Crowcon - Portateis
Transcrição
Crowcon - Portateis
H2S CI2 CO O2 Eikon H2S CI2 CO O2 Single Gas Recyclable Monitor Toxic and oxygen gases H2S CI2 CO O2 Eikon With two years of maintenance free continuous monitoring in a rugged and robust over mould case, Eikon is fit for purpose in harsh environments. The simplest recyclable on the market with outstanding audible and visual alarms, it provides effective warning of hazardous conditions without the need for training or user interpretation. Reliable Rugged t 2 years guaranteed maintenance-free life t End of life indication t Confidence ‘Tap Tap’ test assures correct operation t Easy and unobtrusive to wear t Patented pocket clip makes sure the unit stays put t Dust and water tight to IP65 Simple Alarms t Highly audible 94dB alarm t Bright, multi-angled LEDs for maximum visibility t Distinctively different alarm tone and self check tone t No parts or servicing needed t No accidental switch off, unit is always on t No training required Eikon Eikon is a range of tough, reliable single gas recyclable monitors designed to withstand the harshest environments with 2 years continuous maintenance-free use. Typical ranges and alarms Specification: Eikon Weight 125g (4.4oz) Dimensions (H x W x D) 69 x 63 x 38mm 2.7 x 2.5 x 1.5 inches Audible Alarms 94dB @ 30cm Visible Alarms 4 multi-angled red LED Gas Range Standard Alarm (UK) Typical Response Time 5 seconds H2S 0-50ppm 5ppm Operating Life Continuously for 2 years. Pull strip to activate. CO 0-500ppm 30ppm O2 0-25% VOL 19% VOL Self Test/ Confidence Indicator NH3 0-50ppm 25ppm CI2 0-5ppm 0.5ppm Green LED flashes every 15 seconds. A double tap ("Tap/Tap") on a hard surface initiates a self test. An LED sequence and multi-tone bleep is performed upon successful completion. If red LED flashes rapidly the instrument is faulty. In the last week of life, a slow red LED flashes as well as the green confidence LED. End of Life End of life is indicated by 'n' red LED flashes to indicate 'n' number of weeks of life left Temperature Range -20OC to +50OC (-4OF to +122OF) Ingress Protection IP65 Humidity 5-95% RH non-condensing Approval Codes Europe ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +50°C) BASEEFA09ATEX0247 IECEx BAS 09.0114 Class 1, Div 1 Groups A,B, C, D Eikon is also available in a dual CO/H2S version Eikon Accessory This “one touch” bump test solution offers the ability to check Eikon’s status, change alarm level settings, bump and calibrate. Ideal for point of issue use, Eikon accessory is simple and quick to use. Status report commands, like calibration and zeroing, are transmitted with swipe cards for ease of use without a PC. These reports can be printed so the identity of Eikon can be detailed and allows a traceable audit trial. International N. America Safety Standards Europe & International N. America EN50014, EN50022, prEn50271 UL 913 & CSA 22.2 EMC Compliance EN50270 Accessories Eikon accessory bump test console, commander, swipe cards for commander, mini-printer, printer paper roll, module storage units Product Ordering Information UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected] Part Number Description C01780 Eikon H2S, 0-50ppm hydrogen sulphide ATEX approved C01781 Eikon CO, 0-500ppm carbon monoxide ATEX approved C01782 Eikon O2, 0-25% oxygen ATEX approved C01809 Eikon CO/H2S carbon monoxide/hydrogen sulphide ATEX approved C01904 Eikon NH3, 0-50ppm ammonia ATEX approved C01900 Eikon Cl2, 0-5ppm chlorine ATEX approved C01870 Eikon H2S, 0-50ppm hydrogen sulphide CSA approved C01871 Eikon CO, 0-500ppm carbon monoxide CSA approved C01872 Eikon O2, 0-25% oxygen CSA approved C01812 Eikon H2S, 0-50ppm hydrogen sulphide UL approved C01813 Eikon CO, 0-500ppm carbon monoxide UL approved C01814 Eikon O2, 0-25% oxygen UL approved C01905 Eikon NH3, 0-50ppm ammonia UL approved C01901 Eikon Cl2, 0-5ppm chlorine UL approved Crowcon reserves the right to change the design or specification of the product without notice. US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected] NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected] SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected] CN: Unit 316, Area 1, Tower B, Chuangxin Building, 12 Hongda North Road, Beijing Economic & Technological Development Area, Beijing, PRC 100176 +86 10 6787 0335 [email protected] www.crowcon.com P01018 GB Issue 11, Oct11 Area reserved for distributor stamp CO2 H2S CI2 NH3 O3 CO Gasman Monitor de gases individual O2 para proteção pessoal CH4 Gases tóxicos, oxigênio e inflamáveis SO2 CO2 H2S Gasman Com uma construção robusta à prova de impactos e em conformidade com IP65, o Gasman oferece uma vasta gama de gases que inclui seis opções de calibração de inflamáveis. Projetado para uso nos ambientes mais agressivos, o Gasman fornece uma combinação imbatível de alarmes com iluminação clara e em sons altos com uso de um design extremamente compacto e leve. Simples S Robusto Operação com um único botão Visor fácil de ler e com iluminação de fundo para status de operações e diagnóstico de gases Aviso nítido de necessidade de calibração Revestimento robusto de policarbonato Modelação abrangente fornecendo resistência a fortes impactos Resistente à água e à poeira em conformidade com IP65 Alarmes Flexível Alarme sonoro 95dBA Alarme visual duplo vermelho/azul impressionante Alarme interno vibratório 2 níveis de alarme instantâneo e alarmes TWA para as versões tóxicas Soluções de sensores de oxigênio, tóxicos e inflamáveis Baterias com versões recarregáveis e de íons de lítio disponíveis Registros extensivos de eventos e dados Módulos de sensores inteligentes e completamente intercambiáveis Gasman Especificações: Gasman é uma linha de monitores pessoais de gases compactos e robustos que foi projetada para ser usada nos ambientes mais agressivos. ,QÀDPiYHLVJ7y[LFRVJ 2[LJrQLRJ0RQy[LGRGHFDUERQRJ [[PP$[/[3 Peso Dimensões Tempos de resposta ,QÀDPiYHLVV*DVHVWy[LFRVV2[LJrQLRV típicos (T90) Gases e faixas Alarmes sonoros As faixas e os alarmes requeridos podem variar de acordo com o país HDDSOLFDomRHSRGHPVHUFRQ¿JXUDGRVFRQIRUPHQHFHVViULR&DGD FDQDOGHJiVSRGHWHUGRLVQtYHLVGHDODUPHLQVWDQWkQHRGH¿QLGRV$V unidades tóxicas também possuem alarmes Time Weighted Average (TWA – concentração média ponderada pelo tempo). 95 dBA Diversos sons de alarme permitem uma seleção de tons distintos para níveis de alarmes diferentes Alarmes visuais /('VSLVFDQWHVGHFRUGXSODYHUPHOKRD]XOHPSHULJRGH vazamento de gases Alarme vibratório Alarme vibratório interno Visor /&'SHUVRQDOL]DGDFRPOX]GHIXQGRHFRPH[LELomRGD FRQFHQWUDomRGHJiV6tPERORVJUi¿FRVSDUDEDWHULDFRP indicação proporcional do tempo restante de operação) e modo de exibição. Indicação na inicialização quando a calibração for QHFHVViULDHPGLDVTXDQGRDFDOLEUDomRHVWLYHUDWUDVDGDRX quando algum serviço for necessário Modos de Visor Visor normal para níveis de concentração de gases em tempo real. Memória de visor para leituras de pico e TWA Log de dados /RJGHGDGRVFRPSOHWDPHQWHFURQRPHWUDGRFRPWD[DGH DPRVWUDDMXVWiYHOGH¿QLGDFRPRWD[DGHGDGRVGHPLQXWR como padrão. $UPD]HQDPHQWRGHKRUDVHPLQWHUYDORGHPLQ PLOORJV!HYHQWRV Bateria Bateria de íon de lítio recarregável para todos tipos de gases Bateria de lítio não recarregável para tóxicos e oxigênio (excluindo CO2) Tempo de operação 5HFDUUHJiYHO0tQLPRGHKRUDVSDUDXQLGDGHLQÀDPiYHO Não recarregável: Até 2 anos Observação: O tempo de operação dependerá do padrão de funcionamento e da ocorrências de alarmes. Alarmes frequentes, ou de longa duração, e o uso do bipe de FRQ¿UPDomRRSFLRQDOUHGX]LUmRDYLGD~WLOGDEDWHULD Amostragem Aspirador manual opcional Temp. operacional faixa -20°C a +65°C 6HQVRUHVGHJDVHVWy[LFRVHR[LJrQLRQmRHVWmRFODVVL¿FDGRV SDUDRSHUDomRFRQWtQXDHPWHPSHUDWXUDVDOWDV(QWUHHP contato com a Crowcon se as temperaturas operacionais excederem 40°C por períodos longos $FDOLEUDomRGHJDVHVLQÀDPiYHLVHVWiGLVSRQtYHOSDUDPHWDQR propano, butano, pentano, hidrogênio e etileno como padrão. O Gasman também está disponível na versão de área segura de CO2 oferecendo a medição de dióxido de carbono de 0-5%. Alarmes e faixas típicos Gás Faixa Alarme típico (Reino Unido) Inflamáveis 0-100% LIE 20% LIE Oxigênio 0-25% 19/23% Sulfureto de hidrogénio 0-100 ppm 5 ppm Monóxido de carbono 0-500 ppm 30 ppm Dióxido de enxofre 0-20 ppm 1 ppm Cloro 0-20 ppm 0,5 ppm Dióxido de nitrogênio 0-20 ppm 1 ppm Amônia 0-100 ppm 25 ppm Ozônio 0-1 ppm 0,1 ppm Hidrogênio 0-2000 ppm N/A Cianeto de hidrogênio 0-25 ppm 5 ppm Fluoreto de hidrogênio 0-10 ppm 1 ppm Fosfina 0,2 ppm Umidade 20-90% UR 0,1 ppm Proteção contra líquidos e poeira IP65 0-5 ppm Flúor 0-1 ppm Fosgênio 0-1 ppm 0,1 ppm Óxido nítrico 0-100 ppm 25 ppm Dióxido de carbono 0-5% 0,5 ppm Kit de Teste de Gás O Kit de Teste de Gás fornece uma forma simples e conveniente de realizar um teste de pré-uso de resposta (bump) ou uma calibração. Opções de recarregamento O Gasman pode ser fornecido com: t Carregador de unidade individual com plugues para Reino Unido, Europa ou EUA ou alimentação cabeada de 110 V/230 V t Carregador Comms com opções conforme acima incluindo interface de PC t Multicarregador de 5 vias com alimentação universal t Adaptador para carregamento em veículos Códigos de aprovação Tóxicos/O2: $7(;,,*([LD,,&7*D Europa &7D&%$6(()$$7(; ,QÀDPiYHLV$7(;,,*([LDG,,&7*E &7D&%$6(()$$7(; Internacional Tóxicos/O2: ,(&([%$6 ,QÀDPiYHLV,(&([%$6 EUA &ODVVH,&6$*UXSRV$%&''LYLVmR Segurança padrão Europa (1(1(1(& EUA &6$ Padrões de operação (1(1,(&(1(1 Interface de PC &RQH[mR56GRPyGXORGHLQWHUIDFHQRFDUUHJDGRU &RQYHUVRU5686%GLVSRQtYHO Calibração O Gasman pode ser calibrado com frequência com o software Portables PC ou utilizando o Checkbox IMH Acessórios O Gasman é fornecido com um agrafo integral Acessórios opcionais Arreios para capacete, placa de arreios universal, alça de ombro, coleira para peito, estojo de couro, conjunto de aspirador FKDSDGHÀX[ROkPSDGDHWXERGHPH.LWGH7HVWHGH*iV A Crowcon se reserva o direito de alterar o design ou as especificações do produto sem aviso prévio. UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected] US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected] NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected] SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected] www.crowcon.com P01019 BR Edição 8, 2010 217142066 217145674 [email protected] www.ERT.pt Area reserved for distributor stamp Rua Soeiro Pereira Gomes, Lote 5, Cave Drt. P2845-387 Amora Portugal CO2 H2S CI2 NH3 4 Gas Personal Monitor Oxygen, Toxic and Flammable Gases O3 CO O2 CH4 SO2 CO2 H2S Proven to serve the needs of today’s most arduous industrial environments. Designed with the user in mind, the top mount display, full function data and event logs, audible, visual and vibrating alarms deliver top end performance in a small and lightweight package. T3 features: Robust t Tough over-moulded contraction to resist shock and vibration t Water and dust resistant to IP65 and IP67 Alarms t 95dB Audible Alarm t Piercingly bright red/blue visable alarm t Vibrating alarm Reliable t Proven sensor technology and software operation t ‘At a glance’ operating status t Clear calibration due warning Performance t Li-ion battery with at least 14 hours operation t True single button operation t Easy to read back-lit display for gas readings and diagnostics Specification Tetra 3 is an intuitive 4 gas personal monitor with a top mount display designed to withstand the harshest of industrial environments. Gases and Ranges Ranges and alarms may vary by country and application which can be configurated as required. Each channel can have two instantaneous alarms. Toxic channels also have TWA alarms. Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and ethylene as standard. * T3 is available in a safe area CO2 version offering 0-5% carbon dioxide measurement. The CO2 sensor replaces the flammable option and can be supplied with oxygen and toxic sensors. Gas Flam O2 H2S CO SO2 O3 NH3 *CO2 Range 0-100% LEL 0-25% 0-100ppm 0-500ppm 0-20ppm 0-1ppm 0-100ppm 0-5% Typical Alarm (UK) 20% 19/23.5% 5ppm 30ppm 1ppm 0.1ppm 25ppm 0.5% Gas Test Kit Weight Dimensions 295g (10.4oz) 114 x 71 x 48mm (tapers to 20mm) 4.5 x 2.8 x 1.9 inches Audible Alarms 95dB Multiple alarm sounds allow selection of distinctive tones for different alarm levels Visible Alarms Dual colour red/blue flashing LED in gas hazard Vibrating Alarm Internal vibrating alarm Display Graphic LCD with backlight, giving simultaneous display for all gas channels. Graphic symbols for battery (with proportional indication of remaining operation time), healthy operation or fault warning. Start up indication when calibration is due, overdue, or service required Display Mode Normal display for real time gas concentration levels. Display recall for Peak readings and TWA Datalogging Timed datalogging: 50 hours at 1-minute data rate (3000 records) Threshold logging (starts after adjustable preset level) Event logging: >1500 events Battery Rechargable Li-ion battery Operating Time Based on four gas unit with flammable sensor A 5 hour charge from flat provides at least 10 hours of continuous use. A 12 hour charge provides at least 14 hours of continuous use Sampling Diffusion or hand aspirator Operating Temp. Range -20°C to +55°C (-4°F to +131°F) Toxic and Oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods Humidity 20-90% RH @ 40°C non-condensing The Gas Test Kit provides a simple and convenient means of carrying out either a pre-use (bump) test or a simultaneous four gas calibration (flam, O2, H2S, CO only). Ingress Protection IP65 and IP67 Charging Options International The T3 can be supplied with: t Single way drop in charger with UK, EU or US plug or in-line 110V/220V supply t Single way drop in charger with options as above including PC interface t 5 way multi-charger with universal power supply t Vehicle adapter for in-vehicle charging t NEW – Universal charger for vehicle, wall and desk mounting with a multi-region plug (supplied with EU/UK/US inserts) and status indication North America Contact Crowcon for further information. web: www.crowcon.com Approval Codes Europe ATEX II 2 G Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +55°C) BASEEFA05ATEX0187 IECEx Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +55°C) BAS05.0059 CSA Class I Division 1 Groups A, B, C, D Safety Standards Europe North America Operation Standards EN60079-0, EN60079-11, EN60079-1, 94/9/EC CSA22.2, 152 EN50270, EN50271, EN50104, EN45544, EN60079, IEC61508 PC Interface RS232 connection from interface module in charger RS232/USB converter available Calibration Tetra 3 can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH Accessories Tetra 3 is supplied with an integral alligator clip Optional Accessories Universal harness plate, shoulder strap, chest harness, aspirator assembly (flow plate, bulb and 2m/6ft tubing), fixed and telescopic sample probes, and an in-line water trap Crowcon reserves the right to change the design or specification of this product without notice UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected] US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected] NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected] 217142066 217145674 [email protected] www.ERT.pt Area reserved for distributor stamp SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected] PO1024 GB Issue 7 Jan 2010 Rua Soeiro Pereira Gomes, Lote 5, Cave Drt. P2845-387 Amora Portugal O2 H2S CO CH4 SO2 Monitor de Entrada de Espaço Confinado Detector portátil de 5 gases NH3 CO2 O3 CI2 NO2 Gas-Pro Projetado para atender as necessidades de trabalhadores e gerentes encarregados de trabalhos em espaços confinados, o Gas-Pro oferece a detecção de até 5 gases em uma solução compacta e robusta capaz de suportar ambientes agressivos e uso diário. Solução para Espaços Confinados t t t t t t t t Display fácil de visualizar posicionado no topo Bomba interna (opção) Reconhecimento automático de falha de fluxo no adaptador de vazão Modo de pré-entrada específico e único Indicador de status tricolor +ve SafetyTM (Segurança Positiva) Totalmente revestido por estojo à prova de choque Operação simples por um único botão Soluções de teste de gás portáteis, de parede e de mesa Flexível t t t +ve SafetyTM personalizado para os requisitos organizacionais Monitore 5 gases de várias diferentes opções Soluções multiuso; bombeadas e de difusão que oferecem vários usos em um detector compacto Gas-Pro Monitor de entrada de espaço confinado compacto e robusto capaz de detectar até 5 gases. Gases e Faixas Especificações: Gas-Pro oferece uma vasta gama de sensores, alguns deles são demonstrados abaixo. Gases e faixas podem variar de acordo com o país e aplicação. Cada canal de gás possui dois alarmes instantâneos com canais tóxicos que também contém alarmes TWA. Gas Faixa Alarmes Típicos Resolução Tóxico duplo H2S 0-100 ppm CO 0-500 ppm 5 ppm 30 ppm 1 ppm 1 ppm Oxigênio 0-25% VOL 19%/23% VOL 0,1% VOL Inflamável 0-100% LIE 20% LIE 1% LIE Dióxido de carbono 0-5% VOL 0,5% VOL 0,01% VOL * Agendado para liberação (entre em contato com a Crowcon para prazo de execução) Tamanho 43 x 130 x 84 mm (1.7 x 5.1 x 3.3) Peso 309g 4 gases (10.8oz) /340g com bomba (11.9oz) 333g (11.7oz) com bomba (5 gases) /362g com bomba (12.7oz) Alarmes Sonoro >95dB @ 30 cm (98dB@30 cm em volume alto) Visual – LEDs duplas de todos ângulos vermelha/azul Alerta de vibração Visor Montagem superior para fácil visualização Com luz de fundo com duas cores (verde/vermelho) Registro de dados 125hrs em intervalos de 10 segundos (45.000 registros) Amônia 0-100 ppm 25 ppm 1 ppm Dióxido de enxofre 0-20 ppm 1 ppm 0.1 ppm Registro de eventos Alarme, sobre faixa, calibração, bomba, liga/desliga, TWA, 1000 eventos Ozônio 0-1 ppm 0,1 ppm 0,01 ppm Bateria Cloro 0-5 ppm 0,5 ppm 0,1 ppm Dióxido de cloro 0-1 ppm 0,1 ppm 0,1 ppm Óxido nítrico 0-100 ppm 25 ppm 1 ppm Íon de lítio recarregável, >14 hrs (13 hrs de operação bombeada) com base em CH4, O2, H2S, CO O tempo para recarga das baterias menos de 7.5 horas Dióxido de nitrogênio 0-20 ppm 1 ppm 0,5 ppm Amostragem Bomba interna opcional Temperatura operacional -20OC a +55OC (-4˚C a +131˚F)+ Armazenamento -25OC a +65OC (-13˚F a +149˚F) Umidade 10 a 95% RH*+ Proteção contra líquidos e poeira Testados independetemente para IP65 & IP67 Aprovações (pendentes) IECEx: Ex ia d IIC T4 Gb Tamb -20˚C a +55˚C ATEX: II 2G Ex ia d IIC T4 Gb Tamb -20˚C a +55˚C UL: Gas detector use in hazardous locations Classe 1, Div. 1, Grupos A, B, C, D only as to intrinsic safety Conformidade FCC e CE. Em conformidade com a diretiva EMC 2004/108/EC EN50270 e ICED-003 Interface Conexão de dados para soluções de teste de gás e direta ao PC Carregador/ Adaptador Conecta diretamente com fornecimento de energia de multiregião Adaptador para carregamento em veículos Suporte para mesa Cabo de comunicações e de USB * Calibrações pellistor disponíveis para metano. Outras calibrações (butano, pentano, propane e etileno) e tipos de gás estão disponíveis, entre em contato com a Crowcon para obter detalhes. Soluções de Teste de Gás Soluções para teste de gás no campo e no próprio local, calibração e captura de dados Q-Test: Teste no próprio campo rápido e fácil I-Test: Estação inteligente de montagem de mesa ou parede S-Test: Serviço e manutenção de até 5 detectores + UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected] US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected] NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected] SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected] CN: Unit 316, Area 1, Tower B, Chuangxin Building, 12 Hongda North Road, Beijing Economic & Technological Development Area, Beijing, PRC 100176 +86 10 6787 0335 [email protected] dependente do sensor de configuração 217142066 217145674 [email protected] www.ERT.pt Área reservado para o selo do distribuidor Rua Soeiro Pereira Gomes, Lote 5, Cave Drt. P2845-387 Amora Portugal www.crowcon.com A Crowcon se reserva o direito de alterar o design ou as especificações do produto sem aviso prévio. P08013/Edição 1 BP – Setembro 2011 O Gas-Pro está em estágio de aprovação, portanto os dados incluídos na especificação são padrões, e poderão ser revisados na conclusão CO2 H2S CI2 Tetra NH3 O3 CO Personal Multigas Monitor O2 Oxygen, Toxic & Flammable Gases CH4 SO2 CO2 H2S TETRA Tetra is a single button, reliable and robust multigas monitor with optional internal pump. Featuring intelligent sensor modules, shockproof construction and self checking software, Tetra is simple to use and assures reliable gas detection in the toughest of environments. Simple Single button operation Easy to read backlit display for gas readings and diagnostics Clear calibration due warning Rechargeable Li-ion battery gives 12 hours of continuous operation Alarms Loud 94dBA audible alarm Ultra bright dual red/blue visual alarm Vibrating alarm Robust Rugged plastic housing with flexible internal assembly to resist shock and vibration Durable over moulded rubber for added protection Water and dust resistant to IP65 Flexible Optional built-in pump Rechargeable and alkaline battery versions available Compatible with Crowcon Portables PC Software Fully interchangeable intelligent sensor modules TETRA Specification: Tetra is a personal multigas monitor with an optional built-in pump designed to reliably detect gas in the toughest of environments. Gases and Ranges Required ranges and alarms may vary by country and application and can be configured as required. Each gas channel can have two instantaneous alarm levels set. Toxic channels also have Time Weighted Average (TWA) alarms. Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and ethylene as standard. Weight Dimensions 498g (1.1lb) Rechargeable 122 x 128 x 57mm (4.75 x 5 x 2.25 inches) Non-rechargeable 134 x 128 x 57mm (5.25 x 5 x 2.25 inches) Typical Response Times (T90) Flammable 20 s, Toxic gas 20 s, Oxygen 10 s Audible Alarms 94dB Multiple alarm sounds allow selection of distinctive tones for different alarm levels Visible Alarms 'XDOFRORXUUHGEOXHÀDVKLQJ/('LQJDVKD]DUG Vibrating Alarm Internal vibrating alarm Display 128 x 64 graphic LCD with backlight, giving simultaneous display for all gas channels. Graphic symbols for battery (with proportional indication of remaining operation time), pump operation, healthy operation or fault warning. Start up indication when calibration is due within 30 days, calibration overdue, or service required. Display Mode Normal display for real time gas concentration levels. Display recall for the Peak readings and TWA. Datalogging Timed datalogging: 50 hours at 1-minute data rate Event logging >1500 events Battery Types Rechargeable Li-ion battery Non rechargeable pack 3xAA Alkaline cells Operating Time Rechargeable - 12 hour minimum based on pumped IRXUJDVXQLWZLWKÀDPPDEOHVHQVRU Tetra is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement. Typical ranges and alarms Gas Range Standard Alarm (UK) Flammable 0-100% LEL 20% LEL Oxygen 0-25% 19/23% Hydrogen sulphide 0-100ppm 5ppm Carbon monoxide 0-500ppm 30ppm Sulphur dioxide 0-20ppm 1ppm Chlorine 0-20ppm 0.5ppm Nitrogen dioxide 0-20ppm 1ppm Sampling Hand aspirator or internal electric sampling pump Ammonia 0-100ppm 25ppm Operating Temperature Range Ozone* 0-1ppm 0.1ppm Hydrogen 0-1000pm N/A -20OC to +55OC (-4OF to +131OF) Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperature are likely to exceed 40OC (104OF) for extended periods. Hydrogen cyanide 0-25ppm 5ppm Humidity 20-90% RH Hydrogen fluoride 0-10ppm 1ppm Ingress Protection IP65 Approval Codes Europe Phosphine 0-5ppm 0.2ppm Fluorine 0-1ppm 0.1ppm Phosgene 0-1ppm 0.1ppm Carbon dioxide 0-5% 0.5% North America ATEX II 2G Ex ia d IIC T4 Gb ( -20OC ≤ Ta ≤ 55Oc) BASEEFA 03ATEX0193 IECEX Ex ia d IIC T4 Gb ( -20OC ≤ Ta ≤ 55Oc) BAS04.0024 CSA UL/cUL Class I Division I Groups A, B, C, D Safety Standards Europe EN60079-0, EN60079-11, EN60079-1, 94/9/EC North America UL913, CSA22.2, 152 Operation Standards EN50270, EN50271, IEC61508, EN61779, EN45544 International Gas Test Kit * unpumped only The Gas Test Kit provides a simple and convenient means of carrying out either a pre-use (bump) test or a simultaneous four gas calibration (flammable, oxygen, hydrogen sulphide and carbon monoxide only). PC Interface and Calibration Tetra can be routinely calibrated either manually or by using Crowcon Portables PC software or Checkbox IMH packages, providing the user with full configuration control, calibration and access to data and event logs files. An IR link is available using a RS232/USB connection from the PC. Charging Options The Tetra can be supplied with: t Plug in charging power supplies with UK, EU or US plug or in-line 110V/230V supply t 10-way multicharger with 90-260V in-line power supply with either UK, EU or US mains lead t Vehicle lighter socket charger for in-vehicle charging Calibrations Tetra can be routinely calibrated manually using the menu, using Crowcon Protables PC software or automatically using Checkbox IMH. Accessories Tetra is supplied with an integral belt/pocket clip. Pumped units are supplied with a sampling kit ÀRZSODWHDQGPIWWXELQJ Optional Accessories Universal harness plate, shoulder strap, chest KDUQHVVFDUU\FDVHDVSLUDWRUDVVHPEO\ÀRZSODWH EXOE DQGPIWWXELQJ¿[HGDQGWHOHVFRSLFVDPSOH probes and an in-line water trap. Crowcon reserves the right to change the design or specification of the product without notice. 217142066 217145674 [email protected] www.ERT.pt Area reserved for distributor stamp UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected] US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected] NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected] SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected] www.crowcon.com PO1017 GB Issue 10 May 2010 Rua Soeiro Pereira Gomes, Lote 5, Cave Drt. P2845-387 Amora Portugal CO2 H2S CI2 Triple Plus+ NH3 O3 Portable Monitor Oxygen, Toxic and Flammable Gases CO O2 CH4 SO2 CO2 H2S Triple Plus+ With over 60,000 units in use worldwide, our customers have come to depend on the robust and reliable performance of the Triple Plus+. The extremely durable Triax™ case and internal construction makes the Triple Plus+ an industry favourite known for the ability to withstand even the most demanding of applications. Benefits t Simple customisation to alternative flammable gas correction factors t Wide range of sensor types allowing 4 gas detection t QuickCal – simple rapid calibration t Peak hold capability for pre-entry checks Triple Plus+ features: Rugged construction t Triax™ casing will not crack or shatter when dropped t Unique internal design will resist the harshest treatment t Full buoyancy makes recovery from water possible Flexible t Available for diffusion, manual aspiration or pumped sampling t Interchangeable sensor modules t Comprehensive datalogging with site and user names Convenient and simple to use t Large four channel simultaneous gas display t Piercing 85dBA @ 1m t Ultra bright LED alarms with top visibility t Confidence blip, low battery and TWA warnings t Simple Windows™ software interface Triple Plus+ Specification Triple Plus+ is a 4 gas personal monitor for oxygen, toxic and flammable gases used for personal safety around the globe. Gases and Ranges Ranges and alarms may vary by country and application which may be configured as required. Each channel can have up to three levels of alarm, including short and long TWA exposure levels for Toxic channels. Weight Dimensions 880 g (1.9 lb) 118 x 200 x 73mm (h x w x d) (4.65 x 7.8 x 2.9 inches) including strap hooks Approval Codes Europe North America ATEX II 2G: Ex ib d IIC T4 Gb Class I Division 1, Groups A, B, C, D Safety Standards Europe EN50014, EN50020, 94/9/EC, SFA3009, EN50081-2, EN50270, EN50082-2 UL 913, CSA 22.2 No.157 North America Ingress Protection IP65 A choice of 12 flammable correction factors are available via Portables PC. Typical response times Methane 20 s, Oxygen 10 s, Typical Toxic Gas 20 s Other sensors may be available. Expected sensor life Flammable 5 years, Toxic 3 years, Oxygen 2 years Audible Alarms Piercing, rapid intermittent, piezo-electric tone, 85 dBA at 1 m Confidence blip (selectable) Distinctive double blip for low battery with user accept Visible Alarms Ultra bright flashing red LED in gas hazard Slow flashing green LED indicates instrument is working Distinctive double flash of green LED indicates low battery Display 2 lines of 24 characters, dot matrix high contrast LCD with back light operating for 30 minutes. Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels. Low battery, pump failure, real time and elapsed time, calibration and configuration data also displayed Datalogging Adjustable sample rate, 100 hours @ 1 minute sample rate (maximum 6000 data points per channel), logging of events, user and site NEW LIBRA Li-Ion rechargeable battery pack Battery Life: Standard instrument >12 hours Pumped instrument >10 hours Battery Charging Dual rate ‘drop in’ charger Dual rate charger/PC interface Electric pump Optional internal pump with on/off button Gas Flam H2 (electrochem) CH4 O2 H2S CO SO2 Cl2* NO2 PH3 NH3 H2 (non-Flammable) HCN HCl F2 HF ETO ClO2 NO Range 0-100% LEL 0-100% LEL 0-100% vol 0-25% 0-50ppm 0-500ppm 0-10ppm 0-5ppm 0-10ppm 0-2ppm 0-50ppm 0-2000ppm 0-25ppm 0-10ppm 0-10ppm 0-10ppm 0-10ppm 0-1ppm 0-100ppm Typical Alarm (UK) 20% LEL 20% LEL 19%/23% 5ppm 30ppm 1ppm 0.5ppm 1ppm 0.1ppm 25ppm N/A 10ppm 1ppm 1ppm 2ppm 5ppm 0.1ppm 25ppm *Unpumped units only Charging Options Operating Temp. Range -20°C to +50°C (-4°F to 122°F) Humidity 20–90% RH non-condensing The Triple Plus+ has two dual rate charging solutions supplied with UK, EU, US plug and without plug configurations. A vehicle adapter for in-vehicle charging is also available. tStandard drop in charging cradle tPC interface charger PC Interface RS232 connection via the interface charger. RS232/USB converter available. Portables PC also controls datalogging, giving the user a choice of direct graphical output or a datafile compatible with all leading spreadsheets Calibration Triple Plus+ can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH NEW LIBRA Li-Ion Battery Pack Accessories Supplied as standard: manual, shoulder strap and allen keys (pumped units include additional flow plate, 2m hose and pouch) Optional Accessories Leather carry case, straight and telescopic probes, water trap, baffle plate, aspirator, calibration flow adaptor and hose Available in new builds from April , the new LIBRA battery pack offers extended lifetime and charge cycles. Also designed to replace lead acid batteries in existing units, the LIBRA has solved the reduced lifetime effects of changes in Lead Acid technology during recent years. Compatible with Triple Plus+ and Triple Plus+ IR units whist maintaining certification levels, the LIBRA charges with the existing charger units and takes only seconds to replace. Crowcon reserves the right to change the design or specification of this product without notice Contact Crowcon for further information. 217142066 217145674 [email protected] Area reserved for distributor stamp web: www.crowcon.com UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected] US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected] NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected] SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected] P01005 GB Issue 11 02/10 www.ERT.pt Rua Soeiro Pereira Gomes, Lote 5, Cave Drt. P2845-387 Amora Portugal CO2 H2S CI2 Triple Plus+ IR NH3 O3 Portable Monitor Flammable Hydrocarbons Carbon Dioxide, Oxygen, and Toxic Gases CO O2 CH4 SO2 CO2 H2S Triple Plus+ IR Incorporating infrared detection technology the Triple Plus+ IR extends the capability of the Triple Plus family of products allowing extended life detection of hydrocarbons and carbon dioxide. The infrared hydrocarbon sensor offers measurement in inert backgrounds at both %LEL and %volume levels for tank purging and inert atmosphere monitoring. Infrared hydrocarbon sensor benefits t Volume % measurement for purging applications t %LEL measurement in air or inert backgrounds t Single or dual range measurement t No poisoning effects t Reduced cost of ownership – long life sensor and no burnout t IR CO2 detection, 0–2% Triple Plus + IR features: Rugged construction t Triax™ casing will not crack or shatter when dropped t Unique internal design will resist the harshest treatment t Full buoyancy makes recovery from water possible Flexible t Available for diffusion, manual aspiration or pumped sampling t Interchangeable sensor modules t Comprehensive datalogging with site and user names Convenient and simple to use t Large four channel simultaneous gas display t Piercing 85dBA @ 1m t Ultra bright LED alarms with top visibility t Confidence blip, low battery and TWA warnings t Simple Windows™ software interface Triple Plus+ IR Specification Triple Plus+ IR is a 4 channel personal monitor for flammable hydrocarbons, oxygen and toxic gases offering single or dual flammable ranges. Gases and Ranges Ranges and alarms may vary by country and application which may be configured as required. Each channel can have up to three levels of alarm, including short and long TWA exposure levels for Toxic channels. Flammable sensors are offered as a single (0-100% LEL) or dual range (0-100% LEL and 0-100% Volume) which occupies two channels. Flammable gas calibrations are available for methane, butane, acetylene, pentane (% LEL only), propane and ethylene. Other sensors may be available. A CO2 IR sensor can be fitted in the place of the Flammable IR sensor (only one IR sensor may be fitted in the unit). Gas Flam Flam CO2 O2 H2S CO SO2 Cl2* NO2 PH3 NH3 H2 (non-Flammable) HCN HCl Range 0-100% LEL 0-100% vol 0-2% 0-25% 0-50ppm 0-500ppm 0-10ppm 0-5ppm 0-10ppm 0-2ppm 0-50ppm 0-2000ppm 0-25ppm 0-10ppm Typical Alarm (UK) 20% LEL No alarm 0.5/1.5% 19%/23% 5ppm 30ppm 1ppm 0.5ppm 1ppm 0.1ppm 25ppm N/A 10ppm 1ppm *Unpumped units only Charging Options Weight Dimensions 880 g (1.9 lb) 118 x 200 x 73mm (h x w x d) (4.65 x 7.8 x 2.9 inches) including strap hooks Approval Codes Europe North America ATEX II 2G: Ex ib d IIC T4 Gb Class I Division 1, Groups A, B, C, D Safety Standards Europe EN50014, EN50020, 94/9/EC, EN50081-2, EN50270, EN50082-2, EN50270 UL 913, CSA 22.2 No.157 North America Ingress Protection IP65 Typical response times IR 20 s, Oxygen 10 s, Typical Toxic Gas 20 s Expected sensor life IR 5 years, Toxic 3 years, Oxygen 2 years Audible Alarms Piercing, rapid intermittent, piezo-electric tone, 85 dBA at 1 m Confidence blip (selectable) Distinctive double blip for low battery with user accept Visible Alarms Ultra bright flashing red LED in gas hazard Slow flashing green LED indicates instrument is working Distinctive double flash of green LED indicates low battery Display 2 lines of 24 characters, dot matrix high contrast LCD with back light operating for 30 minutes. Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels. Low battery, pump failure, real time and elapsed time, calibration and configuration data also displayed Datalogging Adjustable sample rate, 100 hours @ 1 minute sample rate (maximum 6000 data points per channel), logging of events, user and site NEW LIBRA Li-Ion rechargeable battery pack Battery Life: Standard instrument >12 hours Pumped instrument >10 hours Battery Charging Dual rate ‘drop in’ charger Dual rate charger/PC interface Electric Pump Optional internal pump with on/off button Operating Temp. Range -20°C to +50°C (-4°F to 122°F) Humidity 20–90% RH non-condensing The Triple Plus+ IR has two dual rate charging solutions supplied with UK, EU, US plug and without plug configurations. A vehicle adapter for in-vehicle charging is also available. tStandard drop in charging cradle tPC interface charger PC Interface RS232 connection via the interface charger. RS232/USB converter available. Portables PC also controls datalogging, giving the user a choice of direct graphical output or a datafile compatible with all leading spreadsheets Calibration Triple Plus+ IR can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH NEW LIBRA Li-Ion Battery Pack Accessories Supplied as standard: manual, shoulder strap and allen keys (pumped units include additional flow plate, 2m hose and pouch) Optional Accessories Leather carry case, straight and telescopic probes, water trap, baffle plate, aspirator, calibration flow adaptor and hose Available in new builds from April, the new LIBRA battery pack offers extended lifetime and charge cycles. Also designed to replace lead acid batteries in existing units, the LIBRA has solved the reduced lifetime effects of changes in Lead Acid technology during recent years. Compatible with Triple Plus+ and Triple Plus+ IR units whist maintaining certification levels, the LIBRA charges with the existing charger units and takes only seconds to replace. Contact Crowcon for further information. Crowcon reserves the right to change the design or specification of this product without notice 217142066 217145674 web: www.crowcon.com UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected] US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected] NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected] SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected] P01014GB Issue 9 10/10 [email protected] www.ERT.pt Area reserved for distributor stamp Rua Soeiro Pereira Gomes, Lote 5, Cave Drt. P2845-387 Amora Portugal Transportable Multi-gas area monitor Detective + A transportable area monitor you can trust /RXGDQGEULJKWDODUPV ,QKHUHQWO\UXJJHGDQGUHOLDEOH :LGHVHQVRURSWLRQVLQFOXGLQJLQIUDUHG %XLOWLQSXPSRSWLRQ )ROGLQJRUIL[HGOHJV Used singly or linked together, Detective+ gives a loud and clear alarm providing effective warning of gas hazards. The rugged, water and impact resistant design and clear display make Detective+ the ideal choice for your transportable gas detection needs. Superb pedigree Detective+ is based on the highly successful Triple Plus+ multi-gas monitor which has sold over 55,000 units worldwide Versatile and user friendly Infra-red sensors available - allows sampling of potentially high flammable gas levels and CO2 - infra-red sensors are unaffected by poisoning Built-in pump option provides fast response and extra sensor protection Display provides clear information, allows identification of gas hazard Easy tracking of multiple hazards up to 60 hour battery operation Wide range of toxic gas sensors available Extremely loud and clear alarms Wailing omni-directional siren, 104 dBA @1 metre High intensity red LED clusters provide visual alarm indication All linked Detective+ units indicate an alarm sensed by any one unit Units actually sensing alarm have faster LED flash Audible and visible confidence blip Time weighted average alarms for 8 hours and 15 minutes averages Uniquely rugged, tripod construction Detectors are fully protected, even if device is overturned Raised detectors prevent water ingress Easy and quick to set up Folding or fixed leg options provide easy storage and transportation Transportable multi-gas monitor Detective+ Specification Weight 7.5 kg (19lb) Dimensions 640 h x 455 w x 455 d mm (25.2 x 17.9 x 17.9 inches) Typical measuring ranges and alarm settings (up to four gas measurement channels) Standard Range Flammable gas 0 – 100% LEL Oxygen 0 – 25% Hydrogen sulphide 0 – 50 ppm Carbon monoxide 0 – 500 ppm Sulphur dioxide 0 – 10 ppm Chlorine* 0 – 5 ppm Nitrogen dioxide 0 – 10 ppm Phosphine 0 – 5 ppm Ammonia 0 – 50 ppm Ammonia 0 – 1000 ppm Hydrogen (non0 – 2000 ppm flammable levels) Hydrogen cyanide 0 – 25 ppm Hydrogen chloride 0 – 10 ppm Chlorine Dioxide 0-1ppm Hydrogen Fluoride 0-10ppm Ethylene Oxide 0-10ppm Volatile Organic 0-100ppm channel) Logging of events, user and site data Typical Alarm Levels 20% LEL 19% & 23% 10 ppm 35 ppm 2 ppm 0.5 ppm 2 ppm 0.5 ppm 25 ppm N/A N/A 10 ppm 5 ppm 0.1ppm 1pm 5ppm N/A Menu Operating menu allows access to setting up of instrument operation Log Menu allows selection of Users and Sites from predefined lists, marking the log file with an event, and start or stop of data logging Configuration Menu allows selection of display and alarm modes, setting of alarms, zero and calibration, and selection of flammable gas correction factors from predefined list . Battery 6 V, 7.2 Ah Sealed lead acid battery pack Optional 6V, 12Ah high capacity pack Battery life Standard instrument: Up to 36 hours assuming flammable/CO2 sensor fitted with 7.2Ah battery. Up to 60 hours with optional 12Ah battery pack Battery charging Built-in battery charging circuit, dual rate 100 – 120 VAC and 200 - 250 V AC Input options available. (Safe Area operation only) Typical charge time: 12 hours Operating Temp. range -20°C to +40°C (-4°F to 104°F). Required ranges and alarms may vary by countryand application and these can be configured as required. Toxic and Oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods. Infrared Sensors Humidity Infrared sensors for flammable gas can be supplied as a single range, 0-100% LEL, utilising a single display channel, or as a dual range, 0-100% LEL/0100% volume, which then occupies two display channels. CO2 sensors are supplied as 0-5% volume. Only one IR sensor can be fitted, and IR sensors can only be used in combination with oxygen and toxic sensors Flammable Gas Flammable Gas Flammable Gas CO2 Standard Range Typical Alarm 0-100% LEL 20% LEL 0-100% v/v None available for methane, propane, butane or ethylene 0-5.0% v/v 0.5/1.5% v/v Typical response times Methane 20 s, Oxygen 10 s, typical toxic gas 20 s, IR 30 s Expected sensor life Flammable 5 years, Toxic 3 years, Oxygen 2 year minimum, IR >5 years Audible alarms Wailing, omni-directional siren, 104 dBA @ 1 metre. Visible alarms Three large, top-mounted red LED clusters and single red LED on control panel. In alarm mode LED clusters flash in quick succession LED clusters of linked Detectives repeating the alarm, flash more slowly than LED lights on those Detectives sensing the hazard. Slow flashing green LED indicates normal working. Rapid flashing green LED indicates low battery. Display High contrast LCD with back light 2 lines of 24 characters. Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels. Low battery, real time and elapsed time, calibration and configuration data also displayed Datalogging 0 – 95% RH non condensing Approvals Europe : ATEX II 2G EEx ib d IIC T4 USA and Canada : Class 1 Division 1 Groups A, B, C, D (Pending) Standards EN50014, EN50018, EN50020, EN50104, EN45544, UL913 (Pending) Ingress protection IP65 EMC EN 50270, FCC CFR47 Part 15, IC ICES03 PC Interface Detective+ has an in-built PC interface, which can be connected to the serial port of a computer using the optional RS232 lead. Portables PC software can be used to set alarms, clock, datalogging interval and password. Portables PC also controls datalogging, giving graphical display of instrument log file and allows file export to spreadsheet. Calibration Detective+ can be routinely calibrated quickly using its internal menu command, Portables PC or the Crowcon CheckBox IMH management system Accessories Baffle plate (to protect sensors) Interconnecting lead - 10 m standard, longer lengths up to 100m available Computer lead - RS232 serial link Portables PC software Aspirator Manual bulb and 2 m hose, both nonabsorbent and hydrocarbon resistant Internal electric sampling pump option includes external water trap and 2m hose, longer lengths available on request Linked Detectives Up to 12 units can be linked to provide perimeter or area monitoring Adjustable sample rate, 100 hours @ 1 minute sample rate (maximum 6000 data points per P01025GB Issue 2 07/09 UK Office Crowcon Detection Instruments Ltd 2 Blacklands Way Abingdon Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Tel: +44 (0) 1235 557700 Fax: +44 (0) 1235 557718 Email: [email protected] Web Site: www.crowcon.com USA Office Crowcon Detection Instruments Ltd 21 Kenton Lands Road Erlanger Kentucky 41018-1845 USA Tel: +1 859 957 1039 or 1-800-5-CROWCON Fax: +1 859 957 1044 Email: [email protected] Web Site: www.crowcon.us Crowcon reserves the right to change the design or specification of this product without notice 217142066 217145674 [email protected] www.ERT.pt Rua Soeiro Pereira Gomes, Lote 5, Cave Drt. P2845-387 Amora Portugal C2H5OH C 2H6 C3H8 Gas-Tec C4H10 C5H12 C6H14 CH4 Hydrocarbon gas detector for leak survey and localisation C7H16 C2H4 C3H6 Gas-Tec Gas-Tec is a portable gas detector for rapid survey and leak localisation. GPS, data and event logging allow survey teams to track progress and pinpoint areas of significant interest. Gas-Tec is worn over the shoulder and has a wide range of probes and accessories for all applications. Flame Ionisation Detector offering ppm level indication t Based on the tried, tested and trusted Gas-Tec engine t Enhanced electronic controls reduce hydrogen usage t Simple and intuitive functionality utilising LCD and softkey technology t Full data and event logging with simple drag and drop download t Rechargeable Li-Ion battery offers more than 22 hours operation t GPS logging for accurate location report of leaks. Gas-Tec is the next generation of flame ionisation detection. Offering users enhanced technology, Gas-Tec is the unique surveying solution. GPS: Enhances record keeping by assigning latitude, longitude and sea level to data readings. Users are also able to view the current location, offering the precise location to back-up crews for immediate leak management. Specifications: Description Hydrocarbon gas detector Sensor Flame Ionisation Detection (FID) Gas Calibrated to Methane (CH4) Other correction factors available Range 0 – 100 ppm 0 – 1000 ppm 0 – 10,000 ppm Accuracy +/- 10% Response time <2 seconds Hydrogen cylinder life UK & EU 400ml = 45 hrs EU 100ml = 11 hrs USA 300ml = 33 hrs Case High impact and UV resistant glass reinforced nylon Rugged and reliable: Ingress protected to IP54 for everyday use in all weather conditions. Size 385 x 205 x 125 mm (15.2 x 8 x 5 Inches) Weight 2.4kg without bottle (5.3lb) Enhanced electronic controls: Offering extended battery and cylinder life. Pressure and flow transducers manage H2 and sample flow rates. Ingress protection IP54 Audible alarm Rising tick increasing with presence of gas Visual alarms On LCD indication of status Backlight Adjustable intensity and time off delay Battery type Rechargeable Lithium-ion Battery life 22 hrs Data and event logging: Gas-Tec allows users the ability to download full survey information via the ‘drag and drop’ USB interface for survey traceability. Intuitive functionality: LCD and soft keys offering full sequence instruction, in-operation options, service and calibration set-up and alerts. Tried and tested: Based around the original Gas-Tec ‘engine’ detection method. The next generation is therefore already proven, fit for purpose and suited to the trials of every day use. Gas-Tec Accessories: Recharge time 2.5 hrs tTrigger Survey Kit: in-vehicle leak survey tool allowing detection up to 30km/hr. Operating temperature range -5⁰C to +55⁰C (23⁰F to 131⁰F) tEarphones: allow users to hear alarms in noisy areas and traffic. Humidity 20 to 95% RH non-condensing Sample input Via quick connect filtered coupling Outputs Headphone, USB and Trigger sockets Data / Event / GPS logging 21 million log entries giving over 700 days logging activity (assuming logging at 1 second intervals over an 8 hour shift) GPS Accurate to within 10m with 5 satellite lock EMC & approvals EN50270 & EN50271:2002 Industry approvals FCC and CE marked Calibration period Recommended every 6 months Warranty 12 months against faulty components or manufacture tSpare H2 Cylinders: offer extended usage in the field and reduce the need for regular refills. tProbe Assemblies: suitable for all applications. Bore hole, straight probe, cup attachment and detection trolley. tVehicle Charger: allowing on the move charging to maintain battery levels between surveys. Gas-Tec is supplied as standard in a wheeled ABS case with fitted foam insert. UK: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected] Area reserved for distributor stamp US: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected] NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected] SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected] www.crowcon.com Crowcon reserves the right to change the design or specification of the product without notice. P01107GB Issue 3 03/2011 LaserMethane®mini Gen2 Deteção de metano à distância LaserMethane® mini Gen2 Laser A segu segunda geração do LaserMethane® mini Gen2 da Crowcon está mudando a forma como os vazamentos de metano Crowco podem ser detectados. Utilizan Utilizando a tecnologia de laser, o LaserMethane® mini Gen2 (LMm) permite aos usuários detectar metano de maneira confiável e permit precisa, a uma distância segura. precisa Obtenh Obtenha resultados em segundos simplesmente apontando o feixe de laser lase em direção ao vazamento suspeito ou ao longo da linha inspeção. Esse processo elimina a necessidade de acesso a áreas de insp cercadas, em grandes alturas ou outras áreas difíceis de alcançar. cercada Segurança em primeiro lugar Flexível e conveniente t Medição e detecção remotas a até 100 metros t Não é necessário nenhum especialista ou equipamento de acesso especial para detectar vazamentos t Aprovado pela ATEX para uso industrial e agora inclui aplicações de mineração t Níveis de compensação e alarme programáveis pelo usuário t Bateria de longa duração – permite 6 horas de operação contínua com uma bateria t A verificação e a calibração automáticas ao ligar o detector economizam tempo e garantem a confiabilidade e um desempenho alto e consistente Fácil de usar t t t t Portátil – realmente fácil de transportar Projeto leve, compacto e robusto Menu intuitivo Mostrador gráfico ou numérico totalmente colorido Precisão e confiabilidade t Responde especificamente ao metano t Precisão excepcional – detecta até mesmo níveis muito baixos de metano t Baixo Tempo de Resposta - normalmente 0,1 segundo LaserMethane® mini Gen2 Especificação O LaserMethane® mini Gen2 da Crowcon detecta com precisão e confiabilidade vazamentos de gás à distância. O que era uma atividade que demandava tempo e recursos, agora pode ser concluída em questão de segundos. Princípio de medição Ao apontar o LaserMethane® mini Gen2 para um vazamento suspeito ou área de inspeção como uma tubulação de gás ou teto, a concentração de metano é medida através da detecção da diferença entre a luz emitida e a luz recebida. Para obter alta seletividade e sensibilidade de detecção para o metano, o LaserMethane® mini Gen2 usa um comprimento de onda que apresenta adsorção máxima e é exclusivo para metano. A densidade da coluna de metano é a concentração do metano entre o detector e o alvo e é o produto da concentração da nuvem de metano (ppm.m) e o comprimento do caminho que atravessa a nuvem (metros) e é relatado em unidades ppm.m. Alvo Gás metano Laser de medição Tamanho 70 x 179 x 42 mm, LxPxA Peso 600 g (1.3 lb), incluindo a bateria Gás alvo Metano (CH4) Método de detecção Espectroscópio de absorção a laser de diodo regulável (TDLAS) Distância de detecção Modo padrão 30 m Até 100 m com refletor Faixa de medição 1 – 50.000 ppm.m (dependendo do objeto refletor e da distância de detecção) Precisão da medição ±10% @ 100 ppm.m (2 m) ±10% @ 1000 ppm.m (2 m) Velocidade de detecção 0,1 segundo (aprox.) Alarme sonoro 72 dB a 76 dB @ 0,3 m e dependente do ângulo Aviso de reflexão Aviso de reflexão insuficiente, áudio e visual Mostrador Totalmente colorido e eletroluminescente Operação Funções por menu no display Bateria Recarregável de hidreto metálico de níquel Tempo de operação (laser ligado) Mínimo de 6 horas por carga (recarga de 4 horas) @ 25 °C no nível 5 do mostrador Temperatura de operação -17 °C 50 °C Umidade de operação 30% a 90% UR ATEX Corpo principal: II 2G Ex ib op-pr/op-is IIA T1 I M2 Ex ib op-pr/op-is IIA I Laser de reflexão j Conjunto de baterias: II 2G Ex ib IIA T1 Detetor LaserMethane® mini Gen2 I M2 Ex ib IIA I Aplicações típicas t Metano além do alcance, isto é, áreas difíceis de alcançar ou inacessíveis t Monitoramento de grandes áreas, por exemplo, inspeção de tubulações t Monitoramento de áreas perigosas, por exemplo, refinarias petroquímicas t Prevenção de desastres secundários, por exemplo, nuvens de gás acumuladas em espaços no teto de prédios em propriedades comerciais e industriais t Detecção de metano através de janelas ou caixas de correspondência de propriedades desocupadas Proteção de entrada IP54 CE CE 0344 EMC EN61326-1 : 2006 Segurança do laser IEC 60825-1 : 2001 Laser marcador: Comprimento de onda de saída de 650 nm Nível de saída: 1 mW (Classe 2) ou menos Laser de detecção: Comprimento de onda de saída de 1653 nm Nível de saída: 10 mW (Classe 1) ou menos Cuidado! NUNCA OLHE PARA O FEIXE DE LASER. Nunca aponte esse detector em direção ao sol. Produto padrão fornecido com: Carregador da bateria Manual do operador (Inglês, Japonês e Português como padrão) Bateria recarregável Alça Capa de proteção Extras opcionais Estojo de transporte Bateria extra Óculos de aprimoramento do laser Consulte o guia de aplicação do LaserMethane® para obter mais informações. RU: 2 Blacklands Way, Abingdon Business Park, Abingdon, OXON, OX14 1DY +44 (0) 1235 557700 [email protected] EUA: 21 Kenton Lands Road, Erlanger, Kentucky 41018-1845 +1 859 957 1039 [email protected] NL: Vlambloem 129, 3068JG, Rotterdam +31 10 421 1232 [email protected] SG: Block 194 Pandan Loop, #06-20 Pantech Industrial Complex, Singapore, 128383 +65 6745 2936 [email protected] CN: Unit 316, Area 1, Tower B, Chuangxin Building, 12 Hongda North Road, Beijing Economic & Technological Development Area, Beijing, PRC 100176 +86 10 6787 0335 [email protected] www.crowcon.com M07688 BP edição 4 11/11 As informações aqui contidas estão corretas no momento da impressão e estão sujeitas a alteração sem notificação prévia. Todas as informações aqui contidas foram impressas de acordo com o fabricante. Área reservada para o carimbo do distribuidor