ET200pro_Erg pr _HTG_20130101_EN
Transcrição
ET200pro_Erg pr _HTG_20130101_EN
ET 200pro Supplementary products ET 200pro Supplementary products Order note: The articles and order numbers listed in this catalogue are special numbers, which were created within the context of the partnership between SIEMENS and HARTING. Order processing is only possible within the framework of this partnership for the SIEMENS product range. Prices (UPE) at this Catalogue are recommended sales prices. A binding quotation with your conditions you will receive via your responsible HARTING subsidiary company. If you don’t find the right products for your application, please contact the support for technical questions. If you need UL Traceability or UL certifies cable assemblies please contact us also. We create you shortly an offer. Send your inquiry to the central contact: mailto:[email protected] Contact and ordering address: For technical questions: HARTING Deutschland GmbH & Co. KG Heike Sielaff Tel. +49 571 8896-223 Simeonscarré 1 32427 Minden Andreas Scheuer Tel. +49 571 8896-263 and Sven Wessel Tel. +49 571 8896-335 Version 2013/01 Page 2 ET 200pro Supplementary products ET 200pro Table of contents 1. Energy – Connection ----------------------------------------------------------------------------------6 1.1 Energy T-terminal connector --------------------------------------------------------------------6 1.2 Power double T-terminal connector ------------------------------------------------------------6 1.3 Energy T-Terminal with 24V DC/2A Power supply -----------------------------------------7 1.4 Energie T-Connector with maintenance switch -----------------------------------------------7 1.5 Seals of energy T-Terminal connectors --------------------------------------------------------8 1.6 Han Q4/2 Power T---------------------------------------------------------------------------------8 1.7 Selective module Han Q4/2 ----------------------------------------------------------------------8 1.8 Adapter HAN Brid/EcoFast to 7/8" and M12 -------------------------------------------------9 1.9 Power T-connector for power bus max. 25mm² ----------------------------------------------9 1.10 Power bus cable sold by ring ------------------------------------------------------------------ 10 1.10.1 Power bus cable 5x2,5mm² -------------------------------------------------------------- 10 1.10.2 Power bus cable 5x4mm²----------------------------------------------------------------- 10 1.10.3 Power bus cable 5x6mm²----------------------------------------------------------------- 10 2 Power – cable ------------------------------------------------------------------------------------------ 11 2.1 Power cables for motor starter (MS) prefabricated ----------------------------------------- 11 2.1.1 Cross section 2,5mm² --------------------------------------------------------------------- 11 2.1.2 Cross section 4mm² ----------------------------------------------------------------------- 11 2.1.3 Cross section 6mm² ----------------------------------------------------------------------- 12 2.2 Power cables for motor starter (MS) one-sided prefabricated --------------------------- 12 2.2.1 Cross section 2,5mm² --------------------------------------------------------------------- 12 2.2.2 Cross section 4mm² ----------------------------------------------------------------------- 13 2.2.3 Cross section 6mm² ----------------------------------------------------------------------- 13 2.3 Power cable for RSM prefabricated ---------------------------------------------------------- 14 2.3.1 Cross section 2,5mm² --------------------------------------------------------------------- 14 2.3.2 Cross section 4mm² ----------------------------------------------------------------------- 14 2.3.3 Cross section 6mm² ----------------------------------------------------------------------- 15 2.4 Power cable for (RSM) one-sided prefabricated-------------------------------------------- 15 2.4.1 Cross section 2,5mm² --------------------------------------------------------------------- 15 2.4.2 Cross section 4mm² ---------------------------------------------------------------------- 16 2.4.3 Cross section 6mm² ---------------------------------------------------------------------- 16 2.5 Power cables sold by the ring ------------------------------------------------------------------ 16 2.5.1 Power cables 4x2,5mm² ------------------------------------------------------------------ 16 2.5.2 Power cables 4x4mm² -------------------------------------------------------------------- 16 2.5.3 Power cables 4x6mm² -------------------------------------------------------------------- 16 2.6 Connector set for power cable ----------------------------------------------------------------- 17 2.7 Power transfer from RSM / Motor Starter (MS) to motor starter (MS), prefabricated 18 2.7.1 Cross section 2,5mm² --------------------------------------------------------------------- 18 2.7.2 Cross section 4mm² ----------------------------------------------------------------------- 18 Version 2013/01 Page 3 ET 200pro Supplementary products 2.7.3 Cross section 6mm² ----------------------------------------------------------------------- 19 2.8 Power transfers from motor starter (MS) to RSM prefabricated ------------------------- 19 2.8.1 Cross section 2,5mm² --------------------------------------------------------------------- 19 2.8.2 Cross section 4mm² ----------------------------------------------------------------------- 20 2.8.3 Cross section 6mm² ----------------------------------------------------------------------- 20 2.9 Set of connectors for power transfer ---------------------------------------------------------- 21 3 Motor connection ------------------------------------------------------------------------------------- 22 3.1 Motor cable for motors in star connection, without brake, with or without EMC protective circuit, prefabricated ------------------------------------------------------------------------ 23 3.1.1 No EMC protective circuit (electronic motor starter)-------------------------------- 23 3.1.1.1 Cross section 1,5mm² ------------------------------------------------------------------ 23 3.1.1.2 Cross section 2,5mm² ------------------------------------------------------------------ 24 3.1.2 Build in EMC protective circuit (motor starter) -------------------------------------- 24 3.1.2.1 Cross section 1,5mm² ------------------------------------------------------------------ 24 3.1.2.2 Cross section 2,5mm² ------------------------------------------------------------------ 24 3.2 Motor cable for motors in star connection, with or without brake, one-sided prefabricated ----------------------------------------------------------------------------------------------- 25 3.2.1 Without brake ------------------------------------------------------------------------------ 25 3.2.1.1 Cross section 1,5mm² ------------------------------------------------------------------ 25 3.2.1.2 Cross section 2,5mm² ------------------------------------------------------------------ 25 3.2.2 With brake ---------------------------------------------------------------------------------- 26 3.2.2.1 Cross section 1,5mm² ------------------------------------------------------------------ 26 3.2.2.2 Cross section 2,5mm² ------------------------------------------------------------------ 26 3.3 Motor cable for motor in star connection with brake, with and without EMC protective circuit, prefabricated ------------------------------------------------------------------------ 27 3.3.1 Without EMC protective circuit (electronic motor starter) ------------------------- 27 3.3.1.1 Cross section 1,5mm² ------------------------------------------------------------------ 27 3.3.1.2 Cross section 2,5mm² ------------------------------------------------------------------ 28 3.3.2 With protective circuit (motor starter) ------------------------------------------------- 28 3.3.2.1 Cross section 1,5mm² ------------------------------------------------------------------ 28 3.3.2.2 Cross section 2,5mm² ------------------------------------------------------------------ 28 3.4 Motor cable 1,5mm² - sold by the ring ------------------------------------------------------- 29 3.5 Motor cable 2,5mm² sold by the ring --------------------------------------------------------- 29 3.6 Set of connector for motor connection cable on the side of the motor starter (MS) -- 29 3.7 Sets of connectors on the side of the motor ------------------------------------------------- 30 3.7.1 Without EMC protective circuit --------------------------------------------------------- 30 3.7.2 With EMC protective circuit------------------------------------------------------------- 30 4 Motor connection ------------------------------------------------------------------------------------- 31 4.1 Motor cable (shielded) for motors in star-connection with brake and temperature transmitter -------------------------------------------------------------------------------------------------- 31 4.1.1 Cross section 4x1,5mm² + 2x (2x0,75mm²) ------------------------------------------- 31 4.1.2 Cross section 4x2,5mm² + 2x (2x0,75mm²) ------------------------------------------- 31 4.1.3 Cross section 4x4mm² + (2x1,0mm² + 2x1,5mm²) ----------------------------------- 32 4.1.4 Adapter cable - 4mm² Device Connection to 6mm² for UL-standards ------------ 32 4.1.5 Set of Connector for Adapter cable ----------------------------------------------------- 32 4.2 Motor cable (shielded) for motors in star connection with brake and temperature transmitter -------------------------------------------------------------------------------------------------- 33 4.2.1 Cross section 4x1,5mm² + 2x (2x0,75mm²) ------------------------------------------- 33 4.2.2 Cross section 4x2,5mm² + 2x (2x0,75mm²) ------------------------------------------- 33 Version 2013/01 Page 4 ET 200pro Supplementary products 4.2.3 Cross section 4x4mm² + (2x1,0mm² + 2x1,5mm²) ----------------------------------- 34 4.2.4 Cross section 4x4mm² + (2x1,0mm² + 2x1,5mm²) ----------------------------------- 34 4.2.5 Set of connectors for adapter cable ----------------------------------------------------- 34 4.3 Motor cable (shielded) for motors ------------------------------------------------------------ 35 4.3.1 Motor cable (shielded) for motors with brake and temperature transmitter, onesided fabricated ---------------------------------------------------------------------------------------- 35 4.3.1.1 Cross section 1,5mm² ------------------------------------------------------------------ 35 4.3.1.2 Cross section 2,5mm² ------------------------------------------------------------------ 35 4.3.1.3 Cross section 4mm² -------------------------------------------------------------------- 36 4.3.2 Motor cable (shielded) for motors, one-sided fabricated ---------------------------- 36 4.3.2.1 Cross section 1,5mm² ------------------------------------------------------------------ 36 4.3.2.2 Cross section 2,5mm² ------------------------------------------------------------------ 37 4.3.2.3 Cross section 4mm² -------------------------------------------------------------------- 37 4.4 Motor cable 4x1,5mm² + 2x(2x0,75mm²) sold by ring ------------------------------------ 37 4.4.1 Motor cable 4x1,5mm² (sold by ring) -------------------------------------------------- 37 4.5 Motor cable 4x2,5mm² + 2x(2x0,75mm²) sold by ring ------------------------------------ 38 4.5.1 Motor cable 4x2,5mm² (sold by ring) -------------------------------------------------- 38 4.6 Motor cable 4x4mm² + (2x1,0mm² + 2x1,5mm²) sold by ring --------------------------- 38 4.6.1 Motor cable 4x4mm² (sold by ring) ---------------------------------------------------- 38 4.7 Motor cable 4x6mm² + 2x(2x1,0mm²) sold by ring UL-Norm – adapter cable ----- 38 4.8 Sets of connectors (shielded) for motor connection cable on the side of the converter --------------------------------------------------------------------------------------------------- 39 4.9 Set of connectors (shielded) for motor connection cable on the side of the motor --- 40 5 Accessorie ---------------------------------------------------------------------------------------------- 41 5.1 5.2 5.3 5.4 Set of connectors for power bus switching cabinet / subdistributor -------------------- 41 Protective cover ---------------------------------------------------------------------------------- 42 Crimping tool------------------------------------------------------------------------------------- 42 Dismantle tool for male and female inserts -------------------------------------------------- 42 6 Technical Datasheets -------------------------------------------------------------------------------- 43 7 Index list of product’s ------------------------------------------------------------------------------107 8 List of HARTING Subsidiaries ------------------------------------------------------------------112 Version 2013/01 Page 5 ET 200pro Supplementary products 1. Energy – Connection 1.1 Energy T-terminal connector Seal - 1 set required, see section 1.5 Order Number HTG:61 88 201 0500 HTG:61 88 201 0501 HTG:61 88 201 0502 HTG:61 88 201 0503 HTG:61 88 201 0504 1.2 Description UPE € Energy T-terminal connector for power bus cable from 2,5mm² up to 4mm² With built-in 7-pole connector, female insert, hood Energy T-terminal connector for power bus cable from 4mm² up to 6mm² With built-in 7-pole connector, female insert, hood Energy T-terminal connector Length 2,5m and 7-pole connector, female insert, hood for power bus cable from 2,5mm² till 4mm² with connected cable 5 x 2,5mm² for power bus cable from 4mm² till 6mm² with connected cable 5 x 4mm² for power bus cable from 4mm² till 6mm² with connected cable 5 x 6mm² 32,22 32,22 45,95 49,15 53,92 Power double T-terminal connector Seal - 1 set required, see section 1.5 2xHAN Q4/2-Female Order Number HTG:61 88 202 0770 Version 2013/01 Page 6 Description Power double T-terminal connector for bus cable from 4mm² up to 6mm² With two built-in 7-pole connector, female insert, hood, CSA UPE € 51,73 ET 200pro Supplementary products 1.3 Energy T-Terminal with 24V DC/2A Power supply Seal - 1 set required, see section 1.5 HanQ 4/2 Socket Order number HTG:61 88 201 0506 HTG:61 88 202 0507 HTG:61 88 202 0508 HTG:61 88 202 0509 1.4 Description Energy T-Terminal for power bus cable for 4mm² - 6mm², with built in 7-pole female connector, hood and 24V DC/2A power supply with 2x M12 female 24V DC power supply cable for T-Terminal connectors with power supply M12 connector, straight, angled to 7/8 Socket Length 1,5m Length 3m Length 5m UPE € 199,50 Energie T-Connector with maintenance switch Seal - 1 set required, see section 1.5 HanQ 4/2 Socket Order number HTG:61 88 201 0505 Version 2013/01 Page 7 Description Power T-Terminal connector for power bus cable for 4mm² - 6mm² with built-in 7-pole connector, female insert, Hood, with lockable Main Switch UPE € 147,52 ET 200pro Supplementary products 1.5 Seals of energy T-Terminal connectors Order number HTG:61 83 401 0200 HTG:61 83 401 0201 HTG:61 83 401 0202 HTG:61 83 401 0203 HTG:61 83 401 0204 1.6 Description Sealing for cable 10 - 13mm 1 Set = 2 pieces Sealing for cable 13 - 16mm 1 Set = 2 pieces Sealing for cable 16 - 19mm 1 Set = 2 pieces Sealing for cable 19 - 22mm 1 Set = 2 pieces Sealing blind grommet 1 piece UPE € Description Han Q4/2 Power T, 3x pluggable, Supply via Han Q4/2 connector Leaving 2x Han Q4/2 socket with high hood UPE € 1,38 1,38 1,38 1,38 0,88 Han Q4/2 Power T Order number HTG:61 88 203 0017 Prices on request 1.7 Selective module Han Q4/2 Order number HTG:61 88 201 0330 Version 2013/01 Page 8 Description Selectively block Han Q4/2 Designed as isolator and maintenance switch with M12 socket for NC/NO message UPE € 145,00 ET 200pro Supplementary products 1.8 Adapter HAN Brid/EcoFast to 7/8" and M12 Order number Description HTG:61 88 203 0016 Adapter for ET200 pro without Han Brid connector. Han Brid male to Profibus M12 and DC-Power 7/8” incl. bracket for the mounting rail The connection is made through a SIMATEC NET Profibus ECOFAST Hybrid connection. UPE € Prices on request 1.9 Power T-connector for power bus max. 25mm² Han Q4/2 Order Number HTG:61 88 201 0181 Version 2013/01 Page 9 Description Power T-terminal connector for power bus cable up to 25mm² for power bus cross sectional change or power bus extension Glands M25 for cable cross section from 13 mm up to 18 mm With built-in 7-pole connector, female insert, hood UPE € 70,22 ET 200pro Supplementary products 1.10 Power bus cable sold by ring 1.10.1 Power bus cable 5x2,5mm² Order Number HTG:61 88 600 0101 HTG:61 88 600 0102 On request Description Power bus cable, CSA 5x2,5mm² Length 50m Length 100m Length >100m UPE € 220,52 426,10 1.10.2 Power bus cable 5x4mm² Order Number HTG:61 88 600 0107 HTG:61 88 600 0108 On request Description Power bus cable, CSA 5x4mm² Length 50m Length 100m Length >100m UPE € 312,02 609,03 1.10.3 Power bus cable 5x6mm² Order Number HTG:61 88 600 0113 HTG:61 88 600 0114 On request Version 2013/01 Page 10 Description Power bus cable, CSA 5x6mm² Length 50m Length 100m Length >100m UPE € 450,37 885,77 ET 200pro Supplementary products 2 Power – cable 2.1 Power cables for motor starter (MS) prefabricated 7-pole (plug) axial cable feed HanQ 4/2 Housing (with bracket) male insert 7-pole (socket) angled cable feed HanQ 4/2 Hood, side entry Female insert 2.1.1 Cross section 2,5mm² Order number HTG:61 88 202 0400 HTG:61 88 202 0401 HTG:61 88 202 0402 HTG:61 88 202 0403 Description Power cable MS for ET 200pro, ECOFAST HAN Q4/2 top entry - HAN Q4/2 side entry 4x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € Description Power cable MS for ET 200pro, ECOFAST HAN Q4/2 top entry - HAN Q4/2 side entry 4x4mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 43,93 50,09 58,29 78,81 2.1.2 Cross section 4mm² Order number HTG:61 88 202 0404 HTG:61 88 202 0405 HTG:61 88 202 0406 HTG:61 88 202 0407 Version 2013/01 Page 11 46,91 55,86 67,76 97,57 ET 200pro Supplementary products 2.1.3 Cross section 6mm² Order number Description Power cable MS for ET 200pro, ECOFAST HAN Q4/2 top entry - HAN Q4/2 side entry 4x6mm² Length 1,5m Length 3m Length 5m Length 10m HTG:61 88 202 0408 HTG:61 88 202 0409 HTG:61 88 202 0410 HTG:61 88 202 0411 2.2 UPE € 51,77 64,83 82,27 125,82 Power cables for motor starter (MS) one-sided prefabricated open cable Open end 7-pole (socket) angled cable feed HanQ 4/2 Hood side entry Female insert 2.2.1 Cross section 2,5mm² Order number HTG:61 88 201 0192 HTG:61 88 201 0193 HTG:61 88 201 0194 HTG:61 88 201 0195 Version 2013/01 Page 12 Description Power cable MS for ET 200pro, ECOFAST open - HAN Q4/2 side entry 4x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 25,63 31,57 39,78 60,28 ET 200pro Supplementary products 2.2.2 Cross section 4mm² Order number HTG:61 88 201 0196 HTG:61 88 201 0197 HTG:61 88 201 0198 HTG:61 88 201 0199 Description Power cable MS for ET 200pro, ECOFAST open - HAN Q4/2 side entry 4x4mm² Length 1,5m Length 3m Length 5m Length 10m UPE € Description Power cable MS for ET 200pro, ECOFAST open - HAN Q4/2 side entry 4x6mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 27,88 34,94 44,67 69,02 2.2.3 Cross section 6mm² Order number HTG:61 88 201 0200 HTG:61 88 201 0201 HTG:61 88 201 0202 HTG:61 88 201 0203 Version 2013/01 Page 13 31,59 42,02 56,40 92,31 ET 200pro Supplementary products 2.3 Power cable for RSM prefabricated 7-pole (plug) Axial cable feed HanQ 4/2 Housing (with bracket) male insert 7-pole (socket) Angled cable feed Top down HanQ 4/2 Hood side entry Female insert Top down 2.3.1 Cross section 2,5mm² Order number HTG:61 88 202 0412 HTG:61 88 202 0413 HTG:61 88 202 0414 HTG:61 88 202 0415 Description Power cable RSM for ET 200pro HAN Q4/2 top entry - HAN Q4/2 side entry Insert RSM-side top down 4x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € Description Power cable RSM for ET 200pro HAN Q4/2 top entry - HAN Q4/2 side entry Insert RSM-side top down 4x4mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 43,83 50,09 58,29 78,81 2.3.2 Cross section 4mm² Order number HTG:61 88 202 0416 HTG:61 88 202 0417 HTG:61 88 202 0418 HTG:61 88 202 0419 Version 2013/01 Page 14 46,91 55,86 67,76 97,57 ET 200pro Supplementary products 2.3.3 Cross section 6mm² Order number Description Power cable RSM for ET 200pro HAN Q4/2 top entry - HAN Q4/2 side entry Insert RSM-side top down 4x6mm² Length 1,5m Length 3m Length 5m Length 10m HTG:61 88 202 0420 HTG:61 88 202 0421 HTG:61 88 202 0422 HTG:61 88 202 0423 2.4 UPE € 51,77 64,83 82,27 125,82 Power cable for (RSM) one-sided prefabricated open cable Open end 7-pole (socket) Angled cable feed top down HanQ 4/2 Hood side entry Female insert Top down 2.4.1 Cross section 2,5mm² Order number HTG:61 88 201 0310 HTG:61 88 201 0311 HTG:61 88 201 0312 HTG:61 88 202 0313 Version 2013/01 Page 15 Description Power cable RSM for ET 200pro open - HAN Q4/2 side entry Insert RSM-side top down 4x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 25,63 31,57 39,78 60,28 ET 200pro Supplementary products 2.4.2 Cross section 4mm² Order number HTG:61 88 201 0184 HTG:61 88 201 0185 HTG:61 88 201 0186 HTG:61 88 201 0187 Description Power cable RSM for ET 200pro open - HAN Q4/2 side entry Insert RSM-side top down 4x4mm² Length 1,5m Length 3m Length 5m Length 10m UPE € Description Power cable RSM for ET 200pro open - HAN Q4/2 side entry Insert RSM-side top down 4x6mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 27,88 34,94 44,67 69,02 2.4.3 Cross section 6mm² Order number HTG:61 88 201 0188 HTG:61 88 201 0189 HTG:61 88 201 0190 HTG:61 88 201 0191 2.5 31,59 42,02 56,40 92,35 Power cables sold by the ring 2.5.1 Power cables 4x2,5mm² Order number HTG:61 88 600 0115 HTG:61 88 600 0116 on request Description Power cable 4x2,5mm² Length 50m Length 100m Length >100m UPE € 175,77 353,32 2.5.2 Power cables 4x4mm² Order number HTG:61 88 600 0117 HTG:61 88 600 0118 on request Description Power cable 4x4mm² Length 50m Length 100m Length >100m UPE € 241,79 468,64 2.5.3 Power cables 4x6mm² Order number HTG:61 88 600 0119 HTG:61 88 600 0120 on request Version 2013/01 Page 16 Description Power cable 4x6mm² Length 50m Length 100m Length >100m UPE € 349,05 683,11 ET 200pro Supplementary products 2.6 Connector set for power cable 7-pole (plug) axial cable feed HanQ 4/2 Housing (with bracket) Male insert 7-pole (socket) Angled cable feed HanQ 4/2 Hood side entry Female insert Top down Order number HTG:61 83 401 0244 HTG:61 83 401 0249 HTG:61 83 401 0246 HTG:61 83 401 0247 HTG:61 83 401 0248 HTG:61 83 401 0245 HTG:61 83 401 0251 Version 2013/01 Page 17 Description Set of connectors power cable e.g. for connection to the T-terminal connector consisting of housing, outgoing circuit top entry (with bracket) Male insert for Han Q4/2 Gland for cable size 9-15mm 5 male contacts 2,5mm² Gland for cable size 11,5-15,5mm 5 male contacts 4mm² Gland for cable size 12-16,5mm 5 male contacts 6mm² Set of connectors for power cable for connection to MS /RSM Hood, outgoing circuit side entry Female insert for Han Q4/2 Gland for cable size 9-15mm 5 female contacts 2,5mm² Gland for cable size 11,5-15,5mm 5 female contacts 4mm² Gland for cable size 12-16,5mm 5 female contacts 6mm² !! Field assembly !! with female insert HanQ 4/2 axial screw connection, cross section of 4-10mm² UPE € 13,18 13,18 13,18 15,24 15,24 15,24 24,96 ET 200pro Supplementary products 2.7 Power transfer from RSM / Motor Starter (MS) to motor starter (MS), prefabricated 7-pole (plug) Angled cable feed HanQ 4/2 Hood Side entry Male insert 7-pole (socket) Angled cable feed HanQ 4/2 Hood side entry Female insert 2.7.1 Cross section 2,5mm² Order number HTG:61 88 202 0340 HTG:61 88 202 0341 HTG:61 88 202 0342 HTG:61 88 202 0343 Description Power transfer RSM/MS - MS for ET 200pro HAN Q4/2 side entry - HAN Q4/2 side entry 4x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € Description Power transfer RSM/MS - MS for ET 200pro HAN Q4/2 side entry - HAN Q4/2 side entry 4x4mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 43,16 49,30 57,51 78,01 2.7.2 Cross section 4mm² Order number HTG:61 88 202 0344 HTG:61 88 202 0345 HTG:61 88 202 0346 HTG:61 88 202 0347 Version 2013/01 Page 18 43,83 50,60 59,65 82,25 ET 200pro Supplementary products 2.7.3 Cross section 6mm² Order number HTG:61 88 202 0348 HTG:61 88 202 0349 HTG:61 88 202 0350 HTG:61 88 202 0351 2.8 Description Power transfer RSM/MS - MS for ET 200pro HAN Q4/2 side entry - HAN Q4/2 side entry 4x6mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 47,26 57,28 70,64 104,02 Power transfers from motor starter (MS) to RSM prefabricated 7-pole (plug) Angled cable feed 7-pole (socket) Angled cable feed HanQ 4/2 Hood Side entry Male insert 2.8.1 Cross section 2,5mm² Order number HTG:61 88 202 0352 HTG:61 88 202 0353 HTG:61 88 202 0354 HTG:61 88 202 0355 Version 2013/01 Page 19 HanQ 4/2 Hood side entry Female insert top down Description Power transfer MS - RSM for ET 200pro HAN Q4/2 side entry - HAN Q4/2 side entry, Insert RSM-side top down 4x2,5mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 43,16 49,03 57,51 78,01 ET 200pro Supplementary products 2.8.2 Cross section 4mm² Order number HTG:61 88 202 0356 HTG:61 88 202 0357 HTG:61 88 202 0358 HTG:61 88 202 0359 2.8.3 UPE € Description Power transfer MS - RSM for ET 200pro HAN Q4/2 side entry - HAN Q4/2 side entry, Insert RSM-side top down 4x6mm² Length 1,5m Length 3m Length 5m Length 10m UPE € 43,83 50,60 59,65 82,25 Cross section 6mm² Order number HTG:61 88 202 0360 HTG:61 88 202 0361 HTG:61 88 202 0362 HTG:61 88 202 0363 Version 2013/01 Page 20 Description Power transfer MS - RSM for ET 200pro HAN Q4/2 side entry - HAN Q4/2 side entry, Insert RSM-side top down 4x4mm² Length 1,5m Length 3m Length 5m Length 10m 47,26 57,28 70,64 104,02 ET 200pro Supplementary products 2.9 Set of connectors for power transfer HanQ 4/2 Housing (angled) Male insert Order number HTG:61 04 401 1001 HTG:61 04 401 1002 HTG:61 04 401 1003 HTG:61 04 401 1004 Version 2013/01 Page 21 Connector 7-pole (plug) Angled cable feed Connector 7-pole (socket) Angled cable Description Set of connectors for power transfer for connection to MS /RSM Hood, outgoing circuit side entry Male insert for Han Q4/2 Gland for cable size 9 – 13 mm 5 male contacts 4mm² 5 male contacts 6mm² Set of connectors for power cable for connection to MS /RSM Hood, outgoing circuit side entry Female insert for Han Q4/2 Gland for cable size 9 – 13 mm 5 female contacts 4mm² 5 female contacts 6mm² HanQ 4/2 Hood side entry Female insert top down UPE € 14,46 14,46 12,05 12,05 ET 200pro Supplementary products 3 Motor connection Attention! For motor starters, you have to use an EMC protective circuit • If a brake is used • If there are motors with less than 1kW RC elements must be used as protective circuit. For electronic starters, a protective circuit must not be used, not even when a brake is used! Version 2013/01 Page 22 ET 200pro Supplementary products 3.1 Motor cable for motors in star connection, without brake, with or without EMC protective circuit, prefabricated Motor – connection cable with HanQ 8/0 connector Motor Han 10 E female insert 9-pole (plug) angled cable feed Motor cable 4 x XXm² 10-pole (socket) axial cable feed Motor with HanDrive 3.1.1 No EMC protective circuit (electronic motor starter) 3.1.1.1 Cross section 1,5mm² Order number HTG:61 88 202 0424 HTG:61 88 202 0425 HTG:61 88 202 0426 Version 2013/01 Page 23 Description Motor cable for MS ET 200pro, ET 200X, AS-i compact with star jumper for motor without brake without EMC protective circuit HAN Q8 side entry - HAN 10E 4x1,5mm² Length 1,5m Length 3m Length 5m UPE € 42,84 47,12 52,80 ET 200pro Supplementary products 3.1.1.2 Cross section 2,5mm² Order number HTG:61 88 202 0427 HTG:61 88 202 0428 HTG:61 88 202 0429 3.1.2 Description Motor cable for MS ET 200pro, ET 200X, AS-i compact with star jumper for motor without brake without EMC protective circuit HAN Q8 side entry - HAN 10E 4x2,5mm² Length 1,5m Length 3m Length 5m UPE € 43,47 48,31 54,79 Build in EMC protective circuit (motor starter) 3.1.2.1 Cross section 1,5mm² Order number HTG:61 88 202 0600 HTG:61 88 202 0601 HTG:61 88 202 0602 Description Motor cable for MS ET 200pro, ET 200X, AS-i compact with star jumper for motor without brake build in EMC protective circuit HAN Q8 side entry - HAN 10E 4x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for MS ET 200pro, ET 200X, AS-i compact with star jumper for motor without brake build in EMC protective circuit HAN Q8 side entry - HAN 10E 4x2,5mm² Length 1,5m Length 3m Length 5m UPE € 62,54 66,82 72,50 3.1.2.2 Cross section 2,5mm² Order number HTG:61 88 202 0603 HTG:61 88 202 0604 HTG:61 88 202 0605 Version 2013/01 Page 24 63,17 68,02 74,49 ET 200pro Supplementary products 3.2 Motor cable for motors in star connection, with or without brake, one-sided prefabricated Motor – connection cable with HanQ 8/0 connector (MS) and end open 3.2.1 9-pole (plug) angled cable feed Motor cable 4 x XXm² Open cable Without brake 3.2.1.1 Cross section 1,5mm² Order number HTG:61 88 201 0211 HTG:61 88 201 0212 HTG:61 88 201 0213 Description Motor cable for MS ET 200pro, ET 200X, AS-i compact for motor without brake HAN Q8 side entry - open 4x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for MS ET 200pro, ET 200X, AS-i compact for motor without brake HAN Q8 side entry - open 4x2,5mm² Length 1,5m Length 3m Length 5m UPE € 19,70 23,83 29,51 3.2.1.2 Cross section 2,5mm² Order number HTG:61 88 201 0214 HTG:61 88 201 0215 HTG:61 88 201 0216 Version 2013/01 Page 25 20,31 25,01 31,48 ET 200pro Supplementary products 3.2.2 With brake 3.2.2.1 Cross section 1,5mm² Order number HTG:61 88 201 0218 HTG:61 88 201 0219 HTG:61 88 201 0220 Description Motor cable for MS ET 200pro, ET 200X, AS-i compact for motor with brake HAN Q8 side entry - open 6x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for MS ET 200pro, ET 200X, AS-i compact for motor with brake HAN Q8 side entry - open 6x2,5mm² Length 1,5m Length 3m Length 5m UPE € 20,86 25,61 32,24 3.2.2.2 Cross section 2,5mm² Order number HTG:61 88 201 0221 HTG:61 88 201 0222 HTG:61 88 201 0223 Version 2013/01 Page 26 21,46 27,88 34,21 ET 200pro Supplementary products 3.3 Motor cable for motor in star connection with brake, with and without EMC protective circuit, prefabricated 9-pole (plug) angled cable feed Motor – connection cable with HanQ 8/0 connector (MS) and Han 10 E female insert (motor) Motor cable 6 x XXm² With EMC protective circuit 10-pole (socket) axial cable feed Motor with HanDrive 3.3.1 Without EMC protective circuit (electronic motor starter) 3.3.1.1 Cross section 1,5mm² Order number HTG:61 88 202 0607 HTG:61 88 202 0608 HTG:61 88 202 0609 Version 2013/01 Page 27 Description Motor cable for MS ET 200pro, ET 200X with star jumper for motor with brake without EMC protective circuit HAN Q8 side entry - HAN 10E 6x1,5mm² Length 1,5m Length 3m Length 5m UPE € 43,89 47,89 55,84 ET 200pro Supplementary products 3.3.1.2 Cross section 2,5mm² Order number HTG:61 88 202 0610 HTG:61 88 202 0611 HTG:61 88 202 0612 3.3.2 Description Motor cable for MS ET 200pro, ET 200X with star jumper for motor with brake without EMC protective circuit HAN Q8 side entry - HAN 10E 6x2,5mm² Length 1,5m Length 3m Length 5m UPE € 45,04 51,25 59,51 With protective circuit (motor starter) 3.3.2.1 Cross section 1,5mm² Order number HTG:61 88 202 0430 HTG:61 88 202 0431 HTG:61 88 202 0432 Description Motor cable for MS ET 200pro, ET 200X with star jumper for motor with brake and EMC protective circuit HAN Q8 side entry - HAN 10E 6x1,5mm² Length 1,5m Length 3m Length 5m UPE € Description Motor cable for MS ET 200pro, ET 200X with star jumper for motor with brake and EMC protective circuit HAN Q8 side entry - HAN 10E 6x2,5mm² Length 1,5m Length 3m Length 5m UPE € 63,59 67,68 75,54 3.3.2.2 Cross section 2,5mm² Order number HTG:61 88 202 0433 HTG:61 88 202 0434 HTG:61 88 202 0435 Version 2013/01 Page 28 64,75 70,95 79,21 ET 200pro Supplementary products 3.4 Motor cable 1,5mm² - sold by the ring Order number HTG:61 88 600 0121 HTG:61 88 600 0122 HTG:61 88 600 0123 HTG:61 88 600 0124 3.5 UPE € 43,41 157,20 48,59 183,06 Motor cable 2,5mm² sold by the ring Order number HTG:61 88 600 0125 HTG:61 88 600 0126 HTG:61 88 600 0127 HTG:61 88 600 0128 3.6 Description Motor cable sold by the ring 4x1,5mm² Length 10m Length 50m Motor cable sold by the ring 6x1,5mm² Length 10m Length 50m Description Motor cable sold by the ring 4x2,5mm² Length 10m Length 50m Motor cable sold by the ring 6x2,5mm² Length 10m Length 50m UPE € 47,24 176,38 56,30 221,57 Set of connector for motor connection cable on the side of the motor starter (MS) 9-pole (socket) axial cable feed Connecting cable – Motor with HanQ 8/0 Plug Motor with HanDrive Order number HTG:61 83 401 0065 HTG:61 83 401 0066 Version 2013/01 Page 29 Description Set of connectors for motor cable for connection to MS Hood, outgoing circuit side entry Male insert for Han Q8/0 Gland for cable size 9 –13 mm 8 male contacts 1,5mm² … for cable size 11,5 –15,5 mm 8 male contacts 2,5mm² UPE € 9,05 9,05 ET 200pro Supplementary products 3.7 Sets of connectors on the side of the motor Han 10E Socket (Motor) 10-pole (socket) axial cable feed Motor with HanDrive 3.7.1 Without EMC protective circuit Order number HTG:61 83 401 0047 HTG:61 83 401 0067 Description Set of connectors for motor cable for connection to Motor Star jumper Hood Female insert for Han 10e Gland for cable size 9 – 13 mm 7 female contacts 1,5mm² 11 – 15,5 mm 7 female contacts 2,5mm² UPE € 17,92 17,92 3.7.2 With EMC protective circuit Order number HTG:61 83 401 0068 HTG:61 83 401 0069 Version 2013/01 Page 30 Description Set of connectors for motor cable for connection to Motor Star jumper and EMC protective circuit Hood Female insert for Han 10e Gland for cable size 9 – 13 mm 7 female contacts 1,5mm² 11 – 15,5 mm 7 female contacts 2,5mm² UPE € 41,58 41,58 ET 200pro Supplementary products 4 Motor connection 4.1 Motor cable (shielded) for motors in star-connection with brake and temperature transmitter 9-pole (socket) shielded axial cable feed Motor cable shielded 4x Xmm² + 2x (2x0,75mm²) 10-pole (socket) shielded Axial cable feed Motor with HanDrive 4.1.1 Cross section 4x1,5mm² + 2x (2x0,75mm²) Order number HTG:61 88 202 0499 HTG:61 88 202 0514 HTG:61 88 202 0515 Description motor cable for FC, shielded star jumper HAN Q8 - HAN 10E 4x1,5mm² + 2x(2x0,75mm²) Length 1,5m Length 3m Length 5m UPE € 102,56 121,32 146,36 4.1.2 Cross section 4x2,5mm² + 2x (2x0,75mm²) Order number HTG:61 88 202 0500 HTG:61 88 202 0520 HTG:61 88 202 0521 Version 2013/01 Page 31 Description motor cable for FC, shielded star jumper HAN Q8 - HAN 10E 4x2,5mm² + 2x(2x0,75mm²) Length 1,5m Length 3m Length 5m UPE € 105,53 124,86 150,64 ET 200pro Supplementary products 4.1.3 Cross section 4x4mm² + (2x1,0mm² + 2x1,5mm²) Order number HTG:61 88 202 0522 HTG:61 88 202 0523 HTG:61 88 202 0524 Description motor cable for FC, shielded star jumper HAN Q8 - HAN 10E 4x4mm² + (2x 1,0mm² + 2x1,5mm²) Length 1,5m Length 3m Length 5m UPE € 133,98 153,41 179,17 4.1.4 Adapter cable - 4mm² Device Connection to 6mm² for UL-standards Order number HTG:61 88 202 0497 Description motor cable for FU, shielded HAN Q8 - HAN 10 modular 4x4mm² + (2x 1,0mm² + 2x1,5mm²) Length 0,3m UPE € 153,27 4.1.5 Set of Connector for Adapter cable Order number HTG:61 83 401 0130 Version 2013/01 Page 32 Description Cross section 4x6 + (2x1,0mm²+2x1,5mm²) HAN 10 modular 4x contacts 6mm² + 2x contacts 1mm² + 2x contacts 1,5mm² Hood + male insert 4-pole + male insert 6-pole UPE € 72,06 ET 200pro Supplementary products 4.2 Motor cable (shielded) for motors in star connection with brake and temperature transmitter 9-pole (socket) shielded axial cable feed Motor cable shielded 4x Xmm² + 2x (2x0,75mm²) 10-pole (socket) shielded Axial cable feed Motor with HanDrive 4.2.1 Cross section 4x1,5mm² + 2x (2x0,75mm²) Order number HTG:61 88 202 0525 HTG:61 88 202 0526 HTG:61 88 202 0527 Description motor cable for FC, shielded triangular jumper HAN Q8 - HAN 10E 4x1,5mm² + 2x(2x0,75mm²) Length 1,5m Length 3m Length 5m UPE € 102,98 121,84 146,78 4.2.2 Cross section 4x2,5mm² + 2x (2x0,75mm²) Order number HTG:61 88 202 0528 HTG:61 88 202 0529 HTG:61 88 202 0530 Version 2013/01 Page 33 Description motor cable for FC, shielded triangular jumper HAN Q8 - HAN 10E 4x2,5mm² + 2x(2x0,75mm²) Length 1,5m Length 3m Length 5m UPE € 105,95 125,28 151,06 ET 200pro Supplementary products 4.2.3 Cross section 4x4mm² + (2x1,0mm² + 2x1,5mm²) Order number HTG:61 88 202 0531 HTG:61 88 202 0532 HTG:61 88 202 0533 Description motor cable for FC, shielded triangular jumper HAN Q8 - HAN 10E 4x4mm² + (2x1,0mm² + 2x1,5mm²) Length 1,5m Length 3m Length 5m UPE € 167,89 196,88 230,16 4.2.4 Cross section 4x4mm² + (2x1,0mm² + 2x1,5mm²) Adapter cable - 4mm² connection on 6mm² for UL-Norm Order number HTG:61 88 202 0497 Description motor cable for FC, shielded HAN Q8 - HAN 10 modular 4x4mm² + (2x1,0mm² + 2x1,5mm²) Length 0,3m UPE € 153,27 4.2.5 Set of connectors for adapter cable Order number HTG:61 83 401 0130 Version 2013/01 Page 34 Description Cross section 4x6 + (2x1,0mm² + 2x1,5mm²) HAN 10 modular 4x Contacts 6mm² + 2x Contacts 1,0mm² + 2x Contacts 1,5mm² Housing + Module male insert 4 pole +Module male insert 6pole UPE € 72,06 ET 200pro Supplementary products 4.3 Motor cable (shielded) for motors 4.3.1 Motor cable (shielded) for motors with brake and temperature transmitter, one-sided fabricated 9-pole (socket) shielded axial cable feed Motor cable shielded 4x Xmm² + 2x (2x0,75mm²) End open 4.3.1.1 Cross section 1,5mm² Order number HTG:61 88 201 0288 HTG:61 88 201 0289 HTG:61 88 201 0290 HTG:61 88 201 0299 HTG:61 88 201 0300 Description motor cable for FC, shielded HAN Q8 - open 4x1,5mm² + 2x(2x0,75mm²) Length 1,5m Length 3m Length 5m Length 10m Length 15m UPE € 73,65 91,36 116,71 177,34 237,98 4.3.1.2 Cross section 2,5mm² Order number HTG:61 88 201 0291 HTG:61 88 201 0292 HTG:61 88 201 0293 HTG:61 88 201 0301 HTG:61 88 201 0302 Version 2013/01 Page 35 Description motor cable for FC, shielded HAN Q8 - open 4x2,5mm² + 2x(2x0,75mm²) Length 1,5m Length 3m Length 5m Length 10m Length 15m UPE € 74,26 93,15 118,07 181,07 243,22 ET 200pro Supplementary products 4.3.1.3 Cross section 4mm² Order number HTG:61 88 201 0303 HTG:61 88 201 0304 HTG:61 88 201 0305 HTG:61 88 201 0306 HTG:61 88 201 0307 Description motor cable for FC, shielded HAN Q8 - open 4x4mm² + (2x1,0mm² + 2x1,5mm²) Length 1,5m Length 3m Length 5m Length 10m Length 15m UPE € 110,71 133,35 165,69 246,53 272,21 4.3.2 Motor cable (shielded) for motors, one-sided fabricated 9-pole shielded 9-polig(socket) (Stift) geschirmt axial cable feed gewinkelte Kabelführung Motorleitung geschirmt Motor cable shielded 4xXmm² 4x Xmm² Offenes Ende End open 4.3.2.1 Cross section 1,5mm² Order number HTG:61 88 201 0350 HTG:61 88 201 0351 HTG:61 88 201 0352 HTG:61 88 201 0353 HTG:61 88 201 0354 Version 2013/01 Page 36 Description motor cable for FC, shielded HAN Q8 - open 4x1,5mm² Length 1,5m Length 3m Length 5m Length 10m Length 15m UPE € 63,79 78,97 100,93 153,13 205,33 ET 200pro Supplementary products 4.3.2.2 Cross section 2,5mm² Order number HTG:61 88 201 0355 HTG:61 88 201 0356 HTG:61 88 201 0357 HTG:61 88 201 0358 HTG:61 88 201 0359 Description motor cable for FC, shielded HAN Q8 - open 4x2,5mm² Length 1,5m Length 3m Length 5m Length 10m Length 15m UPE € 65,64 83,23 106,43 165,14 227,93 4.3.2.3 Cross section 4mm² Order number HTG:61 88 201 0360 HTG:61 88 201 0361 HTG:61 88 201 0362 HTG:61 88 201 0363 HTG:61 88 201 0364 4.4 Description motor cable for FC, shielded HAN Q8 - open 4x4mm² Length 1,5m Length 3m Length 5m Length 10m Length 15m UPE € 99,69 118,62 146,04 214,57 227,93 Motor cable 4x1,5mm² + 2x(2x0,75mm²) sold by ring Order number HTG:61 88 601 0004 HTG:61 88 601 0005 Description motor cable sold by meter, shielded 4x1,5mm² + 2x(2x0,75mm²) Length 10m Length 50m UPE € 136,24 621,32 4.4.1 Motor cable 4x1,5mm² (sold by ring) Order number HTG:61 88 601 0010 HTG:61 88 601 0011 Version 2013/01 Page 37 Description motor cable sold by meter, shielded 4x1,5mm² Length 10m Length 50m UPE € 119,37 536,95 ET 200pro Supplementary products 4.5 Motor cable 4x2,5mm² + 2x(2x0,75mm²) sold by ring Order number HTG:61 88 601 0006 HTG:61 88 601 0007 Description motor cable sold by meter, shielded 4x2,5mm² + 2x(2x0,75mm²) Length 10m Length 50m UPE € 140,14 640,77 4.5.1 Motor cable 4x2,5mm² (sold by ring) Order number HTG:61 88 601 0012 HTG:61 88 601 0013 4.6 Description motor cable sold by meter, shielded 4x2,5mm² Length 10m Length 50m UPE € 131,54 597,80 Motor cable 4x4mm² + (2x1,0mm² + 2x1,5mm²) sold by ring Order number HTG:61 88 601 0008 HTG:61 88 601 0009 Description motor cable sold by meter, shielded 4x4mm² + (2x1,0mm² + 2x1,5mm²) Length 10m Length 50m UPE € 214,69 1034,52 4.6.1 Motor cable 4x4mm² (sold by ring) Order number HTG:61 88 601 0014 HTG:61 88 601 0015 4.7 UPE € 190,07 911,38 Motor cable 4x6mm² + 2x(2x1,0mm²) sold by ring ULNorm – adapter cable Order number HTG:61 88 601 0016 HTG:61 88 601 0017 Version 2013/01 Page 38 Description motor cable sold by meter, shielded 4x4mm² Length 10m Length 50m Description motor cable sold by meter, shielded 4x6mm² + 2x(2x1,0mm²) Length 10m Length 50m UPE € 255,17 1249,57 ET 200pro Supplementary products 4.8 Sets of connectors (shielded) for motor connection cable on the side of the converter 9-pole (socket) shielded axial cable feed Motor with HanDrive Order number HTG:61 83 401 0131 HTG:61 83 401 0132 HTG:61 83 401 0133 HTG:61 83 401 0253 Version 2013/01 Page 39 Description Set of connectors (shielded) for motor cable for connection to FC Hood outgoing circuit side-entry male insert for Han Q8/0 Gland for cable cross section 10-13 mm 8 male contacts (4x1,5mm²+4x0,75 mm²) Gland for cable cross section 11-14 mm 8 male contacts (4x2,5mm²+4x0,75mm²) Gland for cable cross section 13-18 mm 8 male contacts (4x4mm²+4x1,0 mm²) !! Field mountable !! with male insert Han Q8/0 quick lock, Terminal cross section 0,5 – 2,5mm², two-parts hood with side-entry Cable gland for cross section 11-14mm UPE € 28,07 28,07 55,37 44,95 ET 200pro Supplementary products 4.9 Set of connectors (shielded) for motor connection cable on the side of the motor 10-pole (socket) shielded Axial cable feed Motor with HanDrive Order number HTG:61 83 401 0120 HTG:61 83 401 0121 HTG:61 83 401 0122 HTG:61 83 401 0123 HTG:61 83 401 0124 HTG:61 83 401 0125 Version 2013/01 Page 40 Description Set of connectors (shielded) for motor cable for connection at motor Star jumper Hood Female insert for Han 10e Gland for cable cross section 10 –14 mm 7 female contacts (3x1,5mm²+4x0,75mm²) 7 female contacts (3x 2,5mm²+4x0,75 mm²) Gland for cable cross section 12-18 mm² 7 female contacts (3x4mm²+4x1,0mm² Set of connectors (shielded) for motor cable for connection to motor Triangular jumper Hood Female insert for Han 10e Gland for cable cross section 10 –14 mm 10 female contacts (3x1,5mm²+3x3mm²+4x0,75mm²) 10 female contacts (3x2,5mm²+3x4mm²+4x0,75mm²) Gland for cable cross section 12-18 mm 10 female contacts(3x 4mm²x3x2,5 mm²+4x1,0mm² UPE € 34,52 34,52 55,71 34,27 34,27 54,35 ET 200pro Supplementary products 5 Accessorie 5.1 Set of connectors for power bus switching cabinet / subdistributor Set of connectors HanQ 4/2 Hood Male insert Cabinet Mounting case HanQ 4/2 Female insert Energy bus connector Male Energy bus connector Female Order number HTG: on request HTG:61 88 201 0051 Order number HTG:61 83 401 0116 HTG:61 83 401 0117 HTG:61 83 401 0118 HTG:61 83 401 0119 Version 2013/01 Page 41 Description Mounting case Consisting of housing (with bracket) Set of female inserts for Han Q4/2 5 female contacts 4mm² Mounting case consisting of Housing Set of female insert for Han Q4/2 5 female contacts 6mm² Description Set of connectors Hood, (with bracket) outgoing circuit top entry Male insert for Han Q4/2 Gland for cable size 12,5 – 16,5 mm 5 male contacts 4mm² 5 male contacts 6mm² Set of connectors Hood, (with bracket) outgoing circuit side entry Male insert for Han Q4/2 Gland for cable size 12,5 – 16,5 mm 5 male contacts 4mm² 12,5 – 16,5 mm 5 male contacts 6mm² UPE € 70,64 UPE € 14,00 14,00 15,58 15,58 ET 200pro Supplementary products 5.2 Protective cover Order number Description HTG:09 12 008 5407 Protection cover Han Q4/2 and Q8/0 for housing HTG:61 83 401 0070 HTG:09 30 010 5432 5.3 HTG:09 99 000 0303 HTG:09 99 000 0110 HTG:09 99 000 0110 5,17 22,92 Description Crimping tool for Han Q4/2 for Cross sections from 1,5mm² up to 6mm² Crimping tool for Han Q8/0 for Cross sections from 1,5mm² up to 6mm² Crimping tool for Han 10E for Cross sections from 1,5mm² up to 2,5mm² UPE € 307,06 382,52 382,52 Dismantle tool for male and female inserts Order number HTG:09 99 000 0305 HTG:09 99 000 0319 HTG:09 99 000 0319 HTG:09 99 000 0012 HTG:09 99 000 0381 Version 2013/01 Page 42 6,39 Crimping tool Order number 5.4 Protection cover with bracket for Han Q4/2 and Q8/0 Hood/Power T Protection cover Han 10e for Hood (with bracket) UPE € Description Dismantle tool for Han Q4/2 for Cross sections from 1,5mm² up to 6mm² Dismantle tool for Han Q8/0 for Cross sections from 1,5mm² up to 6mm² Dismantle tool for Han 10e for Cross sections from 1,5mm² up to 2,5mm² Dismantle tool for Han D/R 15 for Cross sections from 0,14mm² up to 2,5mm² Dismantle tool for Cross sections from 10mm² UPE € 9,69 17,19 17,19 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro ET 200pro Ergänzungsprodukte (Supplementary products) Technische Daten / Technical Data Seite 54 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.1 Energie T-Klemmverbinder / Energy T-terminal connector Han Power-S 1x Han Q4/2-F for wire gauge 4-6mm² Artikelnummer Querschnitt Part no. Wire gauge HTG:61 88 201 0500 2,5-4mm² HTG:61 88 201 0501 4-6mm² PIN h=55 1 L1 2 L2 3 L3 4 N 11 - 12 PE 2,5m Kabelspezifikation Kapitel 1.4--1.6 cable specification chapter 1.4--1.6 h=55 Han Power-S PIN Y 1 L1 2 Artikelnummer Querschnitt Part no. Wire gauge L2 HTG:61 88 201 0502 5x2,5mm² 3 L3 HTG:61 88 201 0503 5x4mm² 4 N HTG:61 88 201 0504 5x6mm² 11 - 12 PE Seite 55 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.2 Energie Doppel-T-Klemmverbinder Power double T-terminal connector Doppel-T-Klemmverbinder Artikelnummer Querschnitt Part no. Wire gauge HTG:61 88 202 0770 4-6mm² 2x Han Q4/2-F for wire gauge 4-6mm² PIN h=55 1 L1 2 L2 3 L3 4 N 11 - 12 PE Seite 56 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.3 Energie T-Klemmverbinder mit 24V DC/2A Netzteil / Energy T-terminal connector with 24V DC/2A Power Supply Elektrische und technische Daten /electrical and technical data Bemessungsspannung / rated voltage : Nennspannung / rated voltage : Uo/U 230/400 V Prüfspannung / test voltage : Isolationswiederstand : 4000 V ≥ 10¹º kΩ / Insulation resistance Bemessungsstrom / rated current : Energiebus / power line : 40 A Geräteabgang / device dispatch: 40 A Technische Daten Netzteil / technical data power supply : Primär /Input data : 100 V … 240 V AC (50 Hz / 60 Hz) Sekundär /output data : PIN 1 24 V DC / 2 A Wirkungsgrad / Efficiency: >86 ( 230 V AC) Rückspeisefestigkeit : L1 max. 32 V /Reverse voltage 2 L2 3 L3 4 N 11 - 12 PE Seite 57 Ausgabe 01/2013 Artikelnummer Querschnitt Zusätzliche Merkmale / Additionally features : Part no. Wire gauge Dauerkurzschlussfest / short-circuit proof HTG:61 88 201 0506 4-6mm² Leerlauffest / open-circuit proof Automatisches abschalten bei Kurzschluss / automatic switch off in the case of short-Circuit HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.4 Energie T-Klemmverbinder mit Wartungsschalter / Energy T-terminal connector with maintenance switch Elektrische und technische Daten /electrical and technical data Bemessungsspannung / rated voltage : Nennspannung / rated voltage : Uo/U Prüfspannung / test voltage : 230/400 V 4000 V Isolationswiederstand : ≥ 10¹º kΩ / Insulation resistance Bemessungsstrom / rated current : Energiebus / power line : 40 A Geräteabgang / device dispatch: 5A Technische Daten Schalter / technical data switch: Bemessungsspannung : 250V AC / 400 V AC / Rated voltage Bemessungsstrom : PIN 1 L1 2 L2 3 L3 4 N 11 - 12 PE Seite 58 Ausgabe 01/2013 Artikelnummer Querschnitt Part no. Wire gauge HTG:61 88 201 0505 4-6mm² / Rated current 16 (10) A / 10 (5) A HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.5 Dichtungen für Energie T-Klemmverbinder / Seals for Energy T-terminal connector Dichtung sealing Artikelnummer Querschnitt VPE/Satz Part no. Wire gauge Packaging Unit HTG:61 83 401 0200 10-13mm 2 HTG:61 83 401 0201 13-16mm 2 HTG:61 83 401 0202 16-19mm 2 HTG:61 83 401 0203 19-22mm 2 HTG:61 83 401 0204 Blindstopfen 1 Blind grommet 1.6 Han Q4/2 Power T/ Han Q4/2 Power T Artikelnummer Part no. HTG:61 88 203 0017 Elektrische und technische Daten /electrical and technical data Bemessungsspannung / rated voltage : Uo/U 230/400 V Bemessungsstrom / rated current : Energiebus : 40 A / power line Geräteabgang : 40 A / device dispatch Hinweise Attention - - Der Energiebus ist in 6mm² Aderquerschnitt ausgeführt. Der Geräteabgang ist in 4mm² Aderquerschnitt ausgeführt. Seite 59 Ausgabe 01/2013 The power bus is provided in 6mm² wire cross section. The Device site is provided in 4mm² wire cross section. HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.7 Selektiv Baustein Han Q4/2 / Selective module Han Q4/2 Artikelnummer Part no. HTG:61 88 201 0330 Elektrische und technische Daten /electrical and technical data Nennspannung : Uo/U 230/400 V / rated voltage Betriebsstrom : 25 A / rated current Dauerstrom : 25 A / continuous current Betriebsleistung : 7,5 kW / rated output Temperaturbereich : / temperature range Seite 60 Ausgabe 01/2013 -25°C bis + 55°C HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.8 Artikelnummer Part no. HTG:61 88 203 0016 Seite 61 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.9 Energie T-Verbinder für Powerbus max. 25mm² Power T-connector for power max. 25mm² Artikelnummer Querschnitt Part no. Wire gauge HTG:61 88 201 0181 4-6mm² PIN Energie T-Verbinder Power T-Connector h=60 Lochbild 138 1 L1 2 L2 3 L3 4 N 11 - 12 - 74 PE 151 Seite 62 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.10.1 Energiebusleitungen (Ringware) 2,5mm² Power bus cable (sold by ring ) 2,5mm² Anwendung Verwendung als Energie- oder Verbindungsleitung, 5 x 2,5mm² Artikelnummer Länge VPE Part no. Length Packaging unit HTG:61 88 600 0101 50m 1 HTG:61 88 600 0102 100m 1 auf Anfrage >100m 1 on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as energy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/ design Elektrische und technische Daten /electrical and technical data blanke Cu-Litze, feindrähtig /stranded bare conductor made of Cu -Litzenaufbau nach VDE 0295, Klasse 5 bzw. IEC 60228 cl.5 Nennspannung / rated voltage : Uo/U 300/500V /strand structure according to VDE 0295, Prüfspannung / test voltage : mind. 2000V class 5 + IEC 60228 class 5 + Isolationswiderstand / leakage resistance : >20MOhm x km -Adern spezial PVC Biegeradius / bending radius : Kabeldurchmesser /core insulation: special PVC - schwarze Adern mit fortl, weißem Ziffernaufdruck / black cores with white printed consecutive number coding -Schutzleiter grüngelb /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 63 Ausgabe 01/2013 ca. 15x approx. 7,5x cable diam Temperaturbereich / temperature range : bewegt - 5°C bis +70°C /moved unbewegt -30°C bis +70°C /unmoved Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 / fire performence according to IEC 60332-1 to DIN VDE 0472 part 804 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.10.2 Energiebusleitungen (Ringware) 4mm² Power bus cable (sold by ring) 4mm² 5 x 4mm² Anwendung Verwendung als Energie- oder Verbindungsleitung, Artikelnummer Länge VPE Part no. Length Packaging unit HTG:61 88 600 0107 50m 1 HTG:61 88 600 0108 100m 1 auf Anfrage >100m 1 on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as energy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/ design Elektrische und technische Daten /electrical and technical data blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km bzw. IEC 60228 cl.5 /strand structure according to VDE 0295, class 5 + IEC 60228 class 5 + -Adern spezial PVC /core insulation: special PVC - schwarze Adern mit fortl, weißem Ziffernaufdruck / black cores with white printed consecutive number coding -Schutzleiter grüngelb /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 64 Ausgabe 01/2013 Biegeradius / bending radius : Kabeldurchmesser ca. 15x approx. 7,5x cable diam Temperaturbereich / temperature range : bewegt - 5°C bis +70°C /moved unbewegt -30°C bis +70°C /unmoved Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 / fire performence according to IEC 60332-1 to DIN VDE 0472 part 804 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 1.10.3 Energiebusleitungen (Ringware) 6mm² Power bus cable (sold by ring ) 6mm² Anwendung 5 x 6mm² Verwendung als Energie- oder Verbindungsleitung, Artikelnummer Länge VPE Part no. Length Packaging unit HTG:61 88 600 0113 50m 1 HTG:61 88 600 0114 100m 1 auf Anfrage >100m 1 on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km bzw. IEC 60228 cl.5 /strand structure according to VDE 0295, class 5 + IEC 60228 class 5 + -Adern spezial PVC /core insulation: special PVC - schwarze Adern mit fortl, weißem Ziffernaufdruck / black cores with white printed consecutive number coding -Schutzleiter grüngelb /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 65 Ausgabe 01/2013 Biegeradius / bending radius : Kabeldurchmesser ca. 15x approx. 7,5x cable diam Temperaturbereich / temperature range : bewegt - 5°C bis +70°C /moved unbewegt -30°C bis +70°C /unmoved Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 / fire performence according to IEC 60332-1 to DIN VDE 0472 part 804 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.1 Energie Einspeiseleitung für Frequenzumrichter konfektioniert Power cables for frequency converter prefabricated Artikelnummer Länge Part no. Length HTG:61 88 202 0400 1,5m HTG:61 88 202 0401 3,0m HTG:61 88 202 0402 5,0m 4 x 2,5mm² HTG:61 88 202 0403 4 x 4,0mm² 10,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0404 1,5m HTG:61 88 202 0405 3,0m HTG:61 88 202 0406 5,0m HTG:61 88 202 0407 10,0m Artikelnummer Länge Part no. Length PIN X Y 1 L1 L1 2 L2 L2 3 L3 L3 HTG:61 88 202 0408 1,5m PE PE 4 x 6,0mm² HTG:61 88 202 0409 3,0m HTG:61 88 202 0410 5,0m HTG:61 88 202 0411 10,0m H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of Cu -Litzenaufbau nach VDE 0295, Klasse 5 Variable Längen auf Anfrage /nominal voltage Uo/U 300/500V Prüfspannung: /test voltage /stranded structure according Isolationswiderstand: >20MOhm x km to VDE 0295, class 5 + IEC 60228 class 5 + /leakage resistance HD 383 CLASS 5 Biegeradius: -Adern PVC-isoliert /core insulation: PVC -Schutzleiter grüngelb Gehäuse/housing ca. 15x Kabeldurchmesser /bending radius approx. 15x cable diam Temperaturbereich: bewegt /moved -Lagenverseilung unbewegt - 5°C bis +70°C /cores twisted in layers /unmoved Brandfortleitung /Flammwidrigkeit: Verriegelungselement: PA Überwurfmutter PG 16 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /fire performance according to IEC 60332-1 to DIN VDE 0472 part 804 Werkstoff: PC /material Dichteinsatz 9,0-13,0 rot /seal insert 9,0-13,0 red Dichteinsatz 11,0-15,5 weiß /seal insert 11,0-15,5 white /outer jacket colour black 4G 2,5; 4,0; 6,0 Werkstoff: -Ölbeständig / oil-resistant /material Seite 66 Ausgabe 01/2013 PC /material /lock nut -30°C bis +70°C -Außenmantel:PVC, flammwidrig -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Werkstoff: /interlock element /temperature range /green-yellow protective conductor /outer jacket : PVC, flame retardant Variable lengths on request mind. 2000V TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.2 Energie Einspeiseleitung für Frequenzumrichter einseitig konfektioniert / Power cables for frequency converter one-sided prefabricated Artikelnummer Länge Part no. Length 4 x 2,5mm² HTG:61 88 201 0192 1,5m HTG:61 88 201 0193 3,0m HTG:61 88 201 0194 5,0m HTG:61 88 201 0195 10,0m Artikelnummer Länge Part no. Length HTG:61 88 201 0196 1,5m HTG:61 88 201 0197 3,0m HTG:61 88 201 0198 5,0m HTG:61 88 201 0199 10,0m Artikelnummer Länge Part no. Length HTG:61 88 201 0200 1,5m HTG:61 88 201 0201 3,0m HTG:61 88 201 0202 5,0m HTG:61 88 201 0203 10,0m 4 x 4,0mm² PIN X Ader core 1 L1 1 2 L2 2 3 L3 3 PE gn/ge 4 x 6,0mm² ye/gn H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: HD 383 CLASS 5 /leakage resistance /material -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: Variable Längen auf Anfrage Variable lengths on request 300/500V mind. 2000V ca. 15x Kabeldurchmesser approx. 15x cable diam - 5°C bis +70°C PC Verriegelungselement: PA /interlock element PC /material /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 67 Ausgabe 01/2013 -30°C bis +70°C Dichteinsatz 9,0-13,0 rot TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.3 Energie Einspeiseleitung für Reparaturschaltermodul (RSM) konfektioniert / Power cable for (RSM) prefabricated 4 x 2,5mm² 4 x 4,0mm² Artikelnummer Länge Part no. Length HTG:61 88 202 0412 1,5m HTG:61 88 202 0413 3,0m HTG:61 88 202 0414 5,0m HTG:61 88 202 0415 10,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0416 1,5m HTG:61 88 202 0417 3,0m HTG:61 88 202 0418 5,0m HTG:61 88 202 0419 10,0m PIN X Y 1 L1 L1 Artikelnummer Länge 2 L2 L2 Part no. Length 3 L3 L3 HTG:61 88 202 0420 1,5m PE PE HTG:61 88 202 0421 3,0m HTG:61 88 202 0422 5,0m HTG:61 88 202 0423 10,0m 4 x 6,0mm² H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: HD 383 CLASS 5 /leakage resistance /material -Adern PVC-isoliert Biegeradius: Variable Längen auf Anfrage Variable lengths on request 300/500V mind. 2000V ca. 15x Kabeldurchmesser approx. 15x cable diam PC Verriegelungselement: PA /interlock element /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt - 5°C bis +70°C PC /material -30°C bis +70°C Dichteinsatz 9,0-13,0 rot /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 68 Ausgabe 01/2013 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.4 Energie Einspeiseleitung für Reparaturschaltermodul (RSM) einseitig konfektioniert / Power cable for (RSM) one-sided prefabricated Artikelnummer Länge Part no. Length HTG:61 88 201 0310 1,5m HTG:61 88 201 0311 3,0m HTG:61 88 201 0312 5,0m HTG:61 88 201 0313 10,0m Artikelnummer Länge Part no. Length HTG:61 88 201 0184 1,5m HTG:61 88 201 0185 3,0m Ader HTG:61 88 201 0186 5,0m Core HTG:61 88 201 0187 10,0m Artikelnummer Länge Part no. Length HTG:61 88 201 0188 1,5m HTG:61 88 201 0189 3,0m HTG:61 88 201 0190 5,0m HTG:61 88 201 0191 10,0m 4 x 2,5mm² 4 x 4,0mm² PIN X 1 L1 1 2 L2 2 3 L3 3 PE gn/ge 4 x 6,0mm² ye/gn H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung: Variable Längen auf Anfrage Variable lengths on request /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: HD 383 CLASS 5 /leakage resistance /material -Adern PVC-isoliert Biegeradius: 300/500V mind. 2000V ca. 15x Kabeldurchmesser approx. 15x cable diam PC Verriegelungselement: PA /interlock element /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt - 5°C bis +70°C PC /material -30°C bis +70°C Dichteinsatz 9,0-13,0 rot /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 69 Ausgabe 01/2013 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.5.1 Energie-Einspeiseleitungen (Ringware) 2,5mm² Power bus cable (sold by ring) 2,5mm² Anwendung Verwendung als Energie- oder Verbindungsleitung, 4 x 2,5mm² Artikelnummer Länge VPE Part no. Length Packaging unit HTG:61 88 600 0115 50m 1 HTG:61 88 600 0116 100m 1 auf Anfrage >100m 1 on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/ design Elektrische und technische Daten /electrical and technical data blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km bzw. IEC 60228 cl.5 /strand structure according to VDE 0295, class 5 + IEC 60228 class 5 + -Adern spezial PVC /core insulation: special PVC - schwarze Adern mit fortl, weißem Ziffernaufdruck / black cores with white printed consecutive number coding -Schutzleiter grüngelb /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 70 Ausgabe 01/2013 Biegeradius / bending radius : Kabeldurchmesser ca. 15x approx. 7,5x cable diam Temperaturbereich / temperature range : bewegt - 5°C bis +70°C /moved unbewegt -30°C bis +70°C /unmoved Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 / fire performence according to IEC 60332-1 to DIN VDE 0472 part 804 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.5.2 Energie-Einspeiseleitungen (Ringware) 4mm² Power bus cable (sold by ring) 4mm² 4 x 4mm² Anwendung Verwendung als Energie- oder Verbindungsleitung, Artikelnummer Länge VPE Part no. Length Packaging unit HTG:61 88 600 0117 50m 1 HTG:61 88 600 0118 100m 1 auf Anfrage >100m 1 on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km bzw. IEC 60228 cl.5 /strand structure according to VDE 0295, class 5 + IEC 60228 class 5 + -Adern spezial PVC /core insulation: special PVC - schwarze Adern mit fortl, weißem Ziffernaufdruck / black cores with white printed consecutive number coding -Schutzleiter grüngelb /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 71 Ausgabe 01/2013 Biegeradius / bending radius : Kabeldurchmesser ca. 15x approx. 7,5x cable diam Temperaturbereich / temperature range : bewegt - 5°C bis +70°C /moved unbewegt -30°C bis +70°C /unmoved Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 / fire performence according to IEC 60332-1 to DIN VDE 0472 part 804 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.5.3 Energie-Einspeiseleitungen (Ringware) 6mm² Power bus cable (sold by ring ) 6mm² Anwendung 4 x 6mm² Verwendung als Energie- oder Verbindungsleitung, Artikelnummer Länge VPE Part no. Length Packaging unit HTG:61 88 600 0119 50m 1 HTG:61 88 600 0120 100m 1 auf Anfrage >100m 1 on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km bzw. IEC 60228 cl.5 /strand structure according to VDE 0295, class 5 + IEC 60228 class 5 + -Adern spezial PVC /core insulation: special PVC - schwarze Adern mit fortl, weißem Ziffernaufdruck / black cores with white printed consecutive number coding -Schutzleiter grüngelb /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 72 Ausgabe 01/2013 Biegeradius / bending radius : Kabeldurchmesser ca. 15x approx. 7,5x cable diam Temperaturbereich / temperature range : bewegt - 5°C bis +70°C /moved unbewegt -30°C bis +70°C /unmoved Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 / fire performence according to IEC 60332-1 to DIN VDE 0472 part 804 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.6 Steckersatz für Energie-Einspeiseleitung / Connector set for power cable Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black Han Q8/0-Kg-16 Kupplungsgehäuse Dichteinsatz hood cable to cable 2.6 Stift-Stecker netzseitig seal insert Male insert the network side Han Q4/2-M-c Stifteinsatz male insert 5x Han C Stiftkontakt, versilbert Crimpwerkzeug/ Crimping tool Han C male contact, silver plated HTG:09 99 000 0110 Han D Han E Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge seal insert HTG:61 83 401 0244 2,5 mm² 9 – 15,5 rot+weiß/red+white HTG:61 83 401 0249 4,0 mm² 11,5 – 15,5 weiß/white HTG:61 83 401 0246 6,0 mm² 12 – 16,5 natur/natur Han C 1,5-4mm² HTG:09 99 000 0303 Han C 4-6mm² Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black Hinweise Han Q8/0-Kg-16 Kupplungsgehäuse Dichteinsatz hood cable to cable - Zum Anschlus nur Innensechskant mit Schlüsselweite SW 2 benutzen. - Bei Nicht-Verwendung des PE-Kontakts: PE-Kontakt beidseitig in Uhrzeiugersinn mit Innensechskant SW 2 maximal andrehen seal insert Attention Han Q4/2 Axial Stifteinsatz - For termination please use only hexagonal srew driver with wrench size SW 2. - If PE contact is not used: Please srew the PE contact maximal on both sides clockwise with a hexagonal screwdriver, wrench size SW 2. male insert Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge seal insert HTG:61 83 401 0250 4 - 10 mm² 11,5 – 15,5 weiß/white Seite 73 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.6 Steckersatz für Energie-Einspeiseleitung / Connector set for power cable Han Q8/0-Tg-16 Tüllengehäuse Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black hood side-entry 2.6 Buchsen-Stecker geräteseitig Han Q4/2-F-c Buchseneinsatz Female insert the device side Dichteinsatz female insert seal insert 5x Han C Buchsentkontakt, versilbert Han C female contact, silver plated Crimpwerkzeug/ Crimping tool HTG:09 99 000 0110 Han D Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge seal insert HTG:61 83 401 0247 2,5 mm² 9 – 15,5 rot+weiß/red+white HTG:61 83 401 0248 4,0 mm² 11,5 – 15,5 weiß/white HTG:61 83 401 0245 6,0 mm² 12 – 16,5 natur/natur Han Q8/0-Tg-16 Tüllengehäuse Han E Han C 1,5-4mm² HTG:09 99 000 0303 Han C 4-6mm² Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black hood side-entry Hinweise Han Q4/2 Axial Buchseneinsatz Dichteinsatz female insert seal insert - Zum Anschlus nur Innensechskant mit Schlüsselweite SW 2 benutzen. - Bei Nicht-Verwendung des PE-Kontakts: PE-Kontakt beidseitig in Uhrzeiugersinn mit Innensechskant SW 2 maximal andrehen Attention - For termination please use only hexagonal srew driver with wrench size SW 2. - If PE contact is not used: Please srew the PE contact maximal on both sides clockwise with a hexagonal screwdriver, wrench size SW 2. Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge seal insert HTG:61 83 401 0251 4 - 10 mm² 11,5 – 15,5 weiß/white Seite 74 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.7 Energie-Weiterleitung von Reparaturschaltermodul (RSM)/ Motorstarter (MS) auf Motorstarter (MS) konfektioniert Power transfer from RSM / Motor Starter (MS) to motor starter (MS), prefabricated 4 x 2,5mm² 4 x 4,0mm² PIN X Y 1 L1 L1 2 L2 L2 3 L3 L3 PE PE 4 x 6,0mm² Artikelnummer Länge Part no. Length HTG:61 88 202 0340 1,5m HTG:61 88 202 0341 3,0m HTG:61 88 202 0342 5,0m HTG:61 88 202 0343 10,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0344 1,5m HTG:61 88 202 0345 3,0m HTG:61 88 202 0346 5,0m HTG:61 88 202 0347 10,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0348 1,5m HTG:61 88 202 0349 3,0m HTG:61 88 202 0350 5,0m HTG:61 88 202 0351 10,0m H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: HD 383 CLASS 5 /leakage resistance /material -Adern PVC-isoliert Biegeradius: Variable Längen auf Anfrage Variable lengths on request 300/500V mind. 2000V ca. 15x Kabeldurchmesser approx. 15x cable diam PC Verriegelungselement: PA /interlock element /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt - 5°C bis +70°C PC /material -30°C bis +70°C Dichteinsatz 9,0-13,0 rot /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 75 Ausgabe 01/2013 TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.8 Energie-Weiterleitung von Motorstarter (MS) auf Reparaturschaltermodul (RSM) konfektioniert Power transfers from motor starter (MS) to RSM prefabricated 4 x 2,5mm² 4 x 4,0mm² PIN X Y 1 L1 L1 2 L2 L2 3 Artikelnummer Länge Part no. Length HTG:61 88 202 0352 1,5m HTG:61 88 202 0353 3,0m HTG:61 88 202 0354 5,0m HTG:61 88 202 0355 10,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0356 1,5m HTG:61 88 202 0357 3,0m HTG:61 88 202 0358 5,0m HTG:61 88 202 0359 10,0m Artikelnummer Länge Length L3 L3 Part no. PE PE HTG:61 88 202 0360 1,5m HTG:61 88 202 0361 3,0m HTG:61 88 202 0362 5,0m HTG:61 88 202 0363 10,0m 4 x 6,0mm² H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: /material Variable Längen auf Anfrage Variable lengths on request 300/500V mind. 2000V PC HD 383 CLASS 5 /leakage resistance -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 76 Ausgabe 01/2013 ca. 15x Kabeldurchmesser approx. 15x cable diam - 5°C bis +70°C Verriegelungselement: PA /interlock element PC /material -30°C bis +70°C Dichteinsatz 9,0-13,0 rot TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 2.9 Steckerset für Energieweiterleitung / Set of connectors for power transfer Han Q8/0-Tg-16 Tüllengehäuse Dichteinsatz seal insert Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black hood side-entry Han Q4/2-M-c Stifteinsatz Stift-Stecker male insert Male insert 5x Han C Stiftkontakt, versilbert Han C male contact, silver plated Han Q8/0-Tg-16 Tüllengehäuse hood side-entry Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge seal insert HTG:61 04 401 1001 4,0mm² 9 – 13 rot/red HTG:61 04 401 1002 6,0 mm² 11,5 – 15,5 weiß/white Dichteinsatz Überwurfmutter Pg 16 Ku, sw seal insert connecting nut PG16, thermoplastic, black Han Q4/2-F-c Buchseneinsatz Buchsen-Stecker female insert Female insert 5x Han C Buchsentkontakt, versilbert Han C female contact, silver plated Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge seal insert HTG:61 04 401 1003 4,0mm² 9 – 13 rot/red HTG:61 04 401 1004 6,0 mm² 11,5 – 15,5 weiß/white Crimpwerkzeug/ Crimping tool HTG:09 99 000 0110 Han D Han E Han C 1,5-4mm² HTG:09 99 000 0303 Han C 4-6mm² Seite 77 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.1.1 Motorleitung für Motoren in Sternschaltung, ohne Bremse, ohne Schutzbeschaltung, konfektioniert / Motor cable for motors in star connection, without brake, without EMC protective circuit, prefabricated Ansicht X View X Y PIN X Y 1 L1 L1 2 - L2 3 L3 L3 4 - - 5 - - 6 - Ansicht Y View Y 4 x 1,5mm² Brücke bridge 7 L2 8 - 9 - - 10 - - PE PE 4 x 2,5mm² Artikelnummer Länge Part no. Length HTG:61 88 202 0424 1,5m HTG:61 88 202 0425 3,0m HTG:61 88 202 0426 5,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0427 1,5m HTG:61 88 202 0428 3,0m HTG:61 88 202 0429 5,0m Variable Längen auf Anfrage Variable lengths on request H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: /material 300/500V mind. 2000V PC HD 383 CLASS 5 /leakage resistance -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: ca. 15x Kabeldurchmesser approx. 15x cable diam - 5°C bis +70°C Verriegelungselement: PA /interlock element PC /material /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 78 Ausgabe 01/2013 -30°C bis +70°C Dichteinsatz 9,0-13,0 rot TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.1.2 Motorleitung für Motoren in Sternschaltung, ohne Bremse, mit Schutzbeschaltung, konfektioniert / Motor cable for motors in star connection, without brake, with EMC protective circuit, prefabricated Ansicht Y View Y Ansicht X View X Y PIN X Y 1 L1 L1 2 - L2 3 L3 L3 4 - - 5 - - 6 - 7 L2 8 - 9 - - 10 - - PE PE 4 x 1,5mm² Schutzbeschaltung suppressor Brücke bridge 4 x 2,5mm² Artikelnummer Länge Part no. Length HTG:61 88 202 0600 1,5m HTG:61 88 202 0601 3,0m HTG:61 88 202 0602 5,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0603 1,5m HTG:61 88 202 0604 3,0m HTG:61 88 202 0605 5,0m Variable Längen auf Anfrage Variable lengths on request H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: /material 300/500V mind. 2000V PC HD 383 CLASS 5 /leakage resistance -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: ca. 15x Kabeldurchmesser approx. 15x cable diam - 5°C bis +70°C Verriegelungselement: PA /interlock element PC /material /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 79 Ausgabe 01/2013 -30°C bis +70°C Dichteinsatz 9,0-13,0 rot TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.2.1 Motorleitung für Motoren in Sternschaltung, ohne Bremse, einseitig konfektioniert / Motor cable for motors in star connection, without Ansicht X brake, one-sided prefabricated View X Artikelnummer Länge Part no. Length HTG:61 88 201 0211 1,5m HTG:61 88 201 0212 3,0m HTG:61 88 201 0213 5,0m - Artikelnummer Länge Part no. Length HTG:61 88 201 0214 1,5m HTG:61 88 201 0215 3,0m HTG:61 88 201 0216 5,0m PIN X Ader Core 1 L1 1 2 - - 3 L3 3 4 - 5 - - 6 - - 7 L2 2 4 x 1,5mm² 4 x 2,5mm² 8 PE gn/ge ye/gn Variable Längen auf Anfrage Variable lengths on request H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: /material 300/500V mind. 2000V PC HD 383 CLASS 5 /leakage resistance -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 80 Ausgabe 01/2013 ca. 15x Kabeldurchmesser approx. 15x cable diam - 5°C bis +70°C Verriegelungselement: PA /interlock element PC /material -30°C bis +70°C Dichteinsatz 9,0-13,0 rot TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.2.2 Motorleitung für Motoren in Sternschaltung, mit Bremse, einseitig konfektioniert / Motor cable for motors in star connection, with brake, one-sided prefabricated Ansicht X View X Artikelnummer Länge Part no. Length HTG:61 88 201 0218 1,5m HTG:61 88 201 0219 3,0m HTG:61 88 201 0220 5,0m Artikelnummer Länge Part no. Length 5 HTG:61 88 201 0221 1,5m 2 HTG:61 88 201 0222 3,0m HTG:61 88 201 0223 5,0m PIN X Ader Core 1 L1 1 2 - - 3 L3 3 4 Bremse 4 5 - - 6 Bremse 7 L2 6 x 1,5mm² 6 x 2,5mm² 8 PE gn/ge ye/gn Variable Längen auf Anfrage Variable lengths on request H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: /material 300/500V mind. 2000V PC HD 383 CLASS 5 /leakage resistance -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 81 Ausgabe 01/2013 ca. 15x Kabeldurchmesser approx. 15x cable diam - 5°C bis +70°C Verriegelungselement: PA /interlock element PC /material -30°C bis +70°C Dichteinsatz 9,0-13,0 rot TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.3.1 Motorleitung für Motoren in Sternschaltung, mit Bremse, ohne Schutzbeschaltung, konfektioniert / Motor cable for motor in star connection with brake, without EMC protective circuit, prefabricated Ansicht X View X Y PIN X Y 1 L1 L1 2 - L2 3 L3 L3 4 Bremse Bremse 5 - Bremse 6 Bremse Ansicht Y View Y 6 x 1,5mm² Brücke bridge 7 L2 8 - 9 - - 10 - - PE PE 6 x 2,5mm² Artikelnummer Länge Part no. Length HTG:61 88 202 0607 1,5m HTG:61 88 202 0608 3,0m HTG:61 88 202 0609 5,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0610 1,5m HTG:61 88 202 0611 3,0m HTG:61 88 202 0612 5,0m Variable Längen auf Anfrage Variable lengths on request H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: /material 300/500V mind. 2000V PC HD 383 CLASS 5 /leakage resistance -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 82 Ausgabe 01/2013 ca. 15x Kabeldurchmesser approx. 15x cable diam - 5°C bis +70°C Verriegelungselement: PA /interlock element PC /material -30°C bis +70°C Dichteinsatz 9,0-13,0 rot TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.3.2 Motorleitung für Motoren in Sternschaltung, mit Bremse, mit Schutzbeschaltung, konfektioniert / Motor cable for motor in star Ansicht Y connection with brake, with EMC protective circuit, prefabricated View Y Ansicht X View X Y PIN X Y 1 L1 L1 2 - L2 3 L3 L3 4 Bremse Bremse 5 - 6 Bremse 7 L2 8 - 9 - - 10 - - PE PE Bremse 6 x 1,5mm² Schutzbeschaltung suppressor Brücke bridge 6 x 2,5mm² Artikelnummer Länge Part no. Length HTG:61 88 202 0430 1,5m HTG:61 88 202 0431 3,0m HTG:61 88 202 0432 5,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0433 1,5m HTG:61 88 202 0434 3,0m HTG:61 88 202 0435 5,0m Variable Längen auf Anfrage Variable lengths on request H05VV5-F Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung: /stranded bare conductor made of /nominal voltage Cu Uo/U -Litzenaufbau nach VDE 0295, Klasse 5 Prüfspannung: /stranded structure according /test voltage Gehäuse/housing to VDE 0295, class 5 + IEC 60228 class 5 + Isolationswiderstand: >20MOhm x km Werkstoff: HD 383 CLASS 5 /leakage resistance /material -Adern PVC-isoliert Biegeradius: /core insulation: PVC /bending radius -Schutzleiter grüngelb Temperaturbereich: Überwurfmutter PG 16 /green-yellow protective conductor /temperature range /lock nut -Lagenverseilung bewegt Werkstoff: /cores twisted in layers /moved -Außenmantel:PVC, flammwidrig unbewegt /outer jacket : PVC, flame retardant /unmoved /seal insert 9,0-13,0 red -Mantelfarbe schwarz 4G 2,5; 4,0; 6,0 Brandfortleitung /Flammwidrigkeit: Dichteinsatz 11,0-15,5 weiß /outer jacket colour black 4G 2,5; 4,0; 6,0 gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 /seal insert 11,0-15,5 white -Ölbeständig / oil-resistant /fire performance according to IEC 60332-1 Werkstoff: to DIN VDE 0472 part 804 /material Seite 83 Ausgabe 01/2013 300/500V mind. 2000V ca. 15x Kabeldurchmesser approx. 15x cable diam - 5°C bis +70°C PC Verriegelungselement: PA /interlock element PC /material -30°C bis +70°C Dichteinsatz 9,0-13,0 rot TPE HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.4 Motorleitung (Meterware) 1,5mm² Motor cable (sold by meter) 1,5mm² Anwendung 4 x 1,5mm² Verwendung als Energie- oder Verbindungsleitung, Artikelnummer Länge Part no. Length HTG:61 88 600 0121 50m HTG:61 88 600 0122 100m auf Anfrage >100m on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km bzw. IEC 60228 cl.5 /strand structure according to VDE 0295, class 5 + IEC 60228 class 5 + -Adern spezial PVC /core insulation: special PVC - schwarze Adern mit fortl, weißem Ziffernaufdruck / black cores with white printed consecutive number coding -Schutzleiter grüngelb /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 84 Ausgabe 01/2013 Biegeradius / bending radius : Kabeldurchmesser ca. 15x approx. 7,5x cable diam Temperaturbereich / temperature range : bewegt - 5°C bis +70°C /moved unbewegt -30°C bis +70°C /unmoved Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 / fire performence according to IEC 60332-1 to DIN VDE 0472 part 804 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.5 Motorleitung (Meterware) 2,5mm² Motor cable (sold by meter) 2,5mm² Anwendung 4 x 2,5mm² Verwendung als Energie- oder Verbindungsleitung, Artikelnummer Länge Part no. Length HTG:61 88 600 0125 50m HTG:61 88 600 0126 100m auf Anfrage >100m on request als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und Applications Fertigungsstraßen. Used as ernergy or connecting cable, as measuring, checking and Geeignet für feste Verlegung oder flexible Anwen- control cable in maschine tool manufacturing and on assembly lines dungen bei freier Bewegung ohne zwangsweise and production lines. Suitable for fixed intallation with unrestricted Bewegungsführung und ohne Zugbeanspruchung, mobility without forced movement control and without exosure to tensile in trockenen und feuchten Räumen, im Freien fest load. Installation in dry and moist rooms. If you use it outside look at verlegt unter Beachtung des Temperaturbereichs. the temperature range. Keine Anwendung im Wasser oder in der Erde. Could not be used in water or in the ground. Aufbau/ design Elektrische und technische Daten /electrical and technical data -blanke Cu-Litze, feindrähtig Nennspannung / rated voltage : Uo/U 300/500V /stranded bare conductor made of Cu Prüfspannung / test voltage : mind. 2000V -Litzenaufbau nach VDE 0295, Klasse 5 Isolationswiderstand / leakage resistance : >20MOhm x km bzw. IEC 60228 cl.5 /strand structure according to VDE 0295, class 5 + IEC 60228 class 5 + -Adern spezial PVC /core insulation: special PVC - schwarze Adern mit fortl, weißem Ziffernaufdruck / black cores with white printed consecutive number coding -Schutzleiter grüngelb /green-yellow protective conductor -Lagenverseilung /cores twisted in layers -Außenmantel: spezial PVC, flammwidrig und UV-beständig /outer sheath: special PVC, flame retardant and UV-resistance -Mantelfarbe schwarz RAL 9005 /core-colour black RAL 9005 Seite 85 Ausgabe 01/2013 Biegeradius / bending radius : Kabeldurchmesser ca. 15x approx. 7,5x cable diam Temperaturbereich / temperature range : bewegt - 5°C bis +70°C /moved unbewegt -30°C bis +70°C /unmoved Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B und IEC 332-1 / fire performence according to IEC 60332-1 to DIN VDE 0472 part 804 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.6 Steckersätze für Motor-Anschlussleitung auf Motorstarterseite,(MS) Set of connectors for motor connection cable on the side of the motor starter (MS) Überwurfmutter Pg 16 Ku, sw Dichteinsatz Han Q8/0-Tg-16 Tüllengehäuse connecting nut PG16, thermoplastic, black seal insert hood side-entry Stift-Stecker Han Q4/2-M-c Stifteinsatz Male insert male insert 6x Han E-Stiftkontakt, versilbert Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge seal insert HTG:61 83 401 0065 1,5mm² 9 – 13 rot/red HTG:61 83 401 0066 2,5 mm² 11,5 – 15,5 weiß/white Han E male contact, silver plated 3.7.1 Steckersätze für Motor-Anschlussleitung auf Motorstarterseite ohne Schutzbeschaltung / Set of connectors for motor connection cable on the of the motor without EMC protective circuit Verschraubung Dichteinsatz cable gland seal insert Han 10B-gg-R-M20 Tüllengehäuse hood top-entry Han 10E-F-c Buchseneinsatz Buchsen-Stecker female insert Female insert Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge seal insert HTG:61 83 401 0047 1,5mm² 9 – 13 rot/red HTG:61 83 401 0067 2,5 mm² 11,5 – 15,5 weiß/white 7x Han E-Buchsenkontakt, versilbert Han E female contact, silver plated Seite 86 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 3.7.2 Steckersätze für Motor-Anschlussleitung auf Motorstarterseite, mit Schutzbeschaltung / Set of connectors for motor connection cable on the side of the motor , with EMC protective circuit Dichteinsatz seal insert Verschraubung cable gland Han 10B-gg-R-M20 Tüllengehäuse hood top-entry RC-Baustein RC-Module Han 10E-F-c Buchseneinsatz female insert Sternbrücke cable gland Buchsen-Stecker Female insert 7x Han E-Buchsenkontakt, versilbert Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge seal insert HTG:61 83 401 0068 1,5mm² 9 – 13 rot/red HTG:61 83 401 0069 2,5 mm² 11,5 – 15,5 weiß/white Han E female contact, silver plated Seite 87 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.1 Motorleitung (geschirmt) für Motoren in Sternschaltung mit Bremse und Temperaturgeber / Motor cable (screened) for motors with star connection with brakes and termic device Länge Artikelnummer Länge Part no. Length HTG:61 88 202 0499 1,5m 4 x 1,5mm² HTG:61 88 202 0514 3,0m + 2x(2x 0,75mm²) HTG:61 88 202 0515 5,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0500 1,5m 4 x 2,5mm² HTG:61 88 202 0520 3,0m + 2x(2x 0,75mm²) HTG:61 88 202 0521 5,0m Y dimension Ansicht X X View X PIN X Y 1 U U 2 - V 3 W W 4 Bremse Bremse 5 Temp. Bremse 6 Bremse 7 V 8 Temp. 9 - View Y Variable lengths on request Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Temp. Leistungsadern: PE Bremse-brake Multiflex Servo Aufbau blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Gehäuse/housing Werkstoff: ZN bzw. AL -Druckg. /material Verschraubung : M 25 / screw Überwurfmutter : M25 /lock nut MS /material Dichteinsatz / seal insert Werkstoff: TPE / Neopren /material Seite 88 Ausgabe 01/2013 Uo/U 600/1000V Uo/U 300V /power cores Temp. PE Werkstoff: Variable Längen auf Anfrage Brücke bridge - 10 Ansicht Y Signaladern : /control cores Prüfspannung / test voltage: Leistungsadern : 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Multiflex Servo design Zugfestigkeit : max. 50 N/mm² Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Temperaturbereich / temperature range : / Admissible tensile load bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.1.3 Motorleitung (geschirmt) für Motoren in Sternschaltung mit Bremse und Temperaturgeber/ Motor cable (screened) for motors with star connection with brakes and termic device Länge + (2x 1,0mm² + 2x1,5mm²) dimension Ansicht X View X PIN X Y 1 U U 2 - V 3 W W 4 Bremse Bremse 5 Temp. Bremse 6 Bremse 7 V 8 Temp. 9 - 4 x 4,0mm² Artikelnummer Länge Part no. Length HTG:61 88 202 0522 1,5m HTG:61 88 202 0523 3,0m HTG:61 88 202 0524 5,0m Variable Längen auf Anfrage Variable lengths on request Ansicht Y View Y Brücke bridge Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Temp. Leistungsadern: - Temp. /power cores PE PE /control cores 10 Bremse-brake Signaladern : Multiflex Servo Aufbau blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Werkstoff: ZN bzw. AL -Druckg. /material Verschraubung : M 25 / screw MS /material Dichteinsatz / seal insert Werkstoff: 600/1000V Uo/U 300V Prüfspannung / test voltage: Leistungsadern : 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Gehäuse/housing Werkstoff: Uo/U TPE / Neopren /material Seite 89 Ausgabe 01/2013 Multiflex Servo design Zugfestigkeit : max. 50 N/mm² Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Temperaturbereich / temperature range : / Admissible tensile load bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.1.4 Adapterleitung - 4mm² Geräteanschluss auf 6mm² für UL- Norm Motor cable (screened) used for UL applications Länge dimension 4 x 4,0mm² + (2x 1,0mm² + 2x1,5mm²) Artikelnummer Länge Part no. Length HTG:61 88 202 0497 0,3m Ansicht X View X PIN X X Y PIN Y 1 U U 1 2 - V 2 3 W W 3 4 Bremse Bremse 1 5 Temp. Bremse 2 6 Bremse 7 V 8 Temp. 9 - Temp. 5 10 - Temp. 6 PE PE Variable Längen auf Anfrage Variable lengths on request Ansicht Y View Y Elektrische und technische Daten /electrical and technical data /material Verschraubung : M 25 / screw Werkstoff: MS /material Dichteinsatz / seal insert Werkstoff: TPE / Neopren /material Seite 90 Ausgabe 01/2013 Uo/U 600/1000V Uo/U 300V /power cores /control cores blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Gehäuse/housing Werkstoff: ZN bzw. AL -Druckg. Leistungsadern: Signaladern : Multiflex Servo Aufbau Bremse-brake Nennspannung /rated voltage : Multiflex Servo design Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Prüfspannung / test voltage: Leistungsadern : 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² / Admissible tensile load Temperaturbereich / temperature range : bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.1.5 Steckerset für Adapterleitung Set of connectors Verschraubung M32/EMV Srew M25 Han 10EMV/B-kg-M32 hood Han C Siftkontakt, gedreht 40A, versilbert Han C male contact, twisted 40A, silver plated Han-Modular Gelenkrahmen Han-Modular hinged frame Fixierungen für Gelenkrahmen lockings for hinged frames Han E Kontakt gedreht 16A Han E contact twisted 16A Han E-Modul, Stifteinsatz Han E-module, male insert Han-Modular Blindmodul Stift-Stecker Han dummy module male insert Han 4Mod-F-C 40A,Stifteinsatz male insert Artikelnummer Querschnitt Part no. Wire gauge HTG:61 83 401 0130 4x6 + (2x1,0mm² + 2x1,5mm²) Die Dichteinsätze sind passend für geschirmte Motorleitungen Kapitel 3.4 - 3.7. Sealing fit`s to screened motor cable item 3.4 - 3.7. Seite 91 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.2 Motorleitung (geschirmt) für Motoren in Dreieckschaltung mit Bremse und Temperaturgeber / Motor cable (screened) for motors with delta connection with brakes and termic device Artikelnummer Länge Part no. Length HTG:61 88 202 0525 1,5m 4 x 1,5mm² HTG:61 88 202 0526 3,0m + 2x(2x 0,75mm²) HTG:61 88 202 0527 5,0m Artikelnummer Länge Part no. Length HTG:61 88 202 0528 1,5m HTG:61 88 202 0529 3,0m HTG:61 88 202 0530 5,0m Länge Y dimension Ansicht X X View X PIN X Y 1 U U 2 - V 4 x 2,5mm² + 2x(2x 0,75mm²) 3 W W 4 Bremse Bremse 5 Temp. 6 Bremse 7 V 8 Temp. 9 - Bremse Ansicht Y View Y Variable lengths on request Nennspannung /rated voltage : Temp. Temp. PE PE Bremse-brake Leistungsadern: Werkstoff: ZN bzw. AL -Druckg. /material Verschraubung : M 25 / screw Überwurfmutter : M25 /lock nut MS /material Dichteinsatz / seal insert Werkstoff: TPE / Neopren /material Seite 92 Ausgabe 01/2013 Uo/U 600/1000V Uo/U 300V /power cores Signaladern : Multiflex Servo Aufbau /control cores blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Leistungsadern : Gehäuse/housing Werkstoff: Variable Längen auf Anfrage Elektrische und technische Daten /electrical and technical data - 10 Brücke bridge Prüfspannung / test voltage: 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Multiflex Servo design Zugfestigkeit : max. 50 N/mm² Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Temperaturbereich / temperature range : / Admissible tensile load bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.2.3 Motorleitung (geschirmt) für Motoren in Dreieckschaltung mit Bremse und Temperaturgeber / Motor cable (screened) for motors with delta connection with brakes and termic device Länge + (2x 1,0mm² + 2x1,5mm²) dimension Ansicht X View X PIN X Y 1 U U 2 - V 3 W W 4 Bremse Bremse 5 Temp. Bremse 6 Bremse 7 V 8 Temp. 9 - Temp. 10 - Temp. PE PE 4 x 4,0mm² Artikelnummer Länge Part no. Length HTG:61 88 202 0531 1,5m HTG:61 88 202 0532 3,0m HTG:61 88 202 0533 5,0m Variable Längen auf Anfrage Variable lengths on request Ansicht Y View Y Brücke bridge Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Signaladern : Multiflex Servo Aufbau blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Bremse-brake Werkstoff: ZN bzw. AL -Druckg. Uo/U 300V /control cores Prüfspannung / test voltage: Leistungsadern : 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Multiflex Servo design Zugfestigkeit : max. 50 N/mm² Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Temperaturbereich / temperature range : /material Verschraubung : M 25 / screw MS /material Dichteinsatz / seal insert Werkstoff: 600/1000V Beschleunigung / acceleration : max. 7m/s² Gehäuse/housing Werkstoff: Uo/U /power cores TPE / Neopren /material Seite 93 Ausgabe 01/2013 / Admissible tensile load bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.3.1.3 Motorleitung (geschirmt) für Motoren mit Bremse und Temperaturgeber, einseitig konfektioniert Motor cable (screened) for motors with brakes and termic device, assembled one side Länge dimension Ansicht X PIN X Ader View X 4 x 4,0mm² + (2x 1,0mm² + 2x1,5mm²) Artikelnummer Länge Part no. Length HTG:61 88 201 0303 1,5m HTG:61 88 201 0304 3,0m HTG:61 88 201 0305 5,0m HTG:61 88 201 0306 10,0m HTG:61 88 201 0307 15,0m core 1 U 1 2 - - 3 W 3 4 Bremse 5 5 Temp. 7 6 Bremse Variable Längen auf Anfrage Variable lengths on request Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: 6 7 V 2 8 Temp. 8 PE gn/ge ye/gn Uo/U 600/1000V Uo/U 300V /power cores Signaladern : /control cores Prüfspannung / test voltage: Leistungsadern : 4000V /power cores Bremse-brake Signaladern : Multiflex Servo Aufbau 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² / Admissible tensile load Temperaturbereich / temperature range : bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Gehäuse/housing Werkstoff: ZN Druckg. /material Verschraubung : M 25 / screw Werkstoff: MS /material Dichteinsatz / seal insert Werkstoff: TPE /material Seite 94 Ausgabe 01/2013 Multiflex Servo design Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.3.2 Motorleitung (geschirmt) für Motoren, einseitig konfektioniert Motor cable (screened) for motors, assembled one side Artikelnummer Länge Part no. Length Länge HTG:61 88 201 0350 1,5m dimension HTG:61 88 201 0351 3,0m HTG:61 88 201 0352 5,0m HTG:61 88 201 0353 10,0m HTG:61 88 201 0354 15,0m Artikelnummer Länge Part no. Length HTG:61 88 201 0355 1,5m HTG:61 88 201 0355 3,0m HTG:61 88 201 0357 5,0m HTG:61 88 201 0358 10,0m HTG:61 88 201 0359 15,0m 4 x 1,5mm² Ansicht X X View X PIN X Ader core 1 U 1 2 - - 3 W 3 4 - - 5 - - 6 - - 7 V 2 8 - - PE gn/ge ye/gn 4 x 2,5mm² Variable Längen auf Anfrage Variable lengths on request Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Uo/U 600/1000V Uo/U 300V /power cores Signaladern : /control cores Multiflex Servo Aufbau Prüfspannung / test voltage: Leistungsadern : 4000V /power cores blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² / Admissible tensile load Gehäuse/housing Werkstoff: ZN Druckg. /material Überwurfmutter : M25 /lock nut Werkstoff: MS /material Dichteinsatz / seal insert Werkstoff: TPE /material Seite 95 Ausgabe 01/2013 Multiflex Servo design Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Temperaturbereich / temperature range : bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.3.2.3 Motorleitung (geschirmt) für Motoren, einseitig konfektioniert Motor cable (screened) for motors, assembled one side Länge dimension Ansicht X PIN X 4 x 4,0mm² 1 2 - - 3 W 3 4 - - 5 - - 6 - - 7 V 2 8 - - Length HTG:61 88 201 0360 1,5m HTG:61 88 201 0361 3,0m HTG:61 88 201 0362 5,0m HTG:61 88 201 0363 10,0m HTG:61 88 201 0364 15,0m Variable Längen auf Anfrage core U Länge Part no. View X Ader 1 Artikelnummer Variable lengths on request Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Uo/U 600/1000V Uo/U 300V /power cores PE gn/ge ye/gn Signaladern : /control cores Multiflex Servo Aufbau Prüfspannung / test voltage: Leistungsadern : 4000V /power cores blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² Gehäuse/housing Werkstoff: ZN Druckg. /material Verschraubung : M 25 / screw Werkstoff: MS /material Dichteinsatz / seal insert Werkstoff: TPE /material Seite 96 Ausgabe 01/2013 Multiflex Servo design Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 / Admissible tensile load Temperaturbereich / temperature range : bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.4 Motorleitung (Ringware) 4 x 1,5mm²+ 2x (2 x 0,75mm²), (geschirmt) Motor cable (sold by ring), (screened) 4 x 1,5mm²+ 2x (2 x 0,75mm²) Artikelnummer Länge VPE/Satz Part no. length Packaging Unit HTG:61 88 601 0004 10m 1 HTG:61 88 601 0005 50m 1 Anwendung Diese Leitung findet Verwendung als Anschlußleitung für die Versorgung und gleichzeitiger Steuerung von Motoren, besonders in Schleppketten und an Robotern. Die doppelte Abschirmung der Paare und die Gesamtabschirmung sichert eine hervorragende EMV-Eigenschaft. Der kerbzähe und adhäsionsfreie PUR-Außenmantel zeichnet sich durch sehr gute Ölbeständigkeit, gute Chemische- und Witterungsbeständigkeit aus und gewährleistet eine hohe Standzeit mit ca. 2 Mio. Biegewechselzyklen. Applications These cables are used as connecting cables for power supply and, at the same time, as motor control cables. Primarily used on drag chains and robots. Double screening of individual pairs and overall screening provide excellent electromagnetic compatibility. The PUR outer sheath is characterised by its high impact strength, adhesion resistance, resistance to oil, fastness to weathering and resistance to chemical influences and thus ensures a long service life of the cable with approx. 2 million bending cycles. Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Uo/U 600/1000V Uo/U 300V /power cores Signaladern : /control cores Prüfspannung / test voltage: Aufbau blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Leistungsadern : 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² Design Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Seite 97 Ausgabe 01/2013 / Admissible tensile load Temperaturbereich / temperature range : bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.4.1 Motorleitung (Ringware) 4 x 1,5mm², (geschirmt) Motor cable (sold by ring ) 4 x 1,5mm², (screened) Artikelnummer Länge VPE/Satz Part no. length Packaging Unit HTG:61 88 601 0010 10m 1 HTG:61 88 601 0011 50m 1 Anwendung Diese Leitung findet Verwendung als Anschlußleitung für die Versorgung und gleichzeitiger Steuerung von Motoren, besonders in Schleppketten und an Robotern. Die doppelte Abschirmung der Paare und die Gesamtabschirmung sichert eine hervorragende EMV-Eigenschaft. Der kerbzähe und adhäsionsfreie PUR-Außenmantel zeichnet sich durch sehr gute Ölbeständigkeit, gute Chemische- und Witterungsbeständigkeit aus und gewährleistet eine hohe Standzeit mit ca. 2 Mio. Biegewechselzyklen. Applications These cables are used as connecting cables for power supply and, at the same time, as motor control cables. Primarily used on drag chains and robots. Double screening of individual pairs and overall screening provide excellent electromagnetic compatibility. The PUR outer sheath is characterised by its high impact strength, adhesion resistance, resistance to oil, fastness to weathering and resistance to chemical influences and thus ensures a long service life of the cable with approx. 2 million bending cycles. Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Uo/U 600/1000V Uo/U 300V /power cores Signaladern : /control cores Prüfspannung / test voltage: Aufbau blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Design Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Seite 98 Ausgabe 01/2013 Leistungsadern : 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² / Admissible tensile load Temperaturbereich / temperature range : bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.5 Motorleitung (Ringware) 4 x 2,5mm² + 2 x (2 x 0,75mm²), (geschirmt) Motor cable (sold by ring), (screened) 4 x 2,5mm² + 2x (2 x 0,75mm²) Artikelnummer Länge VPE/Satz Part no. length Packaging Unit HTG:61 88 601 0006 10m 1 HTG:61 88 601 0007 50m 1 Anwendung Diese Leitung findet Verwendung als Anschlußleitung für die Versorgung und gleichzeitiger Steuerung von Motoren, besonders in Schleppketten und an Robotern. Die doppelte Abschirmung der Paare und die Gesamtabschirmung sichert eine hervorragende EMV-Eigenschaft. Der kerbzähe und adhäsionsfreie PUR-Außenmantel zeichnet sich durch sehr gute Ölbeständigkeit, gute Chemische- und Witterungsbeständigkeit aus und gewährleistet eine hohe Standzeit mit ca. 2 Mio. Biegewechselzyklen. Applications These cables are used as connecting cables for power supply and, at the same time, as motor control cables. Primarily used on drag chains and robots. Double screening of individual pairs and overall screening provide excellent electromagnetic compatibility. The PUR outer sheath is characterised by its high impact strength, adhesion resistance, resistance to oil, fastness to weathering and resistance to chemical influences and thus ensures a long service life of the cable with approx. 2 million bending cycles. Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Uo/U 600/1000V Uo/U 300V /power cores Signaladern : /control cores Prüfspannung / test voltage: Aufbau blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Design Leistungsadern : 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² / Admissible tensile load Temperaturbereich / temperature range : Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Seite 99 Ausgabe 01/2013 bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.5.1 Motorleitung (Ringware) 4 x 2,5mm², (geschirmt) Motor cable (sold by ring) 4 x 2,5mm², (screened) Artikelnummer Länge VPE/Satz Part no. length Packaging Unit HTG:61 88 601 0012 10m 1 HTG:61 88 601 0013 50m 1 Anwendung Diese Leitung findet Verwendung als Anschlußleitung für die Versorgung und gleichzeitiger Steuerung von Motoren, besonders in Schleppketten und an Robotern. Die doppelte Abschirmung der Paare und die Gesamtabschirmung sichert eine hervorragende EMV-Eigenschaft. Der kerbzähe und adhäsionsfreie PUR-Außenmantel zeichnet sich durch sehr gute Ölbeständigkeit, gute Chemische- und Witterungsbeständigkeit aus und gewährleistet eine hohe Standzeit mit ca. 2 Mio. Biegewechselzyklen. Applications These cables are used as connecting cables for power supply and, at the same time, as motor control cables. Primarily used on drag chains and robots. Double screening of individual pairs and overall screening provide excellent electromagnetic compatibility. The PUR outer sheath is characterised by its high impact strength, adhesion resistance, resistance to oil, fastness to weathering and resistance to chemical influences and thus ensures a long service life of the cable with approx. 2 million bending cycles. Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Uo/U 600/1000V Uo/U 300V /power cores Signaladern : /control cores Prüfspannung / test voltage: Aufbau blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Leistungsadern : 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² Design Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Seite 100 Ausgabe 01/2013 / Admissible tensile load Temperaturbereich / temperature range : bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.6 Motorleitung (Ringware) 4 x 4mm² + (2 x 1mm²) + (2 x 1,5mm²), (geschirmt) Motor cable (sold by ring), (screened) 4 x 4mm² + (2 x 1mm²) + (2 x 1,5mm²) Artikelnummer Länge VPE/Satz Part no. length Packaging Unit HTG:61 88 601 0008 10m 1 HTG:61 88 601 0009 50m 1 Anwendung Diese Leitung findet Verwendung als Anschlußleitung für die Versorgung und gleichzeitiger Steuerung von Motoren, besonders in Schleppketten und an Robotern. Die doppelte Abschirmung der Paare und die Gesamtabschirmung sichert eine hervorragende EMV-Eigenschaft. Der kerbzähe und adhäsionsfreie PUR-Außenmantel zeichnet sich durch sehr gute Ölbeständigkeit, gute Chemische- und Witterungsbeständigkeit aus und gewährleistet eine hohe Standzeit mit ca. 2 Mio. Biegewechselzyklen. Applications These cables are used as connecting cables for power supply and, at the same time, as motor control cables. Primarily used on drag chains and robots. Double screening of individual pairs and overall screening provide excellent electromagnetic compatibility. The PUR outer sheath is characterised by its high impact strength, adhesion resistance, resistance to oil, fastness to weathering and resistance to chemical influences and thus ensures a long service life of the cable with approx. 2 million bending cycles. Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Signaladern : blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 600/1000V Uo/U 300V /control cores Prüfspannung / test voltage: Leistungsadern : Aufbau Uo/U /power cores 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² / Admissible tensile load Design Temperaturbereich / temperature range : Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 bewegt / moved : -30°C bis + 80°C Seite 101 Ausgabe 01/2013 unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.6.1 Motorleitung (Ringware) 4 x 4mm², (geschirmt) Motor cable (sold by ring) 4 x 4mm², (screened) Artikelnummer Länge VPE/Satz Part no. length Packaging Unit HTG:61 88 601 0014 10m 1 HTG:61 88 601 0015 50m 1 Anwendung Diese Leitung findet Verwendung als Anschlußleitung für die Versorgung und gleichzeitiger Steuerung von Motoren, besonders in Schleppketten und an Robotern. Die doppelte Abschirmung der Paare und die Gesamtabschirmung sichert eine hervorragende EMV-Eigenschaft. Der kerbzähe und adhäsionsfreie PUR-Außenmantel zeichnet sich durch sehr gute Ölbeständigkeit, gute Chemische- und Witterungsbeständigkeit aus und gewährleistet eine hohe Standzeit mit ca. 2 Mio. Biegewechselzyklen Applications These cables are used as connecting cables for power supply and, at the same time, as motor control cables. Primarily used on drag chains and robots. Double screening of individual pairs and overall screening provide excellent electromagnetic compatibility. The PUR outer sheath is characterised by its high impact strength, adhesion resistance, resistance to oil, fastness to weathering and resistance to chemical influences and thus ensures a long service life of the cable with approx. 2 million bending cycles. Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Uo/U 600/1000V Uo/U 300V /power cores Signaladern : /control cores Prüfspannung / test voltage: Leistungsadern : Aufbau blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 Design 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² / Admissible tensile load Temperaturbereich / temperature range : Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Seite 102 Ausgabe 01/2013 bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.7 Motorleitung (Ringware) 4 x 6mm² + 2x(2 x 1,0mm²) UL-Norm-Adapterleitung / Motor cable (screened) with UL approval, 4 x 6mm² + 2x(2 x1,0mm²), sold by ring Artikelnummer Länge VPE/Satz Part no. length Packaging Unit HTG:61 88 601 0016 10m 1 HTG:61 88 601 0017 50m 1 Anwendung Diese Leitung findet Verwendung als Anschlußleitung für die Versorgung und gleichzeitiger Steuerung von Motoren, besonders in Schleppketten und an Robotern. Die doppelte Abschirmung der Paare und die Gesamtabschirmung sichert eine hervorragende EMV-Eigenschaft. Der kerbzähe und adhäsionsfreie PUR-Außenmantel zeichnet sich durch sehr gute Ölbeständigkeit, gute Chemische- und Witterungsbeständigkeit aus und gewährleistet eine hohe Standzeit mit ca. 2 Mio. Biegewechselzyklen. Applications These cables are used as connecting cables for power supply and, at the same time, as motor control cables. Primarily used on drag chains and robots. Double screening of individual pairs and overall screening provide excellent electromagnetic compatibility. The PUR outer sheath is characterised by its high impact strength, adhesion resistance, resistance to oil, fastness to weathering and resistance to chemical influences and thus ensures a long service life of the cable with approx. 2 million bending cycles. Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : Leistungsadern: Uo/U 600/1000V Uo/U 300V /power cores Signaladern : /control cores Prüfspannung / test voltage: Leistungsadern : Aufbau blanke Cu-Litze feinstdrähtig Litzenaufbau nach VDE 0295 Klasse 6 Aderisolation: TPE Aderkennzeichnung: -Leistungsadern: schwarz mit Ziffernaufdruck 1-3 -Schutzleiter grüngelb -Signaladern: schwarz, mit Ziffernaufdruck 5-6 und 7-8, -2 Adern paarig verseilt mit einer kunststoffkaschierten Metallfolie als statischem Schirm und Cu-Geflechtschirm, verzinnt Vlies Cu-Geflechtschirm, verzinnt Außenmantel: Spezial-PUR, gleitfähig Mantelfarbe orange 2003 4000V /power cores Signaladern : 2000V /control cores Isolationswiederstand / Leistungsadern : 20Mxkm /isolation resistance / power cores Biegeradius / bending radius : ca. 10x KabelGeschwindigkeit / speed : max. 180 m/min Beschleunigung / acceleration : max. 7m/s² Zugfestigkeit : max. 50 N/mm² / Admissible tensile load Design Stranded bare conductor made of Cu extra-fine wire Strand structure according to VDE 0295, class 6 TPE-insulated cores Core marking: -Power cores: black with printed number coding 1-3 -Protective conductor: green-yellow -Control cores: black, with printed number coding 5-6 and 7-8 -2 cores twisted in pairs with a static screen made of plastics laminated metal foil and a copper braided screen, tinned Fabric Tinned copper braided screening Outer sheath:special PUR, with sliding ability Sheath colour: orange, RAL 2003 Seite 103 Ausgabe 01/2013 Temperaturbereich / temperature range : bewegt / moved : -30°C bis + 80°C unbewegt / unmoved : -50°C bis +90°C Ölbeständigkeit / oil resistance : VDE 0472 Teil / part 803 A/B Brandfortleitung / Flammwidrigkeit : /fire propagation / flame retardation VDE 0472 Teil A, IEC 332.2 VDE 0472 part 804, test method A, IEC 332-2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.8 Steckersätze (geschirmt) für Motor-Anschlussleitung auf Umrichterseite Set of connectors (screened) for motor cable at frequency inverter side Han Q8/0-tg-vern. Tüllensgehäuse hood cable to cable Dichteinsatz seal insert Überwurfmutter M25/EMV connecting nut M25/EMV 4x Han E Kontakt gedreht 16A 4x Han E contact twiated 16A 4x Han E Kontakt gedreht 16A 4x Han E contact twiated 16A Stift-Stecker Han Q8/0-M Stifteinsatz Male insert male insert Artikelnummer Part no. Querschnitt Wire gauge HTG:61 83 401 0131 4x1,5mm² + 2x (2x0,75mm²) HTG:61 83 401 0132 4x2,5mm² + 2x (2x0,75mm²) HTG:61 83 401 0133 4x4,0mm² 2x1,0mm² + 2x1,5mm² HTG:61 83 401 0253 0,5-2,5mm² Die Dichteinsätze sind passend für geschirmte Motorleitungen Kapitel 3.4 - 3.7. Sealing fit`s to screened motor cable item 3.4 - 3.7. Seite 104 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.9 Steckersätze (geschirmt) für Motor-Anschlussleitung auf Motorseite Set of connectors (screened) for motor cable at motor side Verschraubung M25/EMV srew M25 Han 10EMV/Bgg-M25 Gehäuse hood 4x Han E Kontakt gedreht 16A 4x Han E contact twiated 16A Sternbrücke cable gland Han 10E-F-c Buchseneinsatz female insert 3x Han E Kontakt gedreht 16A 3x Han E contact twiated 16A Buchsen-Stecker Female insert Artikelnummer Querschnitt Part no. Wire gauge HTG:61 83 401 0120 3x1,5mm² + 4x0,75mm² HTG:61 83 401 0121 3x2,5mm² + 2x0,75mm² HTG:61 83 401 0122 3x4,0mm² + 2x1,0mm² + 2x1,5mm² Die Dichteinsätze sind passend für geschirmte Motorleitungen Kapitel 3.4 - 3.7. Sealing fit`s to screened motor cable item 3.4 - 3.7. Seite 105 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 4.9 Steckersätze (geschirmt) für Motor-Anschlussleitung auf Motorseite Set of connectors (screened) for motor cable at motor side HTG:61 04 401 0125 Verschraubung M25/EMV srew M25 Verschraubung M25/EMV srew M25 Han 10EMV/Bgg-M25 Gehäuse hood Han 10EMV/Bgg-M25 Gehäuse 4x Han E Kontakt gedreht 16A 4x Han E contact twiated 16A hood 3x Han E Kontakt gedreht 16A 3x Han E contact twiated 16A Dreiecksbrücke delta connection Dreiecksbrücke delta connection Han 10ESS-F Buchseneinsatz Han 10E-F-c Buchseneinsatz female insert female insert Buchsen-Stecker Female insert Artikelnummer Part no. Querschnitt Wire gauge HTG:61 83 401 0123 3x1,5mm² + 3x3mm² + 4x0,75mm² HTG:61 88 401 0124 3x2,5mm² + 3x4mm² + 4x0,75mm² HTG:61 83 401 0125 3x4,0mm² + 3x2,5mm² + 4x1,0mm² Die Dichteinsätze sind passend für geschirmte Motorleitungen Kapitel 3.4 - 3.7. Sealing fit`s to screened motor cable item 3.4 - 3.7. Seite 106 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 5.1 Steckersätze für Energiebus Anschluss Schaltschrank / Unterverteiler / Set of connectors for power bus switching cabinet/subdistributor Überwurfmutter Pg 16 Ku, sw Han Q8/0-kg-16 Kupplungsgehäuse Dichteinsatz hoods cable to cable seal insert connecting nut PG16, thermoplastic, black Buchsen-Stecker Female insert Schaltschrank Innenseite Artikelnummer Querschnitt inside control cabinet Part no. Wire gauge HTG:61 88 201 0051 6mm² Schaltschrank Außenseite auf Anfrage 6mm² outside control cabinet on request Baugröße Han 24B Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black Dichteinsatz seal insert Han Q8/0-Kg-16 Kupplungsgehäuse hood thermoplastic Han Q4/2-M-c Stifteinsatz Stift-Stecker male insert Male insert 5x Han C-Stiftkontakt, versilbert Han C male contact, silver plated Seite 113 Ausgabe 01/2013 Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge Seal insert HTG:61 83 401 0126 4mm² 12,5-16,5 grau/grey HTG:61 83 401 0127 6mm² 12,5-16,5 grau/grey HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 5.1 Steckersätze für Energiebus Anschluss Schaltschrank / Unterverteiler / Set of connectors for power bus switching cabinet/subdistributor Han Q8/0-Kg-16 Kupplungsgehäuse Überwurfmutter Pg 16 Ku, sw connecting nut PG16, thermoplastic, black hoods cable to cable Han Q4/2-M-c Stifteinsatz male insert Dichteinsatz seal insert Stift-Stecker Male insert 5x Han C-Stiftkontakt, versilbert Han C male contact, silver plated Seite 114 Ausgabe 01/2013 Artikelnummer Querschnitt Dichteinsatz Part no. Wire gauge Seal insert HTG:61 83 401 0128 4mm² 12,5-16,5 grau/grey HTG:61 83 401 0129 6mm² 12,5-16,5 grau/grey HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 5.2 Verschlußkappen / Protection covers (if there is no plug used) Abdeckkappe für Han Compact Anbaugehäuse mit Stifteinsatz Protection cover for male insert Artikelnummer Part no. HTG:09 12 008 5407 Abdeckkappe für Han Compact Tüllengehäuse mit Buchseneinsatz Protection cover for female insert Artikelnummer Part no. HTG:61 83 401 0070 Abdeckkappe für Han 10E Anbaugehäuse mit Längsbügel Cover for Han 10E mounted housing with locking latch Artikelnummer Part no. HTG:09 30 010 5432 Seite 115 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 7.3 Crimpzangen / Crimping tools Crimpzange für Han Q 4/2 crimping tool for Han Q4/2 Artikelnummer Part no. HTG:09 99 000 0303 Artikelnummer Part no. HTG:09 99 000 0110 Crimpzange für Han Q 8/0 / Han 10E crimping tool for Han Q 8/0 / Han 10E Einsatz Crimp Kontakte Insert Crimp contacts HTG:09 99 000 0303 HTG:09 99 000 0110 Han Q 4/2 Han C 4mm²-6mm² 1,5mm² - 4mm² Han D - 0,5mm² - 1,5mm² Han Q 8/0 Han E - 0,5mm² - 4mm² Han 10 E Han E - 0,5mm² - 4mm² Seite 116 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 7.4 Demontagewerkzeuge für Stifte und Buchsen Dismantle tools for male and female inserts Demontagewerkzeug für Han Q 4/2 Removal tool for Han Q 4/2 Artikelnummer Querschnitt Part no. Wire gauge HTG:09 99 000 0305 4mm²-6mm² HTG:09 99 000 0381 10mm² Artikelnummer Querschnitt Part no. Wire gauge HTG:09 99 000 0319 0,5mm²-4mm² Han C-Kontakte Han E-Kontakte Demontagewerkzeug für Han Q 8/0 / Han 10E Removal tool for Han Q 8/0 / Han 10E Demontagewerkzeug für Han D Kontakte z.B. Han Q4/2 Removal tool for Han D contacts e.g. Han Q4/2 Artikelnummer Querschnitt Part no. Wire gauge HTG:09 99 000 0012 Han D-Kontakte Seite 117 Ausgabe 01/2013 0,14-2,5mm² HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 6 7/8“ Steckleitungen 7/8 inch connector cable Buchse/female Stecker/male 24V Versorgung (EINGANG) 24V supply (IN) Pin Farbe 24V Versorgung (AUSGANG) Pin Colour 24V supply (OUT) 0 V (geschaltet/switched) 1 Black 0 V (geschaltet/switched) 0 V (ungeschaltet/unswitched) 2 Blue 0 V (ungeschaltet/unswitched) Funktionserde/ground 3 Green/Yellow +24 V (ungeschaltet/unswitched) 4 Brown +24 V (ungeschaltet/unswitched) +24 V (geschaltet/switched) 5 White +24 V (geschaltet/switched) Funktionserde/ground Elektrische und technische Daten /electrical and technical data Nennspannung / rated voltage : 24 V DC Nennspannung / rated voltage : 24 V DC Betriebsstrom pro Kontakt /operation current per contact : max. 9 A (40°C) Anschlussquerschnitt / wire diameter: max. 2,5mm² Außendurchmesser / outer diameter : 9,6….10mm Schutzart /type of protection: IP 67 Temperaturbereich / temperature range : -25°C bis + 80°C Matelmaterial / cable material : PVC, Black, UL2464 Seite 107 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 6.1 7/8“ 24 DC Einspeiseleitung 7/8 inch 24V DC cable prefabricated Artikelnummer Länge Part no. length HTG:61 88 202 0620 1,5m HTG:61 88 202 0621 2,0m HTG:61 88 202 0622 3,0m HTG:61 88 202 0623 5,0m 6.2 7/8“ 24V DC Einspeiseleitung eins. konfektioniert Buchse 7/8 inch 24V DC cable one-sided prefabricated female Artikelnummer Länge Part no. length HTG:61 88 201 0626 1,5m HTG:61 88 201 0627 2,0m HTG:61 88 201 0628 3,0m HTG:61 88 201 0629 5,0m 6.3 7/8“ 24V DC Einspeiseleitung eins. konfektioniert Stift 7/8 inch 24V DC cable one-sided prefabricated male Seite 108 Ausgabe 01/2013 Artikelnummer Länge Part no. length HTG:61 88 201 0620 1,5m HTG:61 88 201 0621 2,0m HTG:61 88 201 0622 3,0m HTG:61 88 201 0623 5,0m HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 6.4 7/8“ Steckersatz für die 7/8“ Schnittstelle (feldkonfektionierbar) Set of connectors for 7/8 inch interface (field assembled) Elektrische und technische Daten /electrical and technical data Nennspannung /rated voltage : max. 250 V AC/DC Betriebsstrom pro Kontakt /operation current per contact : max. 9 A (40°C) Anschlussquerschnitt /wire diameter: max. 1,5mm² Klemmbereich /sealing range: 6….8,7mm Schutzart /type of protection: IP 65 Temperaturbereich / temperature range : -25°C bis + 85°C Artikelnummer Beschreibung Part no. Description HTG:61 83 401 0142 7/8“ 5pol Stift gewinkelt / 7/8“ 5pole male angled HTG:61 88 201 0143 7/8“ 5pol Buchse gewinkelt / 7/8“ 5pole female angled HTG:61 88 201 0144 7/8“ 5pol Stift gerade HARAX / 7/8“ 5pole male straight HARAX HTG:61 88 201 0145 7/8“ 5pol Buchse gerade HARAX / 7/8“ 5pole female straight HARAX Abbildung nicht vorhanden Artikelnummer Beschreibung Part no. Description HTG:61 83 401 0155 7/8“ T-Stück mit Zuleitung / 7/8“ T-piece with lead Seite 109 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 7.1 M12 Profibus-Leitung M12 profibus cable Stecker/male M12 Profibus (AUS) PIN M12 Profibus (EIN) M12 Profibus (Out) pin M12 Profibus (IN) nicht belegt/not used 1 nicht belegt/not used Daten A (N)/data A (N) 2 Daten A (N)/data A (N) nicht belegt/not used 3 nicht belegt/ not used Daten B (P)/data B (P) 4 Daten B (P)/data B (P) Funktionserde/ground 5 Funktionserde/ground Buchse/female Artikelnummer Länge Part no. length HTG:61 88 202 0900 1,5m HTG:61 88 202 0901 2,0m HTG:61 88 202 0902 3,0m HTG:61 88 202 0903 5,0m Artikelnummer Länge Part no. length HTG:61 88 201 0600 1,5m HTG:61 88 201 0601 2,0m HTG:61 88 201 0602 3,0m HTG:61 88 201 0603 5,0m 7.2 M12 Profibus-Leitung Buchse M12 profibus cable one-sided prefabricated female 7.3 M12 Profibus-Leitung Stift M12 profibus cable one-sided prefabricated male Seite 110 Ausgabe 01/2013 Artikelnummer Länge Part no. length HTG:61 88 201 0610 1,5m HTG:61 88 201 0611 2,0m HTG:61 88 201 0612 3,0m HTG:61 88 201 0613 5,0m HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 7.4 M12 Profinet-Leitung M12 profinet cable one-sided prefabricated female Stecker/fale Artikelnummer Länge length PIN M12 Profibus Belegung EIN Part no. pin M12 Profibus assignment input HTG:61 88 201 0650 1,5m 1 Tx + HTG:61 88 201 0651 2,0m 2 Rx + HTG:61 88 201 0652 3,0m 3 TX - HTG:61 88 201 0653 5,0m 4 RX - 5 Funktionserde/ground Artikelnummer Länge length 7.5 M12 Geberschnittstellen Anschlussleitung M12 Encoder cable Stecker/male Seite 111 Ausgabe 01/2013 PIN M12 Geber Belegung Part no. Pin M12 Encoder assignment HTG:61 88 202 0936 1,5m 1 Kanal A/channel A HTG:61 88 202 0937 2,0m 2 Kanal A‘/channel A‘ HTG:61 88 202 0938 3,0m 3 Kanal B/channel B HTG:61 88 202 0939 5,0m 4 Kanal B‘/channel B‘ 5 Kanal Z/channel Z 6 Kanal Z‘/channel Z‘ 7 +24 V (ungeschaltet/unswitched) 8 0 V (ungeschaltet/unswitched) HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro 7.6 M12 I/O Kabel M12 interface cable for input/output Artikelnummer Länge Part no. length HTG:61 88 201 0640 1,5m HTG:61 88 201 0641 2,0m HTG:61 88 201 0642 3,0m HTG:61 88 201 0643 5,0m 7.7 Steckersätze für M12 Profibus Set of connectors for M12 Profibus Elektrische und technische Daten /electrical and technical data Nennspannung : 24 V /rated voltage Betriebsstrom pro Kontakt : 9A / operation current per contact Anschlussquerschnitt : / wire diameter Klemmbereich : 6….8,7mm / sealing range Schutzart : IP 65 / type of protection Temperaturbereich : -25°C bis + 85°C / temperature range Artikelnummer Beschreibung Part no. Description HTG:61 83 401 0150 M12 5pol Stift B-codiert geschirmt gewinkelt / M12 5pole male b-coded shielded angled HTG:61 83 401 0151 M12 5pol Buchse B-codiert geschirmt gewinkelt / M12 5pole female b-coded shielded angled HTG:61 83 401 0152 M12 5pol Stift gerade HARAX / M12 5pole male b-coded shielded straight HARAX HTG:61 83 401 0153 M12 5pol Buchse gerade HARAX / M12 5pole female b-coded shielded straight HARAX Seite 112 Ausgabe 01/2013 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro Bestell-Nummern-Verzeichnis List of part numbers ET 200pro Bestellnummer / Kapitel / Bestellnummer / Kapitel / Order number Chapter Order number Chapter HTG:61 88 201 0500 HTG:61 88 201 0501 HTG:61 88 201 0502 HTG:61 88 201 0503 HTG:61 88 201 0504 HTG:61 88 202 0770 HTG:61 88 201 0506 HTG:61 88 202 0507 HTG:61 88 202 0508 HTG:61 88 202 0509 HTG:61 88 201 0505 HTG:61 83 401 0200 HTG:61 83 401 0201 HTG:61 83 401 0202 HTG:61 83 401 0203 HTG:61 83 401 0204 HTG:61 88 203 0017 HTG:61 88 201 0330 HTG:61 88 203 0016 HTG:61 88 201 0181 HTG:61 88 600 0101 HTG:61 88 600 0102 HTG:61 88 600 0107 HTG:61 88 600 0108 HTG:61 88 600 0113 HTG:61 88 600 0114 HTG:61 88 202 0400 HTG:61 88 202 0401 HTG:61 88 202 0402 HTG:61 88 202 0403 HTG:61 88 202 0404 HTG:61 88 202 0405 HTG:61 88 202 0406 Seite 118 Ausgabe 01/2013 1,1 1,1 1,1 1,1 1,1 1,2 1,3 1,3 1,3 1,3 1,4 1,5 1,5 1,5 1,5 1,5 1,6 1,7 1,8 1,9 1,10,1 1,10,1 1,10,2 1,10,2 1,10,3 1,10,3 2,1,1 2,1,1 2,1,1 2,1,1 2,1,2 2,1,2 2,1,2 HTG:61 88 202 0407 HTG:61 88 202 0408 HTG:61 88 202 0409 HTG:61 88 202 0410 HTG:61 88 202 0411 HTG:61 88 201 0192 HTG:61 88 201 0193 HTG:61 88 201 0194 HTG:61 88 201 0195 HTG:61 88 201 0197 HTG:61 88 201 0198 HTG:61 88 201 0199 HTG:61 88 201 0200 HTG:61 88 201 0201 HTG:61 88 201 0202 HTG:61 88 201 0203 HTG:61 88 202 0412 HTG:61 88 202 0413 HTG:61 88 202 0414 HTG:61 88 202 0415 HTG:61 88 202 0416 HTG:61 88 202 0417 HTG:61 88 202 0418 HTG:61 88 202 0419 HTG:61 88 202 0420 HTG:61 88 202 0421 HTG:61 88 202 0422 HTG:61 88 202 0423 HTG:61 88 201 0310 HTG:61 88 201 0311 HTG:61 88 201 0312 HTG:61 88 201 0313 HTG:61 88 201 0184 2,1,2 2,1,3 2,1,3 2,1,3 2,1,3 2,2,1 2,2,1 2,2,1 2,2,2 2,2,2 2,2,2 2,2,2 2,2,3 2,2,3 2,2,3 2,2,3 2,3,1 2,3,1 2,3,1 2,3,1 2,3,2 2,3,2 2,3,2 2,3,2 2,3,3 2,3,3 2,3,3 2,3,3 2,4,1 2,4,1 2,4,1 2,4,1 2,4,2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro Bestell-Nummern-Verzeichnis List of part numbers ET 200pro Bestellnummer / Kapitel / Bestellnummer / Kapitel / Order number Chapter Order number Chapter HTG:61 88 201 0185 HTG:61 88 201 0186 HTG:61 88 201 0187 HTG:61 88 201 0188 HTG:61 88 201 0189 HTG:61 88 201 0190 HTG:61 88 201 0191 HTG:61 88 600 0115 HTG:61 88 600 0116 HTG:61 88 600 0117 HTG:61 88 600 0118 HTG:61 88 600 0119 HTG:61 88 600 0120 HTG:61 83 401 245 HTG:61 83 401 246 HTG:61 83 401 248 HTG:61 83 401 249 HTG:61 83 401 0251 HTG:61 83 401 244 HTG:61 83 401 247 HTG:61 88 202 0340 HTG:61 88 202 0341 HTG:61 88 202 0342 HTG:61 88 202 0343 HTG:61 88 202 0344 HTG:61 88 202 0345 HTG:61 88 202 0346 HTG:61 88 202 0347 HTG:61 88 202 0348 HTG:61 88 202 0349 HTG:61 88 202 0350 HTG:61 88 202 0351 HTG:61 88 202 0352 Seite 119 Ausgabe 01/2013 2,4,2 2,4,2 2,4,2 2,4,3 2,4,3 2,4,3 2,4,3 2,5,1 2,5,1 2,5,2 2,5,2 2,5,3 2,5,3 2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,7,1 2,7,1 2,7,1 2,7,1 2,7,2 2,7,2 2,7,2 2,7,2 2,7,3 2,7,3 2,7,3 2,7,3 2,8,1 HTG:61 88 202 0353 HTG:61 88 202 0354 HTG:61 88 202 0355 HTG:61 88 202 0356 HTG:61 88 202 0357 HTG:61 88 202 0358 HTG:61 88 202 0359 HTG:61 88 202 0360 HTG:61 88 202 0361 HTG:61 88 202 0362 HTG:61 88 202 0363 HTG:61 04 401 1004 HTG:61 04 401 1001 HTG:61 04 401 1002 HTG:61 04 401 1003 HTG:61 88 202 0424 HTG:61 88 202 0425 HTG:61 88 202 0426 HTG:61 88 202 0427 HTG:61 88 202 0428 HTG:61 88 202 0429 HTG:61 88 202 0600 HTG:61 88 202 0601 HTG:61 88 202 0602 HTG:61 88 202 0603 HTG:61 88 202 0604 HTG:61 88 202 0605 HTG:61 88 201 0211 HTG:61 88 201 0212 HTG:61 88 201 0213 HTG:61 88 201 0214 HTG:61 88 201 0215 HTG:61 88 201 0216 2,8,1 2,8,1 2,8,1 2,8,2 2,8,2 2,8,2 2,8,2 2,8,3 2,8,3 2,8,3 2,8,3 2,9 2,9 2,9 2,9 3,1,1,1 3,1,1,1 3,1,1,1 3,1,1,2 3,1,1,2 3,1,1,2 3,1,2,1 3,1,2,1 3,1,2,1 3,1,2,2 3,1,2,2 3,1,2,2 3,2,1,1 3,2,1,1 3,2,1,1 3,2,1,2 3,2,1,2 3,2,1,2 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro Bestell-Nummern-Verzeichnis List of part numbers ET 200pro Bestellnummer / Kapitel / Bestellnummer / Kapitel / Order number Chapter Order number Chapter HTG:61 88 201 0218 HTG:61 88 201 0219 HTG:61 88 201 0220 HTG:61 88 201 0221 HTG:61 88 201 0222 HTG:61 88 201 0223 HTG:61 88 202 0607 HTG:61 88 202 0608 HTG:61 88 202 0609 HTG:61 88 202 0610 HTG:61 88 202 0611 HTG:61 88 202 0612 HTG:61 88 202 0430 HTG:61 88 202 0431 HTG:61 88 202 0432 HTG:61 88 202 0433 HTG:61 88 202 0434 HTG:61 88 202 0435 HTG:61 88 600 0121 HTG:61 88 600 0122 HTG:61 88 600 0123 HTG:61 88 600 0124 HTG:61 88 600 0125 HTG:61 88 600 0126 HTG:61 88 600 0127 HTG:61 88 600 0128 HTG:61 83 401 0065 HTG:61 83 401 0066 HTG:61 83 401 0047 HTG:61 83 401 0067 HTG:61 83 401 0068 HTG:61 83 401 0069 HTG:61 88 202 0499 Seite 120 Ausgabe 01/2013 3,2,2,1 3,2,2,1 3,2,2,1 3,2,2,2 3,2,2,2 3,2,2,2 3,3,1,1 3,3,1,1 3,3,1,1 3,3,1,2 3,3,1,2 3,3,1,2 3,3,2,1 3,3,2,1 3,3,2,1 3,3,2,2 3,3,2,2 3,3,2,2 3,4 3,4 3,4 3,4 3,5 3,5 3,5 3,5 3,6 3,6 3,7,1 3,7,1 3,7,2 3,7,2 4,1,1 HTG:61 88 202 0514 HTG:61 88 202 0515 HTG:61 88 202 0500 HTG:61 88 202 0520 HTG:61 88 202 0521 HTG:61 88 202 0522 HTG:61 88 202 0523 HTG:61 88 202 0524 HTG:61 88 202 0497 HTG:61 83 401 0130 HTG:61 88 202 0525 HTG:61 88 202 0526 HTG:61 88 202 0527 HTG:61 88 202 0529 HTG:61 88 202 0530 HTG:61 88 202 0528 HTG:61 88 202 0531 HTG:61 88 202 0532 HTG:61 88 202 0533 HTG:61 88 202 0497 HTG:61 83 401 0130 HTG:61 88 201 0288 HTG:61 88 201 0289 HTG:61 88 201 0290 HTG:61 88 201 0299 HTG:61 88 201 0300 HTG:61 88 201 0291 HTG:61 88 201 0292 HTG:61 88 201 0293 HTG:61 88 201 0301 HTG:61 88 201 0302 HTG:61 88 201 0303 HTG:61 88 201 0304 4,1,1 4,1,1 4,1,2 4,1,2 4,1,2 4,1,3 4,1,3 4,1,3 4,1,4 4,1,5 4,2,1 4,2,1 4,2,1 4,2,2 4,2,2 4,2,2 4,2,3 4,2,3 4,2,3 4,2,4 4,2,5 4,3,1,1 4,3,1,1 4,3,1,1 4,3,1,1 4,3,1,1 4,3,1,2 4,3,1,2 4,3,1,2 4,3,1,2 4,3,1,2 4,3,1,3 4,3,1,3 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro Bestell-Nummern-Verzeichnis List of part numbers ET 200pro Bestellnummer / Kapitel / Bestellnummer / Kapitel / Order number Chapter Order number Chapter HTG:61 88 201 0305 HTG:61 88 201 0306 HTG:61 88 201 0307 HTG:61 88 201 0350 HTG:61 88 201 0351 HTG:61 88 201 0352 HTG:61 88 201 0353 HTG:61 88 201 0354 HTG:61 88 201 0355 HTG:61 88 201 0356 HTG:61 88 201 0357 HTG:61 88 201 0358 HTG:61 88 201 0359 HTG:61 88 201 0360 HTG:61 88 201 0361 HTG:61 88 201 0362 HTG:61 88 201 0363 HTG:61 88 201 0364 HTG:61 88 601 0004 HTG:61 88 601 0005 HTG:61 88 601 0010 HTG:61 88 601 0011 HTG:61 88 601 0006 HTG:61 88 601 0007 HTG:61 88 601 0012 HTG:61 88 601 0013 HTG:61 88 601 0008 HTG:61 88 601 0009 HTG:61 88 601 0014 HTG:61 88 601 0015 HTG:61 88 601 0016 HTG:61 88 601 0017 HTG:61 83 401 0131 Seite 121 Ausgabe 01/2013 4,3,1,3 4,3,1,3 4,3,1,3 4,3,2,1 4,3,2,1 4,3,2,1 4,3,2,1 4,3,2,1 4,3,2,2 4,3,2,2 4,3,2,2 4,3,2,2 4,3,2,2 4,3,2,3 4,3,2,3 4,3,2,3 4,3,2,3 4,3,2,3 4,4 4,4 4,4,1 4,4,1 4,5 4,5 4,5,1 4,5,1 4,6 4,6 4,6,1 4,6,1 4,7 4,7 4,8 HTG:61 83 401 0132 HTG:61 83 401 0133 HTG:61 83 401 0253 HTG:61 83 401 0120 HTG:61 83 401 0121 HTG:61 83 401 0122 HTG:61 83 401 0123 HTG:61 83 401 0124 HTG:61 83 401 0125 HTG:61 88 202 0620 HTG:61 88 202 0621 HTG:61 88 202 0622 HTG:61 88 202 0623 HTG:61 88 202 0624 HTG:61 88 202 0625 HTG:61 88 201 0626 HTG:61 88 201 0627 HTG:61 88 201 0628 HTG:61 88 201 0629 HTG:61 88 201 0630 HTG:61 88 201 0631 HTG:61 88 201 0620 HTG:61 88 201 0621 HTG:61 88 201 0622 HTG:61 88 201 0623 HTG:61 88 201 0624 HTG:61 88 201 0625 HTG:61 83 401 0142 HTG:61 83 401 0143 HTG:61 83 401 0144 HTG:61 83 401 0145 HTG:61 83 401 0155 HTG:61 88 202 0900 4,8 4,8 4,8 4,9 4,9 4,9 4,9 4,9 4,9 5,1 5,1 5,1 5,1 5,1 5,1 5,2 5,2 5,2 5,2 5,2 5,2 5,3 5,3 5,3 5,3 5,3 5,3 5,4 5,4 5,4 5,4 5,4 6,1 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-0 Fax: (0571) 8896-354 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro Bestell-Nummern-Verzeichnis List of part numbers ET 200pro Bestellnummer / Kapitel / Bestellnummer / Kapitel / Order number Chapter Order number Chapter HTG:61 88 202 0901 HTG:61 88 202 0902 HTG:61 88 202 0903 HTG:61 88 202 0904 HTG:61 88 202 0905 HTG:61 88 201 0600 HTG:61 88 201 0601 HTG:61 88 201 0602 HTG:61 88 201 0603 HTG:61 88 201 0604 HTG:61 88 201 0605 HTG:61 88 201 0610 HTG:61 88 201 0611 HTG:61 88 201 0612 HTG:61 88 201 0613 HTG:61 88 201 0614 HTG:61 88 201 0615 HTG:61 88 201 0650 HTG:61 88 201 0651 HTG:61 88 201 0652 HTG:61 88 201 0653 HTG:61 88 201 0654 HTG:61 88 201 0655 HTG:61 88 202 0936 HTG:61 88 202 0937 HTG:61 88 202 0938 HTG:61 88 202 0939 HTG:61 88 202 0940 HTG:61 88 202 0941 HTG:61 88 201 0640 HTG:61 88 201 0641 HTG:61 88 201 0642 HTG:61 88 201 0643 Seite 122 Ausgabe 01/2013 6,1 6,1 6,1 6,1 6,1 6,2 6,2 6,2 6,2 6,2 6,2 6,3 6,3 6,3 6,3 6,3 6,3 6,4 6,4 6,4 6,4 6,4 6,4 6,5 6,5 6,5 6,5 6,5 6,5 6,6 6,6 6,6 6,6 HTG:61 83 401 0150 HTG:61 83 401 0151 HTG:61 83 401 0152 HTG:61 83 401 0153 HTG:61 83 401 0116 HTG:61 83 401 0117 HTG:61 83 401 0118 HTG:61 83 401 0119 HTG:61 88 201 0051 HTG:09 12 008 5407 HTG:09 30 010 5432 HTG:61 83 401 0070 HTG:09 99 000 0110 HTG:09 99 000 0303 HTG:09 99 000 0305 HTG:09 99 000 0319 HTG:09 99 000 0012 HTG:09 99 000 0381 6,7 6,7 6,7 6,7 7,1 7,1 7,1 7,1 7,1 7,2 7,2 7,2 7,3 7,3 7,4 7,4 7,4 7,4 HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 8896-0 Fax: Fax: (0571) (0571) 8896-354 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro - weltweit Tochtergesellschaften Subsidiary companies - worldwide Albania see Eastern Europe Argentina Condelectric S.A. Hipólito Yrigoyen 2591, 1640 - Martínez Buenos Aires – Argentina Phone +54 11 4836 1053 Fax +54 11 4836 1053 [email protected] Armenia see Eastern Europe Australia HARTING Pty Ltd Suite 11 / 2 Enterprise Drive Bundoora 3083, AUS-Victoria Phone +61 3 9466 7088 Fax +61 3 9466 7099 [email protected], www.HARTING.com.au Austria HARTING Ges.m.b.H. Deutschstraße 19, A-1230 Wien Phone +431 6162121 Fax +431 6162121-21 [email protected], www.HARTING.at Azerbaijan see Eastern Europe Bahrain see United Arab Emirates Belarus see Eastern Europe Belgium HARTING N.V./S.A. Z.3 Doornveld 23, B-1731 Zellik Phone +32 2 466 0190 Fax +32 2 466 7855 [email protected], www.HARTING.be Bosnia and Herzegovina see Eastern Europe Brazil HARTING Ltda. Rua Major Paladino 128; Prédio 11 CEP 05307-000 São Paulo SP – Brazil Phone +55 11 5035 0073 Fax +55 11 5034 4743 [email protected], www.HARTING.com.br Brunei see Singapore Bulgaria see Eastern Europe Canada HARTING Canada Inc. 8455 Trans-Canada Hwy., Suite 202 St. Laurent, QC, H4S1Z1, Canada Phone 855-659-6653 Fax 855-659-6654 [email protected], www.HARTING.ca China HARTING Sales (Shanghai) Limited Room 5403, HK New World Tower 300 Huai Hai Road (M.), Luwan District Shanghai 200021, China Phone +86 21 6386 2200 Fax +86 21 6386 8636 [email protected], www.HARTING.com.cn Ausgabe 01/2013 Seite 112 Croatia see Eastern Europe Czech Republic HARTING s.r.o. Mlýnská 2, CZ-160 00 Praha 6 Phone +420 220 380 460 Fax +420 220 380 461 [email protected], www.HARTING.cz Denmark HARTING ApS Hjulmagervej 4a DK - 7100 Vejle Phone +45 70 25 00 32 Fax +45 75 80 64 99 [email protected], www.HARTING.com Eastern Europe HARTING Eastern Europe GmbH Bamberger Straße 7 D-01187 Dresden Phone +49 351 4361 760 Fax +49 351 436 1770 [email protected] www.HARTING.comt Estonia see Eastern Europe Finland HARTING Oy Teknobulevardi 3-5 FI-01530 Vantaa Phone +358 207 291 510 Fax +358 207 291 511 [email protected], www.HARTING.fi France HARTING France 181 avenue des Nations, Paris Nord 2 BP 66058 Tremblay en France F-95972 Roissy Charles de Gaulle Cédex Phone +33 1 4938 3400 Fax +33 1 4863 2306 [email protected], www.HARTING.fr Germany HARTING Deutschland GmbH & Co. KG P.O. Box 2451, D-32381 Minden Simeonscarré 1, D-32427 Minden Phone +49 571 8896 0 Fax +49 571 8896 282 [email protected] www.HARTING-Deutschland.de Georgia see Eastern Europe Great Britain HARTING Ltd., Caswell Road Brackmills Industrial Estate GB-Northampton, NN4 7PW Phone +44 1604 827 500 Fax +44 1604 706 777 [email protected], www.HARTING.co.uk Hong Kong HARTING (HK) Limited Regional Office Asia Pacific 3512 Metroplaza Tower 1 223 Hing Fong Road Kwai Fong, N. T., Hong Kong Phone +852 2423 7338 Fax +852 2480 4378 [email protected], www.HARTING.com.hk Hungary HARTING Magyarország Kft. Fehérvári út 89-95, H-1119 Budapest Phone +36 1 205 34 64 Fax +36 1 205 34 65 [email protected], www.HARTING.hu Iceland Smith & Norland, Nóatún 4 IS – 105 Reykjavík Phone +354 520 3000 Fax +354 520 3011 [email protected] , www.sminor.is India HARTING India Private Limited No. D, 4th Floor, ‚Doshi Towers‘ No. 156 Poonamallee High Road Kilpauk, Chennai 600 010 Tamil Nadu, India Phone +91 44 435604 15 / 416 Fax +91 44 435604 17 [email protected], www.HARTING.in Indonesia see Malaysia Israel COMTEL Israel Electronic Solutions Ltd. Bet Hapamon, 20 Hataas st. P.O.Box 66 Kefar-Saba 44425 Phone +972-9-7677240 Fax +972-9-7677243 [email protected], www.comtel.co.il Italy HARTING SpA Via Dell‘ Industria 7 I-20090 Vimodrone (Milano) Phone +39 02 250801 Fax +39 02 2650 597 [email protected], www.HARTING.it Japan HARTING K. K. Yusen Shin-Yokohama 1 Chome Bldg., 2F 1-7-9, Shin-Yokohama, Kohoku Yokohama 222-0033 Japan Phone +81 45 476 3456 Fax +81 45 476 3466 [email protected], www.HARTING.co.jp Jordan see United Arab Emirates Kazakhstan see Eastern Europe Kirghizia see Eastern Europe Korea (South) HARTING Korea Limited #308 Yatap Leaders Building 342-1, Yatap-dong, Bundang-gu Sungnam-City, Kyunggi-do 463-828, Republic of Korea Phone +82 31 781 4615 Fax +82 31 781 4616 [email protected], www.HARTING.co.kr HARTING Deutschland GmbH & Co. KG Simeonscarré 1 32427 Minden Deutschland Tel.: (0571) 8896-178 8896-0 Fax: Fax: (0571) (0571) 8896-354 8896-177 E-Mail: [email protected] Internet: http://www.HARTING.com ET 200pro - weltweit Tochtergesellschaften Subsidiary companies - worldwide Kosovo see Eastern Europe Kuwait see United Arab Emirates Latvia see Eastern Europe Lithuania see Eastern Europe Macedonia see Eastern Europe Malaysia (Office) HARTING Singapore Pte Ltd Malaysia Branch 11-02 Menara Amcorp Jln. Persiaran Barat 46200 PJ, Sel. D. E., Malaysia Phone +60 3 / 7955 6173 Fax +60 3 / 7955 5126 [email protected] Montenegro see Eastern Europe Netherlands HARTING B.V. Larenweg 44 NL-5234 KA ‚s-Hertogenbosch Postbus 3526 NL-5203 DM ‚s-Hertogenbosch Phone +31 736 410 404 Fax +31 736 440 699 [email protected], www.HARTINGbv.nl New Zealand see Australia Norway HARTING A/S Østensjøveien 36, N-0667 Oslo Phone +47 22 700 555 Fax +47 22 700 570 [email protected], www.HARTING.no Oman see United Arab Emirates Pakistan see United Arab Emirates Philippines see Malaysia Poland HARTING Polska Sp. z o. o ul. Kamieńskiego 201-219 PL-51-126 Wrocław Phone +48 71 352 81 71 Fax +48 71 320 74 44 [email protected], www.HARTING.pl Portugal HARTING Iberia, S. A. Avda. Josep Tarradellas 20-30 4o 6a E-08029 Barcelona Phone +351 219 673 177 Fax +351 219 678 457 [email protected], www.HARTING.es/pt Qatar see United Arab Emirates Republic of Moldova see Eastern Europe Ausgabe 01/2013 Seite 113 Romania HARTING Romania SCS Europa Unita str. 21 550018-Sibiu, Romania Phone +40 369-102 671 Fax +40 369-102 622 [email protected], www.HARTING.com Russia HARTING ZAO Maliy Sampsoniyevsky prospect 2A 194044 Saint Petersburg, Russia Phone +7 812 327 6477 Fax +7 812 327 6478 [email protected], www.HARTING.ru Saudi Arabia see United Arab Emirates Serbia see Eastern Europe Singapore HARTING Singapore Pte Ltd. 25 International Business Park #04-108 German Centre Singapore 609916 Phone +65 6225 5285 Fax +65 6225 9947 [email protected], www.HARTING.sg Slovakia HARTING s.r.o. Sales office Slovakia J. Simora 5, SK - 940 52 Nové Zámky Phone +421 356-493 993 Fax +421 356-402 114 [email protected], www.HARTING.sk Slovenia see Eastern Europe South Africa HellermannTyton Pty Ltd. Private Bag X158 Rivonia 2128 34 Milky Way Avenue Linbro Business Park 2065 Johannesburg Phone +27(0)11879-6600 Fax +27(0)11879-6606 [email protected], Spain HARTING Iberia S.A. Avda. Josep Tarradellas 20-30 4o 6a E-08029 Barcelona Phone +34 93 363 84 75 Fax +34 93 419 95 85 [email protected], www.HARTING.es Sweden HARTING AB Gustavslundsvägen 141 B 4tr S-167 51 Bromma Phone +46 8 445 7171 Fax +46 8 445 7170 [email protected], www.HARTING.se Switzerland HARTING AG Industriestrasse 26 CH-8604 Volketswil Phone +41 44 908 20 60 Fax +41 44 908 20 69 [email protected], www.HARTING.ch Taiwan HARTING Taiwan Ltd. Room 1, 5/F 495 GuangFu South Road RC-110 Taipei, Taiwan Phone +886 2 2758 6177 Fax +886 2 2758 7177 [email protected], www.HARTING.com.tw Tajikistan see Eastern Europe Thailand see Malaysia Turkey HARTING TURKEI Elektronik Ltd. Şti. Barbaros Mah. Dereboyu Cad. Fesleğen Sok. Uphill Towers, A-1b Kat:8 D:45 34746 Ataşehir, İstanbul Phone +90 216 688 81 00 Fax +90 216 688 81 01 [email protected], www.HARTING.com.tr Turkmenistan see Eastern Europe Ukraine see Eastern Europe United Arab Emirates HARTING Middle East FZ-LLC Knowledge Village, Block 2A, Office F72 P.O. Box 454372, Dubai United Arab Emirates Phone +971 4 453 9737 Fax +971 4 439 0339 [email protected], www.HARTING.ae USA HARTING Inc. of North America 1370 Bowes Road USA-Elgin, Illinois 60123 Phone +1 (877) 741-1500 (toll free) Fax +1 (866) 278-0307 (Inside Sales) [email protected] www.HARTING-USA.com Uzbekistan see Eastern Europe Vietnam see Singapore Other countries and general contact HARTING Electric GmbH & Co. KG P.O. Box 1473, D-32328 Espelkamp Phone +49 5772 47-97100 Fax +49 5772 47-495 [email protected]