Application Note E-Mail and text message configuration for

Transcrição

Application Note E-Mail and text message configuration for
Application Note
E-Mail and text message configuration for
PLATINUM WebMaster
PLATINUM® Service Zentrale
Diehl AKO Stiftung & Co. KG
Pfannerstraße 75
88239 Wangen im Allgäu, Deutschland
Tel: +49 7522 73-777
Fax: +49 7522 73-737
[email protected]
Author
Service
Status
Valid
Category
Monitoring
Version
1.0
Date
2012-06-28
Summary
For your PLATINUM WebMaster (PWM) to be able to send e-mails or text messages, the following
prerequisites must be met:
1. The PWM is able to establish an internet connection.
2. The PWM has an e-mail account to send e-mails.
3. The respective message recipients must be set in the PWM.
4. The events to be sent must be configured for the respective message recipients.
5. The message recipient’s mobile phone most be configured for receiving e-mail.
Establishing the internet dial-up
Hardware
The “Internet dial-up allowed” switch on the WebMaster must be set to ON.
Modem
Call-up via navigation:
Configuration -> Modem -> Edit (login and password both „admin“)
Fig. 1: Screen Modem configuration
PLATINUM® Service Zentrale
Diehl AKO Stiftung & Co. KG
Pfannerstraße 75
88239 Wangen im Allgäu, Deutschland
Tel: +49 7522 73-777
Fax: +49 7522 73-737
[email protected]
The following data must be entered here:
Dial-up number:
Dial-up number of your internet provider (e.g. MSN)
When dialing up at a private branch exchange, it is possible that “0w” (dialing prefix
with pause) must be entered
Login name:
User name with your internet provider’
Password:
Your password with your internet provider
Add. modem
ATX3
When dialing up at a private branch exchange, the free-line signal must be ignored.
instructions
Network
Call-up via navigation:
Configuration -> Network -> Edit
192.76.144.66
Fig. 2: Screen Network configuration
PLATINUM® Service Zentrale
Diehl AKO Stiftung & Co. KG
Pfannerstraße 75
88239 Wangen im Allgäu, Deutschland
Tel: +49 7522 73-777
Fax: +49 7522 73-737
[email protected]
The following data must be entered here:
DNS server:
Name server that converts a www address into a usable IP
192.76.144.66
Standard gateway
must remain empty
E-mail service
Call-up via navigation:
Configuration -> E-mail service -> Edit (login and password both „admin“)
Fig. 3: Screen E-mail service configuration
The following data must be entered here:
SMTP server:
Outgoing mail server of your e-mail provider
Login name:
User name for your e-mail account
Password:
Your password for your e-mail account
Sender address:
E-mail address of the e-mail account
SMTP authentification:
switched on
switched on means: the WebMaster authenticates itself on the e-mail server; this is
not necessary if the internet dial-up is done e.g. via T-Online and the WebMaster
has already authenticated itself there; it is also possible that an authentication is
PLATINUM® Service Zentrale
Diehl AKO Stiftung & Co. KG
Pfannerstraße 75
88239 Wangen im Allgäu, Deutschland
Tel: +49 7522 73-777
Fax: +49 7522 73-737
[email protected]
not necessary if an internal mail server is used
Note:
The e-mail provider selected must support the SMTP authentication. At the moment, possible
providers are e.g. GMX, freenet and vrweb.
Other providers use the authentication “POP before SMTP” (e.g. Web.de, aol.com)
Message recipient
Call-up via navigation:
Configuration -> Message recipient -> Edit (login and password both „admin“)
Fig. 4: Screen Message recipient configuration
PLATINUM® Service Zentrale
Diehl AKO Stiftung & Co. KG
Pfannerstraße 75
88239 Wangen im Allgäu, Deutschland
Tel: +49 7522 73-777
Fax: +49 7522 73-737
[email protected]
The following data must be entered here:
Type:
E-mail
Name:
Name of the recipient
E-mail address:
E-mail address of the recipient:
For text message on D2 e.g.: <mobile phone number>@d2-message.de, see also
Table 1
Status:
active
Message selection
Call-up via navigation:
Monitoring -> <respective event type> ->
(illustrated using the example of Inverter failure)
Fig. 5: Screen Monitoring/inverter failure configuration
The following data must be entered here:
Message:
active
Interval:
how often will the e-mail/text message be sent
Recipient:
all entries set up according to chapter „Message
recipient“ can
be selected here
We recommend selecting only the message types “Inverter failure” and “No daily yield” so
that you aren’t flooded by unnecessary text messages.
PLATINUM® Service Zentrale
Diehl AKO Stiftung & Co. KG
Pfannerstraße 75
88239 Wangen im Allgäu, Deutschland
Tel: +49 7522 73-777
Fax: +49 7522 73-737
[email protected]
Mobile phone set-up
To be able to receive e-mails as text messages, the mobile phone must be configured for receiving e-mail. A
fee is charged for receiving e-mail.
The exact procedure may vary for the different network providers.
The receiving mobile phone’s an e-mail address will be in the format <telephone number>@<mail server>
(see Table 1)
The following table lists the procedures for several network providers (source: www.oliverbrosch.de/tarife/SMS.html).
Provider
Activating e-mail
as text message
T-Mobile
Send text
message “OPEN”
to 8000
Vodafone D2
Send text
message “OPEN”
to 3400
Deactivating email as text
message
Mail server
Send text
message
“CLOSE” to 8000
t-d1-sms.de
Send text
message
“CLOSE” to 3400
d2-message.de
or
vodafone-sms.de
Table 1: E-mail as text message with several network providers
PLATINUM® Service Zentrale
Diehl AKO Stiftung & Co. KG
Pfannerstraße 75
88239 Wangen im Allgäu, Deutschland
Tel: +49 7522 73-777
Fax: +49 7522 73-737
[email protected]
E-Plus
Send text
message
“START” to
7676245
Send text
message “STOP”
to 7676245
smsmail.eplus.de
O2
Send any text
message to 6245
Send text
message “STOP”
to 6245
0179.net