Trend-Watch-Group - Bundesamt für Energie BFE

Transcrição

Trend-Watch-Group - Bundesamt für Energie BFE
Trend-Watch-Group
Heinz Beer
eae energie agentur elektrogeräte
SWICO Ressort Umwelt
Erkenntnis und Studie in EU
Aussagen von Marta Nagy-Rothengass (EU-Kommission DG
Information Society, Head of Unit ICT for Sustainable Growth) vom 27.
September 2007
Zur Rolle von ICT:
ICT accounts for over half of the economic growth and of the
productivity growth in modern economies and has the potential to
account for at least half of the Energy Efficiency improvements
ICT can not only reduce its own footprint but also help reduce that
of all other sectors of the economy
ICT is a small part of the problem and major part of the solution!
Was bedeutet dies (Aussage, Studie) für die Trend-Watch-Group ?
http://cordis.europa.eu/ist/environment/mission.htm
Heinz Beer
Trend-Watch-Group 9.11.07
2
Inhalt
Übersicht „Richtlinien in der EU“
Stand EuP: Lots im Bereich IT
Computer
TV
Imaging Devices
Stand-by und Off-Mode losses
Power Supplies
Settop Boxes
Heinz Beer
Trend-Watch-Group 9.11.07
3
EU-“Direktiven“ im Bereich Energie, Ecodesign
Aktion Plan
„3 x 20 bis 2020“
Elektrizitätswirtschaft
Konsumenten
ESD
- 9 % in 9 Jahren
ø1998 – 2002 bis 201
EU-Mitgliedsländer
EEAP (bis 31.8.07)
Kriterien zur Effizienz
Sustainable Energy
Campaign
2006 - 2008
Verhalten
Länder, Städte…..
EuP
Lot als Grundlage für
Massnahmen
Produkte
Energy Star
Abkommen EU-USA
bis 2010 verlängert
Produkte
Battery-Directive
(Design-Directive)
„Entfernbarkeit“
Label
IPP
Heinz Beer
Produkte
Studien als Vorbereitung
Trend-Watch-Group 9.11.07
4
Produkte (Nokia)
Weitere EU-“Direktiven“ im Bereich „Umwelt“
WEEE
Verantwortung der
Hersteller über den ganzen
Lebenszyklus eines
Produkts
Transboundry – Shippment
Definition „Hersteller“
Mahnung an Länder
Registrierung, Statistik
Revision Febr. 2008
RoHS
Verbot von 6 Chemikalien
für IT, OE und CE –
Produkte
Liste mit Ausnahmen
Auch in anderen Ländern
Einzelne Länder mit tieferen
Werte, weitere Stoffe, für
mehr Produkte, und
Deklaration(en)
Revision Febr. 2008
Waste Frame Work
Gesamter Abfall
WEEE sollte so bleiben
REACH
Seit 1.7.07 in Kraft
Agentur in Helsinki
Liste der Produkte offen
Heinz Beer
Trend-Watch-Group 9.11.07
5
Action Plan
EU leaders set combined targets in the Action Plan:
3*20 by 2020
Reduction of GHG emissions of 20% (relative to 1990)
20% renewable energy (present 6,5%)
Saving 20 % of the EU energy consumption
Bestätigt an EU-Gipfel in England und Deutschland
Blick auf Kyoto II
Reduction GHG emmisions of 30% with others
Reduktion CO2 – Ausstoss der Motorfahrzeuge (130 g
CO2/km bzw, 120 g CO2/km EU heute bei (Schweiz heute
zwischen 210 und 22 g/km)
Heinz Beer
Trend-Watch-Group 9.11.07
6
EuP -> nach den Studien
2 0 0 6
2 0 0 7
2 0 0 8
2009
Boliers
Water heaters
Computers
Imaging
television, CE
Standby
Chargers
Office lighting
Street lighting
Room air
Motors
cold commer.
cold domestic
washing
Study phase
Consultation Forum phase
Regulatory Committee phase
Commission adoption phase
Heinz Beer
Trend-Watch-Group 9.11.07
draft final report stakeholder workshop
meeting of the Consultation Forum
vote by the Committee
Adoption by the Commission
7
Studien zu EuP 2006/2007
Nr
Produktgruppe (Originattext)
Contractor
Informationen
Verband
1
Boilers and combi-boilers
Van Holstein en Kemna B.V.
www.ecoboiler.org
FEA
2
Water heaters
Van Holstein en Kemna B.V.
www.ecohotwater.org
FEA
3
Personal Computers and Monitors
www.ecocomputer.org
SWICO
4
Imaging equipment
IVF Industrial R&D
corporation
Fraunhofer Inst. IZM, Berlin
www.ecoimaging.org
SWICO
5
Consumer electronics, TV
Fraunhofer Inst. IZM, Berlin
www.ecotelevision.org
SWICO
6
7
www.ecostandby.org
www.ecocharger.org
SWICO
SWICO
8
Stand-by and off-mode losses of EuPs Fraunhofer Inst. IZM, Berlin
Fraunhofer Inst. IZM, Berlin
Battery chargers and external power
supplies
Office lighting
VITO-Flemish Inst.
www.eup4light.net
SLG
9
(public) street lighting
VITO-Flemish Inst.
www.eup4light.net
SLG
10
Armines
www.ecoaircon.eu
FEA
AEA Technologies
www.ecomotors.org
12
Residential room conditioning
appliances
Electric motors, pumps, circulators,
ventilation fans
Commercial refrigerators and freezers
Bio Intelligence Service
www.ecofreezercom.org
swissT.
net
FEA
13
Domestic refrigerators and freezers
www.ecocold-domestic.org
FEA
14
Domestic dishwashers and washing
machines.
ISIS – Instituto die Studi per
l’integrazione dei Sistemi
ISIS – Instituto die Studi per
l’integrazione dei Sistemi
www.ecowet-domestic.org
FEA
Methodologie
VHK
http://www.eupproject.org
11
Heinz Beer
Trend-Watch-Group 9.11.07
8
EuP -> weitere Studien
Studie zu „einfachen“ Set To Boxes:
Contractor: MVV Energie AG, wird Ende November 2007 abgeschlossen.
www.ecostb.org
Tender from 22.12.2006. This Tender is subdivided into 7 lots.
The first 5 lots each correspond to a family of EuPs. Their numbering
continues the one started in previous ecodesign preparatory studies.
Lot 15: solid fuel small combustion installations (in particular for heating)
Lot 16: laundry dryers
Lot 17: vacuum cleaners
Lot 18: complex set top boxes (with conditional access and/or functions that
are always on): Contractor Bio Intelligent Service, Start Ende Oktober 07
► Lot 19: domestic lighting
►
►
►
►
The last 2 lots correspond to work on stakeholder representation.
► Lot C: Stakeholder representation: consumers
► Lot E: Stakeholder representation: environmental NGOs
Heinz Beer
Trend-Watch-Group 9.11.07
9
Vorgehen (Tasks)
Heinz Beer
Trend-Watch-Group 9.11.07
10
Heinz Beer
Trend-Watch-Group 9.11.07
11
Heinz Beer
Trend-Watch-Group 9.11.07
12
EuP: Consultation Forum
Consultation Forum
Leitung Stephan Kolb, DG TREN (mit DG ENV)
25 Politiker aus den Mitgliedsländern
25 NGOs. Agenturen, Orgalime, EICTA, CECED
2 Wochen vor Sitzung: öffentliches Papier mit Vorschlägen
Publikation durch Kommission
September
Strassenbeleuchtung
Oktober
Stand-by
Dezember
Prozess und Produkte
Januar 08
Power Supplies und Battery Charger
(Settop Boxes)
Heinz Beer
Trend-Watch-Group 9.11.07
13
EuP: Lot 3: Computer und Monitore
Resultat: Belastung der Umwelt durch:
Desktop
Energieverbrauch im Betrieb
Motherboard inkl. Prozessor (Core 2 bei Höchstleistungen)
Power Supplies (während der Produktion)
Steel - Gehäuse
Laptop
Energieverbrauch im Betrieb (aber Desktop brauchen 6 x mehr)
Motherboard inkl. Prozessor
Batterie? (Lithium-Ionen)
LCD
Energieverbrauch im Betrieb
Integrated circuits
Galvanized steel
Polyamid
CRT
Energieverbrauch im Betrieb
Integrated circuits
CRT-screen kaum mehr technische Verbesserungen
Assembling Board
Heinz Beer
Trend-Watch-Group 9.11.07
14
EuP: Lot 3: Computer und Monitore
Improvement options
Power Supply Unit
von 65% zu 80% average efficency mit 5 € Mehrkosten
Better Processors
24% sparen beim Desktop mit Mehrkosten von 10 €
12% sparen beim Laptop mit Mehrkosten von 15 €
Adaptive Clock frequency and similar (Throtteling)
17 % sparen bei Desktop, bei Laptop Stand der Technik
LED backlight screen
25% weniger Energy, 50 € Mehrkosten
Kein Quecksilber
Power Management
50% Energie sparen, keine Mehrkosten
Alle Produkte haben diese Möglichkeit, man muss sie nur nutzen
Unterscheiden zwischen Hardware und Software – Möglichkeiten, reine User-Gepflogenheiten gehören nicht in den Bericht
Lärm
In nordischen Ländern, wenn keine anderen Lärmquellen vorhanden sind, Problem ist die Kühlung, aber auch das Tippen!!
Giftige Substanzen
Leuchten am Lebensende entfernen (Quecksilber)
Flammhemmer
Einige werden in RoHS oder REACH behandelt
Batteries
Energieeffizienz, Alterung, toxische Substanzen, Gefahr der Explosion
Board assembly
Reduktion Materialeinsatz
Wiederverwendbares Material
Plastik oder Plastik von organischem Material (Cellulose)
Heinz Beer
Trend-Watch-Group 9.11.07
15
EuP, Lot 3 IMPLEMENTING MEASURES FOR
PCS (DESKTOPS & LAPTOPS)
SCOPE
In: Consumer, business, gamer, multimedia laptops & desktops
Out: Workstations, desktop derived servers, servers, storage
IMPLEMENTING MEASURES (IN ORDER OF LIKELIHOOD)
80% efficient internal power supply (at 20%, 50%, 80% and 100% of rated
output and Power Factor > 0.9 at rated output)
85% efficient external power supply (see also Implementing Measures for
EPS)
Power Management enabled (in line with E* 4.0): 30 minutes to sleep
Limits on sleep, off in line with E* 4.0: 4W/2W for DT, 1.7W/1W for LT
Information on energy consumption @ idle, sleep, off (at POS, sticker,
Internet?)
Limits on idle mode in line with E* 4.0: 50W/65W/9W for DT, 14W/22W for LT
TIMELINE
Draft IM
IM published
IM in force
Heinz Beer
Jan. 2008 (?)
earliest: Dec. 2008, realistic: Aug. 2009
earliest: Dec. 2009, realistic: Aug. 2010 (or Feb. 2011)
Trend-Watch-Group 9.11.07
16
Lot 3: IMPLEMENTING MEASURES FOR MONITORS
SCOPE
In: All monitors
Out: -
IMPLEMENTING MEASURES (IN ORDER OF LIKELIHOOD)
80% efficient internal power supply (at 20%, 50%, 80% and 100% of rated
output and Power Factor > 0.9 at rated output)
Power Management enabled (in line with E* 4.0): 15 min to screen off
(monitor sleep)
Limits on on mode/active power:
► Tier I: Y=38*X+30, where Y = active/on power [W], X = number of mega pixels in
decimal form. Only for monitors < 30”
► Tier II: Y=10+410*A, where Y = active/on power [W], A = “true” value of area of
screen [m2]
Limits on sleep, off in line with E*: 4W/2W
Information on energy consumption @ active, sleep, off (at POS, sticker,
Internet?)
TIMELINE
Draft IM
IM published
IM in force
Heinz Beer
Jan. 2008
earliest: Dec. 2008, realistic: Aug. 2009
earliest: Dec. 2009, realistic: Aug. 2010 (or Feb. 2011)
Trend-Watch-Group 9.11.07
17
Lot 3 & Lot 6
Are PCs and monitors in the scope of the IM on Standby?
Off-mode
PCs out, as the have “wake on LAN” capabilities
Monitors in
Lot 3
►Defines PC “off mode” without WoLAN as “off mode” (limits 2 ->1 W)
►Defines PC “off mode” with WoLAN as “passive standby” (limits 2.7->1.7 W)
Standby
PCs out, as “network standby”
Monitors out, as “network standby”
Lot 3
►Defines PC “network standby” as sleep (limits 4 -> 1.7 W)
Heinz Beer
Trend-Watch-Group 9.11.07
18
EuP: Lot 4: Imaging Equipment
Untersucht werden/wurden Ink-Jet und Laser-Printer
Stakeholdermeeting zu Task 1 – 7 am 24. Oktober 07
Umweltbelastung durch Energieverbrauch im Betrieb und vor allem
Papierverbrauch
Im Vergleich zu anderen Lots kleiner Verbrauch = tiefe Priorität
Problem Energieverbrauch in verschiedenen Zuständen und Geschwindigkeiten
Reduktion: Papiergewicht von 80 auf 60 g/m²
Studie zu Toner (Feinstaub) siehe SUVA-Bericht
Es folgt Task 8: Vorschläge für Massnahmen
Lot no.
Name
Annual electricity usage [TWh]
3
Personal Computer + Computers
42
4
Imaging Equipment
6.2*
5
Television
40
6
EPS and battery chargers
20
7
Office Lighting
26
8
Street Lighting
35
All household
765
Heinz Beer
Trend-Watch-Group 9.11.07
* as stated we
believe the actual
annual electricity
usage for imaging
equipment is
closer to 4 TWh
19
EuP: Lot 5: TV
Resulate
Technologische Entwicklung in 4 Gebieten:
von CRT zu Flachbildschirme
von kleinen Bildschirmen zu grossen
von analog zu digital
von Standard zu High Definition
Penetration in den Haushalten: von 1,45 (2005) auf 2.02 (2010)
Stand-by active in Zukunft wichtig, Vereinbarung zwischen Content-Anbieter und TVHersteller (z.B. EPG 3 x am Tag).
Umweltbelastung bei Herstellung und im Betrieb für Plasma und LCD etwa 1/10 bis 1/7
des Betriebs (ø Lebensdauer 10 Jahre)
Stand-by, bei kleinen Bildschirmen bis 15%, sonst Anteil klein.
Wichtig sind: Anzahl Lampen und Anpassung der Hintergrundbeleuchtung und die
Effizienz des Power Supplies.
Entwicklung: z.B. 42“ BAT Plasma (Betrieb): 2005, 330 W; 2006: 260 W; 2007: 204 W
Neue Technologien und Verbesserungen für Bildschirme, heute bei 2.0 lm/Inch, es
können 10 lm/Inch erreicht werden. Steigerung ~ 1 lm/Inch und Jahr, unabhängig ob
Plasma oder LCD. - LED, OLED und SED noch nicht bereit.
Schalter zum Abschalten ist nur nötig, damit Gerät nicht in Stand-by aktiv geht, bringt
sonst bei einem Wert unter 1W wenig.
Heinz Beer
Trend-Watch-Group 9.11.07
20
Heinz Beer
Trend-Watch-Group 9.11.07
21
Minimalanforderung
EuP: Lot 5: TV
400
350
300
Watt
250
200
150
100
50
Lot 5 ist abgeschlossen
Vorschläge Task 8:
0
15
20
25
30
35
40
45
50
55
Diagonale (Inch)
Freiwillige Vereinbarung für Minimalanforderungen der Hersteller an den
Stromverbrauch
Ein freiwilliges Label A-G:
► Stromverbrauch = Konstante + Faktor a x Bildschirmfläche (Konstante = 40 W für den
Receiver, Faktor a = 0.275 W/in2, Bildschirmfläche in Inch2.
► Zwischen G bis A werden Faktoren eingesetzt (G => 1, A => 0.5). Der Unterschied der
Stufen beträgt zirka 10%.
► Full HD TV-Geräte mit Plasmabildschirm wären heute alle in G, Rückprojektionsanlagen
erreichen problemlos A, daher sind nur Geräte mit gleicher Auflösung direkt vergleichbar.
Deklaration der Verbrauchszahlen in den Verkaufsunterlagen und den Betriebsanleitungen. Hinweis auf Quecksilber in den Leuchtmittel und auf Blei bei
Plasmabildschirme.
Minimalanforderungen für den Zustand „Aus“: 2010 ≤ 0.5W; 2012 ≤ 0.2 W
Minimalanforderungen für den Zustand „Stand-by passiv“: 2010 ≤ 1W; 2012 ≤ 0.5 W
Minimalanforderungen für den Zustand „Stand-by aktiv“: 2010 ≤ 3W; 2012 ≤ 2 W:
2015 ≤1 W
Download von Filmen ist ein aktiver Betriebszustand, das Gerät sollte nachher
selbstständig auf Stand-by schalten.
Termin Consultation Forum anfangs 2008
Heinz Beer
Trend-Watch-Group 9.11.07
22
EuP: Lot 6 (Stand-by und Off-Mode)
Electricity consumption in
mode (b)
Stock (a)
(million
units)
Product
TV+
PC+
Office
standby
(kW h/h)
off
(kW h/h)
standby
(h/year)
off
(h/year)
[line 214]
[line 216]
[line 215]
[line 217]
Television
0.2759
5.84
0
4380
0
Set-top-boxes
0.0563
10.7
0
7300
0
Destkop+notebook
0.0805
10.08
3.16
706.7
4363.3
Monitors
(CRT+LCD)
0.0445
6.89
1.24
876
5073.5
Hubs
0.0064
5
0
6570
0
126
14.02
3.3
1277.5
4901.4
104.5
4.71
1.5
826.2
3746.2
73
10.2
2.6
6653.7
1220.1
64.26
3.6
2.5
876
5329
Destkop+notebook
PC+
Home
Time in mode (c)
M onitors (CRT+LCD)
M odems
PC speakers
Heinz Beer
Trend-Watch-Group 9.11.07
23
Lot 6: (Stand-by und Off-Mode) Task 3
Average daily use times job-based products in households
Job based products in households
Product cases
Lot 6 Standby
mode time [h/d]
Off-mode losses
time [h/d]
0 Watt offmode time [h/d]
On mode
time [h/d]
Washing machine
3.0
20.0
0.0
1.0
DVD
15.6
4.0
3.8
0.6
Audio minisystem
17.1
1.4
2.1
3.4
Fax
23.1
0.0
0.0
0.9
Desktop/
Notebook (a)
3.5
13.4
5.9
1.2
Monitors (a)
2.3
10.3
10.3
1.2
PC speakers
2.4
14.6
6.4
0.6
Internet devices
(modems, incl.
WLAN)(b)
18.2
3.4
0.5
1.9
Printers, laser
1.9
13.1
8.9
0.1
Printers, inkjet
1.9
17.7
4.3
0.1
PC+
Heinz Beer
Trend-Watch-Group 9.11.07
24
Lot 6: (Stand-by und Off-Mode) Task 5
Annual losses of the stock in mode
Lot 6 Standby
PUC
Off
Passive
standby
Networked
standby
Total
Standby
Total per
product case
(TWh)
(TWh)
(TWh)
(TWh)
(TWh)
EPS (mobile phone)
0.85
0.00
0.00
0.00
0.85
Lighting
1.90
0.00
0.00
0.00
1.90
Radio
0.72
0.00
0.00
0.00
0.72
Electric toothbrush
0.52
0.00
0.00
0.00
0.52
TOTAL
3.99
0.00
0.00
0.00
3.99
Oven
0.00
1.90
0.00
1.90
1.90
Cordless phone
0.00
0.00
3.71
3.71
3.71
TV+
0.00
0.00
11.45
11.45
11.45
TOTAL
0.00
1.90
15.17
17.07
17.07
Washing machine
1.62
1.15
0.00
1.15
2.77
DVD
0.31
3.92
0.00
3.92
4.23
Audio minisystem
0.09
5.71
0.00
5.71
5.80
Fax machine
0.00
0.00
0.99
0.99
0.99
PC+ (office)
1.39
0.00
1.05
1.05
2.44
PC+ (home)
3.71
0.00
7.82
7.82
11.53
Laser printer
0.26
0.00
0.71
0.71
0.97
Inkjet printer
1.75
0.00
0.38
0.38
2.12
TOTAL
9.12
10.78
10.96
17.79
30.86
13.12
12.68
26.12
38.81
51.93
Product case
1
2
3
Lot 6 Total per mode (TWh)
Heinz Beer
Trend-Watch-Group 9.11.07
25
The energy consumption
of TV+ and PC+ were
updated, which effects the
overall energy
consumption as well as
the relative distribution of
the energy consumption
between the PUC‘s.
According to this, most
figures in Section 5.3
were changed slightly.
Lot 6: Base Case 1 – Off-mode Losses
Laser printer
2%
Inkjet printer
13%
EPS (mobile
phone)
7%
Lighting
15%
Radio
5%
Electric toothbrush
4%
PC+ (Home)
28%
PC+ (Office)
11%
Audio minisystem
1%
DVD
2%
Washing machine
12%
Total off-mode losses per year covered by the 15 product cases:
13.1 TWh or 1779 million € electricity costs (EU-25 stock 2005)
Heinz Beer
Trend-Watch-Group 9.11.07
26
Lot 6: Base Case 2 – Standby Function Cluster
PC+ (Home)
19%
Laser printer
2%
Inkjet printer
1%
Oven
5%
Cordless phone
10%
PC+ (Office)
3%
TV+
29%
Fax machine
3%
Audio minisystem
15%
Washing machine
3%
DVD
10%
Total off-mode losses per year covered by the 15 product cases:
39 TWh or 5266 million € electricity costs (EU-25 stock 2005)
Heinz Beer
Trend-Watch-Group 9.11.07
27
Lot 6: Annual Standby and Off-mode Electricity
Consumption (EU-25 stock, 2005)
Share of product cases (all modes) - Lot 6 stock
Laser printer
2%
EPS (mobile
phone)
2%
Inkjet printer
Lighting
4%
4%
PC+ (Home)
22%
Radio
1% Electric toothbrush
1%
Oven
4%
Cordless phone
7%
PC+ (Office)
5%
Fax machine
2%
Audio minisystem
11%
TV+
22%
DVD
8%
Washing machine
5%
PC+(home) and TV+ are the largest contributors (22%
each) for EU-25 stock 2005 in both modes
Heinz Beer
Trend-Watch-Group 9.11.07
28
Lot 6: Summary of all Contributions
Rest (networked
standby)
2%
Fax machine
2%
PC+ (Office)
2%
PC+ (Home)
7%
Inkjet printer
3%
Lighting
4%
Washing machine
3%
Cordless phone
7%
PC+ (Home)
15%
PC+ (Office)
3%
Off-mode
EPS (mobile phone)
2%
Networked
standby
Rest (off-mode)
4%
Passive
standby
TV+
22%
Washing machine
2%
Oven
4%
Audio minisystem
11%
DVD
8%
Total per year covered by the 15 product cases:
52 TWh or 7045 million € electricity costs (EU-25 stock 2005)
Heinz Beer
Trend-Watch-Group 9.11.07
29
Heinz Beer
Trend-Watch-Group 9.11.07
30
Heinz Beer
Trend-Watch-Group 9.11.07
31
Lot 7: Power Supplies und Battery-Charger
Lot abgeschlossen
Code of Conduct hat sich bewährt
Effizienz (< 85%) über den ganzen Ladebereich für
externe Power Supplies
Standardisierung, d.h. Ladegerät für mehrere
Produkte und/oder mehrere Generationen, um
Material einzusparen (aber: Sicherheit und
Effizienzsteigerung)
Assessment durch PCW, Milan, in Arbeit
Consultation Forum im Januar 08 (Papier dazu im
Dezember)
Heinz Beer
Trend-Watch-Group 9.11.07
32
EuP -> weitere Studien
Studie zu „einfachen“ Set To Boxes: Contractor: MVV Energie AG,
soll nach 6 Monaten, d.h. Mitte 2007 abgeschlossen sein.
Tender from 22.12.2006. This Tender is subdivided into 7 lots.
The first 5 lots each correspond to a family of EuPs. Their numbering
continues the one started in previous ecodesign preparatory studies.
► o Lot 15: solid fuel small combustion installations (in particular for heating)
► o Lot 16: laundry dryers
► o Lot 17: vacuum cleaners
► o Lot 18: complex set top boxes (with conditional access and/or functions
that are always on)
► o Lot 19: domestic lighting
The last 2 lots correspond to work on stakeholder representation. In
order to better differentiate them, their references are letters, not
numbers.
► o Lot C: Stakeholder representation: consumers
► o Lot E: Stakeholder representation: environmental NGOs
Heinz Beer
Trend-Watch-Group 9.11.07
33
Lot: Simple Settop Boxes
Task 1 – 7 abgeschlossen, Task 8 (Vorschläge für Massnahmen) wird erwartet bis zirka 15 November 07
Stakeholder Meeting am 17.10.07
Bei einfachen STB liegt die grösste Umweltbelastung beim Stromverbrauch während der 5-jährigen
Lebensdauer. Besonders hoch ist der Verbrauch bei STB mit Harddisk. Produktion, Material, Vertrieb und
Recycling haben nur einen (sehr) kleinen Umwelteinfluss.
STB
STB mit Harddisk
Stromverbrauch Stand-by (W) 1,2)
Stromverbrauch on (W) 1)
Zeit im Betrieb (h/Tag)
Zeit im Stand-by (h/Tag)
Stromverbrauch pro Jahr (kWh)
6.1
7.0
4.0
20.0
54.75
5.9
25.6
8.0 3)
16.0
108.976
1) Verkaufsgewichtete Durchschnittswerte aus Deutschland und England, 2) tiefster Wert: 3.4 W
3) Wert zu hoch, als Maximalwert i.o., richtig wäre 1h, denn nur 20 – 25% nutzen die Recorder-Funktion
Einfache STB boomen bei der Einführung des digitalen Fernsehens, werden jedoch obsolet, wenn die TVGeräte digital sind (zirka 5 Jahre nach Abschalten der analogen Sender). Dann werden die Anbieter STB mit
zusätzlichen Funktionen auf den Markt bringen. Schnelles Handeln ist deshalb nötig. STB Funktionen
(Analog/Digital–Wandler) sind heute bereits in preisgünstigen DVD-Player auf dem deutschen Markt (Player,
nicht Recorder!).
Die besten Geräte sollen bereits heute 5 W im Betrieb und 0.25 W im passiven Stand-by erreichen. Dies ist mit
Chiptechnologie, einer entsprechenden Software und dem Einsatz effizienter Power Supplies möglich. Die
Entwicklungszeiten mit Printplatten waren/sind lang, mit Siliziumtechnologie sehr schnell, daher werden bis in
zwei Jahren alle angebotenen STB diese tiefen Werte erreichen. Die Silizium-Technologie ist nicht teurer =
kompakte Geräte.
STB müssen als ganzes, d.h. mit den Power Supplies zusammen gemessen werden. Allfällige Werte für STB
müssen höher sein, als für Power Supplies allein. Effiziente Power Supplies sind heute z.B. für Mobiltelefone
vorhanden.
Die Entwicklung des hochauflösenden Fernsehen (HD ready, Full HD) muss berücksichtigt werden. Eine
Messnorm, welche In- und Output der Signale einkalkuliert, ist in Diskussion.
Heinz Beer
Trend-Watch-Group 9.11.07
34
Die SD-STB (Modell: KCF-H200SCO)
sowie die HD-STB (Modell: KCFS660HDCO) werden ca. ab Februar
2008 ausschliesslich als „GREEN
LINE“ STBs mit unter einem Watt ( <
1 Watt) im Passiv-Standby an unsere
Kabelnetzkunden ausgeliefert
Wichtig: Den Aktiv-Standby sehen
wir als nicht nötig und haben diesen
nicht mehr implementiert
Anbei die beiden Spezifikationen der
Geräte
Bemerkung: Diese beiden Kaon
Media STB-Modelle (mit Conax
embedded) werden zur zeit an
praktisch alle Kabelnetzbetreiber in
der Schweiz ausgeliefert (Cablecom
ausgeschlossen, da diese spezielle
Versionen von der „Mutterfirma“
UPC bezieht)
Heinz Beer
Trend-Watch-Group 9.11.07
35
EuP -> Revision
Meeting der EU-Umweltminister 1-3. Juni 07, Essen
European Top Runner
Produkte mit hohem Einfluss auf die Ökologie
Produktstandard, orientiert sich an den Besten (BAT)
In Europa fehlen Daten, wie Sie in Japan vorhanden sind
für den Energieverbrauch, gefährliche Substanzen, Lärm,
einfaches Recyclieren, sowie biologische Abbaubarkeit
Forum für Marktinstrumente der einzelnen Länder
Environmental Technology Action Plan (ETAP)
Green Public Procurement (GPP)
16% des Einkaufsvolumens durch die öffentliche Hand
Green Lead Markets
Sustainable Energy Technologies
Heinz Beer
Trend-Watch-Group 9.11.07
36
GreenLabelsPurchase
http://www.greenlabelspurchase.net
Projekt Partner:
Europäische Kommission, Generaldirektion Energie und Transport. Die Abteilung
Energie ist u. a. für das IEE Programm verantwortlich.
http://ec.europa.eu/energy/index_en.html
Europäische Kommission, Intelligent Energy Executive Agency (IEEA)
Die IEEA (Intelligent Energy Executive Agency) implementiert das IEE Programm
in Europa. Mit mehr als 40 Mitarbeiterinnen und Mitarbeitern betreut die Agentur
die Projekte und Veranstaltungen des IEE Programmes. Sie ist zuständig für die
Verbreitung der Ergebnisse und organisiert die Ausschreibungen der einzelnen
Projektrunden.
Europäische Kommission, Programm Intelligente Energien für Europa
Europas Aktionsprogramm für Erneuerbare Energie und Energieeffizienz
Hinter dem sperrigen Kürzel "IEE" - abgeleitet vom französischen Programmtitel
"Énergie intelligente - Europe"- verbirgt sich ein Programm der EU mit 200
Millionen Euro, die für Projekte zur Verfügung gestellt werden. Die Projekte
widmen sich der Beseitigung von nicht-technischen Hemmnissen zur stärkeren
Marktdurchdringung von Technologien zur Nutzung erneuerbarer Energieträger
und der rationellen Energieverwendung.
http://ec.europa.eu/energy/intelligent/index_en.html
Heinz Beer
Trend-Watch-Group 9.11.07
37
Abkommen EU-EPA zu Energy Star
Verlängerung bis 2010 beschlossen und am 6.10.06
publiziert, am 24.12.06 unterzeichnet
Für IT und Office Equipment
Anfrage/Diskussion im EU-Parlament über bessere
Nutzung in der EU (April/Juni 07), Beschluss Consul fehlt ?
Minimalanforderung in der öffentlichen Beschaffung
Bekanntmachen des Labels
Weiterführen der Datenbanken
Reporting des ECESB (European Community Energy Star Borad)
über Marktanteile
Weitere Produkte
Messmethode, wo keine Norm vorhanden
Heinz Beer
Trend-Watch-Group 9.11.07
38
Open Ended scale using Numbers
More efficient
9
9
9
8
7
8
7
8
7
6
6
6
5
5
4
5
4
3
4
3
2
3
2
1
2
1
Less efficient
• Vorschlag von CECED an die EU-Kommission
• Seven colored strips, from least efficient to most efficient
• Dynamically accommodating higher efficiency technologies beyond Top Class
•
•
New classes are created every time top is populated by X% of the market
New future class thresholds are predictable as calculated as % of previous threshold
Heinz Beer
Trend-Watch-Group 9.11.07
39
1
Vorschlag für (neues) Label
9
8
7
6
5
4
3
2
1
Alte Regelung seit 1994
Vorschlag noch nicht publiziert (-> Mitte Nov. 07)
Label A – G durch Label 1 – 7 ersetzen
Wenn x % der Produkte im Verkauf in höchster Klasse,
automatisch neue Klasse mit z.B. 10% tieferen Werten
Die Zahlen bleiben, die Farbe ändert.
Unklar, ob Buchstaben oder Zahlen für die weiteren Eigenschaften
(z.B. Schleuderwirkung)
Eignet sich nur für Produkte mit rel. langsamer Verbesserung
(sonst hohe Zahlen)
Bei Umstellung (heute A++ = „altes“ B); A soll noch leer sein
Heinz Beer
Trend-Watch-Group 9.11.07
40
IPP: Pilotstudie Mobiltelefone
1. Phase wurde Ende Mai 2006 abgeschlossen
Pilot Project Stakeholder Group
Mobile phone producers: Nokia, Motorola, Panasonic
Component manufacturers: Epson, Intel, AMD, Spansion
Governmental Organisations: UK Defra, European Commission
Research Institute: Finish Environmental Institute
Telecom Operators/Retailers: Teliasonera, France Telecom/Orange, Vodafone
Recyclers: Umicore
NGOs: WWF
Consumers: BEUC
Schlussfolgerungen, 6 weitere Schritte bis Ende Oktober 07:
Fakten der Produkte und bekannt geben: Eco-Deklaration (Nokia)
Reduktion Energieverbrauch in Betrieb der Ladegeräte (wenn diese nicht laden),
dies mache 30% des Verbrauchs aus (Nokia)
Reduktion giftiger Substanzen (Epson).
Rücknahme, Recycling, bzw. Wiederverwendung (Vodafone)
Methoden des Vorgehens beschreiben (SYKE)
Einsatz solcher Studien als politisches Instrument (EU)
Heinz Beer
Trend-Watch-Group 9.11.07
41
Weitere Arbeiten in der EU
Normen und Messmethoden für Stand-by aktiv, passiv, On..
(CENELEC, CEN…)
Information für den Konsumenten: Eco-Declaration
EU-U.S.: Summit Statement Energy Security, Efficiency, and Climate
Change
Initiative der Industrieverbände: CEA, EICTA, ITI, JEITA
We will ensure that global industry standards are established for
measuring the active and standby power consumption for ICT/CE
products.
Our industry develops a global standard for conveying product energy
usage information to consumers, which is also acceptable to policy
makers.
We set an industry sectoral goal for future energy consumption, which is
also acceptable to policy makers, and establish energy efficiency design
principles supporting that goal.
Heinz Beer
Trend-Watch-Group 9.11.07
42
Zusammenfassung EU: in Arbeit
Massnahmen aufgrund der abgeschlossenen EuP Studien
Analyse einfacher Settop Boxes (EuP)
Weitere Studien zu EuP in 2007
Beschluss über das weitere Vorgehen zu EuP in Consulting Forum
Directive ESD (beschlossen 5. April 2006)
Umsetzen in den Ländern bis 17. Mai 2008
minus 1% Energieverbrauch pro Jahr
EEAP: Energy Efficiency Action Plan der Länder
► Basis ø 1998 – 2002
► Ziel 2016 mit Zwischenziel 2011
► Bisherige Massnahmen teilweise anrechenbar
► GB will 18 % erreichen
EU will Messkriterien zur Effizienz festlegen
Direktive IPP
Sustainabilty Campaign
Action plan (- 3 x 20 bis 2020)
CoC
Initiativen
Label, Information an die Konsumenten
Heinz Beer
Trend-Watch-Group 9.11.07
43
Danke
Heinz Beer
Trend-Watch-Group 9.11.07
44

Documentos relacionados