
3
NC
4
5
NO
6 Test input
IRS-3
Standflügel Bandseite
ED 200-D
3534
35
346
X5
5 2 2 4 4 1 1
X13 31 32 33
X1
59
Änderungen vorbehalten
Subject to change without notice
18K
60
F2
58
57
56
F3
X2
S1
X15
X9
3d
B
S2
1
2
3
4
5
5554
55
5414 15 53 52 51 50 7
61 62
44
38 43
X4
42
41
40
X8
W
V
U
X6
B
A
A B C
X14
X3
36 39
R26
X11
X10
DORMA GmbH + Co.KG
36
37
X7
21
20
19
18
17
16
8 49 48 25 26 27 47 46 13 11 45 12
Postfach 40 09 D-58247 Ennepetal • Breckerfelder Straße 42-48 D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
•
www.dorma.de
ED 200-D
WN 057030 45532
01 12/06
DORMA
230V/50Hz
PE
N
L1
L1
N
PE
L1 N PE
24V
12V
0V
L1 N PE
230V/50Hz
RM ED
F1
T2A
GY
GY L1
F1
T2A
GY
BU GN YE
GY L1
N
X5
31 32 33 35 34 6 5 2 2 4 4 1 1
X5
6mF
6mF
X2
X4
W WH
V RD
U BK
M
18k W
X3
X2
X6
A
F2 F3
X7
X8
230V/50Hz
+ 24V RM
GND
N
3534 6 5 2 2 4 4 1 1
YE 33
GN 32
BU 31
24V
12V
0V
R4
21
20
19
18
17
16
59
60
58
57
56
X10
X1
X13
X4
W WH
V RD
U BK
F2
F3
X11
B
R26
A
S1
X14
X3
X2
X9
21
20
19
18
17
16
B
S2
X8
X7
25 26 27 14 15 7 8 11 12 13
61 62 55 54 14 15 53 52 51 50 7 8 49 48 25 26 27 47 46
45
BN GN
WH
GB
D
Bei der Montage von ED 200 an 2-flügligen
Türen sind folgende Punkte zu beachten:
l
l
l
Antrieb mit Steuerung A am Standflügel, Antrieb mit
Steuerung B am Gangflügel.
In Steuerung A Brücke zwischen Klemme 5/6 und 14/15
entfernen.
In Steuerung B Schalter S1 in Stellung B stellen.
When installing the ED 200 at double doors,
ensure compliance with the following instructions:
l
l
l
l
l
l
M
X6
Alle Komponenten wie Radarmelder, Sensorleisten,
Rückmelder usw. an Steuerung B anschließen.
E-Öffner für den Standflügel an Steuerung A anschließen.
Beim Standflügelantrieb darf die weiße Nockenscheibe in
"Tür zu" Position nicht den Endschalter betätigen.
(sonst keine Anlaufverzögerung)
l
l
l
Operator drive unit with control module A to be fixed to the
inactive leaf, drive unit with control module B to be fixed
to the active leaf.
In control module A, remove the jumpers at terminals 5/6
and 14/15.
In control module B, set switch S1 to position B.
Connect all components such as radar detectors, sensors,
checkback signalling units, repeaters etc. to control
module B
Connect the inactive leaf electric keep to control module A
Ensure that the white cam disc in the inactive leaf
operator does not actuate the limit switch in the
"Door Closed" position
(as otherwise this will disable the starting delay function).
37
39
F
ED 200-D
WN 057026 45532
01 06/06
DORMA
D
35 34 6 5 2 4 1
33
32
31
L1
36 39
37
X1 X3
N
38 X5
44
43
42
X4
X2
X6
A
21
20
19
18
17
16
F2 F3
X7
X8
N
41 V
40 U
R4
25 26 27 14 15 7 8 11 12 13
L1
31 32 33 35 34 6 5 2 2 4 4 1 1 37
X13
59
60
18K
X3
X2
X1
36 39
N
38 X5
44
43
42 N
41 V
40 U
X4
F2
B
F3
58
57
56
R26
X6
X11
A
B
X10
S1
A B C
S2
X14
X15
X9
X8
X7
21
20
19
18
17
16
6162 55 54 14 15 53 52 51 50 7 8 49 48 25 26 27 47 46 13 11 45 12
Bei der Verwendung des ED 200 in Feststellanlagen ist bei der
regelmäßigen Wartung auch die folgende Prüfung durchzuführen:
1. Antriebsabdeckung abschrauben.
2. Rauchmelder auslösen.
3. Multimeter auf Spannungsmessung V AC einstellen.
4. Spannung zwischen den Anschlußklemmen L1 (39) und U (40) messen.
Wird eine Spannung von 230 V AC angezeigt, so ist die Steuerung auszutauschen.
5. Spannung zwischen den Anschlußklemmen N (38) und V (41) messen.
Änderungen vorbehalten
Wird eine Spannung von 230 V AC angezeigt, so ist die Steuerung auszutauschen.
6.
Wird unter Punkt 4 und 5 keine Spannung angezeigt, so arbeitet die Steuerung
einwandfrei und die Antriebsabdeckung kann wieder aufgeschraubt werden.
DORMA GmbH + Co.KG
38
Postfach 40 09 D-58247 Ennepetal • Breckerfelder Straße 42-48 D-58256 Ennepetal
Tel. +49 (0) 23 33 / 793-0
•
Fax +49 (0) 23 33 / 79 34 95
•
www.dorma.com
40