9. WIRING DIAGRAM FOR CONNECTING COMBI
Transcrição
9. WIRING DIAGRAM FOR CONNECTING COMBI
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram for connecting combi-steam ovens model 2003 Wiring diagram DAG 6 (10) I C3,P3,S3 Wiring diagram DA 623I C1,P1,S1 Wiring diagram DA 6I P1,S1 Wiring diagram DA 6I C2 Wiring diagram DA 6B P1,S1 Wiring diagram DA 6B C2 Wiring diagram DA 6I C2W Wiring diagram DA 6B C2W Wiring diagram DA 10I P1,S1 Wiring diagram DA 10I C2 Wiring diagram DA 10B P1,S1 Wiring diagram DA 10B C2 Wiring diagram DA 10I C2W Wiring diagram DA 10B C2W Wiring diagram DA 20I P1,S1 Wiring diagram DA 20I C2 Wiring diagram DA 20B P1,S1 Wiring diagram DA 20B C2 Wiring diagram DA 20I C2W Wiring diagram DA 20B C2W Arrangement of connectors on the board of the electronic control sensors 9-1 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS IMPORTANT INFORMATION FOR CHANGING SUPPLY FROM 3NPE AC 400V/50/60Hz TO 3PE AC 230V/50/60Hz! When the combi oven is wired for the voltage 3NPE AC 400V/50/60Hz and power supply is 3PE AC 230V/50/60Hz the following changes in the unit must be done: The convection heating elements and boiler heating elements must be changed from a Star to Delta connection. Connect N and X2:4 with the power supply terminal using the terminal bridge supplied with the wiring diagram. Change the voltage label on the power supply terminals and on the nameplate! MOTOR IN MODEL STANDARD AND PRACTIC: The Star connection of the motor cable must be disconnected and reconnected to Delta as follows: Terminal X7:1 - U1, W2 Terminal X7:2 - V1, U2 Terminal X7:3 - W1, V2 MOTOR IN MODEL COMFORT: The motor must be changed to motor for voltage 3PE AC 230V/50Hz connected to Star connection. ATTENTION !!! look for correct direction of the motor! IMPORTANT INFORMATION FOR CHANGING SUPPLY FROM 3PE AC 230V/50/60Hz TO 3NPE AC 400V/50/60Hz! When the combi oven is wired for the voltage 3PE AC 230V/50/60Hz and power supply is 3NPE AC 400V/50/60Hz the following changes in the unit must be done: The convection heating elements and boiler heating elements must be changed from a Delta to Star connection. Disconnect terminal bridge between N and X2:4 at the power supply terminal. Change the voltage label on the power supply terminals and on the nameplate! MOTOR IN MODEL STANDARD AND PRACTIC: The Delta connection of the motor cable must be disconnected and reconnected to Star as follows: Terminal X7:1 - U1 Terminal X7:2 - V1 Terminal X7:3 - W1 Terminal X7:4 – U2, V2, W2 MOTOR IN MODEL COMFORT: The motor must be changed to motor for voltage 3NPE AC 400V/50Hz connected to Star connection. ATTENTION !!! look for correct direction of the motor! ! ATTENTION ! INCORRECT WIRING OF THE UNIT INVALIDATES ALL WARRANTIES ! 9-2 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DAG 6 (10) I C3,P3,S3 9-3 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 623I C1,P1,S1 9-4 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6IP1,S1 3PE AC/230V/50/60Hz 9-5 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6IP1,S1 3NPE AC/400V/50/60Hz 9-6 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6IC2 3PE AC/230V/50/60Hz 9-7 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6IC2 3NPE AC/400V/50/60Hz 9-8 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6BP1,S1 3PE AC/230V/50/60Hz 9-9 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6BP1,S1 3NPE AC/400V/50/60Hz 9-10 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6BC2 3PE AC/230V/50/60Hz 9-11 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6BC2 3NPE AC/400V/50/60Hz 9-12 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6IC2W 3PE AC/230V/50/60Hz 9-13 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6IC2W 3NPE AC/400V/50/60Hz 9-14 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6BC2W 3PE AC/230V/50/60Hz 9-15 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 6BC2W 3NPE AC/400V/50/60Hz 9-16 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10I S1,P1 3PE AC/230V/50/60Hz 9-17 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10I S1,P1 3NPE AC/400V/50/60Hz 9-18 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10I C2 3PE AC/230V/50/60Hz 9-19 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10I C2 3NPE AC/400V/50/60Hz 9-20 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10B S1,P1 3PE AC/230V/50/60Hz 9-21 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10B S1,P1 3NPE AC/400V/50/60Hz 9-22 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10B C2 3PE AC/230V/50/60Hz 9-23 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10B C2 3NPE AC/400V/50/60Hz 9-24 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10I C2W 3PE AC/230V/50/60Hz 9-25 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10I C2W 3NPE AC/400V/50/60Hz 9-26 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10B C2W 3PE AC/230V/50/60Hz 9-27 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 10B C2W 3NPE AC/400V/50/60Hz 9-28 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20I S1,P1 3PE AC/230V/50/60Hz 9-29 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20I S1,P1 3NPE AC/400V/50/60Hz 9-30 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20I C2 3PE AC/230V/50/60Hz 9-31 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20I C2 3NPE AC/400V/50/60Hz 9-32 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20B S1,P1 3PE AC/230V/50/60Hz 9-33 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20B S1,P1 3NPE AC/400V/50/60Hz 9-34 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20B C2 3PE AC/230V/50/60Hz 9-35 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20B C2 3NPE AC/400V/50/60Hz 9-36 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20I C2W 3PE AC/230V/50/60Hz 9-37 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20I C2W 3NPE AC/400V/50/60Hz 9-38 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20B C2W 3PE AC/230V/50/60Hz 9-39 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Wiring diagram DA 20B C2W 3NPE AC/400V/50/60Hz 9-40 9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS Points connected on the power sources of the RETIGO combi-oven – model 2003 CABEL TO PANEL PANEL MEASURING BOARD BLOCKING GAZ DOOR (TÜR) FLAP VALVE (KLAPPE) MOTOR (MOTOR) LEVEL (NIVEAU) SPACE 1 (ZONE 1) TRANSPAREN T RED (ROT) YELLOW (GELB) SPACE 2 (ZONE 2) CORE (FÜHLER) BLUE (BLAU) WHITE (WEISS) BLACK (SCHWARZ) BOILER (BOILER) STEAM (DAMPF) WASTE (ABLAUF) Points connected on the sensor board of the RETIGO combi-oven – model 2003 9-41
Documentos relacionados
Universidade do Minho Escola de Engenharia Departamento de
WJXE!Y[ZDU\A&]^?BA&H _`J^T.UVa;R^H\NcbdT.J <@"2, ';%,2$%()+"';*<892$! :';*<89'7"0 #-03! "e 2$+!,' 2 03' %( <%,)56' 7/#108 #1:';*v83 %,'30R%"!O- ' R2$89';:B#- f ...
Leia maistabela de preços
X1/9 1500cc SOHC 8v inj. (E/c 138 AS 000) 124 Spyder (USA vers.) 2000cc DOHC 8v 127 Abarth 1100cc SOHC
Leia mais