9. WIRING DIAGRAM FOR CONNECTING COMBI

Transcrição

9. WIRING DIAGRAM FOR CONNECTING COMBI
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram for connecting combi-steam ovens model 2003





















Wiring diagram DAG 6 (10) I C3,P3,S3
Wiring diagram DA 623I C1,P1,S1
Wiring diagram DA 6I P1,S1
Wiring diagram DA 6I C2
Wiring diagram DA 6B P1,S1
Wiring diagram DA 6B C2
Wiring diagram DA 6I C2W
Wiring diagram DA 6B C2W
Wiring diagram DA 10I P1,S1
Wiring diagram DA 10I C2
Wiring diagram DA 10B P1,S1
Wiring diagram DA 10B C2
Wiring diagram DA 10I C2W
Wiring diagram DA 10B C2W
Wiring diagram DA 20I P1,S1
Wiring diagram DA 20I C2
Wiring diagram DA 20B P1,S1
Wiring diagram DA 20B C2
Wiring diagram DA 20I C2W
Wiring diagram DA 20B C2W
Arrangement of connectors on the board of the electronic control
sensors
9-1
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
IMPORTANT INFORMATION FOR CHANGING SUPPLY FROM 3NPE AC
400V/50/60Hz TO 3PE AC 230V/50/60Hz!
When the combi oven is wired for the voltage 3NPE AC 400V/50/60Hz and power supply is
3PE AC 230V/50/60Hz the following changes in the unit must be done:
The convection heating elements and boiler heating elements must be changed from a Star to
Delta connection. Connect N and X2:4 with the power supply terminal using the terminal
bridge supplied with the wiring diagram. Change the voltage label on the power supply
terminals and on the nameplate!
MOTOR IN MODEL STANDARD AND PRACTIC:
The Star connection of the motor cable must be disconnected and reconnected to Delta as
follows:
Terminal X7:1 - U1, W2
Terminal X7:2 - V1, U2
Terminal X7:3 - W1, V2
MOTOR IN MODEL COMFORT:
The motor must be changed to motor for voltage 3PE AC 230V/50Hz connected to Star
connection.
ATTENTION !!! look for correct direction of the motor!
IMPORTANT INFORMATION FOR CHANGING SUPPLY FROM 3PE AC
230V/50/60Hz TO 3NPE AC 400V/50/60Hz!
When the combi oven is wired for the voltage 3PE AC 230V/50/60Hz and power supply is
3NPE AC 400V/50/60Hz the following changes in the unit must be done:
The convection heating elements and boiler heating elements must be changed from a Delta to
Star connection. Disconnect terminal bridge between N and X2:4 at the power supply
terminal. Change the voltage label on the power supply terminals and on the nameplate!
MOTOR IN MODEL STANDARD AND PRACTIC:
The Delta connection of the motor cable must be disconnected and reconnected to Star as
follows:
Terminal X7:1 - U1
Terminal X7:2 - V1
Terminal X7:3 - W1
Terminal X7:4 – U2, V2, W2
MOTOR IN MODEL COMFORT:
The motor must be changed to motor for voltage 3NPE AC 400V/50Hz connected to Star
connection.
ATTENTION !!! look for correct direction of the motor!
! ATTENTION ! INCORRECT WIRING OF THE UNIT INVALIDATES
ALL WARRANTIES !
9-2
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DAG 6 (10) I C3,P3,S3
9-3
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 623I C1,P1,S1
9-4
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6IP1,S1 3PE AC/230V/50/60Hz
9-5
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6IP1,S1 3NPE AC/400V/50/60Hz
9-6
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6IC2 3PE AC/230V/50/60Hz
9-7
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6IC2 3NPE AC/400V/50/60Hz
9-8
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6BP1,S1 3PE AC/230V/50/60Hz
9-9
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6BP1,S1 3NPE AC/400V/50/60Hz
9-10
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6BC2 3PE AC/230V/50/60Hz
9-11
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6BC2 3NPE AC/400V/50/60Hz
9-12
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6IC2W 3PE AC/230V/50/60Hz
9-13
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6IC2W 3NPE AC/400V/50/60Hz
9-14
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6BC2W 3PE AC/230V/50/60Hz
9-15
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 6BC2W 3NPE AC/400V/50/60Hz
9-16
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10I S1,P1 3PE AC/230V/50/60Hz
9-17
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10I S1,P1 3NPE AC/400V/50/60Hz
9-18
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10I C2 3PE AC/230V/50/60Hz
9-19
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10I C2 3NPE AC/400V/50/60Hz
9-20
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10B S1,P1 3PE AC/230V/50/60Hz
9-21
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10B S1,P1 3NPE AC/400V/50/60Hz
9-22
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10B C2 3PE AC/230V/50/60Hz
9-23
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10B C2 3NPE AC/400V/50/60Hz
9-24
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10I C2W 3PE AC/230V/50/60Hz
9-25
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10I C2W 3NPE AC/400V/50/60Hz
9-26
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10B C2W 3PE AC/230V/50/60Hz
9-27
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 10B C2W 3NPE AC/400V/50/60Hz
9-28
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20I S1,P1 3PE AC/230V/50/60Hz
9-29
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20I S1,P1 3NPE AC/400V/50/60Hz
9-30
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20I C2 3PE AC/230V/50/60Hz
9-31
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20I C2 3NPE AC/400V/50/60Hz
9-32
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20B S1,P1 3PE AC/230V/50/60Hz
9-33
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20B S1,P1 3NPE AC/400V/50/60Hz
9-34
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20B C2 3PE AC/230V/50/60Hz
9-35
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20B C2 3NPE AC/400V/50/60Hz
9-36
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20I C2W 3PE AC/230V/50/60Hz
9-37
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20I C2W 3NPE AC/400V/50/60Hz
9-38
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20B C2W 3PE AC/230V/50/60Hz
9-39
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Wiring diagram DA 20B C2W 3NPE AC/400V/50/60Hz
9-40
9. WIRING DIAGRAM FOR CONNECTING COMBI-OVENS
Points connected on the power sources of the RETIGO combi-oven – model
2003
CABEL TO PANEL PANEL
MEASURING BOARD
BLOCKING
GAZ
DOOR
(TÜR)
FLAP VALVE
(KLAPPE)
MOTOR
(MOTOR)
LEVEL
(NIVEAU)
SPACE 1
(ZONE 1)
TRANSPAREN
T
RED
(ROT)
YELLOW
(GELB)
SPACE 2
(ZONE 2)
CORE
(FÜHLER)
BLUE
(BLAU)
WHITE
(WEISS)
BLACK
(SCHWARZ)
BOILER
(BOILER)
STEAM
(DAMPF)
WASTE
(ABLAUF)
Points connected on the sensor board of the RETIGO combi-oven – model
2003
9-41

Documentos relacionados

Universidade do Minho Escola de Engenharia Departamento de

Universidade do Minho Escola de Engenharia Departamento de WJXE!Y[ZDU\A&]^?BA&H _`J^T.UVa;R^H\NcbdT.J <@"2, ';%,2$%()+"';*<892$! :';*<89'†7"0 #-03! "e 2$+!,' 2 03' %( <%,)56' 7/#108 #1:';*v83 %,'30R%"!O- ' R2$€89';:B#- f ...

Leia mais

tabela de preços

tabela de preços X1/9 1500cc SOHC 8v inj. (E/c 138 AS 000) 124 Spyder (USA vers.) 2000cc DOHC 8v 127 Abarth 1100cc SOHC

Leia mais