Weinmann Update Tool
Transcrição
Weinmann Update Tool
Weinmann Update Tool Update-Anweisung / Update Instructions / Notice de mise à jour Deutsch 3 English 14 Français 25 Inhaltsverzeichnis Inhaltsverzeichnis Deutsch 1 Einführung 4 1.1 Produktbeschreibung.......................................................................4 1.2 Anwenderqualifikation ....................................................................4 1.3 Systemvoraussetzungen...................................................................4 2 3 4 Sicherheit Installation Bedienung 5 5 9 Therapiegerät mit dem PC verbinden ...............................................9 4.2 Firmware des Therapiegerätes aktualisieren ...................................10 4.3 Schnittstelle am PC auswählen ......................................................12 4.4 Gerät identifizieren........................................................................12 4.5 Sprache ändern .............................................................................13 WM 67540b 02/2012 4.1 Weinmann Update Tool DE 3 1 Einführung 1 Einführung 1.1 Produktbeschreibung Mit dem Weinmann Update Tool können Sie die Firmware von Weinmann-Therapiegeräten aktualisieren. Das Weinmann Update Tool besteht aus folgenden Komponenten: • Konverterkabel USB-RS485 (WM 93318) • Verbindungsleitung Vollduplex (WM 93308) (VentilogicLS/Plus) • Anschlussleitung (WM 93319) (Ventimotion 2) • CD mit Weinmann Update Tool Die aktuelle Firmware für das Therapiegerät finden Sie unter www.weinmann.de im Login-Bereich zum Download. Bei Fragen oder Rückmeldungen wenden Sie sich an den Technischen Service: Telefon: +49-(0) 40- 5 47 02-101 Email: [email protected] 1.2 Anwenderqualifikation Diese Update-Anweisung richtet sich ausschließlich an folgende Personen: • Von Weinmann autorisierte Fachhändler • Produktspezialisten und Servicemitarbeiter von Weinmann Um das Weinmann Update Tool einzusetzen, benötigen Sie einen PC mit folgenden Voraussetzungen: 4 DE • Windows XP (Service Pack 3) • USB-Schnittstelle Weinmann Update Tool WM 67540b 02/2012 1.3 Systemvoraussetzungen 2 Sicherheit • 2 Administatorrechte Sicherheit Verletzungsgefahr durch Aktualisieren des Therapiegerätes während der Therapie! Das Aktualisieren des Therapiegerätes während der Therapie kann den Patienten gefährden. ⇒ Weinmann Update Tool niemals benutzen, wenn ein Patient an das Therapiegerät angeschlossen ist. 3 Installation 1. CD in den PC einlegen. WM 67540b 02/2012 2. Die Datei WeinmannUpdateSetup.exe ausführen. Der Installationsassistent wird gestartet. 3. Schaltfläche Weiter anklicken. Weinmann Update Tool DE 5 3 Installation 4. Auswählen, ob ein Icon für das Programm im Startmenü und auf dem Desktop erscheinen soll. 6. Wenn notwendig: Zielverzeichnis auswählen, in dem das Weinmann Update Tool gespeichert werden soll. 6 DE Weinmann Update Tool WM 67540b 02/2012 5. Schaltfläche Weiter anklicken. 3 Installation 7. Schaltfläche Installieren anklicken. Es öffnet sich ein Dialog zur Installation des Treibers des Konverterkabels USB-RS485. 8. Schaltfläche Install anklicken, um den Treiber zu installieren. Der Installationsassistent sucht die passenden Dateien. Je nach PC kann dieser Vorgang etwas dauern. WM 67540b 02/2012 9. Wenn die Meldung Softwareinstallation erscheint: Schaltfläche Installation fortsetzen anklicken. Diese Meldung erscheint in Ausnahmefällen. Die Ursache dafür liegt in Ihrem Betriebssystem. Sie können die Installation bedenkenlos fortsetzen. 10. Abschluss der Treiberinstallation mit OK bestätigen. Es öffnet sich der Installationsassistent von JavaTM. Weinmann Update Tool DE 7 3 Installation 11. Wenn JavaTM noch nicht auf Ihrem PC installiert ist: Schaltfläche Installieren anklicken. JavaTM wird installiert. WM 67540b 02/2012 12. Nach erfolgreicher Installation: Schaltfläche Schließen anklicken. Der Installationsassistent führt die Installation fort. 8 DE Weinmann Update Tool 4 Bedienung 13. Schaltfläche Beenden anklicken, um die Installation abzuschließen. Ergebnis 4 Die Installation ist abgeschlossen. Das Weinmann Update Tool kann verwendet werden. Bedienung 4.1 Therapiegerät mit dem PC verbinden 1 2 1. Therapiegerät mit der Verbindungsleitung Vollduplex (WM 93308 / VentilogicLS/Plus) / Anschlussleitung (WM 93319 / Ventimotion 2) 1 verbinden. 2. Verbindungsleitung Vollduplex (WM 93308 / VentilogicLS/Plus) / Anschlussleitung (WM 93319 / Ventimotion 2) 1 mit dem Konverterkabel USB-RS485 2 verbinden. 3. Konverterkabel USB-RS485 2 mit einem freien USB-Anschluss am PC verbinden. WM 67540b 02/2012 4. Therapiegerät an eine Netzsteckdose anschließen. Das Therapiegerät schaltet in den Standby. Das WeinmannLogo erscheint im Display. Ergebnis Therapiegerät und PC sind verbunden. Weinmann Update Tool DE 9 4 Bedienung 4.2 Firmware des Therapiegerätes aktualisieren Verletzungsgefahr durch Aktualisieren des Therapiegerätes während der Therapie! Das Aktualisieren des Therapiegerätes während der Therapie kann den Patienten gefährden. ⇒ Weinmann Update Tool niemals benutzen, wenn ein Patient an das Therapiegerät angeschlossen ist. Sachschaden durch Trennen der Verbindungen! Das Trennen der Verbindung zwischen Stromnetz, Therapiegerät und PC während der Aktualisierung kann das Therapiegerät beschädigen. ⇒ Verbindung zwischen Therapiegerät und PC nicht trennen. ⇒ Therapiegerät nicht vom Stromnetz trennen. Voraussetzung Therapiegerät ist mit dem PC verbunden (siehe „4.1 Therapiegerät mit dem PC verbinden“, Seite 9). 1. Weinmann Update Tool starten. 2. Nur bei der ersten Durchführung: Schnittstelle zum PC wählen (siehe „4.3 Schnittstelle am PC auswählen“, Seite 12). 3. Schaltfläche Datei öffnen anklicken. 4. Update-Datei auswählen. 5. Schaltfläche Update starten anklicken. In dem folgenden Dialog können Sie wählen, ob Sie die Therapieparameter und Patientendaten auf die neue Version übertragen möchten oder ob das Gerät in den Auslieferungszustand versetzt werden soll. 10 DE Weinmann Update Tool WM 67540b 02/2012 Die Update-Datei für das Therapiegerät finden Sie unter www.weinmann.de im Login-Bereich zum Download. Die Update-Datei ist immer mit dem Namen des Therapiegerätes und der jeweiligen Firmware-Version benannt. Die Update-Datei hat die Dateiendung .wmu. 4 Bedienung 6. Schaltfläche Ja oder Nein anklicken, je nachdem, ob die Sie die Therapieparameter und Patientendaten behalten möchten oder nicht. Der Update-Vorgang wird gestartet. WM 67540b 02/2012 Während der Aktualisierung werden auf dem Display des Therapiegerätes Fehlermeldungen und akustische Signale ausgegeben. Dies ist Teil der Aktualisierung und keine Fehlfunktion des Therapiegerätes. Wenn die Aktualisierung beendet ist, wird die Meldung Update erfolgreich angezeigt. 7. Am Therapiegerät prüfen, ob die aktuelle Firmware-Version angezeigt wird. Weinmann Update Tool DE 11 4 Bedienung 8. Wenn die Aktualisierung nicht abgeschlossen werden konnte, zeigt das Programm eine Fehlermeldung an. Beachten Sie in diesem Fall die Anweisungen auf dem Bildschirm. Ergebnis Die Aktualisierung ist abgeschlossen. Das Therapiegerät hat die aktuelle Firmware-Version. 4.3 Schnittstelle am PC auswählen Bei der ersten Benutzung des Weinmann Update Tools kann es notwendig sein, die Schnittstelle am PC auszuwählen. 1. Im Menü Schnittstellen die verwendete Schnittstelle anklicken. oder Wenn Sie nicht sicher sind, welche Schnittstelle Sie benutzen: Automatische Suche anklicken. Dabei beachten: Es muss ein Therapiegerät mit dem PC verbunden sein (siehe „4.1 Therapiegerät mit dem PC verbinden“, Seite 9). Ergebnis Das Programm wählt die Schnittstelle, über die das Therapiegerät mit dem PC verbunden ist. 4.4 Gerät identifizieren 1. Schaltfläche Gerät identifizieren anklicken. Ergebnis 12 DE Der Gerätetyp und die aktuelle aktuelle Version des Therapiegerätes werden angezeigt. Weinmann Update Tool WM 67540b 02/2012 Wenn Sie wissen möchten, welche Software-Version aktuell auf Ihrem Therapiegerät ist, können Sie das Gerät identifizieren. 4 Bedienung Sie brauchen das Therapiegerät nicht zu identifizieren, um ein Update durchzuführen. Das Programm erkennt den Gerätetyp und die Version während der Aktualisierung automatisch. 4.5 Sprache ändern Sie können zwischen den Sprachen Deutsch, Englisch und Französisch wählen. Bei der Installation wird die Sprache des Betriebssystems gewählt. 1. Gewünschte Sprache im Menü Sprachen auswählen. 2. Meldung mit OK bestätigen. 3. Weinmann Update Tool neu starten. Die Sprache ist geändert. WM 67540b 02/2012 Ergebnis Weinmann Update Tool DE 13 Contents Contents English 1 Introduction 15 1.1 Product description .......................................................................15 1.2 User qualification ..........................................................................15 1.3 System requirements .....................................................................15 2 3 4 Safety Installation Operation 16 16 20 Connect the therapy device to the PC ............................................20 4.2 Update the therapy device firmware ..............................................20 4.3 Choose the interface on the PC .....................................................23 4.4 Identify device...............................................................................23 4.5 Change language..........................................................................24 WM 67540b 02/2012 4.1 14 EN Weinmann Update Tool 1 Introduction 1 Introduction 1.1 Product description The Weinmann Update Tool enables you to update the firmware of Weinmann therapy devices. The Weinmann Update Tool consists of the following components: • USB-RS485 converter cable (WM 93318) • Full duplex connection lead (WM 93308) (VentilogicLS/Plus) • Connecting cable (WM 93319) (Ventimotion 2) • CD with Weinmann Update Tool The latest firmware for the therapy device can be downloaded from the login area at www.weinmann.de. If you have any questions or feedback, please contact our Technical Service team: Tel.: +49-(0) 40- 5 47 02-101 E-mail: [email protected] 1.2 User qualification These update instructions are intended solely for the following persons: • Specialist dealers authorized by Weinmann • Product specialists and Weinmann service employees WM 67540b 02/2012 1.3 System requirements To use the Weinmann Update Tool, you will need a PC with the following minimum configuration: • Windows XP (Service Pack 3) • USB port Weinmann Update Tool EN 15 2 Safety • 2 Administrator rights Safety Danger of injury as a result of updating the therapy device while therapy is in progress. Updating the therapy device during therapy can put the patient at risk. ⇒ Never use the Weinmann Update Tool if a patient is connected to the therapy device. 3 Installation 1. Insert CD into the PC. 3. Click the Next button. 16 EN Weinmann Update Tool WM 67540b 02/2012 2. Run the WeinmannUpdateSetup.exe file. The installation wizard starts. 3 Installation 4. Choose whether you want to create an icon for the program in the start menu and on the desktop. WM 67540b 02/2012 5. Click the Next button. 6. If required, select the target directory in which you want to save the Weinmann Update Tool. Weinmann Update Tool EN 17 3 Installation 7. Click the Install button. A dialog box for installing the USB-RS485 converter cable driver pops up. 8. Click the Install button to install the driver. The installation wizard searches for the relevant files. Depending on the PC, this can take some time. This message only appears in exceptional cases. This is due to your operating system. You can continue the installation without reservation. 10. Click OK to acknowledge that the driver has been installed. The JavaTM installation wizard opens. 18 EN Weinmann Update Tool WM 67540b 02/2012 9. If the message Software installation appears: Click the Continue Anyway button. 3 Installation 11. If JavaTM is not yet installed on your PC, click the Install button. JavaTM is installed. WM 67540b 02/2012 12. After it has been installed, click Close. The installation wizard continues the installation process. 13. Click the Close button to complete the installation. Result Installation is complete. The Weinmann Update Tool can be used. Weinmann Update Tool EN 19 4 Operation 4 Operation 4.1 Connect the therapy device to the PC 1 2 1. Connect the therapy device to the full duplex connection lead (WM 93308 / VentilogicLS/Plus) / connecting cable (WM 93319 / Ventimotion 2) 1. 2. Connect the full duplex connection lead (WM 93308 / VentilogicLS/Plus) / connecting cable (WM 93319 / Ventimotion 2) 1 to the USB-RS485 converter cable 2. 3. Connect the USB-RS485 converter cable 2 to a free USB port on the PC. 4. Plug the therapy device into a power outlet. The therapy device switches to standby mode. The Weinmann logo appears on the display. Result The therapy device and PC are connected. Danger of injury through updating the therapy device during therapy. Updating the therapy device during therapy can put the patient at risk. ⇒ Never use the Weinmann Update Tool when a patient is connected to the therapy device. 20 EN Weinmann Update Tool WM 67540b 02/2012 4.2 Update the therapy device firmware 4 Operation Material damage caused by disconnecting the connections. Disconnecting the power supply, therapy device and the PC during the update process can damage the therapy device. ⇒ Do not disconnect the therapy device from the PC. ⇒ Do not disconnect the therapy device from the power supply. Requirement The therapy device is connected to the PC (see "4.1 Connect the therapy device to the PC", page 20). 1. Start the Weinmann Update Tool. 2. First time only: choose the PC interface (see "4.3 Choose the interface on the PC", page 23). 3. Click the Open file button. 4. Select the update file. The update file for the therapy device can be downloaded from the login area at www.weinmann.de. The name of the update file is always the name of the therapy device plus the relevant firmware version. The update file extension is .wmu. WM 67540b 02/2012 5. Click the Start update button. In the following dialog box, you can choose to transfer the therapy parameter(s) and patient data to the new version or to reset the device to its factory settings. Weinmann Update Tool EN 21 4 Operation 6. Click the Yes or No button depending on whether you want to retain the therapy parameter(s) and patient data. The update process is started. When the device has been updated, the message Update completed is displayed. 7. Check that the current firmware version is displayed on the therapy device. 22 EN Weinmann Update Tool WM 67540b 02/2012 Error messages and acoustic signals are output on the display of the therapy device during the update process. This is part of the update process and does not indicate a malfunction of the therapy device. 4 Operation 8. If the update process could not be completed, the program displays an error message. In this case, please follow the instructions on the screen. Result The device has been updated. The therapy device has the current firmware version. 4.3 Choose the interface on the PC When the Weinmann Update Tool is being used for the first time, you may need to choose the interface on the PC. 1. In the Interfaces menu, click the interface used. or If you are not sure which interface to use: Click Automatic search. Remember that a therapy device must be connected to the PC (see "4.1 Connect the therapy device to the PC", page 20). Result The program chooses the interface connecting the therapy device to the PC. 4.4 Identify device WM 67540b 02/2012 You can find out which software version is currently loaded on your therapy device by identifying the device. 1. Click the Identify device button. Result The device type and the current version of the therapy device are displayed. Weinmann Update Tool EN 23 4 Operation You do not need to identify the therapy device in order to perform an update. The program automatically recognizes the device type and the version during the update process. 4.5 Change language You can choose between English, French and German. The language of the operating system is selected during the installation process. 1. Select the language you want in the Languages menu. 2. Click OK to acknowledge the message. 3. Restart the Weinmann Update Tool. The language is changed. WM 67540b 02/2012 Result 24 EN Weinmann Update Tool Sommaire Sommaire Français 1 1.1 Introduction 26 Description du produit ...................................................................26 1.2 Qualification de l’utilisateur ...........................................................26 1.3 Conditions requises .......................................................................26 2 3 4 Sécurité Installation Utilisation 27 27 31 Connexion de l'appareil de thérapie et de l'ordinateur ...................31 4.2 Mise à jour du Firmware de l'appareil de thérapie ..........................32 4.3 Sélection du port sur l'ordinateur ...................................................34 4.4 Identification de l'appareil .............................................................34 4.5 Modification de la langue ..............................................................35 WM 67540b 02/2012 4.1 Weinmann Update Tool FR 25 1 Introduction 1 Introduction 1.1 Description du produit Le Weinmann Update Tool vous permet de mettre à jour le Firmware des appareils de thérapie Weinmann. Le Weinmann Update Tool se compose des éléments suivants : • Câble de conversion USB-RS485 (WM 93318) • Câble de connexion duplex intégral (WM 93308) (VentilogicLS/Plus) • Câble de raccordement (WM 93319) (Ventimotion 2) • CD avec Weinmann Update Tool Le Firmware actuel pour l'appareil de thérapie peut être téléchargé sous www.weinmann.de dans la rubrique Login. En cas de questions ou de retours d'informations, veuillez-vous adresser au service technique : Téléphone : +49-(0) 40- 5 47 02-101 Courriel : [email protected] 1.2 Qualification de l’utilisateur • Revendeurs agréés par Weinmann • Spécialistes du produit et personnel de maintenance de Weinmann 1.3 Conditions requises Afin d'utiliser le Weinmann Update Tool, vous avez besoin d'un ordinateur équipé de la manière suivante : • 26 FR Windows XP (Service Pack 3) Weinmann Update Tool WM 67540b 02/2012 Cette notice de mise à jour s'adresse exclusivement aux personnes suivantes : 2 Sécurité 2 • Port USB • Droits d'administrateur Sécurité Risque de blessure si la mise à jour de l'appareil de thérapie est réalisée pendant la thérapie ! La mise à jour de l'appareil de thérapie pendant cette dernière peut mettre en danger le patient. ⇒ Ne jamais utiliser le Weinmann Update Tool lorsqu'un patient est raccordé à l'appareil de thérapie. 3 Installation 1. Insérer le CD dans l'ordinateur. WM 67540b 02/2012 2. Exécuter le fichier WeinmannUpdateSetup.exe. L'assistant d'installation démarre. 3. Cliquer sur le bouton Suivant. Weinmann Update Tool FR 27 3 Installation 4. Sélectionner si une icône pour le programme doit être présente dans le menu Démarrer et sur le bureau. 6. Le cas échéant : sélectionner le répertoire cible dans lequel le Weinmann Update Tool doit être enregistré. 28 FR Weinmann Update Tool WM 67540b 02/2012 5. Cliquer sur le bouton Suivant. 3 Installation 7. Cliquer sur le bouton Installer. Une boîte de dialogue d'installation du pilote du câble du convertisseur USB-RS485 s'ouvre. 8. Cliquer sur le bouton Install (Installer) afin d'installer le pilote. L'assistant d'installation recherche les fichiers correspondants. Selon l'ordinateur, ce processus peut durer quelques instants. WM 67540b 02/2012 9. Lorsque le message Installation logicielle s'affiche : cliquer sur le bouton Continuer. Ce message s'affiche dans des cas exceptionnels. Votre système d'exploitation en est la cause. Vous pourrez poursuivre sans soucis l'installation. 10. Confirmer la fin de l'installation du pilote par OK. L'assistant d'installation de JavaTM s'ouvre. Weinmann Update Tool FR 29 3 Installation 11. Si JavaTM n'est pas encore installé sur votre ordinateur : cliquer sur le bouton Installer. JavaTM est installé. 13. Cliquer sur le bouton Fermer afin de terminer l'installation. 30 FR Weinmann Update Tool WM 67540b 02/2012 12. A l'issue de l'installation : cliquer sur le bouton Fermer. L'assistant d'installation effectue l'installation. 4 Utilisation Résultat 4 L'installation est terminée. Le Weinmann Update Tool peut être utilisé. Utilisation 4.1 Connexion de l'appareil de thérapie et de l'ordinateur 1 2 1. Connecter l'appareil de thérapie au câble de données en duplex intégral (WM 93308 / VentilogicLS/Plus) / câble de raccordement (WM 93319 / Ventimotion 2) 1. 2. Connecter le câble de connexion en duplex intégral (WM 93308 / VentilogicLS/Plus) / câble de raccordement (WM 93319 / Ventimotion 2) 1 avec le câble du convertisseur USB-RS485 2. 3. Connecter le câble du convertisseur USB-RS485 2 à un port USB libre sur l'ordinateur. WM 67540b 02/2012 4. Connecter l'appareil de thérapie à une prise de courant. L’appareil de thérapie passe en mode veille. Le logo Weinmann s'affiche à l'écran. Résultat L'appareil de thérapie et l'ordinateur sont connectés. Weinmann Update Tool FR 31 4 Utilisation 4.2 Mise à jour du Firmware de l'appareil de thérapie Risque de blessure si la mise à jour de l'appareil de thérapie est réalisée pendant la thérapie ! La mise à jour de l'appareil de thérapie pendant cette dernière peut mettre en danger le patient. ⇒ Ne jamais utiliser le Weinmann Update Tool lorsqu'un patient est raccordé à l'appareil de thérapie. Dommages matériels en débranchant les connexions ! La coupure de la connexion entre le secteur, l'appareil de thérapie et l'ordinateur pendant la mise à jour peut endommager l'appareil de thérapie. ⇒ Ne pas débrancher la connexion entre l'appareil de thérapie et l'ordinateur. ⇒ Ne pas débrancher l’appareil de thérapie du secteur. Condition préalable L'appareil de thérapie est connecté à l'ordinateur (voir "4.1 Connexion de l'appareil de thérapie et de l'ordinateur", page 31). 1. Démarrer le Weinmann Update Tool. 2. Uniquement lors de la première réalisation : sélectionner le port de l'ordinateur (voir "4.3 Sélection du port sur l'ordinateur", page 34). 3. Cliquer sur le bouton Ouvrir le fichier. Le fichier de mise à jour pour l'appareil de thérapie peut être téléchargé sous www.weinmann.de dans la rubrique Login. Le fichier de mise à jour est toujours dénommé selon le nom de l'appareil de thérapie et la version du Firmware correspondant. L'extension du fichier de mise à jour est .wmu. 32 FR Weinmann Update Tool WM 67540b 02/2012 4. Sélectionner le fichier de mise à jour. 4 Utilisation 5. Cliquer sur le bouton Démarrer la mise à jour. La boîte de dialogue suivante vous permet de choisir si les paramètres de thérapie et les données des patients doivent être transférés sur la nouvelle version ou si l'appareil doit retrouver son état d'origine. 6. Cliquer sur le bouton Oui ou Non selon que vous souhaitiez conserver ou non les paramètres de thérapie et les données des patients. La mise à jour démarre. WM 67540b 02/2012 Pendant la mise à jour, l'appareil de thérapie émet des messages d'erreur et des signaux sonores. Ceci fait partie de la mise à jour et n'indique aucun dysfonctionnement de l'appareil de thérapie. Weinmann Update Tool FR 33 4 Utilisation Lorsque la mise à jour est terminée, le message Mise à jour réussie s'affiche. 7. Contrôler sur l'appareil de thérapie si la version actuelle du Firmware s'affiche. 8. Si la mise à jour n'a pas pu être terminée, le programme indique un message d'erreur. Respecter dans ce cas les instructions à l'écran. Résultat La mise à jour est terminée. L'appareil de thérapie possède la version Firmware actuelle. 4.3 Sélection du port sur l'ordinateur Lors de la première utilisation du Weinmann Update Tool, il peut être nécessaire de sélectionner le port sur l'ordinateur. 1. Dans le menu Interfaces, cliquer sur le port utilisé. ou Lorsque vous n'êtes pas sûr du port que vous utilisez : cliquer sur Recherche automatique. Faire attention aux points suivants : Un appareil de thérapie doit être connecté à l'ordinateur (voir "4.1 Connexion de l'appareil de thérapie et de l'ordinateur", page 31). Résultat Le programme sélectionne le port via lequel l'appareil de thérapie est connecté à l'ordinateur. Lorsque vous souhaitez savoir la version du logiciel actuellement installée sur votre appareil de thérapie, vous pouvez identifier l'appareil. 34 FR Weinmann Update Tool WM 67540b 02/2012 4.4 Identification de l'appareil 4 Utilisation 1. Cliquer sur le bouton Identifier l'appareil. Résultat Le type d'appareil et la version actuelle de l'appareil de thérapie sont affichés. Vous n'avez pas besoin d'identifier l'appareil de thérapue afin d'effectuer une mise à jour. Le programme reconnaît automatiquement le type d'appareil et la version pendant la mise à jour. 4.5 Modification de la langue Vous pouvez choisir entre les langues allemand, anglais et français. Lors de l'installation, la langue du système d'exploitation est sélectionnée. 1. Sélectionner la langue souhaitée dans le menu Langues. 2. Valider le message par OK. WM 67540b 02/2012 3. Redémarrer le Weinmann Update Tool. Résultat La langue est modifiée. Weinmann Update Tool FR 35 Zentrum für Produktion, Logistik, Service Weinmann Geräte für Medizin GmbH+Co. KG Siebenstücken 14 • D-24558 Henstedt-Ulzburg WM 67540b 02/2012 Weinmann Geräte für Medizin GmbH+Co. KG Postfach 540268 • D-22502 Hamburg Kronsaalsweg 40 • D-22525 Hamburg T: +49-(0)40-5 47 02-0 F: +49-(0)40-5 47 02-461 E: [email protected] www.weinmann.de