Banho para teste de envelhecimento de cerveja

Transcrição

Banho para teste de envelhecimento de cerveja
Accessories Recirculating Coolers
Order No.
Description
Suitable for
1 m CR tubing, 8 mm inner dia. (-20 ... +120 °C)
1 m CR ® tubing, 10 mm inner dia. (-20 ... +120 °C)
1 m CR ® tubing, 12 mm inner dia. (-20 ... +120 °C)
1 m Reinforced tubing, 8 mm inner dia. (-40 ... +120 °C)
1 m Reinforced tubing, 12 mm / 1/2“ inner dia. (-40 ... +120 °C)
1 m Reinforced tubing, 3/4“ inner dia. (-40 ... +120 °C)
1 m Reinforced tubing, 1“ inner dia. (-40 ...+120 °C)
AWC100, F200, FL300
AWC100, F200
FL300
FL601/1201/1701 + FC series
FL601/1201/1701 + FC series
FL(W)1203/1703/2503/4003
FL(W)2506/4006/7006/11006
Tubing
8 930 008
8 930 010
8 930 012
8 930 308
8 930 312
8 930 319
8 930 325
®
Tubing insulations
Reinforced tubing
CR® tubing
8 930 410
1 m Insulation, 14 mm inner dia.
8 930 412
1 m Insulation, 18 mm inner dia.
1 m Insulation, 23 mm inner dia.
1 m Insulation, 29 mm inner dia.
1 m Insulation, 35 mm inner dia.
8 930 413
8 930 419
8 930 425
CR® tubing 8 to 10 mm inner dia.
CR® tubing 12 mm ID and
Reinforced tubing 8 mm lD
Reinforced tubing 12 mm/ 1/2“ lD
Reinforced tubing 3/4“ lD
Reinforced tubing 1“ ID
Instruments for special applications
• Beer Forcing Test
Refrigerated/Heating Circulating Bath
For simulating the beer aging process to
determine the ‘best before’ date
Forcing test
Program steps
• Temperature and time-dependent test ramps
according to forcing test already pre-programmed
• Program modification possible any time
• Built-in counter for temperature cycles
• Large bath opening with insert for
20 bottles of beer each 0.5 liters
• Removable Plexiglas® cover
°C
60
50
40
30
20
10
0
24
0
48
72
96 h
F38-ME
Tube clamps
Tubing insulation
Tube clamps
8 970 480
2 Tube clamps, size 1
8 970 481
2 Tube clamps, size 2
8 970 482
8 970 483
8 970 484
2 Tube clamps, size 3
2 Tube clamps, size 4
2 Tube clamps, size 5
CR® tubing 8 inner dia.
CR® tubing 10 and 12 mm ID and
Reinforced tubing 8 mm lD
Reinforced tubing 12 mm/ 1/2“ lD
Reinforced tubing 3/4“ lD
Reinforced tubing 1“ ID
Twin distributing adapters / Quad distributing adapters
8 970 470
8 970 472
8 970 471
8 970 476
8 970 477
8 970 474
8 970 520 1)
8 970 522 1)
8 970 524 1)
Twin distributing adapter
Quad distributing adapter
Twin distributing adapter with barbed fittings for tubing 8 mm lD
Twin distributing adapter with barbed fittings for tubing 10 mm lD
Twin distributing adapter with barbed fittings for tubing 12 mm lD
Twin distribut. adapter G 3/4“ with barbed fittings for tubing 3/4“ lD
Twin distribut. adapter G 11/4“ with barbed fittings for tubing 1“ lD
2 Quad distributing adapters, M16x1,
with barbed fittings for tubing 8 mm or 12 mm/1/2“ inner dia.
2 Quad distributing adapters, M16x1,
with barbed fittings for tubing 8 mm or 12 mm/1/2“ inner dia.
2 Quad distributing adapters, G 3/4“ female,
with barbed fittings for tubing 3/4“ inner dia.
2 Quad distributing adapters, G 11/4“ female,
with barbed fittings for tubing 1“ inner dia.
JULABO
Order No.
FL(W)601/1201/1701
FL(W)1203/1703/2503/4003
FL(W)2506/4006/7006/11006
1) Recommendation: Use shut-off valves additionally.
Solenoid valve for
return flow safety device
2 Adapters G 3/4“ female to M16x1 male
2 Adapters G11/4“ female to M16x1 male
2 Adapters G 3/4“ female to barbed fitting for tubing 1/2“ inner dia.
2 Adapters G 3/4“ female to barbed fitting for tubing 3/4“ inner dia.
2 Adapters G11/4“ female to barbed fitting for tubing 1/2“ inner dia.
2 Adapters G11/4“ female to barbed fitting for tubing 3/4“ inner dia.
2 Adapters G11/4“ female to barbed fitting for tubing 1“ inner dia.
2 Adapters G 3/4“ female to NPT 1/2“ male
2 Adapters G 3/4“ female to NPT 3/4“ male
2 Adapters G11/4“ female to NPT 1/2“ male
2 Adapters G11/4“ female to NPT 3/4“ male
2 Adapters G11/4“ female to NPT 1“ male
FL(W)1203/1703/2503/4003
FL(W)2506/4006/7006/11006
FL(W)1203/1703/2503/4003
FL(W)1203/1703/2503/4003
FL(W)2506/4006/7006/11006
FL(W)2506/4006/7006/11006
FL(W)2506/4006/7006/11006
FL(W)1203/1703/2503/4003
FL(W)1203/1703/2503/4003
FL(W)2506/4006/7006/11006
FL(W)2506/4006/7006/11006
FL(W)2506/4006/7006/11006
Shut-off valves / Solenoid valve / Earthquake anchors
8 970 456
8 970 454
8 970 458
8 980 701
8 920 051
8 920 052
Shut-off valve for loop circuit, M16x1
Shut-off valve G 3/4“
Shut-off valve G 11/4“
Solenoid valve set for loop circuit (max. +100 °C), M16x1
Earthquake anchors
Earthquake anchors
FL300/601/1201,1701, FC series
FL1203/1703/2503/4003
FL(W)2506/4006/7006/11006
FC series (return flow safety device)
FL(W)2503/2506/4003/4006
FL(W)7006/11006
External Pt100 sensors
External Pt100 sensor /
M+R in-line Pt100 sensor
8 981 003
8 981 020
External Pt100 sensor, 200 x 6 mm dia., stainless steel
M+R in-line Pt100 sensor, including 2 fittings M16x1 male
(for installation in the loop circuit)
Bath fluids / Lab automation see pages 31 / 57
-38 ... 80
±0.05
Heat. Cooling capacity kW
cap. (Bath fluid: Ethanol)
kW 20
0 -20°C
Pump capacity
Flow rate / Pressure
l/min.
bar
Bath opening/ Filling Dimensions
bath depth
volume W x L x H
W x L / D cm liters
cm
Weight
kg
F38-ME
2
0.92
0.66
0.32
11-16
0.23-0.45
35 x 41 / 27
45
46 x 70 x 89
72
• Refrigerated/Heating Circulators
for MOCVD applications
for temperature control of bubblers in the circulator bath
Benefits:
• Ventilation-air-cooling, instead of water-cooling
• Bath openings for one or two bubblers
• Active Cooling Control throughout
the entire temperature range
• Removable venting grid
• Front drain accessibility
Model
selection:
FS20-MC / FW20-MC:
FS30-MC / FW30-MC:
JULABO
Order No.
JULABO
Model
Usable
bath depth:
180 mm
230 mm
Working
temp.
range °C
Refrigerated/
Heating Circulators
9 150 622
9 150 636
FS20-MC
FS30-MC
Temp.
stab.
°C
FS20-MC
Heat.
cap.
kW 1)
FS30-MC
Cooling capacity kW Pump capacity Bath opening/
(Bath fluid: Ethanol) Flow rate/Pressure bath depth
20
0
-20°C l/min.
bar W x L / D cm
Fill. Dimensions
vol. W x D x H
liters cm
Weight
kg
Technical features
(see fold-out page)
-25 ... +80
-30 ... +80
±0.02
±0.02
2/1
2/1
0.26
0.46
0.2
0.34
0.06 11-16
0.15 11-16
0.45
0.45
11 x 11 / 20
22 x 14 / 25
5 ... 7
12... 15
23 x 42 x 66
31 x 42 x 75
34
42
±0.02
±0.02
2/1
2/1
0.26
0.46
0.2
0.34
0.06
0.15
0.45
0.45
11 x 11 / 20
22 x 14 / 25
5 ... 7
12... 15
23 x 42 x 66
31 x 42 x 75
34
42
water-cooled models
FC1200T, FC1600T, FCW2500T:
external measurement &
control
9 150 623
9 150 635
1)
56
Temp.
stab.
°C
Voltage: Available in 230V/50Hz or 230V/60Hz
Connectors / Stainless steel adapters
8 890 040
8 890 041
8 890 042
8 890 043
8 890 044
8 890 045
8 890 046
8 890 047
8 890 048
8 890 049
8 890 050
8 890 051
Working
temp.
range °C
Technical
features
9 160 638
FL + FC series
FL + FC series
FL + FC series
FL(W)1203/1703/2503/4003
FL(W)2506/4006/7006/11006
FC series
JULABO
Model
FW20-MC
FW30-MC
-25 ... +80
-30 ... +80
11-16
11-16
At voltage: 230V/50Hz / 115V/60Hz
57

Documentos relacionados