Directional Control Valves Series D3W Catalog HY14-2502/US Technical Information General Description The D3W Series directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled 3 or 4-way valves. They are available in 2 or 3-position and conform to NFPA’s D05/CETOP 5 mounting patterns. B AB A PT Features • • • • • Worldwide, high flow, low pressure drop design. • • • • • • • Three electrical connection options. Mechanically tunable soft shift. 22 spools available including proportional. Repairable manual override for easy seal replacement. DC surge suppression available to protect electrical equipment. AC & DC lights available. Easy access mounting bolts. Specifications Explosion proof availability. CSA approved. Interface NFPA D05, CETOP 5, NG 10 No tools required for coil removal. Max. Operating Pressure P, A, B: 345 Bar (5000 PSI) Standard Rectified coils available for high flow AC applications. CSA 207 Bar (3000 PSI) Tank: 103 Bar (1500 PSI) Standard Response Time (ms) Signal to 95% spool stroke measured at 172 Bar (2500 PSI) and 75 LPM (20 GPM) CSA Solenoid Type Pull-In Drop-Out AC DC 21 110 35 85 CSA File Number 103 Bar (1500 PSI) LR060407 2502-A2.p65, dd A51 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA A Directional Control Valves Series D3W Catalog HY14-2502/US Ordering Information A D 3 W Directional Control Valve Basic Valve Actuator Spool Style Solenoid Voltage Seal Code E# Y T K J D# Z# NFPA D05 CETOP 5 NG 10 Wet armature solenoid Description 24/60 - 24/50 VAC 120/60 - 110/50 VAC 240/60 - 220/50 VAC 12 VDC 24 VDC 120 VDC 250 VDC # High Watt Coil only. Code Symbol A B 1 Symbol A B 14 P T P T A B A B P T A B P A T B P T P T A B A B 2 Code N V E 15 3 16 4 Description Nitrile Fluorocarbon EPR * Contact HVD for availability. 20* P T P T A B A B P T P T A B A B P T P T A B A B P T A B 5 21† 6 Code B* 22† 7 8*, 9** Code T B P T P T A B A B P T A B P T Symbol b b C 26*† P A Description Single solenoid, 2 position, spring offset P to A and B to T in offset position Double solenoid, 3 position, spring centered. b P T A B 11 P T A B P T 81† †† 82† †† Valve schematic symbols are per NFPA/ANSI standards, providing flow P to A when energizing solenoid A. Note operators reverse sides for #8 and #9 spools. See installation information for details. P T A B P T P T a a Double solenoid, 2 position, detent b A E Single solenoid, 2 position, spring centered. P to B and A to T when energized. P T b A B F Single solenoid, 2 position. Spring offset, energized to center. Position spool spacer on A side. P to A and B to T in spring offset position. P T H* Single solenoid, 2 position, spring offset. P to B and A to T in offset position. K Single solenoid, 2 position. Spring centered. A side. P to A and B to T when energized. P T A B M Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on B side. P to B and A to T in spring offset position. P T 12 * 8, 20 & 26 spools have closed crossover. ** 9 & 30 spools have open crossover. † Available only with high-watt rectified AC coils or high-watt DC coils. †† Spring centered versions C, E, F, K & M only. B B D† 30** 10† A A * Only spools 20, 26 & 30. † Only spools 20 & 30. A B P T A B B a a a This condition varies with spool code. 2502-A2.p65, dd A52 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D3W Catalog HY14-2502/US Ordering Information Connector Package Code C K P W S*†# E Solenoid Tube Options Options Manual Override Options Electrical Options Description Conduit Cavity Conduit Adaptor Hirschmann w/Plug Hirschmann w/o Plug Double Spade Explosion Proof Code Omit 4* K# Coil High Watt Explosion Proof, EExd Low Watt Explosion Proof, UL/CSA * Available only with J, K, Y (Rectified) and T (Rectified) voltages. † Explosion proof coils are 60 Hz at standard voltage; dual rating not available. Variations Design Series NOTE: Not required when ordering. Description Standard Valve CSA Approval UL Recognition * Not available with high pressure tube option. # Contact HVD for availability. * Available only with J, K, Y (Rectified) and T (Rectified) voltages. † Not CSA approved. # DC voltage only. Code Omit D† F* U† Approvals Shift Response and Indication Code Omit S3 S4 S7 I7 Description Standard Valve Soft Shift, 0.030" Orifice Soft Shift, 0.040" Orifice Soft Shift, 0.070" Orifice Monitor Switch* * Single solenoid models only. Not CE or CSA approved. Code Omit V# Z Description No Option Varistor Surge Suppressor AC Rectified with MOV Surge Suppressor # DC voltage only. Code Omit H Description Low Pressure High Pressure Code Omit P R Description Standard Tube Extended Manual Override Repairable Manual Override Code Omit 5 6 7 56 57 1A 1B 1C 1D Mounting Bolt Kits UNC Bolt Kits for use with D3W Directional Control Valves & Manapak/Cartpak Number of Manapaks/Cartpaks @ 2.00" (50mm) thickness 0 1 2 D3W BK98 BK141 BK142 1.62" 3.50" 5.50" D3W with BK144 BK61 BK62 explosion proof 2.37" 4.25" 6.25" coils Description Standard Valve Signal Lights Manaplug, Brad Harrison Mini Manaplug, Brad Harrison Micro (M12x1) Manaplug (Mini) with Lights Manaplug (Micro) with Lights (M12x1) Manaplug (Mini) Single Sol. 5-Pin Manaplug (Micro) Single Sol. 5-Pin (M12x1) Manaplug (Mini) Single Sol. 5-Pin w/Lights Manaplug (Micro) Single Sol. 5-Pin w/Lights (M12x1) Valve Weight: Single Solenoid: AC DC Double Solenoid: AC DC Standard Bolt Kit: Metric Bolt Kit: 3 BK143 7.50" BK63 8.25" 4.3 kg (9.5 lbs.) 5.3 kg (11.6 lbs.) 5.0 kg (11.0 lbs.) 7.3 kg (16.0 lbs.) BK98 BKM98 NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to 16 Nm (12 ft-lbs) 2502-A2.p65, dd A53 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA A Directional Control Valves Series D3W Catalog HY14-2502/US Technical Information Solenoid Ratings** A Insulation Allowable Deviation from rated voltage Armature Class H DC, AC Rect AC Wet pin type D3W*****F Solenoid Electrical Characteristics‡ -10% to +15% -5% to +5% ** DC Solenoids available with optional molded metal oxide varistor (MOV) for surge suppression. Leadwire length 6” from coil face. Nominal Volts/Hz In Rush VA Y 120/60 110/50 298 294 95 102 32 T 240/60 220/50 288 288 96 101 32 E 24/60 24/50 290 381 77 110 32 K 12 VDC — 3.00† 36 J 24 VDC — 1.50† 36 D 120 VDC — 0.30† 36 Nominal Volts/Hz In Rush Amps Holding Amps Watts KF 12 VDC — 3.00 18 JF 24 VDC — 0.75 18 ‡ Based on nominal voltage @ 22°C (72°F) D3W Solenoid Electrical Characteristics† Solenoid Code Solenoid Code D3W Rectified AC Solenoid Electrical Characteristics‡ Holding Nominal VA Watts (Ref) Solenoid Code Nominal Volts/Hz In Rush Amps Holding Amps Watts Y 120/60 110/50 — .37 36 T 240/60 220/50 — .18 36 YF 120/60 110/50 — .18 18 TF 240/60 220/50 — .09 18 ‡ Based on nominal voltage @ 22°C (72°F) † DC holding amps. Explosion Proof Solenoids Explosion Proof Solenoid Ratings U.L. (EU) C.S.A. ATEX Electrical Characteristics* ED and EU† Class I, Div. 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G As defined by the N.E.C Complies with ATEX requirements for: Exd, Group IIB; EN50014: 1999+ Amds 1 & 2, EN50018: 200 Solenoid Code Nominal Volts/Hz In Rush VA Holding Nominal VA Watts (Ref) Y 120/60 266 82 36 T 240/60 266 82 36 K 12 VDC — 3.00† 36 J 24 VDC — 1.50† 36 D 120 VDC — 0.30† 36 * Dual frequency not available on explosion proof coils. † DC holding amps. 2502-A2.p65, dd A54 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D3W Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Hirschmann, Double AC Solenoid A 107.7 (4.24) 90.0 (3.54) 89.8 (3.54) 86.2 (3.40) 69.5 (2.74) 36.0 (1.42) 21.5 (.85) 12.0 (.47) 74.5 (2.93) 23.0 (.91) 97.8 (3.85) 58.0 (2.29) 27.3 (1.08) 76.2 (3.00) 129.1 (5.09) 152.5 (6.01) Hirschmann, Single AC Solenoid 107.7 (4.24) 90.0 (3.54) 89.8 (3.54) 86.2 (3.40) 69.5 (2.74) See Note 36.0 (1.42) 21.5 (.85) 12.0 (.47) 74.5 (2.93) 23.0 (.91) 97.8 (3.85) 58.0 (2.29) 27.3 (1.08) 76.2 (3.00) 87.9 (3.45) Note: 30.0mm (1.18") from bottom of bolt counterbore. 2502-A2.p65, dd A55 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D3W Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) A Conduit Cavity, Double DC Solenoid 90.0 (3.54) 86.2 (3.40) 69.5 (2.74) 36.0 (1.42) 12.0 (.47) 21.5 (.85) 23.0 (.91) 122.5 (4.83) 58.0 (2.29) 27.3 (1.08) 76.2 (3.00) 177.2 (6.98) Conduit Cavity, Single DC Solenoid 90.0 (3.54) 86.2 (3.40) 69.5 (2.74) 36.0 (1.42) 12.0 (.47) 21.5 (.85) 23.0 (.91) 58.0 (2.29) 122.5 (4.83) 27.3 (1.08) 76.2 (3.00) 87.9 (3.46) 2502-A2.p65, dd A56 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D3W Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit Box Extension, Double AC Solenoid A with Variation 6 (Manaplug) & Variation P (Extended Manual Override) 15.9 (.63) 128.6 (5.07) 103.1 (4.06) 69.5 (2.74) 36.0 (1.42) 12.0 (.47) 21.5 (.85) 97.8 (3.85) 112.2 (4.42) 23.0 (.91) 58.0 (2.29) 27.3 (1.08) 74.1 (2.92) 76.2 (3.00) 152.5 (6.01) 166.9 (6.58) Conduit Box Extension, Double DC Solenoid with Variation 6 (Manaplug) & Variation P (Extended Manual Override) 15.9 (.63) 128.6 (5.07) 103.1 (4.06) 69.5 (2.74) 36.0 (1.42) 12.0 (.47) 21.5 (.85) 23.0 (.91) 140.4 (5.53) 58.0 (2.29) 27.3 (1.08) 76.2 (3.00) 195.0 (7.68) 2502-A2.p65, dd A57 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D3W Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) A Explosion Proof U.L. & CSA, Double Solenoid #18 AWG, 18 Inches Long, No Terminals, with UL Approval and Markings 1/2 Inch NPT Bolthole Centerline Reference 36.0 (1.42) 98.0 (3.86) 18.9 (0.74) 11.7 (0.46) 18.9 (0.74) Ref. 23.0 (0.91) 58.0 (2.29) Bolthole Centerline 12.0 Reference (0.47) 23.0 (0.91) 63.6 (2.51) 143.7 (5.66) 11.3 (0.44) 64.9 (2.56) Adapter Plate Included with Valve 76.9 (3.03) 117.2 (4.62) 197.3 (7.77) Explosion Proof ATEX, Double Solenoid M20 x 1.5-6H Metric Thread Bolthole Centerline Reference 134.7 (5.31) 103.6 (4.08) 36.0 (1.42) 18.9 (0.74) 11.6 (0.46) 18.9 (0.74) Ref. 23.0 (0.91) 58.1 (2.29) 12.1 (0.47) Bolthole Centerline Reference 154.1 (6.07) 23.0 (0.91) 75.6 (2.98) 11.3 (0.44) 64.9 (2.56) 76.7 (3.02) 207.7 (8.18) 2502-A2.p65, dd A58 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D3W Catalog HY14-2502/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit Box, Single DC Solenoid A with Variation I7 (Monitor Switch) 90.0 (3.54) 86.2 (3.40) 85.3 (3.36) 69.5 (2.74) 36.0 (1.42) 12.0 (.47) 21.5 (.85) 23.0 (.91) 58.0 (2.29) 27.3 (1.08) 76.2 (3.00) 122.5 (4.83) 176.2 (6.94) Monitor Switch (valve variation I7) Block Diagram This feature provides for electrical confirmation of the spool shift. This can be used in safety circuits, to assure proper sequencing, etc. Pin 1 (Input 24VDC) Inductor Pin 2 (Output – Normally Open) Regulator Switch Data Pin 3 (Output – Normally Closed) Inductive switch requiring +18-42 volt input. Outputs A and B are opposite; one at “0” voltage, the other at input voltage. During switching, A and B outputs reverse. Provides 0.4A switching current. Pin 4 (Ground Terminal) (Extended, or Energized Position) For repetitive switch power-up conditions, please consult factory. 2502-A2.p65, dd A59 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA Directional Control Valves Series D3W Catalog HY14-2502/US Accessories Conduit Box A (connection option K) Interface – 152.4 cm (6.0 inch) lead wires, 18 awg. – NEMA 4 rating available (consult factory) – Waterproof Manaplug (valve variations 6, 56, 1A, 1C) Interface – Brad Harrison Plug – 3-Pin for Single Solenoid – 5-Pin for Double Solenoid "B” Solenoid (Positive) Wire #1 (Red/White) Ground Wire #1 (Green) Solenoid (Negative) Wire #3 (Red/Black) "B” Solenoid (Negative) Wire #5 (Red/Black) "A” Solenoid (Positive) Wire #4 (Red/Yellow) "A” Solenoid (Negative) Wire #2 (Red) Solenoid (Positive) Wire #2 (Red/White) 3-Pin Manaplug (Mini) with Lights Ground Wire #3 (Green) 5-Pin Manaplug (Mini) with Lights Single Solenoid Valves Single and Double Solenoid Valves ("A" and "B" Solenoids Reversed for #8 and #9 Spools) Hirschmann Plug with Lights Manplug - Micro Connector (valve variations 7, 57, 1B, 1D) Pin #3 (Ground) Solenoid (Negative) Wire /3 (Blue) Solenoid (Positive) Wire /4 (Black) Pin #1 (Positive) Pin #2 (Negative) Ground Wire /1 (Brown) "B" Solenoid (Negative) Wire /1 (Brown) "B" Solenoid (Positive) Wire /2 (White) Ground Wire /5 (Gray) Face View of Plug "A" Solenoid (Positive) Wire /4 (Black) Conforms to DIN43650, ISO4400, Form A 3-Pin "A" Solenoid (Negative) Wire /3 (Blue) 2502-A2.p65, dd A60 Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio, USA
Documentos relacionados
Industrial Hydraulic Valves Catalog HY14-2502/US
** 009 & 030 spool have open crossover. See Universal Spool Chart for other spool options. 2502-A1.p65, dd
Leia mais