Application Note E-Mail and text message configuration for
Transcrição
Application Note E-Mail and text message configuration for
Application Note E-Mail and text message configuration for PLATINUM WebMaster PLATINUM® Service Zentrale Diehl AKO Stiftung & Co. KG Pfannerstraße 75 88239 Wangen im Allgäu, Deutschland Tel: +49 7522 73-777 Fax: +49 7522 73-737 [email protected] Author Service Status Valid Category Monitoring Version 1.0 Date 2012-06-28 Summary For your PLATINUM WebMaster (PWM) to be able to send e-mails or text messages, the following prerequisites must be met: 1. The PWM is able to establish an internet connection. 2. The PWM has an e-mail account to send e-mails. 3. The respective message recipients must be set in the PWM. 4. The events to be sent must be configured for the respective message recipients. 5. The message recipient’s mobile phone most be configured for receiving e-mail. Establishing the internet dial-up Hardware The “Internet dial-up allowed” switch on the WebMaster must be set to ON. Modem Call-up via navigation: Configuration -> Modem -> Edit (login and password both „admin“) Fig. 1: Screen Modem configuration PLATINUM® Service Zentrale Diehl AKO Stiftung & Co. KG Pfannerstraße 75 88239 Wangen im Allgäu, Deutschland Tel: +49 7522 73-777 Fax: +49 7522 73-737 [email protected] The following data must be entered here: Dial-up number: Dial-up number of your internet provider (e.g. MSN) When dialing up at a private branch exchange, it is possible that “0w” (dialing prefix with pause) must be entered Login name: User name with your internet provider’ Password: Your password with your internet provider Add. modem ATX3 When dialing up at a private branch exchange, the free-line signal must be ignored. instructions Network Call-up via navigation: Configuration -> Network -> Edit 192.76.144.66 Fig. 2: Screen Network configuration PLATINUM® Service Zentrale Diehl AKO Stiftung & Co. KG Pfannerstraße 75 88239 Wangen im Allgäu, Deutschland Tel: +49 7522 73-777 Fax: +49 7522 73-737 [email protected] The following data must be entered here: DNS server: Name server that converts a www address into a usable IP 192.76.144.66 Standard gateway must remain empty E-mail service Call-up via navigation: Configuration -> E-mail service -> Edit (login and password both „admin“) Fig. 3: Screen E-mail service configuration The following data must be entered here: SMTP server: Outgoing mail server of your e-mail provider Login name: User name for your e-mail account Password: Your password for your e-mail account Sender address: E-mail address of the e-mail account SMTP authentification: switched on switched on means: the WebMaster authenticates itself on the e-mail server; this is not necessary if the internet dial-up is done e.g. via T-Online and the WebMaster has already authenticated itself there; it is also possible that an authentication is PLATINUM® Service Zentrale Diehl AKO Stiftung & Co. KG Pfannerstraße 75 88239 Wangen im Allgäu, Deutschland Tel: +49 7522 73-777 Fax: +49 7522 73-737 [email protected] not necessary if an internal mail server is used Note: The e-mail provider selected must support the SMTP authentication. At the moment, possible providers are e.g. GMX, freenet and vrweb. Other providers use the authentication “POP before SMTP” (e.g. Web.de, aol.com) Message recipient Call-up via navigation: Configuration -> Message recipient -> Edit (login and password both „admin“) Fig. 4: Screen Message recipient configuration PLATINUM® Service Zentrale Diehl AKO Stiftung & Co. KG Pfannerstraße 75 88239 Wangen im Allgäu, Deutschland Tel: +49 7522 73-777 Fax: +49 7522 73-737 [email protected] The following data must be entered here: Type: E-mail Name: Name of the recipient E-mail address: E-mail address of the recipient: For text message on D2 e.g.: <mobile phone number>@d2-message.de, see also Table 1 Status: active Message selection Call-up via navigation: Monitoring -> <respective event type> -> (illustrated using the example of Inverter failure) Fig. 5: Screen Monitoring/inverter failure configuration The following data must be entered here: Message: active Interval: how often will the e-mail/text message be sent Recipient: all entries set up according to chapter „Message recipient“ can be selected here We recommend selecting only the message types “Inverter failure” and “No daily yield” so that you aren’t flooded by unnecessary text messages. PLATINUM® Service Zentrale Diehl AKO Stiftung & Co. KG Pfannerstraße 75 88239 Wangen im Allgäu, Deutschland Tel: +49 7522 73-777 Fax: +49 7522 73-737 [email protected] Mobile phone set-up To be able to receive e-mails as text messages, the mobile phone must be configured for receiving e-mail. A fee is charged for receiving e-mail. The exact procedure may vary for the different network providers. The receiving mobile phone’s an e-mail address will be in the format <telephone number>@<mail server> (see Table 1) The following table lists the procedures for several network providers (source: www.oliverbrosch.de/tarife/SMS.html). Provider Activating e-mail as text message T-Mobile Send text message “OPEN” to 8000 Vodafone D2 Send text message “OPEN” to 3400 Deactivating email as text message Mail server Send text message “CLOSE” to 8000 t-d1-sms.de Send text message “CLOSE” to 3400 d2-message.de or vodafone-sms.de Table 1: E-mail as text message with several network providers PLATINUM® Service Zentrale Diehl AKO Stiftung & Co. KG Pfannerstraße 75 88239 Wangen im Allgäu, Deutschland Tel: +49 7522 73-777 Fax: +49 7522 73-737 [email protected] E-Plus Send text message “START” to 7676245 Send text message “STOP” to 7676245 smsmail.eplus.de O2 Send any text message to 6245 Send text message “STOP” to 6245 0179.net