prismapor n 41i
Transcrição
prismapor n 41i
PRISMAPOR LDA R ANT. FERREIRA DA SILVA 67 4475-844 MAIA TEL +351229825273 FAX +351229825266 www.prismapor.pt N. º 41 APRIL 2014 EDITORIAL Dear Readers We ended 2013 in a positive tone despite the fact and challenges of a difficult year. In reality we have made a turnover the about 6.00 million € euro, 30% more than the previous year, and this means a absolute record ever done. The purchase orders was flat about 5.5 million euro. We had exports (mainly Macau, Angola & Qatar) for about 4, 2 million euro which means 70% of the total turnover. Two important references it was the supply of all switchboards for the ARENAS Stadium in Angola for the world championship of hockey and the main office of Millennium Bank in Maputo Mozambique BIM. On the reverse side of this letter you will find the certificate of Assembly Manufacturer (Panel Builder) from Schneider Electric Portugal for 2014 of the Functional system Prisma Plus G & P up to 4000A in compliance with the requirements specified in IEC 60439-1 standard :1999+A1:2004 for the equipment type TTA proceeding to the routine tests and report in accordance with Schneider Electric Manuals. Best Regards Fabricante autorizado INSULATION CLASSES SWITCHBOARDS IN Because it is quite relevant we continue in future issues of the Newsletter, disclose the document from Direcção Geral de Energia e Geologia (December 2012) and prepared by Technical Committee for Electro technical Standardization -CTE64- Insulation Classes in Switchboards (answers to frequently asked questions) 3. What is an electrical insulation class II Switchboard? It is a switchboard (ASSEMBLY) in which the protection against electric shock is not guaranteed only by main isolation. For these electrical panels of class II are provided additional security measures, such as the double insulation or reinforced insulation. The electrical panel should be equipped with ground bus to which will be connected all conductors of protection, and never connected the enclosure to the earth. See section 236.4, 236.5 and 237.3 of RTIEBT See section 7.3 of IEC 61439-1 has the same interpretation. 4. It can be constructed an electrical insulating class II switchboard with a metal enclosure? Yes, it can be built: By the manufacturer in serial products(originally class II) and with the respective origin marking class II. By the manufacturer of the assembly, using a class I metal enclosure to build an electrical classII switchboard in compliance with the criteria of extra insulation provided in Annex I part 4 of the RTIEBT. The metal enclosure can not be connected to earth . The equipment that does not have double insulation or reinforced insulation should be separated from the metal by extra insulation. For protection of the active parts, must be complied the measures indicated in Annex I and V part 4 of RTIEBT. (see next newsletter) PSC PRISMAPLUS? CALL PRISMAPOR!!!! TEL: +351229825273 FAX+351229825266 www.prismapor.pt
Documentos relacionados
prismapor n 48i
Because it is quite relevant we are going, in future issues of the Newsletter, disclose the document from Direcção Geral de Energia e Geologia (December 2012) and prepared by Technical Committee fo...
Leia mais