SIRIUS M200D

Transcrição

SIRIUS M200D
SIRIUS M200D
Supplementary products
Release 01/2012
M200D
Supplementary products
Order note:
The articles and order numbers listed in this catalogue are special numbers, which were created
within the context of the partnership between Siemens and HARTING. Order processing is only
possible within the framework of this partnership for the Siemens product range.
Prices (UPE) at this Catalogue are recommended sales prices.
A binding quotation with your conditions you will receive via your responsible HARTING
subsidiary company.
Send your inquiry to:
Contact and delivery address:
HARTING Deutschland GmbH & Co. KG
For technical questions:
mailto:[email protected]
mailto:[email protected]
Heike Sielaff
Tel. +49 571 8896-223
Simeonscarré 1
32427 Minden
Germany
Andreas Scheuer
Tel. +49 571 8896-263
Edition 01/2012
Page 2
Sven Wessel
Tel. +49 571 8896-335
M200D
Supplementary products
SIRIUS M200D
Table of contents
1
Energy – Connection ------------------------------------------------------------------------------- 5
1.1
Energy T-terminal connector --------------------------------------------------------------------- 5
1.2
Energy T-connector for power bus max. 25mm² --------------------------------------------- 6
1.3
Energy double T-terminal connector ------------------------------------------------------------ 6
1.4
Power bus cable -------------------------------------------------------------------------------------- 7
1.4.1
Power bus cable (sold by ring) 2,5mm² --------------------------------------------------- 7
1.4.2
Power bus cable (sold by ring) 4,0mm² --------------------------------------------------- 7
1.4.3
Power bus cable (sold by ring) 6,0mm² --------------------------------------------------- 7
2
Power cable ------------------------------------------------------------------------------------------ 8
2.1
Power cables for motor starter M200D prefabricated --------------------------------------- 8
2.1.1
Cross section 2,5mm², w/o N-Conductor ------------------------------------------------- 8
2.1.1.1 Cross section 2,5mm², with N-Conductor --------------------------------------------- 8
2.1.2
Cross section 4,0mm², w/o N-Conductor ------------------------------------------------- 9
2.1.2.1 Cross section 4,0mm², with N-Conductor --------------------------------------------- 9
2.1.3
Cross section 6,0mm², w/o N-Conductor ------------------------------------------------- 9
2.1.3.1 Cross section 6,0mm², with N-Conductor --------------------------------------------- 9
2.2
Power cables for motor starter M200D one-sided prefabricated -------------------------- 10
2.2.1
Cross section 2,5mm², w/o N-Conductor ------------------------------------------------ 10
2.2.1.1 Cross section 2,5mm², with N-Conductor -------------------------------------------- 10
2.2.2
Cross section 4mm² without N-Conductor ---------------------------------------------- 11
2.2.2.1 Cross section 4mm² with N-Conductor ----------------------------------------------- 11
2.2.3
Cross section 6mm² without N-Conductor ---------------------------------------------- 11
2.2.3.1 Cross section 6mm² mit N-Leiter ------------------------------------------------------ 11
2.3
Power cable (sold by the ring) ------------------------------------------------------------------- 12
2.3.1
Power cables (sold by the ring) 2,5mm², w/o N-Conductor ------------------------- 12
2.3.1.1 Power cables (sold by the ring) 2,5mm², with N-Conductor --------------------- 12
2.3.2
Power cables (sold by the ring) 4,0mm², w/o N-Conductor ------------------------- 12
2.3.2.1 Power cables (sold by the ring) 4,0mm², with N-Conductor --------------------- 12
2.3.3
Power cables (sold by the ring) 6,0mm², w/o N-Conductor ------------------------- 12
2.3.3.1 Power cables (sold by the ring) 6,0mm², with N-Conductor --------------------- 12
2.4
Connector set for power cable ------------------------------------------------------------------- 13
3
Motor connection ----------------------------------------------------------------------------------14
3.1
Motor cable for motors in star connection, prefabricated ---------------------------------- 14
3.1.1
Without Brake, without Temperature transmitter -------------------------------------- 14
3.1.1.1 Cross section 1,5mm² -------------------------------------------------------------------- 14
3.1.1.2 Cross section 2,5mm² -------------------------------------------------------------------- 15
Edition 01/2012
Page 3
M200D
Supplementary products
3.1.2
With Brake (Brake voltage 400VAC or 180VDC), w/o Temperature transmitter
15
3.1.2.1 Cross section 1,5mm² -------------------------------------------------------------------- 15
3.1.2.2 Cross section 2,5mm² -------------------------------------------------------------------- 15
3.1.3
With Brake (Brake voltage 230VAC), w/o Temperature transmitter -------------- 16
3.1.3.1 Cross section 1,5mm² -------------------------------------------------------------------- 16
3.1.3.2 Cross section 2,5mm² -------------------------------------------------------------------- 16
3.1.4
With Brake (Brake voltage 400VAC or 180VDC), with Temperature transmitter
16
3.1.4.1 Cross section 1,5mm² -------------------------------------------------------------------- 16
3.1.4.2 Cross section 2,5mm² -------------------------------------------------------------------- 17
3.1.5
With Brake (Brake voltage 230VAC), with Temperature transmitter ------------- 17
3.1.5.1 Cross section 1,5mm² -------------------------------------------------------------------- 17
3.1.5.2 Cross section 2,5mm² -------------------------------------------------------------------- 17
3.2
Motor cable for motors in star connection, one-sided prefabricated --------------------- 18
3.2.1
Without Brake, without Temperature transmitter -------------------------------------- 18
3.2.1.1 Cross section 1,5mm² -------------------------------------------------------------------- 18
3.2.1.2 Cross section 2,5mm² -------------------------------------------------------------------- 18
3.2.2
With Brake (Brake voltage 400VAC or 180VDC), w/o Temperature transmitter
19
3.2.2.1 Cross section 1,5mm² -------------------------------------------------------------------- 19
3.2.2.2 Cross section 2,5mm² -------------------------------------------------------------------- 19
3.2.3
With Brake (Brake voltage 230VAC), w/o Temperature transmitter -------------- 19
3.2.3.1 Cross section 1,5mm² -------------------------------------------------------------------- 19
3.2.3.2 Cross section 2,5mm² -------------------------------------------------------------------- 19
3.2.4
With Brake (Brake voltage 400VAC or 180VDC), with Temperature transmitter
20
3.2.4.1 Cross section 1,5mm² -------------------------------------------------------------------- 20
3.2.4.2 Cross section 2,5mm² -------------------------------------------------------------------- 20
3.2.5
With Brake (Brake voltage 230VAC), with Temperature transmitter ------------- 20
3.2.5.1 Cross section 1,5mm² -------------------------------------------------------------------- 20
3.2.5.2 Cross section 2,5mm² -------------------------------------------------------------------- 20
3.3
Motor cable - sold by the ring ------------------------------------------------------------------- 21
3.3.1
Motor cable 1,5mm² - sold by the ring --------------------------------------------------- 21
3.3.2
Motor cable 2,5mm² - sold by the ring --------------------------------------------------- 21
3.4
Set of connector for motor connection cable, on the side of the motor starter (M200D)
22
3.5
Sets of connectors on the side of the motor --------------------------------------------------- 23
4
Accessories ------------------------------------------------------------------------------------------24
4.1
4.2
4.3
4.4
Set of connectors for power bus switching cabinet / subdistributor --------------------- 24
Protective cover ------------------------------------------------------------------------------------- 25
Crimping tool---------------------------------------------------------------------------------------- 25
Dismantle tool for male and female inserts---------------------------------------------------- 25
Technical Datasheets
Page 27 – 63
Index list of products
Page 65 – 66
List of HARTING Subsidiary Companies
Page 67
Edition 01/2012
Page 4
M200D
Supplementary products
1 Energy – Connection
1.1
Energy T-terminal connector
Order Number
HTG:61 88 201 0500
HTG:61 88 201 0501
HTG:61 88 201 0502
HTG:61 88 201 0503
HTG:61 88 201 0504
HTG:61 83 401 0200
HTG:61 83 401 0201
HTG:61 83 401 0202
HTG:61 83 401 0203
HTG:61 83 401 0204
Edition 01/2012
Page 5
Description
Energy T-terminal connector for power bus
cable from 2,5mm² up to 4mm²
With built-in 7-pole connector, female insert,
hood, UL
Energy T-terminal connector for power bus
cable from 4mm² up to 6mm²
With built-in 7-pole connector, female insert,
hood, UL
Energy T-terminal connector
Length 2,5m and 7-pole connector, female
insert, hood,
for power bus cable from 2,5mm² till 4mm²
with connected cable 5 x 2,5mm²
for power bus cable from 4mm² till 6mm²
with connected cable 5 x 4mm²
for power bus cable from 4mm² till 6mm²
with connected cable 5 x 6mm²
Sealing for cable 10 – 13mm
1set =2 pieces
Sealing for cable 13 – 16mm
1set =2 pieces
Sealing for cable 16 – 19mm
1set =2 pieces
Sealing for cable 19 – 22mm
1set =2 pieces
Sealing blind grommet
1 piece
UPE €
32,22
32,22
45,95
49,15
53,92
1,38
1,38
1,38
1,38
0,88
M200D
Supplementary products
1.2
Energy T-connector for power bus max. 25mm²
Han Q4/2
Order Number
HTG:61 88 201 0181
1.3
Description
Energy T-terminal connector for power bus
cable up to 25mm²
for power bus cross sectional change or power
bus extension
Glands M25 for cable cross section from
13 mm up to 18 mm
With built-in 7-pole connector, female insert,
hood
UPE €
70,22
Energy double T-terminal connector
Seal
2xHAN Q4/2-Female
Order Number
HTG: 61 88 202 0770
HTG:09 12 000 9970SI
HTG:09 12 000 9971SI
HTG:09 12 000 9972SI
HTG:09 12 000 9973SI
HTG:09 12 000 9974SI
Edition 01/2012
Page 6
Description
Energy double T-terminal connector for bus
cable from 4mm² up to 6mm²
With two built-in 7-pole connector, female
insert, hood, UL
Sealing for cable 10 – 13mm
1set =2 pieces
Sealing for cable 13 – 16mm
1set =2 pieces
Sealing for cable 16 – 19mm
1set =2 pieces
Sealing for cable 19 – 22mm
1set =2 pieces
Sealing blind grommet
1 piece
UPE €
51,73
1,38
1,38
1,38
1,38
1,38
M200D
Supplementary products
1.4
Power bus cable
1.4.1 Power bus cable (sold by ring) 2,5mm²
Order Number
HTG:61 88 600 0101
HTG:61 88 600 0102
on request
Description
Power bus cable, 5x2,5mm²
Length 50m
Length 100m
Length >100m
UPE €
220,52
426,10
1.4.2 Power bus cable (sold by ring) 4,0mm²
Order Number
HTG:61 88 600 0107
HTG:61 88 600 0108
on request
Description
Power bus cable, 5x4,0mm²
Length 50m
Length 100m
Length >100m
UPE €
312,02
609,03
1.4.3 Power bus cable (sold by ring) 6,0mm²
Order Number
HTG:61 88 600 0113
HTG:61 88 600 0114
on request
Edition 01/2012
Page 7
Description
Power bus cable, 5x6,0mm²
Length 50m
Length 100m
Length >100m
UPE €
450,37
885,77
M200D
Supplementary products
2 Power cable
2.1
Power cables for motor starter M200D prefabricated
HanQ 4/2 Housing
(with bracket)
male insert
HanQ 4/2
Hood, side entry
female insert
Power cable
2.1.1 Cross section 2,5mm², w/o N-Conductor
Order number
HTG:61 88 202 0400
HTG:61 88 202 0401
HTG:61 88 202 0402
HTG:61 88 202 0403
Description
Power cable for M200D
HAN Q4/2 top entry - HAN Q4/2 side entry
4x2,5mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
43,93
50,09
58,29
78,81
2.1.1.1 Cross section 2,5mm², with N-Conductor
Order number
HTG:61 88 202 0693
HTG:61 88 202 0694
HTG:61 88 202 0695
HTG:61 88 202 0696
Edition 01/2012
Page 8
Description
Power cable (N) for M200D
HAN Q4/2 top entry - HAN Q4/2 side entry
5x2,5mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
45,78
52,53
62,80
83,23
M200D
Supplementary products
2.1.2 Cross section 4,0mm², w/o N-Conductor
Order number
HTG:61 88 202 0404
HTG:61 88 202 0405
HTG:61 88 202 0406
HTG:61 88 202 0407
Description
Power cable for M200D
HAN Q4/2 top entry - HAN Q4/2 side entry
4x4,0mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
46,91
55,86
67,76
97,57
2.1.2.1 Cross section 4,0mm², with N-Conductor
Order number
HTG:61 88 202 0697
HTG:61 88 202 0698
HTG:61 88 202 0699
HTG:61 88 202 0700
Description
Power cable (N) for M200D
HAN Q4/2 top entry - HAN Q4/2 side entry
5x4,0mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
52,13
64,35
81,60
126,54
2.1.3 Cross section 6,0mm², w/o N-Conductor
Order number
HTG:61 88 202 0408
HTG:61 88 202 0409
HTG:61 88 202 0410
HTG:61 88 202 0411
Description
Power cable for M200D
HAN Q4/2 top entry - HAN Q4/2 side entry
4x6,0mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
51,77
64,83
82,27
125,82
2.1.3.1 Cross section 6,0mm², with N-Conductor
Order number
HTG:61 88 202 0701
HTG:61 88 202 0702
HTG:61 88 202 0703
HTG:61 88 202 0704
Edition 01/2012
Page 9
Description
Power cable (N) for M200D
HAN Q4/2 top entry - HAN Q4/2 side entry
5x6,0mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
53,93
68,73
88,45
135,67
M200D
Supplementary products
2.2
Power cables for motor starter M200D
one-sided prefabricated
End open
HanQ 4/2
Hood, side entry
female insert
Power cable
2.2.1 Cross section 2,5mm², w/o N-Conductor
Order number
HTG:61 88 201 0192
HTG:61 88 201 0193
HTG:61 88 201 0194
HTG:61 88 201 0195
Description
Power cable for M200D
open - HAN Q4/2 side entry
4x2,5mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
25,63
31,57
39,78
60,28
2.2.1.1 Cross section 2,5mm², with N-Conductor
Order number
HTG:61 88 201 0458
HTG:61 88 201 0459
HTG:61 88 201 0460
HTG:61 88 201 0461
Edition 01/2012
Page 10
Description
Power cable (N) for M200D
open - HAN Q4/2 side entry
5x2,5mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
27,19
34,46
44,27
67,95
M200D
Supplementary products
2.2.2 Cross section 4mm² without N-Conductor
Order number
HTG:61 88 201 0196
HTG:61 88 201 0197
HTG:61 88 201 0198
HTG:61 88 201 0199
Description
Power cable for M200D
open - HAN Q4/2 side entry
4x4,0mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
27,88
34,94
44,67
69,02
2.2.2.1 Cross section 4mm² with N-Conductor
Order number
HTG:61 88 201 0462
HTG:61 88 201 0463
HTG:61 88 201 0464
HTG:61 88 201 0465
Description
Power cable (N) for M200D
open - HAN Q4/2 side entry
5x4,0mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
30,08
40,31
55,06
91,91
2.2.3 Cross section 6mm² without N-Conductor
Order number
HTG:61 88 201 0200
HTG:61 88 201 0201
HTG:61 88 201 0202
HTG:61 88 201 0203
Description
Power cable for M200D
open - HAN Q4/2 side entry
4x6,0mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
31,59
42,02
56,40
92,31
2.2.3.1 Cross section 6mm² mit N-Leiter
Order number
HTG:61 88 201 0466
HTG:61 88 201 0467
HTG:61 88 201 0468
HTG:61 88 201 0469
Edition 01/2012
Page 11
Description
Power cable (N) for M200D
open - HAN Q4/2 side entry
5x6,0mm²
Length 1,5m
Length 3m
Length 5m
Length 10m
UPE €
35,57
48,08
65,96
106,60
M200D
Supplementary products
2.3
Power cable (sold by the ring)
2.3.1 Power cables (sold by the ring) 2,5mm², w/o N-Conductor
Order number
HTG:61 88 600 0115
HTG:61 88 600 0116
on request
Description
Power cable 4x2,5mm²
Length 50m
Length 100m
Length >100m
UPE €
175,77
353,32
2.3.1.1 Power cables (sold by the ring) 2,5mm², with N-Conductor
Order number
HTG:61 88 600 0101
HTG:61 88 600 0102
on request
Description
Power cable 5x2,5mm²
Length 50m
Length 100m
Length >100m
UPE €
220,52
426,10
2.3.2 Power cables (sold by the ring) 4,0mm², w/o N-Conductor
Order number
HTG:61 88 600 0117
HTG:61 88 600 0118
on request
Description
Power cable 4x4,0mm²
Length 50m
Length 100m
Length >100m
UPE €
241,79
468,64
2.3.2.1 Power cables (sold by the ring) 4,0mm², with N-Conductor
Order number
HTG:61 88 600 0107
HTG:61 88 600 0108
on request
Description
Power cable 5x4,0mm²
Length 50m
Length 100m
Length >100m
UPE €
312,01
609,03
2.3.3 Power cables (sold by the ring) 6,0mm², w/o N-Conductor
Order number
HTG:61 88 600 0119
HTG:61 88 600 0120
on request
Description
Power cable 4x6mm²
Length 50m
Length 100m
Length >100m
UPE €
349,05
683,11
2.3.3.1 Power cables (sold by the ring) 6,0mm², with N-Conductor
Order number
HTG:61 88 600 0113
HTG:61 88 600 0114
on request
Edition 01/2012
Page 12
Description
Power cable 5x6mm²
Length 50m
Length 100m
Length >100m
UPE €
450,37
885,77
M200D
Supplementary products
2.4
Connector set for power cable
HanQ 4/2 Housing
(with bracket)
Male insert
Power supply cable
Order number
HTG:61 04 401 0556
HTG:61 04 401 0545
HTG:61 04 401 0550
HTG:61 04 401 0502
Edition 01/2012
Page 13
HanQ 4/2
Hood side entry
Female insert
Top down
Description
Set of connectors power cable
e.g. for connection to the T-terminal connector
consisting of housing, outgoing circuit top entry
(with bracket)
Male insert for Han Q4/2, UL
Gland for cable size
11,5 – 15,5 mm
5 male contacts 4mm²
5 male contacts 6mm²
Set of connectors for power cable
for connection M200D
Hood, outgoing circuit side entry
Female insert for Han Q4/2, UL
Gland for cable size
11,5 – 15,5 mm
5 female contacts 4mm²
5 female contacts 6mm²
UPE €
13,18
13,18
15,24
15,24
M200D
Supplementary products
3 Motor connection
3.1
Motor cable for motors in star connection, prefabricated
Motor Han 10 E
female insert
with star bridge
Motor with HanDrive
Motor cable
3.1.1
Motor –
connection
cable with
HanQ 8/0
connector
Without Brake, without Temperature transmitter
3.1.1.1 Cross section 1,5mm²
Order number
HTG:61 88 202 0424
HTG:61 88 202 0425
HTG:61 88 202 0426
Edition 01/2012
Page 14
Description
Motor cable for M200D
w/o Brake, w/o Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
4x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
42,84
47,12
52,80
M200D
Supplementary products
3.1.1.2 Cross section 2,5mm²
Order number
HTG:61 88 202 0427
HTG:61 88 202 0428
HTG:61 88 202 0429
3.1.2
Description
Motor cable for M200D
w/o Brake, w/o Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
4x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
43,47
48,31
54,79
With Brake (Brake voltage 400VAC or 180VDC), w/o Temperature
transmitter
3.1.2.1 Cross section 1,5mm²
Order number
HTG:61 88 202 0607
HTG:61 88 202 0608
HTG:61 88 202 0609
Description
Motor cable for M200D
with Brake, w/o Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
6x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
Description
Motor cable for M200D
with Brake, w/o Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
6x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
43,89
47,98
55,84
3.1.2.2 Cross section 2,5mm²
Order number
HTG:61 88 202 0610
HTG:61 88 202 0611
HTG:61 88 202 0612
Edition 01/2012
Page 15
45,04
51,25
59,51
M200D
Supplementary products
3.1.3
With Brake (Brake voltage 230VAC), w/o Temperature transmitter
3.1.3.1 Cross section 1,5mm²
Order number
HTG:61 88 202 0705
HTG:61 88 202 0706
HTG:61 88 202 0707
Description
Motor cable for M200D
with Brake, w/o Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
6x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
Description
Motor cable for M200D
with Brake, w/o Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
6x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
43,89
47,98
55,84
3.1.3.2 Cross section 2,5mm²
Order number
HTG:61 88 202 0708
HTG:61 88 202 0709
HTG:61 88 202 0710
3.1.4
45,04
51,25
59,51
With Brake (Brake voltage 400VAC or 180VDC), with Temperature
transmitter
3.1.4.1 Cross section 1,5mm²
Order number
HTG:61 88 202 0682
HTG:61 88 202 0683
HTG:61 88 202 0684
Edition 01/2012
Page 16
Description
Motor cable for M200D
with Brake, with Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
8x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
49,88
58,33
69,31
M200D
Supplementary products
3.1.4.2 Cross section 2,5mm²
Order number
HTG:61 88 202 0685
HTG:61 88 202 0686
HTG:61 88 202 0687
Description
Motor cable for M200D
with Brake, with Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
8x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
58,54
72,98
93,96
3.1.5 With Brake (Brake voltage 230VAC), with Temperature transmitter
3.1.5.1 Cross section 1,5mm²
Order number
HTG:61 88 202 0711
HTG:61 88 202 0712
HTG:61 88 202 0713
Description
Motor cable for M200D
with Brake 230V, with Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
8x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
Description
Motor cable for M200D
with Brake 230V, with Temperature transmitter
with star bridge
HAN Q8/0 side entry - HAN 10E
8x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
59,88
58,33
69,31
3.1.5.2 Cross section 2,5mm²
Order number
HTG:61 88 202 0714
HTG:61 88 202 0715
HTG:61 88 202 0716
Edition 01/2012
Page 17
58,54
72,98
93,96
M200D
Supplementary products
3.2
Motor cable for motors in star connection, one-sided
prefabricated
End open
Motor cable
3.2.1
Motor – connection
cable with
HanQ 8/0 connector
Without Brake, without Temperature transmitter
3.2.1.1 Cross section 1,5mm²
Order number
HTG:61 88 201 0211
HTG:61 88 201 0212
HTG:61 88 201 0213
Description
Motor cable for M200D
for Motor w/o Brake, w/o Temperature
transmitter
HAN Q8/0 side entry - open
4x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
Description
Motor cable for M200D
for Motor w/o Brake, w/o Temperature
transmitter
HAN Q8/0 side entry - open
4x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
19,70
23,83
29,51
3.2.1.2 Cross section 2,5mm²
Order number
HTG:61 88 201 0214
HTG:61 88 201 0215
HTG:61 88 201 0216
Edition 01/2012
Page 18
20,31
25,01
31,48
M200D
Supplementary products
3.2.2 With Brake (Brake voltage 400VAC or 180VDC), w/o Temperature
transmitter
3.2.2.1 Cross section 1,5mm²
Order number
HTG:61 88 201 0218
HTG:61 88 201 0219
HTG:61 88 201 0220
Description
Motor cable for M200D
for Motor with Brake, w/o Temperature
transmitter, HAN Q8/0 side entry - open
6x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
Description
Motor cable for M200D
for Motor with Brake, w/o Temperature
transmitter, HAN Q8/0 side entry - open
6x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
20,86
25,61
32,24
3.2.2.2 Cross section 2,5mm²
Order number
HTG:61 88 201 0221
HTG:61 88 201 0222
HTG:61 88 201 0223
21,46
27,88
34,21
3.2.3 With Brake (Brake voltage 230VAC), w/o Temperature transmitter
3.2.3.1 Cross section 1,5mm²
Order number
HTG:61 88 201 0470
HTG:61 88 201 0471
HTG:61 88 201 0472
Description
Motor cable for M200D
for Motor with Brake 230V, w/o Temperature
transmitter, HAN Q8/0 side entry - open
6x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
Description
Motor cable for M200D
for Motor with Brake 230V, w/o Temperature
transmitter, HAN Q8/0 side entry - open
6x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
20,86
25,61
32,24
3.2.3.2 Cross section 2,5mm²
Order number
HTG:61 88 201 0473
HTG:61 88 201 0474
HTG:61 88 201 0475
Edition 01/2012
Page 19
21,46
27,88
34,21
M200D
Supplementary products
3.2.4 With Brake (Brake voltage 400VAC or 180VDC), with Temperature
transmitter
3.2.4.1 Cross section 1,5mm²
Order number
HTG:61 88 201 0452
HTG:61 88 201 0453
HTG:61 88 201 0454
Description
Motor cable for M200D
for Motor with Brake, with Temperature
transmitter, HAN Q8/0 side entry - open
8x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
Description
Motor cable for M200D
for Motor with Brake, with Temperature
transmitter, HAN Q8/0 side entry - open
8x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
24,84
33,05
44,54
3.2.4.2 Cross section 2,5mm²
Order number
HTG:61 88 201 0455
HTG:61 88 201 0456
HTG:61 88 201 0457
33,16
48,19
69,00
3.2.5 With Brake (Brake voltage 230VAC), with Temperature transmitter
3.2.5.1 Cross section 1,5mm²
Order number
HTG:61 88 201 0476
HTG:61 88 201 0477
HTG:61 88 201 0478
Description
Motor cable for M200D
for Motor with Brake 230V, with Temperature
transmitter, HAN Q8/0 side entry - open
8x1,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
Description
Motor cable for M200D
for Motor with Brake 230V, with Temperature
transmitter, HAN Q8/0 side entry - open
8x2,5mm²
Length 1,5m
Length 3m
Length 5m
UPE €
24,84
33,05
44,54
3.2.5.2 Cross section 2,5mm²
Order number
HTG:61 88 201 0479
HTG:61 88 201 0480
HTG:61 88 201 0481
Edition 01/2012
Page 20
33,16
48,19
69,00
M200D
Supplementary products
3.3
Motor cable - sold by the ring
3.3.1 Motor cable 1,5mm² - sold by the ring
Order number
HTG:61 88 600 0121
HTG:61 88 600 0122
HTG:61 88 600 0123
HTG:61 88 600 0124
HTG:61 88 600 0129
HTG:61 88 600 0130
Description
Motor cable 4x1,5mm²
Length 10m
Length 50m
Motor cable 6x1,5mm²
Length 10m
Length 50m
Motor cable 8x1,5mm²
Length 10m
Length 50m
UPE €
43,41
157,20
48,59
183,06
66,82
245,67
3.3.2 Motor cable 2,5mm² - sold by the ring
Order number
HTG:61 88 600 0125
HTG:61 88 600 0126
HTG:61 88 600 0127
HTG:61 88 600 0128
HTG:61 88 600 0131
HTG:61 88 600 0132
Edition 01/2012
Page 21
Description
Motor cable 4x2,5mm²
Length 10m
Length 50m
Motor cable 6x2,5mm²
Length 10m
Length 50m
Motor cable 8x2,5mm²
Length 10m
Length 50m
UPE €
47,24
176,38
56,30
221,57
125,47
515,49
M200D
Supplementary products
3.4
Set of connector for motor connection cable, on the side of the
motor starter (M200D)
Motor – connection
cable with
HanQ 8/0 connector
Order number
HTG:61 83 401 0065
HTG:61 83 401 0066
Edition 01/2012
Page 22
Description
Set of connectors for motor cable
for connection to M200D
Hood, outgoing circuit side entry, UL
Male insert for Han Q8/0 Gland for cable size 9
–13 mm
8 male contacts 1,5mm²
8 male contacts 2,5mm²
UPE €
9,05
9,05
M200D
Supplementary products
3.5
Sets of connectors on the side of the motor
Han 10E Socket
(Motor)
Female insert
and star bridge
Motor with HanDrive
Order number
HTG:61 83 401 0047
HTG:61 83 401 0067
Edition 01/2012
Page 23
Description
Set of connectors for motor cable
for connection to Motor
Star jumper
Hood
Female insert for Han 10E, UL
Gland for cable size
9 – 13 mm
7 female contacts 1,5mm²
11 – 15,5 mm
7 female contacts 2,5mm²
UPE €
17,92
17,92
M200D
Supplementary products
4 Accessories
4.1
Set of connectors for power bus
switching cabinet / subdistributor
Set of connectors
HanQ 4/2
Hood
Male insert
Mounting case
HanQ 4/2
Female insert
Energy bus connector
Male
Energy bus connector
female
Order number
HTG: on request
HTG:61 88 201 0051
Order number
HTG:61 83 401 0116
HTG:61 83 401 0117
HTG:61 83 401 0118
HTG:61 83 401 0119
Edition 01/2012
Page 24
Description
Mounting case consisting of
Housing
Set of female insert for Han Q4/2
5 female contacts 4mm²
5 female contacts 6mm²
Description
Set of connectors
Hood, (with bracket) outgoing circuit top entry
Male insert for Han Q4/2, UL
Gland for cable size
12,5 – 16,5 mm
5 male contacts 4mm²
5 male contacts 6mm²
Set of connectors
Hood, (with bracket) outgoing circuit side entry
Male insert for Han Q4/2, UL
Gland for cable size
12,5 – 16,5 mm
5 male contacts 4mm²
12,5 – 16,5 mm
5 male contacts 6mm²
UPE €
70,64
UPE €
14,00
14,00
15,58
15,58
M200D
Supplementary products
4.2
Protective cover
Order number
HTG:09 12 008 5407
HTG:61 83 401 0070
HTG:09 30 010 5432
4.3
UPE €
Description
Crimping tool for Han Q4/2 for
Cross sections from 1,5mm² up to 6mm²
Crimping tool for Han Q8/0 for
Cross sections from 1,5mm² up to 6mm²
Crimping tool for Han 10e for
Cross sections from 1,5mm² up to 2,5mm²
UPE €
6,39
5,17
22,92
Crimping tool
Order number
HTG:09 99 000 0303
HTG:09 99 000 0110
HTG:09 99 000 0110
4.4
Description
Protection cover Han Q4/2 and Q8/0 for
housing, UL
Protection cover with bracket for Han Q4/2 and
Q8/0 Hood/Power T
Protection cover Han 10e for Hood (with
bracket), UL
307,06
382,52
382,52
Dismantle tool for male and female inserts
Order number
HTG:09 99 000 0305
HTG:09 99 000 0319
HTG:09 99 000 0319
Edition 01/2012
Page 25
Description
Dismantle tool for Han Q4/2 for
Cross sections from 1,5mm² up to 6mm²
Dismantle tool for Han Q8/0 for
Cross sections from 1,5mm² up to 6mm²
Dismantle tool for Han 10e for
Cross sections from 1,5mm² up to 2,5mm²
UPE €
9,69
17,19
17,19
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
SIRIUS M200D
Ergänzungsprodukte
(Supplementary products)
Technische Daten / Technical Data
Seite 27
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
1.1 Energie T-Klemmverbinder / Energy T-terminal connector
Han Power-S
1x Han Q4/2-F for wire gauge 4-6mm²
Artikel-Nr.
Querschnitt
Part No.
Wire gauge
HTG: 61 88 201 0500
2,5-4mm²
HTG: 61 88 201 0501
4-6mm²
PIN
h=55
1
L1
2
L2
3
L3
4
N
11
-
12
PE
2,5m
Kabelspezifikation
Kapitel 1.4--1.6
cable specification
chapter 1.4--1.6
h=55
Han Power-S
PIN
Y
Querschnitt
Wire gauge
1
L1
HTG:61 88 201 0502
5x2,5mm²
2
L2
HTG:61 88 201 0503
5x4mm²
3
L3
HTG:61 88 201 0504
5x6mm²
4
N
11
-
12
PE
Seite 28
Artikel-Nr.
Part No.
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
1.1 Energie T-Klemmverbinder / Energy T-terminal connector
Artikel-Nr.
Kabel
VPE/Satz
Part No.
Cable
Packaging
unit
HTG: 61 83 401 0200
10-13mm
2
HTG: 61 83 401 0201
13-16mm
2
HTG: 61 83 401 0202
16-19mm
2
HTG: 61 83 401 0203
19-22mm
2
HTG: 61 83 401 0204
Blindstopfen
1
Blind grommet
Dichtung
sealing
Seite 29
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
1.2 Energie T-Verbinder für Powerbus max. 25mm²
Power T-connector for power max. 25mm²
Artikel-Nr.
Querschnitt
Part No.
Wire gauge
HTG:61 88 201 0181
4-6mm²
PIN
Energie T-Verbinder
Power T-Connector
h=60
Lochbild
138
1
L1
2
L2
3
L3
4
N
11
-
12
-
74
PE
151
1.3 Energie Doppel-T-Klemmverbinder
Power double T-terminal connector
Doppel-T-Klemmverbinder
Artikel-Nr.
Querschnitt
Part No.
Wire gauge
HTG:61 88 202 0770
4-6mm²
2x Han Q4/2-F for wire gauge 4-6mm²
PIN
h=55
1
L1
2
L2
3
L3
4
N
11
-
12
PE
Seite 30
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
1.3 Energie Doppel-T-Klemmverbinder
Power double T-terminal connector
Artikel-Nr.
Kabel
VPE/Satz
Part No.
Cable
Packaging
unit
HTG:09 12 000 9970SI
10-13mm
2
HTG:09 12 000 9971SI
13-16mm
2
HTG:09 12 000 9972SI
16-19mm
2
HTG:09 12 000 9973SI
19-22mm
2
HTG:09 12 000 9974SI
Blindstopfen
1
Blind grommet
Dichtung
sealing
Seite 31
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
1.4.1 Energiebus- und Einspeiseleitungen (Ringware) 2,5mm²
Power bus and Supply cable (sold by ring) 2,5mm²
Anwendung
Artikel-Nr.
Länge
VPE
Part No.
length
Packaging
unit
5 x 2,5mm²
Verwendung als Energie- oder Verbindungsleitung,
HTG:61 88 600 0101
50m
1
HTG:61 88 600 0102
100m
1
>100m
1
auf Anfrage
on request
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 32
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
1.4.2 Energiebus- und Einspeiseleitungen (Ringware) 4mm²
Power bus and Supply cable (sold by ring) 4mm²
Artikel-Nr.
Länge
VPE
Part No.
length
Packaging
unit
5 x 4mm²
Anwendung
HTG:61 88 600 0107
50m
1
HTG:61 88 600 0108
100m
1
>100m
1
auf Anfrage
Verwendung als Energie- oder Verbindungsleitung,
on request
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 33
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
1.4.3 Energiebus- und Einspeiseleitungen (Ringware) 6mm²
Power bus and Supply cable (sold by ring) 6mm²
Anwendung
Artikel-Nr.
Länge
VPE
Part No.
length
Packaging
unit
5 x 6mm²
Verwendung als Energie- oder Verbindungsleitung,
HTG:61 88 600 0113
50m
1
HTG:61 88 600 0114
100m
1
>100m
1
auf Anfrage
on request
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 34
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
2.1 Energie Einspeiseleitung für Motorstarter konfektioniert
Power cables for motor starter prefabricated
4 x 2,5mm²
4 x 4,0mm²
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0400
1,5m
HTG:61 88 202 0401
3,0m
HTG:61 88 202 0402
5,0m
HTG:61 88 202 0403
10,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0404
1,5m
HTG:61 88 202 0405
3,0m
HTG:61 88 202 0406
5,0m
HTG:61 88 202 0407
10,0m
PIN
X
Y
1
L1
L1
Artikel-Nr.
Länge
2
L2
L2
Part No.
length
3
L3
L3
HTG:61 88 202 0408
1,5m
PE
PE
HTG:61 88 202 0409
3,0m
HTG:61 88 202 0410
5,0m
HTG:61 88 202 0411
10,0m
4 x 6,0mm²
H05VV5-F
Elektrische und technische Daten
Aufbau/design
/electrical and technical data
Variable Längen auf Anfrage
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 35
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
2.1 Energie Einspeiseleitung mit N-Leiter für Motorstarter konfektioniert
Power cables with N-conductor for motor starter prefabricated
5 x 2,5mm²
5 x 4,0mm²
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0693
1,5m
HTG:61 88 202 0694
3,0m
HTG:61 88 202 0695
5,0m
HTG:61 88 202 0696
10,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0697
1,5m
HTG:61 88 202 0698
3,0m
HTG:61 88 202 0699
5,0m
HTG:61 88 202 0700
10,0m
PIN
X
Y
1
L1
L1
Artikel-Nr.
Länge
2
L2
L2
Part No.
length
3
L3
L3
HTG:61 88 202 0701
1,5m
4
N
N
HTG:61 88 202 0702
3,0m
PE
PE
HTG:61 88 202 0703
5,0m
HTG:61 88 202 0704
10,0m
5 x 6,0mm²
H05VV5-F
Elektrische und technische Daten
Aufbau/design
/electrical and technical data
Variable Längen auf Anfrage
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 5G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 5G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 36
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
2.2 Energie Einspeiseleitung für Motorstarter, einseitig
konfektioniert / Power cables for motor starter, one-sided prefabricated
4 x 2,5mm²
4 x 4,0mm²
Ader
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0192
1,5m
HTG:61 88 201 0193
3,0m
HTG:61 88 201 0194
5,0m
HTG:61 88 201 0195
10,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0196
1,5m
HTG:61 88 201 0197
3,0m
HTG:61 88 201 0198
5,0m
HTG:61 88 201 0199
10,0m
PIN
X
1
L1
1
2
L2
2
Artikel-Nr.
Länge
Part No.
length
3
L3
3
HTG:61 88 201 0200
1,5m
PE
gn/ge
HTG:61 88 201 0201
3,0m
HTG:61 88 201 0202
5,0m
HTG:61 88 201 0203
10,0m
core
4 x 6,0mm²
ye/gn
H05VV5-F
Elektrische und technische Daten
Aufbau/design
/electrical and technical data
Variable Längen auf Anfrage
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 37
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
2.2 Energie Einspeiseleitung mit N-Leiter für Motorstarter, einseitig
Power cables with N-Conductor for motor starter, one-sided prefabricated
5 x 2,5mm²
5 x 4,0mm²
Ader
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0458
1,5m
HTG:61 88 201 0459
3,0m
HTG:61 88 201 0460
5,0m
HTG:61 88 201 0461
10,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0462
1,5m
HTG:61 88 201 0463
3,0m
HTG:61 88 201 0464
5,0m
HTG:61 88 201 0465
10,0m
PIN
X
1
L1
1
2
L2
2
Artikel-Nr.
Länge
Part No.
length
3
L3
3
HTG:61 88 201 0466
1,5m
4
N
4
HTG:61 88 201 0467
3,0m
HTG:61 88 201 0468
5,0m
HTG:61 88 201 0469
10,0m
PE
core
5 x 6,0mm²
gn/ge
ye/gn
H05VV5-F
Elektrische und technische Daten
Aufbau/design
/electrical and technical data
Variable Längen auf Anfrage
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 5G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 5G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 38
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
2.3.1 Energie-Einspeiseleitungen (Ringware) 2,5mm²
Power bus cable (sold by ring) 2,5mm²
Anwendung
Artikel-Nr.
Länge
VPE
Part No.
length
Packaging
unit
4 x 2,5mm²
Verwendung als Energie- oder Verbindungsleitung,
HTG:61 88 600 0115
50m
1
HTG:61 88 600 0116
100m
1
>100m
1
auf Anfrage
on request
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 39
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
2.3.2 Energie-Einspeiseleitungen (Ringware) 4mm²
Power bus cable (sold by ring) 4mm²
Artikel-Nr.
Länge
VPE
Part No.
length
Packaging
unit
4 x 4mm²
Anwendung
HTG:61 88 600 0117
50m
1
HTG:61 88 600 0118
100m
1
>100m
1
auf Anfrage
Verwendung als Energie- oder Verbindungsleitung,
on request
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 40
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
2.3.3 Energie-Einspeiseleitungen (RIngware) 6mm²
Power bus cable (sold by ring) 6mm²
Anwendung
Artikel-Nr.
Länge
VPE
Part No.
length
Packaging
unit
4 x 6mm²
Verwendung als Energie- oder Verbindungsleitung,
HTG:61 88 600 0119
50m
1
HTG:61 88 600 0120
100m
1
>100m
1
auf Anfrage
on request
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 41
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
2.4 Steckersatz für Energie-Einspeiseleitung / Connector set for power cable
Überwurfmutter Pg 16 Ku, sw
connecting nut PG16, thermoplastic, black
Stift-Stecker
Han Q8/0-Kg-16
Kupplungsgehäuse
hood cable to cable
Male insert
Dichteinsatz
seal insert
Han Q4/2-M-c
Stifteinsatz
male insert
Artikel-Nr.
Querschnitt
Dichteinsatz
Part No.
Wire gauge
seal insert
HTG:61 04 401 0556
4,0mm²
HTG:61 04 401 0545
6,0mm²
11,5-15,5 weiß/white
12-16,5 natur/natur
5x Han C Stiftkontakt, versilbert
Han C male contact, silver plated
Han Q8/0-Tg-16
Tüllengehäuse
hood side-entry
Han Q4/2-F-c
Buchseneinsatz
female insert
Überwurfmutter Pg 16 Ku, sw
connecting nut PG16, thermoplastic, black
Dichteinsatz
Buchsen-Stecker
Female insert
seal insert
5x Han C Buchsentkontakt, versilbert
Han C female contact, silver plated
Artikel-Nr.
Querschnitt
Dichteinsatz
Part No.
Wire gauge
seal insert
HTG:61 04 401 0550
4,0mm²
HTG:61 04 401 0502
6,0mm²
11,5-15,5 weiß/white
12-16,5 natur/natur
Crimpwerkzeug / Crimping tool
HTG:09 99 000 0110
Han D
Han E
Han C
1,5-4mm²
HTG:09 99 000 0303 Han C
4-6mm²
Seite 42
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.1.1 Motorleitung für Motoren in Sternschaltung, ohne Bremse,
/ Motor cable for motors in star
ohne Thermistor, konfektioniert
connection, without brake, without thermistor, prefabricated
Ansicht X
View X
Y
PIN
L1
1
Ansicht Y
Y
X
View Y
L1
2
-
L2
3
L3
L3
4
-
-
5
-
-
6
-
7
L2
8
-
9
-
-
10
-
-
PE
PE
4 x 1,5mm²
Brücke
bridge
4 x 2,5mm²
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0424
1,5m
HTG:61 88 202 0425
3,0m
HTG:61 88 202 0426
5,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0427
1,5m
HTG:61 88 202 0428
3,0m
HTG:61 88 202 0429
5,0m
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 43
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.1.2 Motorleitung für Motoren in Sternschaltung, mit Bremse AC400V /
/ Motor cable for motor in star
DC180V, ohne Thermistor, konfektioniert
connection with brake, without thermistor, prefabricated
Ansicht X
View X
Y
Ansicht Y
X
PIN
L1
1
View Y
Y
L1
2
-
L2
3
L3
L3
4
Bremse
Bremse
5
-
Bremse
6
Bremse
7
L2
8
-
9
-
-
10
-
-
PE
PE
6 x 1,5mm²
Brücke
bridge
6 x 2,5mm²
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0607
1,5m
HTG:61 88 202 0608
3,0m
HTG:61 88 202 0609
5,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0610
1,5m
HTG:61 88 202 0611
3,0m
HTG:61 88 202 0612
5,0m
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 44
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.1.2 Motorleitung für Motoren in Sternschaltung, mit Bremse 230V,
/ Motor cable for motor in star
ohne Thermistor, konfektioniert
connection with brake 230V, without thermistor, prefabricated
Ansicht X
View X
Y
Ansicht Y
X
PIN
L1
1
View Y
Y
L1
2
Bremse
L2
3
L3
L3
4
Bremse
Bremse
5
-
Bremse
6
-
7
L2
8
-
9
-
-
10
-
-
PE
PE
6 x 1,5mm²
Brücke
bridge
6 x 2,5mm²
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0705
1,5m
HTG:61 88 202 0706
3,0m
HTG:61 88 202 0707
5,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0708
1,5m
HTG:61 88 202 0709
3,0m
HTG:61 88 202 0710
5,0m
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 45
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.1.3 Motorleitung für Motoren in Sternschaltung, mit Bremse AC400V /
/ Motor cable for motor in star
DC180V, mit Thermistor, konfektioniert
connection with brake, with thermistor, prefabricated
Ansicht X
View X
Y
Ansicht Y
X
PIN
U
1
View Y
Y
U
2
-
W
3
W
V
4
Bremse
Bremse
5
Temp.
Bremse
6
Bremse
7
V
8
Temp.
9
-
Temp.
10
-
Temp.
PE
PE
8 x 1,5mm²
Brücke
bridge
8 x 2,5mm²
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0682
1,5m
HTG:61 88 202 0683
3,0m
HTG:61 88 202 0684
5,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0685
1,5m
HTG:61 88 202 0686
3,0m
HTG:61 88 202 0687
5,0m
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 46
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.1.3 Motorleitung für Motoren in Sternschaltung, mit Bremse 230V,
/ Motor cable for motor in star
mit Thermistor, konfektioniert
connection with brake 230V, with thermistor, prefabricated
Ansicht X
View X
Y
Ansicht Y
X
PIN
U
1
View Y
Y
U
2
Bremse
W
3
W
V
4
Bremse
Bremse
5
Temp.
Bremse
6
-
7
V
8
Temp.
9
-
Temp.
10
-
Temp.
PE
PE
8 x 1,5mm²
Brücke
bridge
8 x 2,5mm²
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0711
1,5m
HTG:61 88 202 0712
3,0m
HTG:61 88 202 0713
5,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 202 0714
1,5m
HTG:61 88 202 0715
3,0m
HTG:61 88 202 0716
5,0m
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 47
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.2.1 Motorleitung für Motoren in Sternschaltung, ohne Bremse,
ohne Thermistor, einseitig konfektioniert / Motor cable for motors
in star connection, without brake, w/o thermistor, one-sided prefabricated
Ansicht X
View X
PIN
X
Ader
core
1
L1
1
2
-
-
3
L3
3
4
-
-
5
-
-
6
-
-
7
L2
2
PE
gn/ge
4 x 1,5mm²
8
4 x 2,5mm²
ye/gn
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0211
1,5m
HTG:61 88 201 0212
3,0m
HTG:61 88 201 0213
5,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0214
1,5m
HTG:61 88 201 0215
3,0m
HTG:61 88 201 0216
5,0m
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 48
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.2.2 Motorleitung für Motoren in Sternschaltung, mit Bremse AC400V /
DC180V, ohne Thermistor, einseitig konfektioniert / Motor cable for motors
in star connection, with brake, w/o thermistor, one-sided prefabricated
Ansicht X
View X
PIN
X
Ader
core
1
L1
1
2
-
-
3
L3
3
4
Bremse
4
5
-
-
6
Bremse
5
7
L2
2
PE
gn/ge
6 x 1,5mm²
8
6 x 2,5mm²
ye/gn
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0218
1,5m
HTG:61 88 201 0219
3,0m
HTG:61 88 201 0220
5,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0221
1,5m
HTG:61 88 201 0222
3,0m
HTG:61 88 201 0223
5,0m
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 49
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.2.2 Motorleitung für Motoren in Sternschaltung, mit Bremse 230V,
ohne Thermistor, einseitig konfektioniert / Motor cable for motors
in star connection, with brake 230V, w/o thermistor, one-sided prefabricated
Ansicht X
View X
PIN
X
Ader
core
1
L1
1
2
Bremse
5
3
L3
3
4
Bremse
4
5
-
-
6
-
-
7
L2
2
PE
gn/ge
6 x 1,5mm²
8
6 x 2,5mm²
ye/gn
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0470
1,5m
HTG:61 88 201 0471
3,0m
HTG:61 88 201 0472
5,0m
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0473
1,5m
HTG:61 88 201 0474
3,0m
HTG:61 88 201 0475
5,0m
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 50
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.2.3 Motorleitung für Motoren in Sternschaltung, mit Bremse AC400V /
DC180V, mit Thermistor, einseitig konfektioniert / Motor cable for motors
in star connection, with brake, with thermistor, one-sided prefabricated
Ansicht X
View X
PIN
X
Ader
core
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0452
1,5m
HTG:61 88 201 0453
3,0m
HTG:61 88 201 0454
5,0m
1
L1
1
2
-
-
3
L3
3
4
Bremse
4
5
Temp.
6
6
Bremse
5
7
L2
2
HTG:61 88 201 0455
1,5m
8
Temp.
7
HTG:61 88 201 0456
3,0m
PE
gn/ge
HTG:61 88 201 0457
5,0m
8 x 1,5mm²
8 x 2,5mm²
ye/gn
Artikel-Nr.
Länge
Part No.
length
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 51
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.2.3 Motorleitung für Motoren in Sternschaltung, mit Bremse 230V,
mit Thermistor, einseitig konfektioniert
/ Motor cable for motors
in star connection, with brake 230V, with thermistor, one-sided prefabricated
Ansicht X
View X
PIN
X
Ader
core
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 201 0476
1,5m
HTG:61 88 201 0477
3,0m
HTG:61 88 201 0478
5,0m
1
L1
1
2
Bremse
5
3
L3
3
4
Bremse
4
5
Temp.
6
6
-
-
7
L2
2
HTG:61 88 201 0479
1,5m
8
Temp.
7
HTG:61 88 201 0480
3,0m
PE
gn/ge
HTG:61 88 201 0481
5,0m
8 x 1,5mm²
8 x 2,5mm²
ye/gn
Artikel-Nr.
Länge
Part No.
length
H05VV5-F
Elektrische und technische Daten
Variable Längen auf Anfrage
Aufbau/design
/electrical and technical data
Variable lengths on request
-blanke Cu-Litze, feindrähtig
Nennspannung:
/stranded bare conductor made of
/nominal voltage
Cu
Uo/U
-Litzenaufbau nach VDE 0295, Klasse 5
Prüfspannung:
/stranded structure according
/test voltage
to VDE 0295, class 5 + IEC 60228 class 5 +
Isolationswiderstand: >20MOhm x km
HD 383 CLASS 5
/leakage resistance
300/500V
mind. 2000V
Werkstoff:
-Adern PVC-isoliert
Biegeradius:
/core insulation: PVC
/bending radius
-Schutzleiter grüngelb
Temperaturbereich:
/green-yellow protective conductor
/temperature range
-Lagenverseilung
bewegt
/cores twisted in layers
/moved
-Außenmantel:PVC, flammwidrig
unbewegt
/outer jacket : PVC, flame retardant
/unmoved
-Mantelfarbe schwarz 4G 2,5; 4,0; 6,0
Brandfortleitung /Flammwidrigkeit:
/outer jacket colour black 4G 2,5; 4,0; 6,0
gem. VDE 0472 Teil 804, Prüfart B und IEC
332-1
-Ölbeständig / oil-resistant
Seite 52
Gehäuse/housing
ca. 15x Kabeldurchmesser
approx. 15x cable diam
PC
/material
Verriegelungselement: PA
/interlock element
Überwurfmutter PG 16
- 5°C bis +70°C
/lock nut
Werkstoff:
-30°C bis +70°C
PC
/material
Dichteinsatz 9,0-13,0 rot
/seal insert 9,0-13,0 red
Dichteinsatz 11,0-15,5 weiß
/seal insert 11,0-15,5 white
/fire performance according to IEC 60332-1
Werkstoff:
to DIN VDE 0472 part 804
/material
Ausgabe 11/2009
TPE
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.3.1 Motorleitung (Meterware) 1,5mm²
Motor cable (sold by meter) 1,5mm²
Anwendung
4 x 1,5mm²
Verwendung als Energie- oder Verbindungsleitung,
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 600 0121
10m
HTG:61 88 600 0122
50m
auf Anfrage
>50m
on request
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 53
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.3.1 Motorleitung (Meterware) 1,5mm²
Motor cable (sold by meter) 1,5mm²
Anwendung
6 x 1,5mm²
Verwendung als Energie- oder Verbindungsleitung,
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 600 0123
10m
HTG:61 88 600 0124
50m
auf Anfrage
on request
>50m
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 54
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.3.1 Motorleitung (Meterware) 1,5mm²
Motor cable (sold by meter) 1,5mm²
Anwendung
8 x 1,5mm²
Verwendung als Energie- oder Verbindungsleitung,
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 600 0129
10m
HTG:61 88 600 0130
50m
auf Anfrage
on request
>50m
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 55
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.3.2 Motorleitung (Meterware) 2,5mm²
Motor cable (sold by meter) 2,5mm²
Anwendung
4 x 2,5mm²
Verwendung als Energie- oder Verbindungsleitung,
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 600 0125
10m
HTG:61 88 600 0126
50m
auf Anfrage
>50m
on request
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 56
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.3.2 Motorleitung (Meterware) 2,5mm²
Motor cable (sold by meter) 2,5mm²
6 x 2,5mm²
Anwendung
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 600 0127
10m
HTG:61 88 600 0128
50m
auf Anfrage
on request
>50m
Verwendung als Energie- oder Verbindungsleitung,
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 57
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.3.2 Motorleitung (Meterware) 2,5mm²
Motor cable (sold by meter) 2,5mm²
8 x 2,5mm²
Anwendung
Artikel-Nr.
Länge
Part No.
length
HTG:61 88 600 0131
10m
HTG:61 88 600 0132
50m
auf Anfrage
on request
>50m
Verwendung als Energie- oder Verbindungsleitung,
als Meß-, Kontroll- und Steuerleitung im Werkzeugmaschinenbau, Anlagenbau, an Fließbändern und
Applications
Fertigungsstraßen.
Used as ernergy or connecting cable, as measuring, checking and
Geeignet für feste Verlegung oder flexible Anwen-
control cable in maschine tool manufacturing and on assembly lines
dungen bei freier Bewegung ohne zwangsweise
and production lines. Suitable for fixed intallation with unrestricted
Bewegungsführung und ohne Zugbeanspruchung,
mobility without forced movement control and without exosure to tensile
in trockenen und feuchten Räumen, im Freien fest
load. Installation in dry and moist rooms. If you use it outside look at
verlegt unter Beachtung des Temperaturbereichs.
the temperature range.
Keine Anwendung im Wasser oder in der Erde.
Could not be used in water or in the ground.
Aufbau/design
Elektrische und technische Daten
/electrical and technical date
-blanke Cu-Litze, feindrähtig
Nennspannung / rated voltage :
Uo/U 300/500V
/stranded bare conductor made of Cu
Prüfspannung / test voltage :
mind. 2000V
-Litzenaufbau nach VDE 0295, Klasse 5
Isolationswiderstand / leakage resistance : >20MOhm x km
Biegeradius / bending radius :
bzw. IEC 60228 cl.5
approx. 7,5x cable diam
/strand structure according to VDE 0295,
Temperaturbereich / temperature range :
class 5 + IEC 60228 class 5 +
bewegt
-Adern spezial PVC
- 5°C bis +70°C
/moved
/core insulation: special PVC
unbewegt
- schwarze Adern mit fortl, weißem
-30°C bis +70°C
/unmoved
Ziffernaufdruck / black cores with white
Brandfortleitung /Flammwidrigkeit: gem. VDE 0472 Teil 804, Prüfart B
printed consecutive number coding
und IEC 332-1 / fire performence according to IEC 60332-1 to
-Schutzleiter grüngelb
DIN VDE 0472 part 804
/green-yellow protective conductor
-Lagenverseilung /cores twisted in layers
-Außenmantel: spezial PVC, flammwidrig
und UV-beständig
/outer sheath: special PVC, flame retardant and
UV-resistance
-Mantelfarbe schwarz RAL 9005
/core-colour black RAL 9005
Seite 58
ca. 15x Kabeldurchmesser
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
3.4 Steckersätze für Motor-Anschlussleitung auf Motorstarterseite,
Set of connectors for motor connection cable on the side of the motor starter
Dichteinsatz
Han Q8/0-Tg-16
Tüllengehäuse
seal insert
Überwurfmutter Pg 16 Ku, sw
connecting nut PG16, thermoplastic, black
hood side-entry
Stift-Stecker
Male insert
Han Q4/2-M-c
Stifteinsatz
male insert
Artikel-Nr.
Querschnitt
Dichteinsatz
Part No.
Wire gauge
seal insert
HTG:61 83 401 0065
1,5mm²
9-13 rot/red
HTG:61 83 401 0066
2,5mm²
11,5-15,5 weiß/white
6x Han E-Stiftkontakt, versilbert
Han E male contact, silver plated
3.5 Steckersätze für Motor-Anschlussleitung auf Motorstarterseite,
ohne Schutzbeschaltung / Set of connectors for motor connection cable on
the side of the motor , without EMC protective circuit
Dichteinsatz
seal insert
Verschraubung
cable gland
Han 10B-gg-R-M20
Tüllengehäuse
hood top-entry
Han 10E-F-c
Buchseneinsatz
Buchsen-Stecker
female insert
Female insert
Artikel-Nr.
Querschnitt
Dichteinsatz
Part No.
Wire gauge
seal insert
HTG:61 83 401 0047
1,5mm²
9-13 rot/red
HTG:61 83 401 0067
2,5mm²
11,5-15,5 weiß/white
7x Han E-Buchsenkontakt, versilbert
Han E female contact, silver plated
Seite 59
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
4.1 Steckersätze für Energiebus Anschluss Schaltschrank /
Unterverteiler / Set of connectors for power bus switching cabinet/subdistributor
Überwurfmutter Pg 16 Ku, sw
Han Q8/0-kg-16
Kupplungsgehäuse
Dichteinsatz
hoods cable to cable
seal insert
connecting nut PG16, thermoplastic, black
Buchsen-Stecker
Female insert
Schaltschrank Innenseite
Artikel-Nr.
Querschnitt
inside control cabinet
Part No.
Wire gauge
HTG:61 88 201 0051
6mm²
Schaltschrank Außenseite
outside control cabinet
Baugröße Han 24B
Überwurfmutter Pg 16 Ku, sw
connecting nut PG16, thermoplastic, black
Dichteinsatz
seal insert
Han Q8/0-Kg-16
Kupplungsgehäuse
hood thermoplastic
Han Q4/2-M-c
Stifteinsatz
male insert
Stift-Stecker
Male insert
5x Han C-Stiftkontakt, versilbert
Han C male contact, silver plated
Seite 60
Artikel-Nr.
Querschnitt
Dichteinsatz
Part No.
Wire gauge
seal insert
HTG:61 83 401 0116
4mm²
12,5-16,5 grau/grey
HTG:61 83 401 0117
6mm²
12,5-16,5 grau/grey
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
4.1 Steckersätze für Energiebus Anschluss Schaltschrank /
Unterverteiler / Set of connectors for power bus switching cabinet/subdistributor
Han Q8/0-Kg-16
Kupplungsgehäuse
Überwurfmutter Pg 16 Ku, sw
connecting nut PG16, thermoplastic, black
hoods cable to cable
Han Q4/2-M-c
Stifteinsatz
male insert
Dichteinsatz
seal insert
Stift-Stecker
Male insert
5x Han C-Stiftkontakt, versilbert
Han C male contact, silver plated
Seite 61
Artikel-Nr.
Querschnitt
Dichteinsatz
Part No.
Wire gauge
seal insert
HTG:61 83 401 0118
4mm²
12,5-16,5 grau/grey
HTG:61 83 401 0119
6mm²
12,5-16,5 grau/grey
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
4.2 Verschlußkappen / Protection covers (if there is no plug used)
Han Q4/2 und Q 8/2-AK-QB,schwarz
Protection cover for male insert, black
Artikel-Nr.
Part No.
HTG: 09 12 008 5407
Han Q Abdeckkappe
mit Verriegelungsbügel
Han Q protection cover
Artikel-Nr.
Part No.
HTG: 61 83 401 0070
Han 10B-AK-LB-Dichtung, Metallabdeckkappe
metal cover
Artikel-Nr.
Part No.
HTG: 09 30 010 5432
Seite 62
Ausgabe 11/2009
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
4.3 Crimpzangen / Crimping tools
Crimpzange für Han Q 4/2
crimping tool for Han Q4/2
Artikel-Nr.
Querschnitt
Part No.
Wire gauge
HTG:09 99 000 0303
Artikel-Nr.
Querschnitt
Part No.
Wire gauge
HTG:09 99 000 0110
Crimpzange für Han Q 8/0 / Han 10E
crimping tool for Han Q 8/0 / Han 10E
Seite 63
Ausgabe 11/2009
4mm²-6mm²
0,5mm²-4mm²
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
M200D
4.4 Demontagewerkzeuge für Stifte und Buchsen
Dismantle tools for male and female inserts
Demontagewerkzeug für Han Q 4/2
Removal tool for Han Q 4/2
Artikel-Nr.
Querschnitt
Part No.
Wire gauge
HTG:09 99 000 0305
Artikel-Nr.
Querschnitt
Part No.
Wire gauge
HTG:09 99 000 0319
Demontagewerkzeug für Han Q 8/0 / Han 10E
Removal tool for Han Q 8/0 / Han 10E
Seite 64
Ausgabe 11/2009
4mm²-6mm²
0,5mm²-4mm²
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
Bestell-Nummern-Verzeichnis
List of part numbers
M200D
Artikelnummer
Kapitel
Artikelnummer
Part No.
Chapter
Part No.
Chapter
HTG:61 83 401 0200
HTG:61 83 401 0201
HTG:61 83 401 0202
HTG:61 83 401 0203
HTG:61 83 401 0204
HTG:61 88 201 0502
HTG:61 88 201 0503
HTG:61 88 201 0504
HTG:61 88 201 0500
HTG:61 88 201 0501
HTG:61 88 202 0770
HTG:09 12 008 5407
HTG:09 30 010 5432
HTG:09 99 000 0110
HTG:09 99 000 0303
HTG:09 99 000 0305
HTG:09 99 000 0319
HTG:61 04 401 0502
HTG:61 04 401 0545
HTG:61 04 401 0550
HTG:61 04 401 0556
HTG:61 83 401 0047
HTG:61 83 401 0065
HTG:61 83 401 0066
HTG:61 83 401 0067
HTG:61 83 401 0070
HTG:61 83 401 0116
HTG:61 83 401 0117
HTG:61 83 401 0118
HTG:61 83 401 0119
HTG:61 88 201 0051
HTG:61 88 201 0181
HTG:61 88 201 0192
HTG:61 88 201 0193
HTG:61 88 201 0194
HTG:61 88 201 0195
HTG:61 88 201 0196
HTG:61 88 201 0197
HTG:61 88 201 0198
HTG:61 88 201 0199
HTG:61 88 201 0200
2.1.3
2.1.3
2.1.3
3.1.1.1
3.1.1.1
3.1.1.1
3.1.1.2
3.1.1.2
3.1.1.2
3.1.1.2
3.3.1.1
3.3.1.1
3.3.1.1
3.3.1.2
3.3.1.2
3.3.1.2
3.1.3.1
3.1.3.1
3.1.3.1
3.1.3.2
3.1.3.2
3.1.3.2
1.4.1
1.4.1
1.4.2
1.4.2
1.4.3
1.4.3
2.3.1
2.3.1
2.3.2
2.3.2
2.2.1
2.2.1
2.2.1
2.2.1
2.2.2
2.2.2
2.2.2
2.2.2
2.2.3
HTG:61 88 201 0201
HTG:61 88 201 0202
HTG:61 88 201 0203
HTG:61 88 201 0211
HTG:61 88 201 0212
HTG:61 88 201 0213
HTG:61 88 201 0214
HTG:61 88 201 0215
HTG:61 88 201 0216
HTG:61 88 201 0218
HTG:61 88 201 0219
HTG:61 88 201 0220
HTG:61 88 201 0221
HTG:61 88 201 0222
HTG:61 88 201 0223
HTG:61 88 201 0452
HTG:61 88 201 0453
HTG:61 88 201 0454
HTG:61 88 201 0455
HTG:61 88 201 0456
HTG:61 88 201 0457
HTG:61 88 201 0458
HTG:61 88 201 0459
HTG:61 88 201 0460
HTG:61 88 201 0461
HTG:61 88 201 0462
HTG:61 88 201 0463
HTG:61 88 201 0464
HTG:61 88 201 0465
HTG:61 88 201 0466
HTG:61 88 201 0467
HTG:61 88 201 0468
HTG:61 88 201 0469
HTG:61 88 201 0470
HTG:61 88 201 0471
HTG:61 88 201 0472
HTG:61 88 201 0473
HTG:61 88 201 0474
HTG:61 88 201 0475
HTG:61 88 201 0476
HTG:61 88 201 0477
2.2.3
2.2.3
2.2.3
3.2.1.1
3.2.1.1
3.2.1.1
3.2.1.2
3.2.1.2
3.2.1.2
3.2.2.1
3.2.2.1
3.2.2.1
3.2.2.2
3.2.2.2
3.2.2.2
3.2.3.1
3.2.3.1
3.2.3.1
3.2.3.2
3.2.3.2
3.2.3.2
2.2.1
2.2.1
2.2.1
2.2.1
2.2.2
2.2.2
2.2.2
2.2.2
2.2.3
2.2.3
2.2.3
2.2.3
3.2.2.1
3.2.2.1
3.2.2.1
3.2.2.2
3.2.2.2
3.2.2.2
3.2.3.1
3.2.3.1
Seite 65
Ausgabe 11/2009
Kapitel
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
Bestell-Nummern-Verzeichnis
List of part numbers
M200D
Artikelnummer
Kapitel
Artikelnummer
Part No.
Chapter
Part No.
Chapter
HTG:61 88 201 0478
HTG:61 88 201 0479
HTG:61 88 201 0480
HTG:61 88 201 0481
HTG:61 88 202 0400
HTG:61 88 202 0401
HTG:61 88 202 0402
HTG:61 88 202 0403
HTG:61 88 202 0404
HTG:61 88 202 0405
HTG:61 88 202 0406
HTG:61 88 202 0407
HTG:61 88 202 0408
HTG:61 88 202 0409
HTG:61 88 202 0410
HTG:61 88 202 0411
HTG:61 88 202 0424
HTG:61 88 202 0425
HTG:61 88 202 0426
HTG:61 88 202 0427
HTG:61 88 202 0428
HTG:61 88 202 0429
HTG:61 88 202 0607
HTG:61 88 202 0608
HTG:61 88 202 0609
HTG:61 88 202 0610
HTG:61 88 202 0611
HTG:61 88 202 0612
HTG:61 88 202 0682
HTG:61 88 202 0683
HTG:61 88 202 0684
HTG:61 88 202 0685
HTG:61 88 202 0686
HTG:61 88 202 0687
HTG:61 88 202 0693
HTG:61 88 202 0694
HTG:61 88 202 0695
HTG:61 88 202 0696
HTG:61 88 202 0697
HTG:61 88 202 0698
HTG:61 88 202 0699
3.2.3.1
3.2.3.2
3.2.3.2
3.2.3.2
2.1
2.1
2.1
2.1
2.1.2
2.1.2
2.1.2
2.1.2
2.1.3
2.1.3
2.1.3
2.1.3
3.1.1.1
3.1.1.1
3.1.1.1
3.1.1.2
3.1.1.2
3.1.1.2
3.3.1.1
3.3.1.1
3.3.1.1
3.3.1.2
3.3.1.2
3.3.1.2
3.1.3.1
3.1.3.1
3.1.3.1
3.1.3.2
3.1.3.2
3.1.3.2
2.1
2.1
2.1
2.1
2.1.2
2.1.2
2.1.2
HTG:61 88 202 0700
HTG:61 88 202 0701
HTG:61 88 202 0702
HTG:61 88 202 0703
HTG:61 88 202 0704
HTG:61 88 202 0705
HTG:61 88 202 0706
HTG:61 88 202 0707
HTG:61 88 202 0708
HTG:61 88 202 0709
HTG:61 88 202 0710
HTG:61 88 202 0711
HTG:61 88 202 0712
HTG:61 88 202 0713
HTG:61 88 202 0714
HTG:61 88 202 0715
HTG:61 88 202 0716
HTG:61 88 600 0101
HTG:61 88 600 0102
HTG:61 88 600 0107
HTG:61 88 600 0108
HTG:61 88 600 0113
HTG:61 88 600 0114
HTG:61 88 600 0115
HTG:61 88 600 0116
HTG:61 88 600 0117
HTG:61 88 600 0118
HTG:61 88 600 0119
HTG:61 88 600 0120
HTG:61 88 600 0121
HTG:61 88 600 0122
HTG:61 88 600 0123
HTG:61 88 600 0124
HTG:61 88 600 0125
HTG:61 88 600 0126
HTG:61 88 600 0127
HTG:61 88 600 0128
HTG:61 88 600 0129
HTG:61 88 600 0130
HTG:61 88 600 0131
HTG:61 88 600 0132
2.1.2
2.1.3
2.1.3
2.1.3
2.1.3
3.3.1.1
3.3.1.1
3.3.1.1
3.3.1.2
3.3.1.2
3.3.1.2
3.1.3.1
3.1.3.1
3.1.3.1
3.1.3.2
3.1.3.2
3.1.3.2
1.4.1
1.4.1
1.4.2
1.4.2
1.4.3
1.4.3
2.3.1
2.3.1
2.3.2
2.3.2
2.3.3
2.3.3
3.3.1
3.3.1
3.3.1
3.3.1
3.3.2
3.3.2
3.3.2
3.3.2
3.3.1
3.3.1
3.3.2
3.3.2
Seite 66
Ausgabe 11/2009
Kapitel
HARTING Deutschland GmbH & Co. KG
Simeonscarré 1 32427 Minden Deutschland
Tel.: (0571) 8896-178 Fax: (0571) 8896-177
E-Mail: [email protected] Internet: http://www.HARTING.com
Tochtergesellschaften - weltweit
Subsidiary companies - worldwide
Australia
HARTING Pty Ltd
Suite 11 / 2 Enterprise Drive
Bundoora 3083, AUS-Victoria
Tel. +61 9466 7088, Fax +61 9466 7099
E-Mail: [email protected], www.HARTING.com
Belgium
HARTING N.V./S.A.
Z.3 Doornveld 23, B-1731 Zellik
Tel. +32 2 466 0190, Fax +32 2 466 7855
E-Mail: [email protected], www.HARTING.be
Brazil
HARTING Ltda.
Av. Dr. Lino de Moraes, Pq. Jabaquara, 255
CEP 04360-001 – São Paulo – SP – Brazil
Tel. +55 11 5035 0073, Fax +55 11 5034 4743
E-Mail: [email protected]
www.HARTING.com.br
China
Zhuhai HARTING Limited, Shanghai branch
Room 5403, HK New World Tower
300 Huai Hai Road (M.)
Shanghai 200021, China
Tel. +86 21 6386 2200, Fax +86 21 6386 8636
E-Mail: [email protected]
www.HARTING.com.cn
Deutschland
HARTING Deutschland GmbH & Co. KG
Postfach 2451, D-32381 Minden
Simeonscarré 1, D-32427 Minden
Tel. +49 571 8896 0, Fax +49 571 8896 282
E-Mail: [email protected]
www.HARTING.com
Finnland
HARTING Oy
Teknobulevardi 3-5, PL 35, FI-01530 Vantaa
Tel. +358 9 350 87 300, Fax +358 9 350 87 320
E-Mail: [email protected], www.HARTING.fi
Frankreich
HARTING France
181 avenue des Nations, Paris Nord 2
BP 66058 Tremblay en France
F-95972 Roissy Charles de Gaulle Cédex
Tel. +33 1 4938 3400, Fax +33 1 4863 2306
E-Mail: [email protected], www.HARTING.fr
Great Britain
HARTING Ltd., Caswell Road
Brackmills Industrial Estate
GB-Northampton, NN4 7PW
Tel. +44 1604 827 500, Fax +44 1604 706 777
E-Mail: [email protected]
www.HARTING.co.uk
Hong Kong
HARTING (HK) Limited,
Regional Office Asia Pacific
3512 Metroplaza Tower 1, 223 Hing Fong Road
Kwai Fong, N. T., Hong Kong
Tel. +852 2423 7338, Fax +852 2480 4378
E-Mail: [email protected]
www.HARTING.com.hk
Seite 67
India
HARTING India Private Limited
No. D, 4th Floor, ‚Doshi Towers‘
No. 156 Poonamallee High Road,
Kilpauk, Chennai 600 010, Tamil Nadu, Chennai
Tel. +91 44 435604 15, Fax +91 44 435604 17
E-Mail: [email protected], www.HARTING.com
Italy
HARTING SpA
Via dell‘Industria 7, I-20090 Vimodrone (Milano)
Tel. +39 02 250801, Fax +39 02 2650 597
E-Mail: [email protected], www.HARTING.it
Japan
HARTING K. K.
Yusen Shin-Yokohama 1 Chome Bldg., 2F
1-7-9, Shin-Yokohama, Kohoku-ku, Yokohama
Yokohama 222-0033 Japan
Tel. +81 45 476 3456, Fax +81 45 476 3466
E-Mail: [email protected], www.HARTING.co.jp
Korea
HARTING Korea Limited
#308 Yatap Leaders Building
342-1, Yatap-dong, Bundang-gu,
Sungnam-Si Gyeonggi-Do
463-828 Republic of Korea
Tel. +82 31 781 4613, Fax +82 31 781 4616
E-Mail: [email protected]
www.HARTING.com.cn/kr
Netherlands
HARTING B.V.
Larenweg 44, NL-5234 KA ‚s-Hertogenbosch
Postbus 3526, NL-5203 DM ‚s-Hertogenbosch
Tel. +31 736 410 404, Fax +31 736 440 699
E-Mail: [email protected], www.HARTINGbv.nl
Norway
HARTING A/S
Østensjøveien 36, N-0667 Oslo
Tel. +47 22 700 555, Fax +47 22 700 570
E-Mail: [email protected], www.HARTING.no
Österreich
HARTING Ges. m. b. H.
Deutschstraße 19, A-1230 Wien
Tel. +431 6162121, Fax +431 6162121-21
E-Mail: [email protected], www.HARTING.at
Poland
HARTING Polska Sp. z o. o
Ul. Kamienskiego 201-219, PL-51-126 Wroclaw
Tel. +48 71 352 81 71, Fax +48 71 320 74 44
E-Mail: [email protected], www.HARTING.pl
Portugal
HARTING Iberia, S. A.
Avda. Josep Tarradellas, 20-30, 4 o 6a
E-08029 Barcelona
Tel. +34 93 363 84 75, Fax +34 93 419 95 85
E-Mail: [email protected]
www.HARTING.es/pt
Ausgabe 11/2009
Russia
HARTING ZAO
Maily Sampsoniyevsky prospect 2A
194044 Saint Petersburg, Russia
Tel. +7 812 327 6477, Fax +7 812 327 6478
E-Mail: [email protected], www.HARTING.ru
Sweden
HARTING AB
Gustavslundsvägen 141 B 4tr, S-167 51 Bromma
Tel. +46 8 445 7171, Fax +46 8 445 7170
E-Mail: [email protected], www.HARTING.se
Schweiz
HARTING AG
Industriestrasse 26, CH-8604 Volketswil
Tel. +41 44 908 20 60, Fax +41 44 908 20 69
E-Mail: [email protected], www.HARTING.ch
Singapore
HARTING Singapore Pte Ltd.
25 International Business Park
#02-06 German Centre, Singapore 609916
Tel. +65 6225 5285, Fax +65 6225 9947
E-Mail: [email protected], www.HARTING.com
Spain
HARTING Iberia S.A.
Josep Tarradellas 20-30 4o 6a
E-08029 Barcelona
Tel. +34 93 363 84 75, Fax +34 93 419 95 85
E-Mail: [email protected], www.HARTING.es
Taiwan
HARTING R.O.C. Limited
Room 1, 5/F, 495 GuangFu South Road
RC-110 Taipei, Taiwan
Tel. +886 227 586 177, Fax +886 227 587 177
E-Mail: [email protected], www.HARTING.
com.tw
Czech Republic
HARTING spol. s.r.o.
Ml´ynská 2, CZ-160 00 Praha 6
Tel. +420 220 380 460, Fax +420 220 380 461
E-Mail: [email protected], www.HARTING.cz
Ungarn
HARTING Magyarország Kft.
Fehérvári út 89-95, H-1119 Budapest
Tel. +36 1 205 34 64, Fax +36 1 205 34 65
E-Mail: [email protected], www.HARTING.hu
USA
HARTING Inc. of North America
1370 Bowes Road, USA-Elgin, Illinois 60123
Tel. +1 877 741-1500 (toll free)
Fax +1 866 278-0307 (Inside Sales)
Fax +1 847 717-9430 (Sales and Marketing)
E-Mail: [email protected],
www.HARTING-USA.com
Eastern-Europe
HARTING Eastern Europe GmbH
Bamberger Straße 7, D-01187 Dresden
Tel. +49 351 4361 760, Fax +49 351 4361 770
E-Mail: [email protected]
www.HARTING.com

Documentos relacionados