HEAVY OIL BURNERS OILFLAM 700.1 PR/MD OILFLAM 800.1 PR
Transcrição
HEAVY OIL BURNERS OILFLAM 700.1 PR/MD OILFLAM 800.1 PR
HEAVY OIL BURNERS techniques for energy saving MODEL OILFLAM 700.1 PR/MD OILFLAM 800.1 PR/MD AIR DAMPER MOTOR 230 / 400 V 50 Hz LB 1312 03.02.2005 LB1312 Oilflam 700.1-800.1 PR/MD TECHNICAL DATA MODELS OILFLAM 700.1 PR/MD OILFLAM 800.1 PR/MD kcal/h kW kcal/h kW kg/h kg/h 6.250.000 7.250 2.096.270 2.417 638 214 7.327.500 8.500 2.385.100 2.750 748 243 kW N° kW V kV/mA LANDIS kcal/kg 15 2800 30 230/400 13/35 LAL2.25 Thermal power max. Thermal power min. Oil capacity max. Oil capacity min. Max. viscosity Fan motor Rpm Main resistances Voltage 50 Hz Ignition transformer Control box Calorific power 50° E a 50 °C 18,5 2800 30 230/400 13/35 LAL2.25 9.800 WORKING FIELDS mbar 36 Pressure in the combustion chamber 34 32 30 28 26 24 22 20 OI LF 18 LA M 16 OI LF 14 LA M 12 80 0.1 70 0.1 10 8 6 4 2 0 1000 1000 100 2000 2000 200 3000 3000 4000 4000 300 5000 400 5000 6000 500 6000 7000 600 Burner output - pag.2 - 7000 8000 700 8000 9000 800 9000 10000 900 10000 11000 1000 12000 11000 kcal/h x 1000 13000 kW 1100 kg/h LB1312 Oilflam 700.1-800.1 PR/MD OVERALL DIMENSIONS A E D - D1 B F C I 0 1 2 3 I O G M H L MODELS OILFLAM 700.1 PR A B 1480 660 C 820 D 455 OILFLAM 800.1 PR 1480 660 820 455 D1 E F - 1240 425 - 1240 425 G 800 H 480 I L M 460 460 M20 800 480 460 460 M20 D= Short head ; D1= Long head BURNER INSTALLATION 1 2 3 4 5 6 7 1 2 3 4 5 6 7 - BURNER NUT WASHER GASKET BOLT BOILER GASKET OIL PUMP 1 2 3 4 5 6 7 230V 50Hz WARNING: For a correct working of the pump, verify what follows: Pump : Oil temperature at the pump: Maximum allowable pressures: SUNTEC TA..C40105 Max. 140 °C Max. 5 bar on inlet - pag.3 - - Suction Return Bleed and pressure gauge port Vacuum gauge port Pressure adjustment Nozzle outlet Heating element pump LB1312 Oilflam 700.1-800.1 PR/MD PUMP’S PRESSURE / OIL TEMPERATURE DIAGRAM Pump inlet pressure:the vaporisation of light fraction of heated heavy oil causes premature pump wear, to avoid this, use the inlet pressures shown in the graph. bar 6 5 Pump inlet pressure 4 3 2 1 0 50 100 150 C° Oil temperature CHECKS TO BE MADE TO ENSURE A PROPER INSTALLATION: Before proceeding with the filling of the fuel system and subsequent burner start up, it is advisable to carry out the following checks: - Power line must be adequate to system’s adsorbed load - Fuses must be adequate to the system’s load - Boiler’s thermostats must have been properly connected - Voltage and frequency must be within the specified limits - Fuel type must be the one specified by the burner manufacturer - Feed piping section must be adequate to the requested fuel flow rate - Filters, cocks as well as fittings must have been properly installed - Blast tube length must be the one specified by the boiler manufacturer - Nozzle’s flow rate of the burner must be adequate to boiler’s output - pag.4 - LB1312 Oilflam 700.1-800.1 PR/MD TYPE OF INSTALLATION The burner must be supplied with oil heaving a min. temperature at the pump ( 50° C ). Drawing for fluid fuel oil up to 50°E at 50°C 1 - Burner 2 - Tank 3 - Heater 4 - Safety/operation thermostat 5 - Level switch 67 - Filter 8 - Load pumps 9 - Holding basin Hot water Drawing for heavy fuel oil up to 50°E at 50°C Hot water Return section hot water pipe oil pipe oil pipe heating cable hot water pipe - pag.5 - insulation 1 - Burner 2 - Tank 3 - Heater 4 - Safety/operation thermostat 5 - Level switch 6 - Self cleaning filter 7 - Heating coil 8 - Load pumps 9 - Ring pumps 10 - Regulator 11 - Heating cable LB1312 Oilflam 700.1-800.1 PR/MD MODULATING OPERATION With the bumer in the start position and the appliance thermostats enabled, power is delivered to the resistances (G) of the preheater and heating cartridges for the pumps and the fuel supply line to the head (O). When the preheater thermostat reaches the set value, (usually a minimum of about 90°C is necessary to guarantee a good level of circulation) the pump start-up is enabled (set point on out 1, if using the GEFRAN 200 thermoregulating device). If the preheating system of the tank is also equipped for a fluid exchanger (hot water, steam, diathermic oil) the thermostat may enable a contact in the terminal block for any stop-start of the fluid electrovalve. This is not a standard solution as the heated fluid is normally always connected. The pump starts to send oil (the head has already been heated by its cartridge (O) and therefore has no residue of cold dense oil) which flows from the tank to the head and then to the return line of the ring. When the head thermostat reaches the set value (usually about 70-30°C the cycle starts properly and the control programmer enables start-up. The servomotor sets itself at minimum (see chapter on regulation) acting on the air and fùel via the pressure regulator on the return. The electromagnet (A) opens the nozzle (Q) in the followmg condition : - sparks from the ignition electrodes are generated by the transformer also governed by the burner control device. If the cell fails to detect the flame the burner shuts down (with the cyclic control programmer cutting in). Once ignition has taken place and after the flame stabilisation period, the system starts operating in modulating mode. - Before start-up make sure that the pump and delivery pipes are completely filled with hot fuel oil; the absence of fuel oil can cause pump seizure. - If there is a block, a specific waring light on the programmer and on the burner front control board lights up and this signal is usually sent to the main control board of the equipment using the burner, setting off a buzzer and warning light. - A few blocks are normal on first starting up (up to about 4); to release press the button on the programmer (also found on the front of the bumer control board) for repeating the start cycle. Should they continue to occur seek the help of a specialised technician. N.B. The position of the programmer at the time of the block is memorised to supply an indication of the cause of this block. OIL DELIVERY ADJUSTMENT The diagram illustrates the fuel feeding system of these type of burners, which incorporates a by-pass nozzle with oil flow regulation on its return pipe. The oil supply is varied by acting on the nozzle through the pressure in the return line. Max. oil supply is therefore reached when the pressure in the pump line is about 30 bar and the return line is fully closed; min. oil supply when the return line is fully open(see also diagram BERGONZO). Relevant pressure readings in the return line are as follows (return oil pressure has to be measured on “M” pressure gauge): + - Pump pressure 25-30 bar. Max Burner output, return oil pressure: FLUIDICS nozzle : 16 ÷19 bar. BERGONZO nozzle : 20 ÷24 bar. Min Burner output, return oil pressure: FLUIDICS nozzle : 6 ÷9 bar BERGONZO nozzle : 4 ÷8 bar - pag.6 - LB1312 Oilflam 700.1-800.1 PR/MD - pag.7 - LB1312 Oilflam 700.1-800.1 PR/MD FLUIDICS NOZZLE - pag.8 - LEGEND : A Solenoid valve (N.C.) D Regulator E Tank F Anti - gas valve G Resistance of the preheather H Pipe filter I Oil pump N Manometr O Resistance of combustion head P Oil temperature sensor Q Oil nozzle Q PRE - PURGING PHASE D G H F P E A I N LB1312 Oilflam 700.1-800.1 PR/MD - pag.9 - LB1312 Oilflam 700.1-800.1 PR/MD COMBUSTION AIR FLOW ADJUSTMENT LANDIS SQM 50.481A2 Remove cover to gain access to the adjusting cams. The cams are to be adjusted through the suitable key provided . Description: I - Limit switch for air damper “High Flame” position adjustment. II - Limit switch for ignition flame “Min power” position adjustment. III - Limit switch for air damper “Low Flame” position adjustment. IV - Limit switch “NOT USED” V - Limit switch “NOT USED” VI - Limit switch “NOT USED” VII - Limit switch “NOT USED”. VIII - Limit switch “NOT USED”. ADJUSTMENT OF FUEL TEMPERATURE Display Decrease key Increase key “Function” key The display shows oil temperature. The 4 leds are related to the following functions: Out 1: pump start Out 2: stage 1st resistance (1/4 of the power) Out 3: stage 2nd resistance (1/2 of the power) Out 4: stage 3rd resistance (1/4 of the power) - The temperatures are already properly Factory setted : - pag.10 - LB1312 Oilflam 700.1-800.1 PR/MD Out 1(90°)- Out 2(115°)- Out 3(118°)- Out 4(120°). - To modify factory temperature setting act as follows: - press key “F” - the led Out 1 starts to flash, if You need to modify minimum oil temperature press increase or decrease button, after confirm the new value pressing again “F” - if You need to modify an other temperature press again “F” untill You the relevant led flashes. Please take care: if key “F” is pressed for a too long time, You enter in “configuration level” phase1, (see “CF1” on the display); these parameters are Factory setted and they have not to be modified: if You enter this function – You see “CF1” flashing on the display – wait 10 seconds untill the regulator automatically goes out from “configuration level”. POSITION OF IGNITION ELECTRODES For a correct burner ignition, carefully respect the dimensions shown by the picture 3 ÷ 4 mm 5 ÷ 6 mm BURNER MAINTENANCE - pag.11 - LB1312 Oilflam 700.1-800.1 PR/MD RWF 40 MICROPROCESSOR REGULATOR Description of display and keys on the RWF 40 microprocessor regulator The figure shows the normal display indicating the actual value and the programmed set point, and equally important, gives the meaning of the single keys and indicator Leds. Display: analog input 1 (actual value) Display: Set point SP1 Reduce power CLOSE/1st Stage Manual operation Burner operation Auxiliary contact Two-stage operation Increase value Increase power OPEN/2nd Stage Decrease value EXIT key. Programming key PROGRAMMING LEVELS Normal display min 2s PGM PGM PGM User Level PGM min 2s PGM PGM Parameters level PGM min 2s PGM PGM Configuration level PGM - pag.12 - Exit LB1312 Oilflam 700.1-800.1 PR/MD SETTING PARAMETERS When the burner is ignited all displays of the regulator light up. The set point display will blink for about 10 seconds. The value in the upper field of the display (red) indicates the actual value. The value in the lower field of the display (green) indicates the set point currently programmed. CHANGING THE SET POINT To change the set point, proceed as follows: - Press the PGM button to access the user level. SP1* will appear in the lower display - Change the value of set point SP1 using the t and s keys.▼e ▲. - After a 2 second delay the value set is stored automatically – To return to normal display press EXIT. EXIT * The value of SP1 depends on the value set previously in configuration level C111. SETTING PID PARAMETERS PID parameters are factory set to standard mean values. The operation of the regulator can be self-adapted to suit the system by activating the “tunE” function. The regulator will set the PID parameters automatically. To activate the “tunE” function proceed as follows: - With the burner in operation, press PGM + ▼. - the caption “tunE*” will blink in the display. – When “tunE” stops blinking, the self-adaptation routine has been completed. - Confirm the computed parameters by pressing the ▲ key for 2 seconds. * The “tunE” function cannot be activated in Manual mode, or when the burner is off. The PID parameters can be corrected manually from the parameters level, working on the proportional band Pb1, the derivative action time dt and the integral action time rt. To change parameters Pb1, dt and rt, proceeds as follows: - Press the PGM button to access the parameters level. - To move from one parameter to the next, press PGM . - When Pb1 is displayed, the value can be increased or decreased using the s and t keys. Confirm the changed parameters by pressing PGM. PGM - If confirmation is not given within 2 seconds the value will be stored automatically. - Press PGM to access the next parameter. - When dt is displayed, repeat the procedure described above. - Press PGM to access the next parameter. - When rt is displayed, repeat the procedure above. - To return to normal display press EXIT. EXIT DIFFERENTIAL SETTING FOR IGNITION AND SHUTOFF The regulator allows the selection of an adjustable switching differential that establishes burner ignition and shutoff values. HYS1 indicates the lower ignition limit, below which the regulator switches the burner to maximum power. HYS3 indicates the upper shutoff limit, above which the regulator switches the burner off. To set HYS1 and HYS3 proceed as follows: - Press the PGM key to access the parameters level. - To move from one parameter to the next, press PGM . - When HYS1 is displayed (burner ignition differential-stage II), increase or decrease the value using the ▼ and ▲ keys. - Confirm the changed parameters by pressing PGM. PGM - If confirmation is not given within 2 seconds the value will be stored automatically. - Press PGM to access the next parameter. - When HYS2 is displayed (burner shutoff differential-stage II), repeat the procedure described above. - Press PGM to access the next parameter. - When HYS3 is displayed (upper shutoff differential) repeat the procedure described above. - To return to normal display press EXIT. EXIT MANUAL/AUTOMATIC MODE To access “MANUAL” mode, press and hold EXIT for at least 5 seconds. Manual mode can only be selected when the burner is in operation. It is deactivated automatically when the burner shuts off. When the LED above the hand symbol is alight, the regulator is in manual mode and the position of the servocontrol can be changed using the ▼ and ▲ keys. The LEDS on the front of the regulator indicate whether the servocontrol OPEN or CLOSE command is currently active. Pressing the ▼ key the servocontrol OPENS. Pressing the ▲ key the servocontrol CLOSES. To select automatic mode press and hold EXIT for at least 5 seconds. The LED above the hand symbol goes out and the regulator reverts to automatic. CLIMATIC COMPENSATION The RWF 40 regulator can be set with the set point interlocked to the external probe. To select this operating mode, proceed as follows: - Connect the required probe as in the wiring diagram. - Change the regulator settings. When using an external probe the regulator must be set as follows: - Press the PGM key to access the configuration level. When the caption C111 (XXXX) is displayed, use the ▲ key to access the second figure (XXXX). Use the ▼ key to select the type of probe (XX3X). - Confirm the change of parameters by pressing PGM. PGM If this is not done within 2 seconds, the value is stored automatically - Press PGM to access the configuration level. When the display reads C112 (XXXX), use the ▲ key to access the second figure (XXXX). Press the ▼ key to set the type of probe (XX3X). - Confirm the changed parameters by pressing PGM. PGM - If confirmation is not given within 2 seconds the value will be stored automatically. - To return to normal display press EXIT. EXIT To establish the heating curve, proceed as follows: - Press PGM to access the parameters level. - Press PGM to move from one parameter to the next. - When the letter H is displayed (heating curve gradient), increase or decrease the value using the ▼ and ▲ keys. - Confirm the changed parameters by pressing PGM. PGM - If confirmation is not given within 2 seconds the value will be stored automatically. - To return to normal display press EXIT. EXIT - pag.13 - LB1312 Oilflam 700.1-800.1 PR/MD PARAMETERIZATION 160 Boiler temperature set point (iC) 140 120 100 SPH 80 60 SPL 40 Heating curve gradient (H) 4 3.8 3.6 3.4 3.2 3 2.8 2.6 2.4 2.2 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 20 0 15 20 17.5 10 12.5 0 5 7.5 2.5 -5 -2.5 -10 -7.5 -20 -15 -12.5 -17.5 External temperature (iC) PROBE CONNECTION DIAGRAMS Cod. S721 Connection for probe QAE2..(passive probe) Water probe Configuration code C111 = 9XXX Cod. S731 S731/1 S731/2 S731/3 S731/4 M1 1 2 3 4 B M QAE22A Cod. S704 G+ G- M1 U1 1 2 3 4 GL M U1 OBE620-P.. RWF 40 G1+ Cod. S720/1 RWF 40 Connection for probe FT-TP/..(passive probe) (Degusa probe) Configuration code C111 = 5XXX Connection for probe QBE620-P..(active probes) Configuration code C111 = GXXX S731 - 0…4 bar / 0…400 kPa QBE620-P4 S731/1 - 0…10 bar / 0…1 MPa QBE620-P10 S731/2 - 0…16 bar / 0…1.6 Mpa QBE620-P16 S731/3 - 0…25 bar / 0…2.5 MPa QBE620-P25 S731/4 - 0…40 bar / 0…4 MPa QBE620-P40 - pag.14 - Connection for probe QAC22 (passive probe) Configuration code C111 = XX3X C112 = XX1X RWF 40 B9 M9 1 2 3 4 B M QAC2.. LB1312 Oilflam 700.1-800.1 PR/MD C111 – C112 INPUT CONFIGURATION INDICATIONS Analog Input 3 (external temperature) No function (probe not active) 0 External probe Pt 1000, 2-wire, 1 QAC22 (passive probe) Analog input 1 (actual value) Pt1000, 2-wire, Landis & Staefa IEC 751 5 FT-TP/… (passive probe) Ni1000, 2-wire, Landis & Staefa QAE2 … (passive probe - water probe) 9 Standard Signal DC 0…10 V QBE620P… (active probe - pressure probe) G AUXILIARY CONTACT, TYPE OF REGULATOR, SET POINT “SP1” BLOCK C112. Parameter configuration Set point “SP1” Set point SP1 - data input from keys Set point SP1 - interlocked to external probe (configure) 0 1 ERROR/FAULT INDICATION NUMBERS BLINKING IN DISPLAY - Situation - The number 1999 blinks in the display as the actual value, with the set point value displayed normally. - Cause - The real value is not being measured. This means that the upper or lower - limit of the measurement range on analog input 1 (real value) has been exceeded. Remedy - Check the electrical connections and the state of the probe. If the probe is faulty, the regulator will not indicate the real value of the physical quantity monitored. This will result in automatic shutdown (failsafe), deactivation of the self-adapt function and inhibition of manual operation. The response of the auxiliary contact will depend on the configuration of parameter C113. - Situation - The number 1999 blinks in the display as the actual value, with tA showing in the set point field. - Cause - The external temperature is not being measured. This means that the - upper or lower limit of the measurement range on analog input 3 (real value) has been exceeded. Remedy - Check the electrical connections and the state of the probe. If the probe is faulty, the regulator will not indicate the real value. - Situation - The number 1999 blinks in the display as the actual value, with SP .E - showing in the set point field. Cause - The external set point value is not being measured. This means that the upper or lower limit of the measurement range on analog input 2 (real value) has been exceeded. Remedy - Check the electrical connections and the external set point signal. If the probe is faulty, the regulator will not indicate the real value of the physical quantity monitored. This will result in automatic shutdown (failsafe), deactivation of the self-adapt function and inhibition of manual operation. - pag.15 - LB1312 Oilflam 700.1-800.1 PR/MD WHEN REPLACEMENT IS NECESSARY, PROCEED AS SHOWN IN FIGURES A-B-C BELOW A B Insert the RWF 40 regulator through the relative opening in the electrical panel (A). Insert the fixing anchors and screws into the slots, and secure the unit to the panel (B). To open the regulator, squeeze the cover from the ends as shown, and lift out (C). - pag.16 - C LB1312 Oilflam 700.1-800.1 PR/MD PARAMETERS Parameter Limit value of limit comparator Switching differential for limit comparator Proportional band Derivative time Integral action time Dead band (neutral zone) Actuator running time (sec.) Switch-on threshold burner / stage II Switch-off level stage II Upper switch-off threshold Response threshold Heating curve slope Parallel displacement Display AL HYSt Pb.1 dt rt db tt HYS1 HYS2 HYS3 q H P Ecoflam setting (passive probe) QAE22 0 0 8 20 80 0.5 25 -2 0 5 0 2 0 Ecoflam setting (passive probe) FT-TP/1000 0 0 8 20 80 0.5 25 -2 0 5 0 2 0 Ecoflam setting (active probe) QBE620-P... 0 0 1 3 15 0.5 25 -0.2 0 0.5 0 2 0 CONFIGURATION Parameter Analog input 1, 2 and 3; setpoint changeover / shift Limit comparator; controller type; setpoint 1; locking Unit address; decimal place / unit, signal for out-of-range Measured value range start analog input 1 Measured value range analog input 1 Measured value range analog input 2 Measured value range analog input 2 Lower setpoint limit Upper setpoint limit Actual value correction,analog input 1 Actual value correction,analog input 2 Actual value correction,analog input 3 Filter time constant for digital filter, analog input 1 Display Ecoflam setting (passive probe) (active probe) QBE620-P... QAE22 FT-TP/1000 -P4 -P10 -P16 -P25 -P40 C111 9030 5030 G000 G000 G000 G000 G000 C112 0010 0010 0010 0010 0010 0010 0010 C113 0110 0110 0110 0110 0110 0110 0110 SCL 0 0 0 0 0 0 0 SCH 100 100 4 10 16 25 40 SCL2 0 0 0 0 0 0 0 SCH2 SPL SPH OFF1 OFF2 OFF3 dF1 0 60 88 0 0 0 1 0 60 88 0 0 0 1 0 0 4 0 0 0 0 0 0 10 0 0 0 0 0 0 16 0 0 0 0 0 0 25 0 0 0 0 0 0 40 0 0 0 0 - pag.17 - COMUNICARE A TERZI IL CONTENUTO DEL PRESENTE. A TERMINE DI LEGGE E' VIETATO RIPRODURRE O PROPRIETA' RISERVATA DELLA DITTA ECOFLAM S.p.A. E D C B A IND.MOD. SOST.DA SOST.IL R S 00 SAL FU LINE LOAD T NO DATA-FIRMA FMV KMV Z S 01 HLBT FMV R 98 97 T NO FIRMA KMRLA S T NO CONTROLLATO DISEGNATO DESCRIZIONE MODIFICA N T S R PE N T S R PE FU R 02 KMRLI 1 02 DATA 01 50 Hz 400 V 50 Hz 400 V - pag.18 R S T 24-01-2005 03-10-2003 Q N Q R S T HLR FIRMA 00 N S T NO 03 U1 V1 W1 R R 03 S T R1 S1 KMRLI 2 T STS T P P T2 N 5 6 7 8 HLB 9 10 04 UFF.TECNICO-SETTORE ELETTRICO STC T1 R2 S2 05 15 S.p.A. 11 12 13 14 M 31 32 33 34 35 39 40 41 CONTROLLO DI TENUTA 36 37 38 07 A B C 11 12 23 24 SIST. RIVELAZ. POTENZIOMENTRO DEL MOTORIDUTTORE CONSENSI PREOVENIENTI DAL GEFRAN 600 9 10 21 22 1 2 3 4 6 5 19 20 05 LANDIS LAL 1.25 06 UV 08 BEM27070/A CODICE 29 30 KA3 KA2 LANDIS SQM 50.481A2 26 27 28 HLF FMV APPARECCHIATURA 25 96 95 OILFLAM 700.1 MD U1 21 22 23 24 08 MOTORIDUTTORE QBE620-P GL 19 20 07 LANDIS LAL 1.25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 31 32 06 DENOMINAZIONE SA 16 17 18 L N Q Y1 Y2 Q13 Q14 G+ G- M1 U1 G1+ B9 M9 LANDIS RWF 40 04 1 2 3 09 IND.MODIFICA RELASE 9.0 0 SAMA 09 E D C B A LB1312 Oilflam 700.1-800.1 PR/MD DATA COMUNICARE A TERZI IL CONTENUTO DEL PRESENTE. E D C B A U1 SOST.DA SOST.IL IND.MOD. MV 3 M V1 00 DATA-FIRMA W1 U1 V1 W1 R 01 FIRMA A TERMINE DI LEGGE E' VIETATO RIPRODURRE O PROPRIETA' RISERVATA DELLA DITTA ECOFLAM S.p.A. 01 S R T R1 S1 S R1 S1 T2 N T1 R2 CONTROLLATO DISEGNATO DESCRIZIONE MODIFICA T1 R2 S2 T 02 S2 02 T2 DATA 10 11 12 13 14 24-01-2005 03-10-2003 9 15 TC tipo J + - pag.19 FIRMA - 00 16 03 03 23 24 25 29 30 31 32 33 34 04 UFF.TECNICO-SETTORE ELETTRICO 26 27 28 04 M 06 ASZ... 35 S.p.A. 39 40 41 RA RA B C A YVO1 07 LANDIS SQM 50.481A2 I 0 II III 0 IV V 0 VI VII 0 VIII P 05 06 B 08 BEM27070/B CODICE RELASE 8.0 TV LANDIS SQM 50.481A2 P APPARECCHIATURA T STmr MOTORIDUTTORE SIST. RIVELAZ. T STR I: CAMMA DI REGOLAZIONE ARIA ALTA FIAMMA LAVORO II: CAMMA REGOLAZIONE ARIA DI MINIMA FIAMMA III: CAMMA REGOLAZIONE ARIA BASSA FIAMMA IV: NON UTILIZZATA V: NON UTILIZZATA VI: NON UTILIZZATA 0 OILFLAM 700.1 MD CONTROLLO DI TENUTA M 09 09 IND.MODIFICA B N 11 1 21 12 2 22 13 3 23 14 4 24 15 5 25 16 6 26 17 7 27 1 08 DENOMINAZIONE 07 POTENZIOMENTRO DEL MOTORIDUTTORE CONSENSI PREOVENIENTI DAL YVGPS THE WIRING CABLE TO THE ELECTRICAL BOARD MUST BE MADE BY COMPENSATED CABLE WITH MINIMUM SECTION 1,5mm2 MAXIMUM ALLOWED LENGTH 50m. ATTENZION: LUNGHEZZA MASSIMA CONSENTITA 50m IL CAVO DI COLLEGAMENTO AL QUADRO DEVE ESSERE DI TIPO COMPENSATO CON SEZ. MINIMA 1.5mm2 ATTENZIONE: 36 37 38 RP YVGP N 11 1 21 12 2 22 13 3 23 14 4 24 15 5 25 16 6 26 17 7 27 A B C 1 LANDIS SQM 50.481A2 05 E D C B A LB1312 Oilflam 700.1-800.1 PR/MD DATA COMUNICARE A TERZI IL CONTENUTO DEL PRESENTE. A TERMINE DI LEGGE E' VIETATO RIPRODURRE O PROPRIETA' RISERVATA DELLA DITTA ECOFLAM S.p.A. E D C B A SOST.DA SOST.IL IND.MOD. 00 DATA-FIRMA FIRMA 01 CONTATTORE RESISTENZE DI LAVORO WORKING RESISTOR SWITCH INTERRUPTEUR DES RESISTANCES DE TRAVAIL INTERRUFTOR DE LAS RESISTENCIAS DE TRABAJIO KMRLA TERMOSTATO CALDAIA BOILER THERMOSTAT THERMOSTAT CHAUDIERE TERMOSTATO CALDERA STC COMMUTATORE MANUALE-AUTOMATICO SWITCH (MANUAL-AUTOMATIC)) INTERRUPTEUR MANUEL-AUTOMATIQUE CONMUTADOR MANUAL-AUTOMATICO INTERRUTTORE DI LINEA WORKING SWITCH INTERRUPTEUR DE LIGNE INTERRUPTOR DE LINEA SAL SAMA RELE' RELAY RELAIS RELE' KA3 LAMPADA DI BLOCCO TERMICO THERMAL LOCK-OUT LAMP LAMPE DE THERMAL DE SECURITE ESPIA DE BLOQUEO RELE TERMICO RELE' RELAY RELAIS RELE' KA2 HLBT RELE' RELAY RELAIS RELE' KA1 TERMOSTATO DI SICUREZZA SAFETY THERMOSTAT THERMOSTAT DE SECURITE TERMOSTATO DE SEGURIDAD LAMPADA RESISTENZE RESISTOR LAMP TEMOIN RESISTENCES INDICADOR RESISTENCIAS HLR 01 STS LAMPADA DI FUNZIONAMENTO WORKING LAMP LAMPE DE FONCTIONNEMENT ESPIA DE FUNCIONAMIENTO HLF FUSIBILE FUSE FUSIBLE FUSIBLE FU LAMPADA DI BLOCCO LOCK-OUT LAMP LAMPE DE SECURITE ESPIA DE BLOQUEO MOTORE VENTILATORE MOTOR FAN MUTEUR VENTILATEUR MOTOR VENTILADOR MV HLB FILTRO ANTIDISTURBO ANTJAMMING FILTER FILTRE ANTIPARASITES FILTRO DE PROTECION ANTIDISTURBIO Z RELE' TERMICO MOTORE VENTILATORE MOTOR THERMAL RELAY (FAN MOTOR) RELAIS THERMIQUE MOTEUR VENTILATEUR RELE' TERMICO MOTOR VENTILADOR INTERRUTTORE GENERALE CON FUSIBILE MAIN SWITCH WITH FUSE INTERRUPTEUR GENERAL AVEC FUSIBLE INTERRUPTOR GENERAL CON FUSIBLE Q FMV FOTORESISTENZA PHOTO-RESISTOR PHOTORESISTANCE FOTORESISTENCIA DATA - pag.20 - CONTROLLATO DISEGNATO DESCRIZIONE MODIFICA 02 02 ELETTROVALVOLA OLIO DI PRIMA FIAMMA FIRST STAGE HEAVY OIL SOLENOID VALVE ELECTROVANNE 1? ALLURE ELECTROVALVULA FUEL PESADO DE 1^ LLAMA YVO1 12-11-2003 03 TERMOSTATO DI RITORNO RETURN TERMOSTAT STmr 04 04 UFF.TECNICO-SETTORE ELETTRICO TERMOSTATO DI SICUREZZA RESISTENZE RESTOR SAFETY TERMOSTAT TERMOSTAT DE SECURITE RESISTANCES TERMOSTATO DE SEGURIDAD RESISTENCIAS STR 03-10-2003 PRESSOSTATO ARIA AIR PRESSURE SWITCH PRESSOSTAT AIR PRESOSTATO AIRE TRASFORMATORE IGNITION TRANSFORMER TRANSFORMATEUR D'ALLUMAGE TRANSFORMADOR RESISTENZA POMPA PUMP RESISTOR RESISTANCE POMPE RESISTENCIA BOMBA RESISTENZA AUSILIARIA AUXILIARY RESISTOR RESISTANCE AUXILIAIRE RESISTENCIA AUXILIARIA RESISTENZA AUSILIARIA AUXILIARY RESISTOR RESISTANCE AUXILIAIRE RESISTENCIA AUXILIARIA CONTATTORE RESISTENZE DI LIVELLAMENTO LEVELLING RESISTOR SWITCH INTERRUPTEUR DES RESISTANCES DE NIVELLEMENT INTERRUFTOR DE LAS RESISNCIAS DE NIVELACION CONTATTORE RESISTENZE DI LIVELLAMENTO LEVELLING RESISTOR SWITCH INTERRUPTEUR DES RESISTANCES DE NIVELLEMENT INTERRUFTOR DE LAS RESISNCIAS DE NIVELACION ELETTROVALVOLA GAS PILOTA DI SICUREZZA EXTRA SAFETY PILOT SOLENOID GAS VALVE ELECTROVANNE GAZ PILOTE DE SICURITE ELECTROVALVULA GAS PILOTO DE SEGURIDAD ELETTROVALVOLA GAS PILOTA PILOT FLAME SOLENOID GAS VALVE ELECTROVANNE GAZ PILOTE ELECTROVALVULA GAS PILOTO 03 SPA TV RP RA RA KMRLI 2 KMRLI 1 YVGPS YVGP FIRMA B 00 S.p.A. 07 05 06 CODICE 08 BEM27070/C LANDIS SQM 50.481A2 APPARECCHIATURA SIST. RIVELAZ. MOTORIDUTTORE 08 OILFLAM 700 MD 07 OUT 4:TERMOSTATO DI ACCENSIONE OUT 3:KMRLI 2 OUT 2:KMRLI 1 OUT 1:KMRLA USCITE RELE DEL REGOLATORE CONTROLLO DI TENUTA 06 DENOMINAZIONE 05 09 09 IND.MODIFICA E D C B A LB1312 Oilflam 700.1-800.1 PR/MD DATA 6 0 15 30 75 90 - pag.21 - 19 21 22 0 OIL I 0 12 11 AUTO 10 RESET 16 RWF 40 PGM 17 Gefran EXIT K6 13 15 18 D FIN DER FIN 69 8 25 68 14 9 66 26 67 27 61 29 60 28 62 30 57 37 0 15 30 45 75 20 23 24 70 32 7 54 55 59 56 63 51 OILFLAM 700.1 - 800.1 PR/MD 64 4 65 5 3 31 38 58 2 71 42 53 1 39 73 40 72 36 35 46 52 44 41 45 43 47 33 34 48 49 50 LB1312 Oilflam 700.1-800.1 PR/MD 60 90 LB1312 Oilflam 700.1-800.1 PR/MD N° OILFLAM 700.1 MD DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 - PUMP HEATING ELEMENT PUMP HOSES COIL CONETTORE BOBINA MANOMETER COVER GLASS PEEP WINDOW FRAME MOTOR CONTROL BOX BASE CONTROL BOX RELAY RELAY BASE REMOTE CONTROL SWITCH 16 17 18 19 20 21 22 23 24 - REMOTE CONTROL SWITCH MOTOR MOTOR THERMAL RELAY ANTIJAMMING FILTER ADJUSTMENT OF FUEL TEMPERATURE MAIN SWITCH MANUAL / AUTOMATIC SELECTOR RESET SWITCH FUSE HOLDER LAMP 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 - PLUG WIELAND IGNITION TRANSFORMER PHOTORESISTOR FAN AIR CONVEYOR RING COVER AIR INLET AIR DAMPER MOTOR THERMOCOUPLE FILTER HEATER OIL TANK CABLE RING HOLDER SPRING FIRING HEAD PIPE STAFFA SUPPORTO TESTA ROD NOZZLE HOLDER HOLDER WAISTBAND WAISTBAND ELECTRODES SUPPORT NOZZLE HOLDER NOZZLE HOLDER NOZZLE DIFFUSER BLAST TUBE BLAST TUBE END ASSEMBLY FIRING HEAD GASKET GASKET GASKET SILENCER FILTER code SUNTEC TA5C30106 50 W 25 x1500 EL011 EL011 15000 W LANDIS LAL1.25 LANDIS LAL1.25 Tv22" 4 4 BF40.00 BF40.00 BF16.10NA LovatoRF95 20-33A GEFRAN 600 cod.40100I1509 319017030SGREEN 319010010S RED BRAHMA T8 LANDIS RU-560 M.d.42 SQM50.481A2 TC6MD2JBC U21008/01 30 kW P148/2 R110 S901/2 V523 V1119/07 S601/1 BFC04262/038 BFC02004 BFC02006 M170/3 A413 A147 R712 R906 R616 R616 R617/1 R510/7 S132/4 E1216 R1020 R1020/5 E1507/2 E1507 E222 T101 A207/1 BFV10404/001 BFC08261 BFC08258/038 GRCA630 M212/91 E1216/1 S107/7 R127 BFP01041/017 BFE01403/3 BFT15224/001 BFT15222/001 BFT15226 BFT15221/001 TC BFT15220 BFC10034 BFT15219 E612/1 BFC10033 BFC11019 BFD05030 BFB08001/017 BFB08002 70501/03 - pag.22 - BFG04062 BFG04060 BFG04061 BAA11001 S107/5 LB1312 Oilflam 700.1-800.1 PR/MD N° 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 OILFLAM 700.1 MD DESCRIPTION - code ROD COUPLING (FAN) UNION (FAN) COUPLING COUPLING UNION (PUMP) COUPLING (PUMP) GAS VALVE COIL GAS VALVE COIL MODULATING UNIT PREHEATED’S AUX. RESISTOR HOLDER FIXING PLATE HEATING ELEMENT BRAHMA EG12S BRAHMA EG12S BRAHMA EG12SR BRAHMA EG12SR RWF 40.000A97 50 W TC = SHORT HEAD TL = LONG HEAD - pag.23 - BFT05113/001 BFV10220 BFV10203/4 BFV10203/3 BFV10201/1 BFV10201/6 BFV10201/2 V142 V142/1 E1215 BFT15215/1 BFT15215/2 R110 DESIGN AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE La ECOFLAM S.p.A si riserva il diritto di apportare ai prodotti quelle modifiche che riterrà necessarie o utili, senza pregiudicarne le caratteristiche principali. Ecoflam S.p.A. via Roma, 64 - 31023 RESANA (TV) - Italy - tel. 0423/715345 r.a. telefax 0423-715444 (Italy 480009 - Export 480873, 715538). http://www.ecoflam.it - e-mail: [email protected]
Documentos relacionados
maior p 150.1 pr maior p 200.1 pr oil burners
with oil flow regulation on its return pipe. The oil supply is varied by acting on the nozzle through the pressure in the return line. Max. oil supply is therefore reached when the pressure in the ...
Leia mais