Installation Note - Bosch Security Systems
Transcrição
Installation Note - Bosch Security Systems
EN 54-16 en Installer checklist EN 54-16 Table of Contents | en 3 Table of contents 1 Emergency Sound System 4 2 List of authorized end-users 6 3 EN 54-16 7 3.1 4 General requirements 7 3.2 5 General requirements for indications 9 3.3 6 The quiescent condition 11 3.4 7 The voice alarm condition 11 3.5 8 Fault warning condition 14 3.6 10 Voice alarm manual control (option with requirements) 21 3.7 11 Interface to external control device(s) (option with requirements) 23 3.8 12 Emergency microphone(s) (option with requirements) 23 3.9 13 Design requirements 24 3.10 14 Additional design requirements for software controlled VACIE 38 3.11 15 Marketing 44 3.12 16 Tests 44 Installer checklist 21-Sep-2015 | 01 | 4 en | Emergency Sound System 1 EN 54-16 Emergency Sound System BOSCH has made a great effort for the design and manufacturing of the components and also supplies all documentation that enables the assembly of a safe and high quality emergency unit in accordance with EN 54-16. BOSCH has made up this list of requirements, based on the standard, which needs to be filled in and subsequently signed off by both parties. The signed paper has the nature of a certificate and can have significant meaning in the case of a legal investigation of the liability issue for personal injuries. – The safety of the system in accordance with EN 54-16 in an alarm and emergency application does not only depend on component safety, but also highly on the installation engineer and the operator. For example, the sound pressure level of the system depends on the installation. Moreover, the system should only be installed and operated by qualified personnel. – Modifications of the system should only be executed by authorized persons in accordance with the safety concept and need to be registered in the system documentation. – If EN 54-16 devices and non-EN 54-16 devices (e.g. a CD player for background music) are assembled in one cabinet, it must be marked which devices belong to EN54-16 and which devices do not. – Only use a UPS compliant to the current standards and legislation in combination with – The end-user must maintain a journal for the system. – The installer is responsible for security measures to prevent improper use of the system. – BOSCH refuses any liability for damage that might result from non-observance of these the PAVIRO System. instructions. – The installer has to ensure that he uses certified firmware running on the devices. Information, which firmware versions are applicable can be seen at the web page. Notice! The EN 54-16 is a standard referring to products, for an installation the project-depending country-specific standards must be observed. 21-Sep-2015 | 01 | Installer checklist Emergency Sound System | en EN 54-16 5 Herewith the undersigned states that he/she has processed for him/her applicable requirements, as specified in this document, in an adequate way and has confirmed this fact by signing the right most column of each requirement. Installer End-User Name _____________________ Name _____________________ Signature _____________________ Signature _____________________ Date _____________________ Date _____________________ Place _____________________ Place _____________________ The installer is only allowed to affix a VACIE label on the applied cabinet of a PAVIRO system, wherein the controller has been installed, after the installer has completed, dated and signed the checklist for EN 54-16 and has clearly indicated on the VACIE label the year in which the VACIE label actually has been affixed on the cabinet. A copy of the completed checklist is to be returned to the regional Bosch office. To ensure compliance to classification IP30 of EN 60529, make sure that the selected cabinet is compliant, and also pay attention to cable glands, ventilation grilles and connection to the wall. Keep in mind that access to the controlling and indicating equipment (e.g. PVA-15CST) is access level 2 (protected by a lock) and that the rear of the equipment is access level 3 (protected by a different or additional lock). Racks that are allowed within this EN54-16 system certification are listed on the original certificate. Please refer to this certificate to ensure the correct rack is used and refer to the manufacturer's site, instructions for use and sales technicians for information on correct IP30 compliant mounting and accessories that are needed to safeguard all aspects of the selected rack. The installer must ensure that all open areas and holes of the used racks which do not comply with IP30 are closed. Use compatible cable glands, climate control, etc. Calculate ample climate control (temperature dependent ventilation) for the rack and charger(s). Order the fan pack with thermal control. Installer checklist 21-Sep-2015 | 01 | 6 en | List of authorized end-users 2 21-Sep-2015 | 01 | EN 54-16 List of authorized end-users Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Name: _____________________________ Installer checklist EN 54-16 3.1 4 General requirements Clause/Requirement EN 54-16:2008 EN 54-16 3 Compliance 4 General requirements 4.1 General 4.1.1 If an optional function with requirements is The following optional functions, with requirements, are included in the VACIE, then all the included in PAVIRO from software Version IRIS-Net corresponding requirements shall be met. V3.0.0 upwards – Audible warning (7.3) – Phased evacuation (7.5) – Manual silencing of the voice alarm condition Signature Installer checklist (7.6.2) – Manual reset of the voice alarm condition (7.7.2) – Voice alarm condition output (7.9) – Indication of faults related to the transmission path to the CIE (8.3) – Indication of fault related to voice alarm zones (8.4) – Voice alarm manual control (10) – Emergency microphone(s) (12) – Redundant power amplifiers (13.14) The following optional functions with requirements are not included in PAVIRO and are not used: Delay(s) to entering the voice alarm condition (7.4) – Output to fire alarm devices (7.8) – Disabled condition (9) – Interface to external control device(s) (11) The installer has to ensure that additional functions like this European Standard are provided, they background music do not influence compliance. For shall not jeopardize compliance with any other functions such as announcements, chimes or requirements of this European Standard. stored messages the priority must be observed. 7 21-Sep-2015 | 01 | If functions other than those specified in EN 54-16 | en 4.1.2 – Combined VACIE and CIE Signature No signature en | EN 54-16 4.2 Compliance 8 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 necessary in this line. When the VACIE and CIE are combined they No signature may share common indications, manual necessary in this line. controls and outputs (see Annex F). In this case, the following shall apply: a) a single fault in the CIE shall not adversely The installer has to ensure to configure the system affect the mandatory functions of the VACIE; accordingly. b) indication(s) and manual control(s) of the Indications and controls are not shared. voice alarm condition shall be clearly identifiable, with the exception of the optional audible warning. Installer checklist 4.3 Power supply Power supply equipment, external or It is the responsibility of the installer to use power included in the VACIE, shall comply with the supplies and battery charging equipment in accordance requirements of EN 54-4. with EN 54-4. The installer has to ensure that the NOTE The power supply may be shared with capacity of power supplies operates with sufficient that of the fire detection and fire alarm headroom. system. The power supply may be shared with that of a fire detection system, but when operated with a battery the fire detection and the fire alarm system must be included into the capacity calculation. EN 54-16 5 General requirements for indications Clause/Requirement EN 54-16:2008 Compliance 5.1 Display and functional conditions 5.1.1 The VACIE shall be capable of The emergency CALL STATIONs indicate the "voice unambiguously indicating the following alarm condition" (must be configured) with the red functional conditions, as described in LED (Alarm) and the "fault warning condition" with Clauses 6 to 9: the yellow LED (Fault). If both LED are off the – quiescent condition; system is in the "quiescent condition" and the green – voice alarm condition; LED (Power) must be on. – fault warning condition; The PAVIRO system does not support the – disablement condition (option with „disablement condition“. requirements) The installer has to ensure that the system provides Signature EN 54-16 3.2 the required indications. This can be solved e.g. by including a CALL STATION. Installer checklist 5.1.2 The VACIE shall be capable of being The PAVIRO system is capable of being simultaneously in any combination of the simultaneously in the „voice alarm condition“ and in this line. No signature necessary in following functional conditions on different the „fault warning condition“. voice alarm zones: 5.2 – voice alarm condition; – fault warning condition; Indications displays All mandatory indications shall be clearly Mandatory indications are clearly identifiable by No signature necessary in identifiable, except where otherwise system default. this line. specified in this European Standard. 5.3 Indication on alphanumeric displays EN 54-16 | en 9 21-Sep-2015 | 01 | Where an alphanumeric display is used to The LC display of the emergency CALL STATIONs display indications relating to different indicates status conditions and fault details of the functional conditions these may be system. displayed at the same time. However, for If a fault occurs in the system, the faults are Signature en | EN 54-16 Compliance 10 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 each functional condition there shall be only displayed automatically. The information related to one window, in which all of the information emergency has precedence over the faults relating to that functional condition is information. grouped. Note: See chapter 8. 5.4 Indication of the supply of power 5.4.1 A visible indication shall be given by means Each PAVIRO system component has a green power of a separate discrete light-emitting LED. The LED is on when the component is supplied this line. indicator while the VACIE is supplied with with power. No signature necessary in power. Installer checklist 5.4.2 Where the VACIE is distributed in more than Each PAVIRO system component has a green power one cabinet, an indication of supply of LED. The LED is on when the component is supplied this line. No signature necessary in power to each distributed cabinet shall be with power. given at that point. 5.5 Additional indications Where additional indications are provided, All of the additional indications are clearly identified No signature necessary in they shall be clearly identifiable and shall (description in the User manuals of the PAVIRO not override the primary indication of the system); since the fault warning indication and the VACIE. voice alarm indication always do have separate this line. indicators, the primary indications are not overridden. The display of the CALL STATION offers a menu that is also used for other indications than indication of the voice alarm and/or fault warning condition. The Installation and User Instructions of the PAVIRO system CALL STATIONs clearly identifies the other indications of the menu. The other menus do not override the emergency and EN 54-16 faults information. 6 The quiescent condition Clause/Requirement EN 54-16:2008 6 Compliance Signature EN 54-16 3.3 The quiescent condition Any kind of system information may be All of the additional indications are clearly identified No signature necessary in displayed during the quiescent condition. (description in the User manuals of the PAVIRO However, no indications shall be given which system); since the fault warning indication and the could be confused with indications used in the voice alarm indication always do have separate – voice alarm condition indicators, the primary indications are not – fault warning condition overridden. – the disablement condition (option with this line. requirements). 3.4 7 The voice alarm condition Installer checklist Clause/Requirement EN 54-16:2008 Compliance 7.1 Reception and processing of fire signals 7.1.1 The VACIE shall be capable of receiving and The installer has to ensure the maximum 3 second processing alarm signals from the CIE or from delay time is observed. manual control on the VACIE or both, and Note: Task Engine Debounce/Timer/Supervision causing the appropriate voice alarm outputs to Block Signature be activated within 3 s or on expiry of any delay period (see 7.4). 7.1.2 The mandatory indications and or outputs shall The PAVIRO system offers 100 discrete priorities. not be falsified by multiple alarm signals Correct configuration assures that mandatory received simultaneously from the CIE and/or indications, and outputs behave consistently when manual controls. multiple alarm signals are received simultaneously from the CIE and/or manual controls. EN 54-16 | en 11 21-Sep-2015 | 01 | Where the VACIE and CIE are in separate PAVIRO is an autonomous subsystem that can cabinets, failure of the transmission path operate without connection to the CIE. The effect between the CIE and the VACIE shall not result of the failure of the transmission path between in any loss of control or any change of state of the CIE and the PAVIRO system is limited to fault the VACIE. reporting and losing interaction between the CIE Signature en | EN 54-16 Compliance 12 21-Sep-2015 | 01 | 7.1.3 Clause/Requirement EN 54-16:2008 and the PAVIRO system. The installer has to ensure that a fault of the transmission path starts or stops an alarm signal/alarm message. 7.2 Indication of the voice alarm condition 7.2.1 The presence of a voice alarm condition shall be No signature indicated on the VACIE, without prior manual necessary in this line. intervention, by: Installer checklist a) a visible indication by means of a separate A voice alarm condition is indicated on the PAVIRO discrete light emitting indicator (the General system by a red LED (Alarm) indicator on all Voice Alarm Activated indicator) and emergency CALL STATIONs. The installer has to ensure to configure the alarm condition accordingly. b) a visible indication for each activated voice The red zone LED's on the emergency CALL alarm zone where manual controls are provided STATION indicates activated voice alarm zones (see 10.2); NOTE This may be by means of separate discrete No signature indicators or an alphanumeric display as necessary in this line. specified in 13.8. 7.3 Audible warning (option with requirements) The emergency CALL STATION uses for audible warning a different frequency than for fault warning. Audible warning has a higher priority than fault warning. Note: Regarding the sound pressure level see requirement 13.10.2. Phased evacuation (option with requirements) EN 54-16 7.5 Compliance The VACIE may have a provision to phase the Phased evacuation is possible by using different warning signals to the emergency loudspeaker control contacts from CIE. Every contact zones. The facility shall be configurable at repesents an emergency zone. The installer has to access level 3. There may be provision to switch ensure to configure the correct settings at the on and switch off the phased evacuation PVA-4CR12 "PAGINGS" dialog. If a system needs sequence by means of a manual operation at the provision to switch on and switch off the access level 2 (see Annex A for information on phased evacuation sequence by means of a access levels). manual operation the installer has to configure the Signature EN 54-16 Clause/Requirement EN 54-16:2008 Task Engine accordingly. We suggest to label the button with "P-EVAC OFF". 7.6 Silencing of the voice alarm condition 7.6.1 Silencing of the voice alarm condition from the No signature CIE necessary in this line. Installer checklist 7.6.1.1 7.6.1.2 Where the voice alarm condition has been Voice alarm triggered from the CIE can also be triggered from the CIE, the VACIE shall respond silenced from the CIE. The installer has to ensure appropriately to a silence instruction from the to configure the system according the CIE. requirement. The silencing procedure may allow for the The silencing will be done immediately or after completion of messages in the process of being being broadcasted. broadcast. 7.6.2 Manual silencing of the voice alarm condition It may be possible to manually silence the voice The installer has to configure the system alarm message from the VACIE at access level 2. accordingly. In this case, following manual silencing, it shall be possible to re-activate the voice alarm message at access level 2. Reset of the voice alarm condition 7.7.1 Reset of the voice alarm condition from the CIE No signature necessary in this line. EN 54-16 | en 13 21-Sep-2015 | 01 | 7.7 Signature Where the voice alarm condition has been The installer has to ensure that a separate input triggered from the CIE, the VACIE shall respond from the CIE is configured for resetting the alarm appropriately to a reset instruction from the CIE. condition. 7.7.2 7.7.2.1 Manual reset of the voice alarm condition No signature (option with requirements) necessary in this line. It shall be possible to reset the voice alarm The installer has to ensure to configure a separate condition from the VACIE at access level 2 by CALL STATION button to reset the voice alarm en | EN 54-16 Compliance 14 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 means of a separate manual control. This control condition. This manual reset function must have a shall be used only for reset and may be the same higher priority than the CIE contact. as that used for reset from the fault warning condition. 7.7.2.2 Following a reset operation, the indication of the After a reset operation, the PAVIRO system will Installer checklist correct functional condition corresponding to immediately indicate the functional condition it is any received signals shall either remain or be re- currently in. It will also immediately respond to established within 20 s. received signals that will bring it into another functional condition. The installer has to ensure not to add to much delay. 7.9 Voice alarm condition output (option with requirements) The VACIE may have provision for transmitting a The installer has to ensure that the PAVIRO system signal that is in the voice alarm condition. In this transmits a signal that it is in the voice alarm case, it shall activate the output only in the voice condition via control output contact which has to alarm condition. 3.5 be configured. 8 Fault warning condition Clause/Requirement EN 54-16:2008 8 Fault warning condition 8.1 Reception and processing of fault signals Compliance Signature EN 54-16 8.1.2 8.1.3 Compliance The VACIE shall enter the fault warning When the PAVIRO system receives a supervision condition when signals are received which, fault signal (i.e. detects a fault in the system), the after any necessary processing, are fault warning condition is entered. The installer has interpreted as a fault. to ensure that faults are configured accordingly. The VACIE shall be capable of The installer has to ensure to include only fault simultaneously recognizing all of the faults messages into the fault handling. specified in 8.2 and, if provided, in 8.3 The PAVIRO system is capable of recognizing all of unless this is prevented by: its system faults simultaneously. The PAVIRO system – the presence of an alarm output signal is able to recognize faults in a voice alarm zone even on the same voice alarm zone when there is an alarm output signal on the zone. The VACIE shall enter the fault warning The PAVIRO system recognizes and reports all faults condition within 100 s of the occurrence of within the time defined in EN 54.The installer has to Signature EN 54-16 8.1.1 Clause/Requirement EN 54-16:2008 any fault, or the reception of a fault signal or ensure that faults are configured accordingly. Installer checklist within another time as specified in this European Standard or in other parts of EN 54. 8.2.1 The presence of faults in specified functions No signature necessary in shall be indicated on the VACIE without this line. prior manual intervention. The fault warning condition is established when the following are present: a) a visible indication by means of a The PAVIRO system provides a visible indication separate light emitting indicator (the general when it is in the fault warning condition via the fault warning indicator); yellow LED (Fault) of the emergency CALL STATIONs, and via the yellow front panel LED (Fault) of the PAVIRO CONTROLLER. The PAVIRO system offers visual indication of fault as specified in 8.2.4, and 8.2.5, 8.2.6, individual faults at the LC display or via additional 8.2.7, if provided, and 8.3; LEDs on emergency CALL STATIONS. EN 54-16 | en 15 21-Sep-2015 | 01 | b) a visible indication for each recognized c) an audible indication, as specified in 8.4. The PAVIRO system provides an audible fault Signature en | EN 54-16 Compliance 16 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 indication when it is in the fault warning condition via sounder at the emergency CALL STATION. In case of CALL STATION fault it additionally indicates the fault warning condition via sounder at the PAVIRO CONTROLLER. 8.2.2 If the indication is on an alphanumeric No signature necessary in display, which cannot simultaneously this line. indicate all of the faults because of its limited capacity, at least the following shall apply: Installer checklist a) the presence of fault indications which The first line shows the total quantity of active have been suppressed shall be indicated; faults, the other lines indicate fault details. b) suppressed fault indications shall be The next error is displayed each time you press the No signature necessary in capable of being displayed by means of a (ESC) fault button. After the last error, the display this line. manual operation at access level 1 or 2 begins again from the beginning. which interrogates only fault indications. 8.2.3 The following faults shall be indicated by No signature necessary in means of separate light emitting indicators this line. and/or an alphanumeric display: a) an indication at least common to any The installer has to ensure that all Power faults are power supply fault resulting from: indicated on the LCD of the emergency CALL 1) a short circuit or an interruption in a STATION. transmission path to a power supply (item L of Figure 1 of EN 54-1), where the power supply is contained in a different cabinet from that of the VACIE, and 2) the power supply faults as specified in EN 54-4; EN 54-16 Compliance b) an indication at least common to any The installer has to ensure that all Ground faults earth fault of less than 50 kΩ which is from the amplifier outputs are indicated on the LCD capable of affecting a mandatory function, of the emergency CALL STATION. Signature EN 54-16 Clause/Requirement EN 54-16:2008 and which is not otherwise indicated as a fault of a supervised function; c) an indication of the rupture of any fuse Every rupture of a fuse or the operation of a within the VACIE, or the operation of any protected device that affects a mandatory function protective device within the VACIE which is will result in a fault since the mandatory functions capable of affecting a mandatory function in are supervised. the fire alarm condition; Installer checklist d) an indication of any short circuit or The installer has to ensure that the transmission interruption, at least common to all paths between the cabinets are supervised if the transmission paths between parts of the cabinets used for one system are not mounted in VACIE contained in more than one cabinet, one room. which is capable of affecting a mandatory function and which is not otherwise indicated as a fault of a supervised function. 8.2.4 Note: These indications from 8.2.3 may be No signature necessary in suppressed during the fire alarm condition. this line. The following faults shall be indicated at No signature necessary in least by means of the general fault warning this line. indicator: a) any short-circuit or interruption in a voice The installer has to ensure that the transmission alarm transmission path between parts of paths between the cabinets are supervised if the the VACIE contained in more than one cabinets used for one system are not mounted in cabinet even where the fault does not affect one room. a mandatory function; The installer has to ensure that the supervision of voice alarm transmission path to the the emergency CALL STATION microphone is emergency microphone capsule, if provided; activated. EN 54-16 | en 17 21-Sep-2015 | 01 | b) any short-circuit or interruption in the c) any short-circuit or interruption in the The installer has to ensure that the loudspeaker voice alarm transmission path between the lines are permanently supervised by one of the VACIE and loudspeakers even where the following options: fault does not affect the operation of – PLN-1EOL loudspeakers. – PVA-1WEOL – Permanent impedance measurement d) any short-circuit or interruption in the The installer has to ensure that the path to fire transmission path between the VACIE and alarm devices are supervised. fire alarm devices when used. Note: E.g. with supervised control inputs. e) failure of any power amplifier. The installer has to ensure that the supervision of Signature en | EN 54-16 Compliance 18 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 the amplifiers is activated. 8.3 Indication of faults related to the transmission path to the CIE (option with Installer checklist requirements) The VACIE may have provision for an The installer has to ensure that the path to the CIE indication of faults related to the is supervised. transmission path to the CIE. In this case, Note: E.g. with supervised control inputs. the shortcircuit or interruption of the transmission path to the CIE shall be indicated by means of a separate light emitting indicator and/or an alphanumeric display. 8.4 Indication of faults related to voice alarm zones (option with requirements) EN 54-16 Compliance The VACIE may have provision for an The PAVIRO system is able to indicate each indication of faults related to voice alarm loudspeaker zone failure at the emergency CALL zones. In this case the short-circuit or STATION display by indicating the zone number. The interruption of a voice alarm transmission installer has to ensure that each amplifier may only path between the VACIE and the be part of one voice alarm zone. Signature EN 54-16 Clause/Requirement EN 54-16:2008 loudspeakers in that zone shall be indicated by means of a separate light emitting indicator per zone and/or an alphanumeric display. 8.5 System fault A system fault is a fault as specified in 14.4 No signature necessary in or 14.6 in the case of software controlled this line. VACIE. A system fault may prevent Installer checklist requirements of this European Standard, other than those specified below, from being fulfilled. In the event of a system fault at least the following shall apply: a) a system fault shall be visibly indicated by The installer has to ensure that the DEL button on means of the general fault warning indicator the emergency CALL STATION needs to be and a separate light emitting indicator on configured as system fault reset. The yellow LED of the VACIE. These indications shall not be this button indicates a system fault. The button suppressed by any other functional needs to be clearly marked being related to system condition of the VACIE and shall remain until fault. Note: We recommend to label the system fault key: operation at access level 2 or 3; „System Fault“ b) a system fault shall be audibly indicated. The Installer has to enable the sounder of the This indication may be capable of being emergency CALL STATION. The sounder can be silenced. silenced by pressing the fault (ESC) button. Audible indication EN 54-16 | en 19 21-Sep-2015 | 01 | 8.6 a manual reset and/or another manual Signature The audible indication of faults required in The sounder in the emergency CALL STATION which No signature necessary in 8.2 shall be capable of being silenced is used for failure indication can be silenced by manually at access level 1 or 2 at the VACIE. pressing the fault (ESC) button. this line. The same manual operation may be used as en | EN 54-16 Compliance 20 21-Sep-2015 | 01 | 8.6.1 Clause/Requirement EN 54-16:2008 for silencing the voice alarm condition. 8.6.2 The audible indication shall be silenced If the PAVIRO system is reset from the fault warning No signature necessary in automatically if the VACIE is automatically condition, the sounder is automatically silenced. this line. If previously silenced, the audible indication The sounder used for audible indication starts No signature necessary in shall resound for each newly recognized sounding again every time a new failure occurs. this line. reset from the fault warning condition. 8.6.3 fault. Installer checklist 8.7 Reset of fault indications 8.7.1 Indications of faults as required in 8.2 shall No signature necessary in be capable of being reset this line. a) automatically when faults are no longer The indication of faults is reset automatically when No signature necessary in recognized, and/or faults are no longer recognized. this line. b) by a manual operation at access level 2. Reset of system fault can be carried out via dedicated configured CALL STATION button. 8.7.2 Following reset as specified in 8.7.1, the PAVIRO fault indication will remain or be re- No signature necessary in indication of the correct functional established within 20 s. this line. conditions corresponding to any received signals shall either remain or be reestablished within 20 s. 8.8 Transmission of the fault warning condition The VACIE shall have provision for There is a fixed defined potential free output transmitting, by means of at least general contact at the PAVIRO CONTROLLER (Ready Relais fault signal, all faults specified in 8. This on Control Output Connector) which gives a fault signal shall also be given if the VACIE is collective fault signal. This contact is also active when the system is de-energized EN 54-16 de-energized. 10 Voice alarm manual control (option with requirements) Clause/Requirement EN 54-16:2008 10.1 Compliance Signature The VACIE may have provision for manually Note: We recommend to label the voice alarm No signature necessary in activating the voice alarm output condition. manual control key: „Start Alarm“ this line. EN 54-16 3.6 General requirements If a voice alarm output control facility is provided the following shall apply: a) a manual control which causes a voice The Installer has to ensure to configure access level alarm output condition to be given shall only 2 for the manual control. be accessible at access level 2 and b) it shall be possible to activate each voice The Installer has to ensure to configure the system alarm zone individually and/or in group(s) of accordingly. voice alarm zones; Installer checklist c) the manual activation of a voice alarm PAVIRO will prevent mandatory indications. zone shall not prevent the mandatory No signature necessary in this line. indications and outputs to other voice alarm zones. 10.2 Indication of the voice alarm zones in an activated condition The indication for the voice alarm condition No signature necessary in in the voice alarm zone(s) associated with this line. each manual control shall be available without any manual action and shall not be suppressed. This indication shall be by means of The voice alarm condition is indicated on the General Voice Alarm Output activated PAVIRO system by a red indicator on the emergency indicator), and CALL STATIONs (the alarm LED). The installer has to ensure to configure the emergency CALL STATIONs accordingly. EN 54-16 | en 21 21-Sep-2015 | 01 | a) a separate light emitting indicator (the Compliance Signature 22 b) a separate light emitting indicator and/or A separate light emitting indicator is available for No signature necessary in alphanumeric display for each voice alarm each voice alarm zone and/or group(s) of voice this line. zone and/or an indication for group(s) of alarm zones. en | EN 54-16 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 voice alarm zones. NOTE These indicators may not necessarily No signature necessary in indicate which emergency message is being this line. broadcast in each voice alarm zone. 10.3 Indication of the voice alarm zones in fault condition The indication for the fault condition which No signature necessary in would prevent the generation and this line. transmission of the voice alarm signal to the voice alarm zone(s) associated with each Installer checklist manual control shall be available without any manual action and shall not be suppressed. This indication shall be by a) a separate light emitting indicator (the The fault condition is indicated on the PAVIRO general fault indicator), and system by a yellow indicator on all emergency CALL STATIONs (the fault LED). b) an indication for each voice alarm zone Individual faults for each voice alarm zone are and/or an indication for defined group(s) of indicated at the emergency CALL STATION display. zones. The installer has to ensure to configure the system accordingly. EN 54-16 11 Interface to external control device(s) (option with requirements) Clause/Requirement EN 54-16:2008 Compliance Signature The VACIE may have provision for interfacing to external Not supported No signature necessary in this control devices(s) such as standardized user interfaces EN 54-16 3.7 line. required by local regulations. a) the interface shall allow only access level 1 and 2 functions; b) the mandatory functions of the VACIE shall not be overridden; c) any short circuit, interruption or earth fault in the transmission path to the external device(s) shall: 1) not prevent the mandatory function of the VACIE and 2) be indicated on the VACIE, at least by means of the general fault warning indicator. Installer checklist NOTE The external control devices should comply with available local codes, European Standards or national standards. 3.8 12 Emergency microphone(s) (option with requirements) Clause/Requirement EN 54-16:2008 Compliance Signature The VACIE may have provision for emergency No signature necessary in this microphone(s). In this case the emergency line. microphone(s) shall have a) priority over all inputs, including pre-recorded An emergency microphone can be configured from 0 messages, (lowest priority) to 100 (highest priority). The installer has to ensure that the priority of the emergency microphone is higher than the priorities of other signals including pre-recorded messages. same priority operate on first come first serve basis. 23 21-Sep-2015 | 01 | resource or destination conflicts. Calls with the EN 54-16 | en Higher priorities overrule lower priorities in case of Compliance Signature microphone channel, at access level 2; 2 for the emergency microphone. c) where a pre-announcement attention drawing A emergency CALL STATION has an LC display No signature necessary in this signal is provided, an indicator adjacent to the which indicates an active pre-chime. If the pre- line. microphone shall show when the signal has chime signal has finished, the display shows finished and live speech can commence, and "announcement". en | EN 54-16 b) an emergency microphone control to open the The Installer has to ensure to configure access level 24 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 Note: Pre-announcement signal is mixed with live speech. d) when the emergency microphone control is The sounder of the CALL STATION will be switched operated, any audible indication that might off automatically when a call is made. The installer interfere with the use of the microphone shall be has to ensure to switch off any loudspeaker near Installer checklist automatically muted. the emergency microphone. e) where the VACIE has provision for the An emergency microphone can be configured from 0 connection of more than one emergency (lowest priority) to 100 (highest priority). Higher microphone, they shall be configurable for priorities overrule lower priorities in case of priority at access level 3 or 4 and only one resource or destination conflicts. Calls with the emergency microphone shall be active at any one same priority operate on first come first serve basis. time 3.9 13 Design requirements Clause/Requirement EN 54-16:2008 13.1 Compliance Signature General requirements and manufacturer’s declarations 13.1.1 The VACIE shall comply with the design No signature necessary requirements of this clause, where relevant to in this line. the technology used. Some requirements can be verified by testing. Others can only be verified by inspection of the design and its accompanying documentation because of the combinations of functions and of establishing the long-term reliability of the VACIE. EN 54-16 impracticability of testing all of the possible 13.1.2 Compliance Signature In order to assist the process of design No signature necessary inspection, the manufacturer shall declare the in this line. EN 54-16 Clause/Requirement EN 54-16:2008 following in writing: a) that the design has been carried out in The BOSCH development department responsible accordance with a quality management for development/maintenance of the PAVIRO system in this line. No signature necessary system which incorporates a set of rules for - part of the EVI Audio GmbH - works according to the design of all elements of the VACIE; ISO 9001. b) that the components of the VACIE have The components of the PAVIRO system operate No signature necessary been selected for the intended purpose and within their specification within the specified in this line. are expected to operate within their environmental conditions (Class 3k5 of EN specification when the environmental 60721-3-3:1995 + A2:1997). It is the responsibility conditions outside the cabinet of the VACIE of the installer that other parts of the system, e.g. comply with Class 3k5 of EN 60721-3-3:1995 + the 19”-racks, comply with this requirement. Installer checklist A2:1997. 13.2 Documentation 13.2.1 The manufacturer shall prepare installation The PAVIRO user manuals and the installer checklist No signature necessary and user documentation which shall be are provided. in this line. a) a general description of the equipment, The user manual of the PAVIRO CONTROLLER No signature necessary including a list of contains a general description of the PAVIRO in this line. submitted to the testing authority together with the VACIE. This shall comprise at least the following: 1) the optional functions with requirements of system. The installer checklist (this document) this European Standard, describes all functions related to EN 54-16. 2) the functions relating to other parts of EN 54, and 3) the ancillary functions not required by this 25 21-Sep-2015 | 01 | EN 54-16 | en European Standard; Compliance Signature 26 b) technical specifications of the inputs and The inputs and outputs for audio and control are No signature necessary outputs of the VACIE, sufficient to permit an described in the user manual including the technical in this line. assessment of the mechanical, electrical, and data, system functions, configuration instructions, en | EN 54-16 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 software compatibility with other components compliancy to standards. of the system (e.g. as described in EN 54-1), including where relevant 1) the power requirements for recommended operation, 2) the maximum number of voice alarm zones, 3) information concerning the connection of emergency microphones, 4) the maximum and minimum electrical ratings for each input and output, 5) information on the communication Installer checklist parameters employed on each transmission path, 6) recommended cable parameters for each transmission path, and 7) fuse ratings; c) specified means to limit the consequences The user manual describes all means to limit the No signature necessary of fault (see 13.5.2); consequences of fault. in this line. d) configuring and commissioning Configuration instruction are included in the user No signature necessary instructions; manual and IRIS-Net software help file, in this line. commissioning instructions are in this checklist. e) operating instructions; f) maintenance information. Operating instructions are included in the user No signature necessary manual in this line. Maintenance information of the PAVIRO system is No signature necessary included in the user manual. in this line. EN 54-16 Compliance Signature The manufacturer shall prepare design All of the mentioned design documentation is No signature necessary documentation that shall be submitted to the available as for inspection by testing authorities. in this line. EN 54-16 13.2.2 Clause/Requirement EN 54-16:2008 testing authority together with the VACIE. This documentation shall include drawings, parts lists, block diagrams, circuit diagrams and a functional description to such an extent that compliance with this European Standard may be checked and that a general assessment of the mechanical and electrical design is made possible. Installer checklist 13.3 Mechanical design requirements 13.3.1 The cabinet of the VACIE shall be of robust The emergency CALL STATION complies with this construction consistent with the method of requirement. The installer has to ensure for installation recommended in the implementing this requirement for 19”-units, by documentation. It shall meet at least means of using a correct 19”- frame, meeting at classification IP30 of EN least classification IP30 of EN 60529:1991+A1:2000. 60529:1991+A1:2000. 13.3.2 All interconnections and settings inside the The installer has to ensure to install the system in a cabinet shall be accessible at level 3. compliant rack with restricted access to the rear panels. 13.3.3 The VACIE may be housed in more than one The mandatory controls and indicators are located cabinet. If the documentation shows that the on the emergency CALL STATION. cabinets may be installed in locations distributed within the protected premises, then all of the mandatory manual controls and indicators shall be on one cabinet or on cabinets declared to be only suitable for 27 21-Sep-2015 | 01 | EN 54-16 | en mounting adjacent to each other. Signature All mandatory manual controls and light The emergency CALL STATION has paper slots emitting indicators shall be clearly labeled to below each of its programmable buttons. The indicate their purpose. The labels shall be installer has to ensure providing proper labels that legible at 0.8 m distance in an ambient light fit into these paper slots and implement this intensity from 100 lux to 500 lux. requirement. The terminations for transmission paths and All terminations for transmission paths are clearly No signature necessary the fuses shall be clearly labeled. labeled on all of the PAVIRO system elements (near in this line. en | EN 54-16 13.3.5 Compliance 28 21-Sep-2015 | 01 | 13.3.4 Clause/Requirement EN 54-16:2008 the relevant connectors). 13.4 Electrical and other design requirements 13.4.1 The processing of signals shall give the Signals within the PAVIRO system have a configured highest priority to the voice alarm condition. priority. The installer has to ensure to give the voice alarm signals the highest priority. Installer checklist 13.4.2 Transitions between the main and the standby Transition between the main and standby power No signature necessary power sources shall not change any in this line. sources does not change any of the indications indications and/or the state of any outputs, and/or state of any outputs of the PAVIRO system, except those relating to the power supplies. except for the fault warning indication in order to report the failure of a power source. 13.4.3 If the VACIE has provision for disconnecting or The installer has to ensure that these items are only No signature necessary adjusting the main or the standby power in this line. accessible at access level 3 or 4. source, this shall only be possible at access level 3 or 4. EN 54-16 Compliance 13.5 Integrity of transmission paths 13.5.1 A fault in any voice alarm transmission path The PAVIRO system has the following voice alarm between the VACIE and other components of transmission paths between itself and other parts of the voice alarm system shall not affect the the voice alarm system: correct functioning of the VACIE or of any – transmission path between CIE and PAVIRO – transmission path between FPA5000 and other voice alarm transmission path. Signature EN 54-16 Clause/Requirement EN 54-16:2008 system via input contact, PAVIRO via Ethernet, – transmission path between PAVIRO system and the loudspeaker(s), – transmission path between PAVIRO controller and emergency PAGING STATION. If there is a fault in the transmission path between the CIE and an input contact of the PAVIRO system, Installer checklist the configured action of the input contact will not be automatically activated or deactivated. The correct functioning of the PAVIRO system or of any other voice alarm transmission path is therefore not affected. The fault will be reported. If there is a fault in the transmission path between the PAVIRO system, i.e. the amplifier outputs and the loudspeaker(s), the loudspeaker(s) will not be able to produce the intended audio signal. However the fault will not affect the correct functioning of the PAVIRO system or any other voice alarm transmission path. The fault will be reported, only. 13.5.2 A short circuit or an interruption in the The installer has to make sure to install the system transmission path to the loudspeaker(s) shall accordingly. the fault. 29 21-Sep-2015 | 01 | longer than 100 s following the occurrence of EN 54-16 | en not affect more than one voice alarm zone for A single short circuit or an interruption in any We recommend to install the emergency CALL voice alarm transmission path between STATION inside of the cabinet. In case of distributed cabinets of a VACIE shall not interruption of the transmission path to the prevent the activation of a voice alarm output emergency CALL STATION the CONTROLLER will condition to more than one voice alarm zone activate the system fault condition. Signature en | EN 54-16 Compliance 30 21-Sep-2015 | 01 | 13.5.3 Clause/Requirement EN 54-16:2008 for longer than 100 s following the occurrence of the fault. 13.5.4 If the VACIE is designed to be used with a If a 19”-cabinet (rack) or adjacent cabinets provide power supply (item L of Figure 1 of EN 54-1) enough space for the battery and/or charger, the contained in a separate cabinet, then an installer can install the complete PSE (power supply interface shall be provided for at least two equipment) as referred in EN 54-4 in one cabinet. In voice alarm transmission paths to the power that case this requirement is not applicable. supply, such that a short circuit or an In case the installer installs the backup part of the interruption in one does not affect the other. PSE (battery and charger) in a separate cabinet, Installer checklist PAVIRO provides a separate DC-backup connection on the PAVIRO units (Amplifiers). This implies that a PAVIRO installation will always have two separate power paths to the power supply: one for mains and one for DC backup. Both will not influence each other. For parts that do have only 24V DC connectors (e.g. PAVIRO CONTROLLER), the PSE needs to be in the same rack. It is the responsibility of the installer to let the installation comply with this requirement. EN 54-16 13.6 Compliance Accessibility of indications and controls Four access levels shall be provided on the The Installer has to ensure to configure access VACIE, from access level 1 (most accessible) levels described below. to access level 4 (least accessible). Manual Access level 1 is intended for operational users of controls at a given access level shall not be the PAVIRO system. It provides direct operational accessible at a lower access level. The access to the unrestricted functionality of the following shall apply: PAVIRO system via: – Signature EN 54-16 Clause/Requirement EN 54-16:2008 Input contacts of system components that have level 1 functionality – The front panel menu of system components (LED indications, acknowledge button) – A non emergency CALL STATION Access level 2 is intended for advanced operational users of the PAVIRO system. It provides operational Installer checklist access to the system after gaining access to a physical part of the system. Access level 2 is enforced for the access level 1 access points by means of physical access control, which restricts access to persons that possess the physical access device (e.g. key, access card, et cetera). – Input contacts with physical access control; the system components offering the input contacts are located in a room/cabinet that is not generally accessible – A emergency CALL STATION with physical access control over the lock key. The key switch has to be connected so the key can be removed in locked position only. Use pin 1 and pin 2 of the key switch. A emergency CALL STATION with physical a room/cabinet that is not generally accessible 31 21-Sep-2015 | 01 | access control; the CALL STATION is located in EN 54-16 | en – Compliance configurators of the PAVIRO system. It provides access for hardware configuration and installation of the PAVIRO system after physical access to the en | EN 54-16 Access level 3 is intended for installers and/or Signature 32 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 rear of the rack – Physical access control by means of installing the system elements in a restricted environment, such as placing the 19”-units in a 19”-rack with key lock. This type of access can be used for physical diagnosis of the system, e.g. inspect interconnections. Access level 4 is intended for maintenance personnel of the PAVIRO system. It provides software configuration and firmware upgrade of the Installer checklist PAVIRO system components after logical identification. This level of access is offered through: – The IRIS-Net PC software. At access level 4, specialized configuration software is needed. a) all mandatory indications shall be visible at All mandatory indications are placed on the access level 1 without prior manual emergency CALL STATION. The installer has to intervention (e.g. the need to open a door); ensure to mount the emergency CALL STATION on a suitable place. If the CALL STATION is installed in a cabinet with a front door, the door must be a glass door. b) manual controls at access level 1 shall be The installer has to ensure to enable access level 1 accessible without special procedures; controls without special procedures. c) indications and manual controls that are All PAVIRO indications (LEDs, equipment connected mandatory at access level 1 shall also be to output contacts, front panel indication, LC accessible at access level 2; display) and manual controls (input contacts, CALL STATION buttons) that are accessible at access EN 54-16 level 1 are also be accessible at access level 2. Compliance d) entry to access level 2 shall be restricted The installer has to ensure to enable access level 2 by a special procedure; controls with special procedures. e) entry to access level 3 shall be restricted Entry to access level 3 is restricted by limiting by a special procedure, differing from that for access to the rear of the rack. Correct configuration access level 2; and installation (physical access control) will ensure Signature EN 54-16 Clause/Requirement EN 54-16:2008 that the special procedure differs from that of access level 2. The system administrator should define different users in IRIS-Net. The installer should ensure that the physical access procedure differs from that of the physical access procedure of access level 2. f) the entry to access level 4 shall be The IRIS-Net PC software. At access level 4, a restricted by special means which are not part password is needed. Installer checklist of the VACIE. NOTE Further access levels are permitted provided that they are distinct from the access levels described in this standard. 13.7 Indications by means of light-emitting indicators 13.7.1 Mandatory indications from light emitting The emergency CALL STATION fulfills the indicators shall be visible in an ambient light requirements. intensity up to 500 lux, at any angle up to The installer has to ensure to put the emergency 22.5° from a line through the indicator CALL STATION on a place where the requirements perpendicular to its mounting surface are met also. E.g. installation behind a class door. – at 3 m distance for the general No dark glass. Avoid installation on top or bottom of indications of functional condition, the rack. – at 3 m distance for the indication of the at 0.8 m distance for other indications. 33 21-Sep-2015 | 01 | – EN 54-16 | en supply of power, and Compliance Signature 34 If flashing indications are used, both the on The emergency CALL STATION fulfils the No signature necessary en | EN 54-16 21-Sep-2015 | 01 | 13.7.2 Clause/Requirement EN 54-16:2008 period and the off period shall be greater than requirements in this line. or equal to 0.25 s, and the frequencies of flash shall not be less than – 1 Hz for voice alarm indications, and – 0.2 Hz for fault indications. 13.8 Indications on alphanumeric displays 13.8.1 If an alphanumeric display consists of The LCD of the emergency CALL STATION does not No signature necessary elements or segments, the failure of one of consists of elements or segments. in this line. these shall not affect the interpretation of the displayed information. 13.8.2 Installer checklist 13.8.3 If an alphanumeric display is used to display The display of the emergency CALL STATION is used No signature necessary mandatory indications, it shall be clear and for indicating the different statuses. Therefore each unambiguous. displayed information has a separate term. Mandatory indications on an alphanumeric The emergency CALL STATION fulfills the display shall be legible for at least one hour requirements and the indication stays on as long as following the display of a new indication of the system is in the corresponding condition. the voice alarm condition and at least 5 The installer has to ensure to put the emergency in this line. minutes for fault or disablement conditions, at CALL STATION on a place there the requirements 0,8 m distance, in ambient light intensities are met also. E.g. installation behind a glass door. from 5 to 500 lux, at any angle from the No dark glass. Avoid installation on top or bottom of normal to the plane of the display up to the rack. – 22.5º when viewed from each side, and – 15º when viewed from above and below. 13.9 Indication colors 13.9.1 The colors of the general and specific No signature necessary indications from light emitting indicators shall in this line. be a) red for indications of voice alarms; No signature necessary on (red) when the system is in the voice alarm in this line. condition. EN 54-16 The alarm LED of the emergency CALL STATIONs is Compliance Signature b) yellow for indications of fault warnings The Fault LED of the emergency CALL STATIONs is No signature necessary on (yellow) when the system is in the fault warning in this line. EN 54-16 Clause/Requirement EN 54-16:2008 condition. c) green for the indication that the VACIE is All light emitting indicators of the PAVIRO system No signature necessary supplied with power. that indicate power supply are green. in this line. NOTE Where voice alarm automatic message No signature necessary status indicators are provided, it may be in this line. advantageous to indicate the difference between evacuation and alert messages. In this case, red will be used for emergency messages and yellow may be used for alert messages. 13.9.2 Installer checklist The use of different colors is not necessary for The LCD used in the emergency CALL STATION No signature necessary indications on alphanumeric displays. does not use different colors for indications. in this line. However, if different colors are used for different indications, the colors used shall be as specified in 13.9.1. 13.10 Audible indications 13.10.1 Audible indicators shall be part of the VACIE. The sounder in the emergency CALL STATION will No signature necessary The same device may be used for voice alarm be used for both indications. in this line. zone activated and fault warning indications. 13.10.2 The emergency CALL STATION fulfills the under anechoic conditions at a distance of 1 requirements. m, with any access door(s) on the VACIE The installer has to ensure to put the emergency closed, shall be CALL STATION on a place where the requirements – 60 dBA for the voice alarm condition, and are met also. E.g. installation behind a glass door. – 50 dBA for the fault warning condition. Indicator testing EN 54-16 | en 35 21-Sep-2015 | 01 | 13.11 The minimum sound pressure level, measured Compliance Signature 36 All mandatory visible and audible indicators PAVIRO provides an LED test via the menu on the No signature necessary shall be testable by a manual operation at emergency CALL STATION at access level 1. This in this line. access level 1 or 2. indicator test is a local test. en | EN 54-16 21-Sep-2015 | 01 | Clause/Requirement EN 54-16:2008 When activated all indications on that emergency CALL STATION and all its connected emergency CALL STATION EXTENSIONS are switched on to visually and audible check the indicators. 13.12 Audio performance 13.12.1 Output power The output power of the amplifier elements of the No signature necessary The VACIE output power shall be as declared PAVIRO system are specified in the data sheets and in this line. by the manufacturer. user manuals. Signal-to-noise ratio The A-weighted signal-to-noise ratio of the PAVIRO No signature necessary The VACIE shall have an A-weighted signal-to- amplifiers is specified in the data sheets and in the in this line. noise ratio of at least 45 dB (see IEC manuals. The signal-to-noise ratio is above 100 dB. 60268-1). The complete signal chain from microphone to 13.12.2 Installer checklist loudspeaker is compliant to this clause. 13.12.3 Frequency response The default settings of the audio filters in IRIS-Net The frequency response of the VACIE shall fit ensure the correct frequency response of all sound within the nonshaded area in Figure 1 for paths. If the default settings are edited in IRIS-Net, sound sources without microphone(s) (e.g. the installer has to ensure that the frequency message store) and Figure 2 for sound response still fits within the non-shaded area in sources with microphone(s). Figure 1 and 2. NOTE The frequency response limits exclude loudspeakers. NOTE A bandwidth of 400 Hz to 4 kHz is sufficient to achieve acceptable intelligibility in some acoustic environments. However, a higher frequency limit may be necessary to achieve acceptable intelligibility in more difficult acoustic environments due, for reverberation and/or ambient noise. EN 54-16 example, to the masking effect caused by 13.13 Compliance Signature Message store(s) EN 54-16 Clause/Requirement EN 54-16:2008 Pre-recorded messages shall be stored in non- The pre-recorded messages are digitally stored on a volatile memory that retains the messages EEPROM/Flash in uncompressed format (PCM, 16- when all power sources are removed. bit). This EEPROM/Flash retains the messages when NOTE The use of tapes or magnetic or optical all power sources are removed. data disks for the storage of emergency messages is not acceptable at the time of drafting this European Standard (see Annex C) 13.14 Redundant power amplifiers 13.14.1 The VACIE may have provision for at least one No signature necessary spare power amplifier. In this case: in this line. Installer checklist a) in the event of the failure of a power The installer has to ensure to configure spare amplifier, the faulty amplifier shall be capable amplifier switching accordingly. of being replaced automatically with a spare amplifier withing 10 s of the fault being detected; NOTE: This can be achieved, for example, by switching or by permanently connected parallel amplifiers. b) the spare power amplifier(s) shall have at The installer has to ensure to include a spare least the same functionality and output power amplifier with at least the same output power. as the replaced amplifier. 13.14.2 Every fault of an amplifier shall be indicated The installer has to ensure to enable supervision on by the general fault warning indicator as the spare amplifier. specified in 8.2 Supervision on spare amplifiers works with both No signature necessary maintained during the functional condition conditions. in this line. whilst the VACIE is powered by either the mains or standby power supplies. 37 21-Sep-2015 | 01 | Supervision of the spare amplifier(s) shall be EN 54-16 | en 13.14.3 38 14 Additional design requirements for software controlled VACIE Clause/Requirement EN 54-16:2008 14.1 Compliance Signature In order to fulfill requirements of this The PAVIRO system is controlled by compliant No signature necessary European Standard the VACIE may contain software. in this line. en | EN 54-16 21-Sep-2015 | 01 | 3.10 General requirements and manufacturer’s declarations elements which are controlled by software. In this case, the VACIE shall comply with the requirements of Clause 13 and this clause where relevant to the technology used. Installer checklist 14.2 Software documentation EN 54-16 Compliance Signature The manufacturer shall prepare Design and development documents have been No signature necessary documentation that gives an overview of the provided and approved by certification authority. in this line. EN 54-16 14.2.1 Clause/Requirement EN 54-16:2008 software design, which shall be submitted to the testing authority together with the VACIE. This documentation shall be in sufficient detail for the design to be inspected for compliance with this European Standard and shall comprise at least the following: a) functional description, using a clear methodology appropriate to the nature of the software, e.g. graphical representations of the system design, data flows and control flows and of the main program flow, including: 1) a brief description of each module and the Installer checklist tasks it performs, 2) the way in which the modules interact, 3) the way in which the modules are called, including any interrupt processing, and 4) the overall hierarchy of the program; b) a description of which areas of memory are used for the various purposes (e.g. the program, site specific data and running data); c) a description of how the software interacts with the hardware of the VACIE. Where dynamic memory management is employed, a separation shall be implemented between the program, site specific data and running data and this shall be described in connection with the method of memory 39 21-Sep-2015 | 01 | EN 54-16 | en allocation. Compliance Signature 40 The manufacturer shall prepare and maintain Documents have been inspected and approved by No signature necessary detailed design documentation. This need not certification authority. in this line. en | EN 54-16 21-Sep-2015 | 01 | 14.2.2 Clause/Requirement EN 54-16:2008 In order to ensure the reliability of the VACIE PAVIRO is built on a modular structure. No signature necessary the following requirements for software Not relevant, there is no manually or automatically in this line. design shall apply: generated data. a) the software shall have a modular PAVIRO is equipped with a watchdog which will structure; signalize a deadlock and automatically carry out a b) the design of the interfaces for manually reset. be submitted to the testing authority but shall be available for inspection in a manner which respects the manufacturer's rights of confidentiality. This documentation shall comprise at least the following: a) a description of each module of the program, as it is implemented in the source code of the program, containing: 1) the name of the module, and 2) the identification of the author(s); b) the source code listing, including all global Installer checklist and local variables, constants and labels used, and sufficient comment for the program flow to be recognized; c) details of any software tools used in the preparation of the program (e.g. high level design tools, compilers, assemblers). 14.3 Software design and automatically generated data shall not permit invalid data to cause an error in the program execution; c) the software shall be designed to avoid the 14.4 Program monitoring (see also Annex C) EN 54-16 occurrence of a deadlock in the program flow. Compliance Signature The execution of the program shall be Upon activation of a watchdog, a fault is reported No signature necessary monitored as under 14.4.2 or 14.4.3. If after restart of the failing component. A system fault in this line. EN 54-16 14.4.1 Clause/Requirement EN 54-16:2008 routines associated with the main functions of is indicated when entering the fault condition. the program are no longer executed, either or Upon activation of a watchdog, a fault is reported both of the following shall apply: after restart of the failing component indicating the a) the VACIE shall indicate a system fault (as failing component. in 8.3); b) the VACIE shall enter the fault warning condition and indicate faults of affected supervised functions (as in 8.2.3, 8.2.4, 8.3, 8.4 and 8.5), where only these functions are affected. 14.4.2 If the program executes in one processor, the All processors used in the PAVIRO system are either No signature necessary execution of the routines in 14.4.1, it shall be guarded by a hardware watchdog or are monitored in this line. Installer checklist monitored by a monitoring device as in 14.4.4. by a processor that is guarded by a hardware watchdog. 14.4.3 If the program executes in more than one The network controller is responsible for monitoring No signature necessary processor, the execution of the routines in all processors in the system. Upon failure of one of in this line. 14.4.1 shall be monitored in each processor. A the processors, either due to a watchdog failure or monitoring device as in 14.4.4 shall be due to a communication failure a fault is generated. associated with one or more processors, and Failure of the network controller itself will cause the at least one such processor shall monitor the system fault output contact to be de-activated to functioning of any processor not associated indicate a system fault. with such a monitoring device. 14.4.4 The monitoring device of 14.4.2 and 14.4.3 All components that have a processor have an No signature necessary shall have a time-base independent of that of external watchdog. in this line. the monitored system. The functioning of the monitoring device, and the signaling of a fault monitored system. 41 21-Sep-2015 | 01 | the execution of the program of the EN 54-16 | en warning, shall not be prevented by a failure in Compliance Signature 42 In the event of a system fault as specified in Safe state is included at all components. No signature necessary en | EN 54-16 21-Sep-2015 | 01 | 14.4.5 Clause/Requirement EN 54-16:2008 14.4.1 a) or 14.6, those parts of the VACIE in this line. affected shall enter a safe state not later than the indication of the system fault. This safe state shall not result in the false activation of mandatory outputs. 14.5 The storage of programs and data (see also Annex C) 14.5.1 All executable code and data necessary to According to the datasheet of the memory more No signature necessary comply with this European Standard shall be than 10 years. in this line. held in memory that is capable of continuous, unmaintained, reliable operation for a period of at least 10 years. Installer checklist 14.5.2 For the program, the following requirements No signature necessary shall apply: in this line. a) the program shall be held in non-volatile The program is stored in a non-volatile memory. No signature necessary memory, which can only be written to at Configuring requires access level 4. in this line. Version reference can be read out at access level 3. No signature necessary access level 4, and b) it shall be possible to identify the version reference or references of the program at in this line. access level 3. The version reference or references shall be in accordance with the documentation of 14.2.1. 14.5.3 For site-specific data, including emergency No signature necessary message(s), the following requirements shall in this line. apply: a) the alteration of site specific data shall only Responsibility of the installer to maintain site data. be possible at access level 3 or 4; The configuration is a data set that cannot alter the No signature necessary affect the structure of the program; program itself in this line. EN 54-16 b) the alteration of site specific data shall not Compliance Signature c) if stored in read-write memory, there shall There is an EEPROM/Flash which holds No signature necessary be a mechanism which prevents the memory configuration and program data. This is copied to in this line. being written to during normal operation at RAM, this RAM is used during operation. The access level 1 or 2, such that its contents are EEPROM/Flash is supervised. EN 54-16 Clause/Requirement EN 54-16:2008 protected during a failure in program execution; d) It shall be possible to either read or With specialized software at access level 3 the No signature necessary interrogate the site specific data at access configuration can be read out. in this line. No version reference. No signature necessary level 2 or 3, or the site specific data shall be given a version reference that shall be updated when each set of alterations is carried out. e) If the site specific data has a version Installer checklist reference, it shall be possible to identify this in this line. at access level 2 or 3. 14.6 Monitoring of memory contents The contents of the memories containing the There is a checksum on this data which is checked No signature necessary site specific data shall be automatically every 1 hour. in this line. checked at intervals not exceeding 1 h. The checking device shall signal a system fault if a corruption of the memory contents is detected. EN 54-16 | en 43 21-Sep-2015 | 01 | 44 15 Marketing Clause/Requirement EN 54-16:2008 Compliance Signature The VACIE shall be marked with the No signature necessary in this following information, line. en | EN 54-16 21-Sep-2015 | 01 | 3.11 which shall be legible at access level 1: a) the number of this European Standard; Marking the PAVIRO system with the number of this European standard (which is legible at access level 1) is the responsibility of the installer, since the installer will have to install and configure the system properly in order to let the installation comply with this standard. b) the name or trademark of the The name „BOSCH “ is visible on each unit of the PAVIRO manufacturer or supplier; system. It is the responsibility of the installer to ensure that this name is legible at access level 1 for all system Installer checklist elements. c) the type number or other designation of The type number of each unit of the PAVIRO system is the VACIE. present on the unit itself. The installer is responsible for ensuring that this type number is legible at access level 1. It shall be possible to identify a code or The serial numbers of each unit gives information about number that identifies the production the production period. This serial number is visible on period of the VACIE at access level 1 or 2 or the type number plate of each unit of the PAVIRO system. 3. The installer is responsible for ensuring that this type number plate is identifiable at access level 1, 2 or 3. NOTE Where Annex ZA.3 covers the same No signature necessary in this requirements as this clause, the line. requirements of this clause are met. 3.12 16 Tests All applicable tests are carried out in an accredited test lab. EN 54-16 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven The Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2015