SIT SE/GB/DE Kyldelsbyte BVP 511826.indd
Transcrição
SIT SE/GB/DE Kyldelsbyte BVP 511826.indd
SIT 0717-3 Kyldelsbyte BVP 511826 Kyldelsbyte Cooling section replacement Kühlteilwechsel SERVICEINSTRUKTION Kyldelsbyte bergvärmepumpar GB SERVICE INSTRUCTION Cooling section replacement ground source heat pumps DE SERVICE-INSTRUKTION Kühlteilwechsel Sole/Wasser - Wärmepumpen LEK SE SERVICEINSTRUKTION Kyldelsbyte bergvärmepumpar Allmänt Återmontering Anvisning för kyldelsbyte gällande NIBE bergvärmepumpar. 1. Återmontera utbyteskyldelen i omvänd ordning. ■ Vid utbyte av kyldel kan även en slangsats (se Tillbehör) krävas om värmepumpen är tillverkad före 2004-01-31 (serienummer XXXXXX04030XXX), kyldelar efter detta datum har conexanslutningar som standard. ■ Tillsammans med kyldelen medlevereras nytt pressostatkablage (lågtryck/drift) som vid behov ska användas till FIGHTER 1110/1115 och FIGHTER 1210/1215. 2. Koppla in elkablaget. Använd medlevererat pressostatkablage där så behövs. OBS! Om en scrollkompressor ska monteras i en värmepump som tidigare inte innehållit scrollkompressor, skiljer sig elinkopplingen från den tidigare kompressorn. Elinkopplingen ska då ske enligt respektive instruktioner på följande sidor. ■ Kyldelar bestyckade med scrollkompressorer har påklistrad etikett som visar att den innehåller scrollkompressor. 3. Återfyll köld- och värmebärarsystemet enligt anvisning i ”Monterings- och skötselanvisningen” avsnitt Igångkörning och injustering. ■ Värmepumpen måste ovillkorligen vara utrustad med fasföljdsvakt innan kyldelar med scrollkompressorer av storlekarna 13/15, 15/17 och 20 kW kopplas in. 4. Om en scrollkompressor monterats – utför rotationskontroll enligt avsnitt ”Rotationskontroll”. 5. Kontrollera att anslutningarna håller tätt. 6. OBS! Kondensisolera den kalla sidan (isolering som tidigare öppnats upp återställs). Demontering 1. Gör värmepumpen spänningslös innan arbetet påbörjas. 7. Återmontera luckorna. KB-f 2. Ta bort nedre sidoplåtar så att kyldelen blir åtkomlig. 3. Lyft bort frontplåten så att kablage för kompressor och pressostater blir åtkomliga. B A 4. Lossa pressostatkablage (snabbkontakter alt. rundhylsor). 5. Lossa kompressorkablaget. 76 6. Avtappning köldbärarsida: Stäng avstängningsventilerna till köldbärarsystemet. Lossa slangen mellan förångarens övre del och KB-pumpen vid förångaren (A). Den lossade slangändan kan nu böjas ner och innehållet töms i ett mindre kärl. Lossa sedan anslutningen till ”KB-f” en aning för att släppa in luft så att värmepumpens köldbärarsida helt töms. D LEK 7. Avtappning värmebärarsida: Stäng avstängningsventilerna till värmebärarsystemet. Öppna sedan avtappningsventilen (76). Lite vatten rinner ut, men för att kunna tömma hela värmebärarsidan måste kopplingen som förbinder värmebärarsidan och anslutningen på värmepumpen ”VB-fram” lossas en aning för att släppa in luft så att resterande vatten kan rinna ut. B 10. För FIGHTER 1330 se nästa sida. 11. Kyldelen kan nu dras ut. C OBS! 8. Öppna isoleringen och lossa resterande kopplingar (B). 9. Kylmodulen vilar på fyra gummidämpare. Tre är fästa i kyldelens bottenplatta (se fig) och måste lossas. Två finns på höger långsida (C) och blir åtkomliga om isoleringen öppnas lite och den tredje (D) är bakom kyldelens frontlucka. OBS! Den fjärde dämparen (längst bak till vänster) är inte fastskruvad i kyldelen och behöver ej lossas. B Elinstallationen samt eventuell service skall göras under överinseende av behörig elinstallatör. Tillbehör Art. nr. 024 531 Slangsats kyldel 4 - 8,5 kW Art. nr. 024 536 Slangsats kyldel 10 - 15 kW Art. nr. 024 542 Conexsats (FIGHTER 1310- 20, 30 kW) Conexsats Kyldelsbyte 3 SE Demontering kyldel FIGHTER 1330 Demontering kyldel FIGHTER 1330 Vit utbyte av kyldel gällande värmepump av modell FIGHTER 1330 kan det behöva skäras ut spår i plåten p g a en blindnitmutter som gör att kyldelen ej går att lyfta ur. Detta behöver bara göras om värmepumpen är tillverkad under tidsperioden 2006-11-28 till 2007-03-06 med serienummer 06501706325XXX till 06501707057XXX, 06501306339XXX till 06501307030XXX eller 06500806331XXX till 06500807030XXX. FIGHTER 1330 som är tillverkade efter den tidsperioden har redan dessa utskurna spår från fabrik. Skär ut spåren i plåten enligt bild och mått för att kunna lyfta ur kyldelen. För att ge bättre åtkomst och för att underlätta vid bearbetning av plåten kan kyldelen lyftas i framkant 10-15 mm. Den bearbetade ytan gradas och därefter målas svart. 265 185 110 80 80 K LE 11 11 30 Utskurna spår 4 Kyldelsbyte Rotationskontroll / Utbyte från kolvkompressor till scrollkompressor Rotationskontroll SE Utbyte från kolvkompressor till scrollkompressor Kompressorer av typen scroll kan endast arbeta i en rotationsriktning. Drift med fel rotationsriktning kan skada kompressorn. Allmänt Kontrollera rotationsriktningen enligt följande: Kabelsatsen gör det möjligt att ansluta en utbyteskompressor av scrolltyp till äldre värmepumpsmodeller. Rotationskontroll för kompressorer utan fasföljdsvakt För komponentplacering – se respektive Monterings- och skötselanvisning. 1. Sätt strömställare i läge 1. 2. Kontrollera att värme börjar produceras direkt efter kompressorstart genom att mäta temperaturen på hetgasledningen. Denna skall stiga med minst 5 °C inom ca 60 sek. 3. Om temperaturen förblir oförändrad är rotationsriktningen felaktig. Även ljudet är annorlunda vid fel rotationsriktning. – Sätt strömställare i läge 0 och koppla ifrån huvudströmmen. Kompressorvärmare För bästa funktion skall scrollkompressorns olja ständigt varmhållas. En kompressorvärmare är därför monterad runt kompressorns nedre del. Värmeelementet slås på så snart värmepumpen kopplas till och är i startläge. Kompressorvärmaren kopplas in enligt respektive inkopplingsschema. Fasföljd – Skifta två inkommande faser på plinten för inkommande el, -X9. Kompressorer av typen scroll kan endast arbeta i en rotationsriktning. Drift med fel rotationsriktning kan skada kompressorn. – Sätt strömställare i läge 1 och gör om rotationskontrollen. Följ anvisningarna för inkopplingen, installera eventuell fasföljdsvakt och kontrollera rotationsriktningen efter inkopp- Rotationskontroll för kompressorer med fasföljdsvakt Fasföljdsvakten känner spänningen på inkommande ledningar och förhindrar start om fasföljden inte är den rätta, eller om en fas har avbrott eller har för låg spänning. Grön lysdiod är tänd då spänning finns. Orange lysdiod är tänd vid rätt fasföljd. 1. Sätt strömställare i läge 1. 2. Är orange lysdiod på fasföljdsvakten släckt föreligger fasföljdsfel. – Sätt strömställare i läge 0 och koppla ifrån huvudströmmen. – Skifta två inkommande faser på plinten för inkommande el, -X9. – Sätt strömställare i läge 1 och gör om rotationskontrollen. Fasföljdsvakt Kyldelsbyte 5 SE Utbyte från kolvkompressor till scrollkompressor FIGHTER 1110/1115, 1210/1215 10/12 kW FIGHTER 1110/1115 13/15 & 15/17 kW Innehåll Innehåll 1 x Kylmodul med kompressorvärmare och anslutningskabel 1 x Kylmodul med kompressorvärmare och anslutningskabel Inkoppling 1 x Fasföljdsrelä (Art nr 018 903) Anslut kylmodulen enligt följande: 1 x Kabelsats (Art nr 009 436) ■ Bryt eltillförseln före arbete inuti apparaten. Allt arbete på starkströmskretsar skall utföras under överinseende av behörig elinstallatör. Till denna inkoppling används kablarna 0118, 0197, 0198 och 0199. ■ Installera kabeln till kylmodulen. Anslut kompressorvärmaren till plint (nolledare) och till kontaktorns spolanslutning (fasledare). Anslut högtryckspressostaten (gråa ledare) till plint enligt bild. Anslut kylmodul och fasföljdsrelä enligt följande: ■ Kontrollera noga att kopplingsföljden blir enligt följande: Inkoppling ■ Bryt eltillförseln före arbete inuti apparaten. Allt arbete på starkströmskretsar skall utföras under överinseende av behörig elinstallatör. ■ Installera kabeln till kylmodulen. Anslut kompressorvärmaren till plint (nolledare) och till kontaktorns spolanslutning (fasledare). Anslut högtryckspressostaten (gråa ledare) till plint enligt bild. ■ Montera fasföljdsreläet på lämplig plats. Anslut fasledarna till överströmsreläet. Kontrollera noga att kopplingsföljden blir enligt följande: Modeller med öppen eller kapslad mjukstart: Överströmsskydd Mjukstart Kompressor 2 L1-U C 4 L2-V S 6 L3-W R Modeller med öppen mjukstart: Modeller med driftkontaktor: Mjukstart Kompressor Driftkontaktor Kompressor L1 2 L1-U C 2 1–2 C L2 4 L2-V S 4 3–4 S L3 6 L3-W R 6 ■ Fasföljdsrelä Överströmsskydd Överströmsskydd 5–6 Lossa ledaren till mjukstartarens uttag A1. Klipp kabelskon och flytta kabeln till fasföljdsreläets uttag 11. Anslut den medföljande nya ledaren mellan fasföljdsreläets uttag 14 och mjukstartarens uttag A1. R Genomför rotationskontroll enligt avsnitt ”Rotationskontroll” – ”Rotationskontroll för kompressorer utan fasföljdsvakt”. Modeller med driftkontaktor: Fasföljdsrelä Överströmsskydd Driftkontaktor Kompressor L1 2 1–2 C L2 4 3–4 S L3 6 5–6 R Lossa ledaren till driftkontaktorns uttag A1. Flytta ledaren till fasföljdsreläets uttag 11. Klipp kabelskon på den medföljande nya ledaren och anslut ledaren mellan fasföljdsreläets uttag 14 och driftkontaktorns uttag A1. Modeller med kapslad mjukstart: Fasföljdsrelä Överströmsskydd Mjukstart Kompressor L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R Lossa ledaren till mjukstartarens uttag A3. Flytta den till fasföljdsreläets uttag 11. Klipp kabelskon på den medföljande nya ledaren och anslut ledaren mellan fasföljdsreläets uttag 14 och mjukstartarens uttag A3. ■ 6 Kyldelsbyte Genomför rotationskontroll enligt avsnitt ”Rotationskontroll” – ”Rotationskontroll för kompressorer med fasföljdsvakt”. Utbyte från kolvkompressor till scrollkompressor Inkopplingsschema FIGHTER 1110/1115 Bef. kabel flyttas Ny kabel (Endast för 13–17 kW) SE Fasföljdsrelä (Endast för 13–17 kW) Bef. kabel flyttas Ny kabel (Endast för 13–17 kW) SVART SVART A1 A2 GRÅ BRUN Kapslad mjukstart Extra tillbehör SVART BRUN SVART GRÅ Reläkort Driftkontaktor installerad i vissa modeller Bef. kabel flyttas Ny kabel (Endast för 13–17 kW) SVART Mjukstart öppen modell BLÅ BRUN GRÅ ALT ALT BRUN BRUN GRÅ GRÅ ALT ALT BRUN BRUN GRÅ GUL/GRÖN GRÅ SVART BRUN Anslutning till högstryckspressostat Kopplingsklämmor Kompressor Kompressorvärmare Inkopplingsschema FIGHTER 1210/1215 Kopplingsplint installerad i vissa modeller BLÅ BRUN Startkontaktor Startkontaktor Kapslad mjukstart Extra tillbehör BLÅ GRÅ ALT ALT BRUN BRUN GRÅ GRÅ ALT ALT BRUN BRUN GRÅ BRUN GRÅ GRÅ Driftkontaktor installerad i vissa modeller BRUN SVART GRÅ Mjukstart installerad i vissa modeller GUL/GRÖN GRÅ SVART BRUN GUL/GRÖN GRÅ SVART BRUN Anslutning till högstryckspressostat Kopplingsklämmor Kompressor Kompressorvärmare Kyldelsbyte 7 SE Utbyte från kolvkompressor till scrollkompressor FIGHTER 1120/1130/1220 12 kW FIGHTER 1120/1130 15–17 kW Innehåll 1 x Kylmodul med kompressorvärmare och anslutningskabel Innehåll Inkoppling 1 x Fasföljdsrelä (Art nr 018 903) Anslut kylmodulen enligt följande: 1 x Kabelsats (Art nr 009 436) Till denna inkoppling används kablarna 0118, 0197, 0198 och 0199. ■ Bryt eltillförseln före arbete inuti apparaten. Allt arbete på starkströmskretsar skall utföras under överinseende av behörig elinstallatör. ■ Installera kabeln till kylmodulen. Anslut kompressorvärmaren enligt schema för resp. modell. På vissa modeller finns en särskild anslutningsplint för kompressorvärmare. Om detta är fallet, skall denna användas. ■ ■ Kontrollera noga att kopplingsföljden blir enligt följande: Överströmsskydd Mjukstart Kompressor 2 L1-U C 4 L2-V S 6 L3-W R 1 x Kylmodul med kompressorvärmare och anslutningskabel Inkoppling Anslut kylmodulen och fasföljdsrelä enligt följande: ■ Bryt eltillförseln före arbete inuti apparaten. Allt arbete på starkströmskretsar skall utföras under överinseende av behörig elinstallatör. ■ Installera kabeln till kylmodulen. Anslut kompressorvärmaren till överströmsskyddets manöverkrets (fasledare) och till kontaktorns spolanslutning (nolledare). På vissa modeller finns en anslutningsplint (X221) för kompressorvärmare. Om detta är fallet, skall denna användas. ■ Montera fasföljdsreläet på lämplig plats. Anslut fasledarna till överströmsreläet. Kontrollera noga att kopplingsföljden blir enligt följande: Genomför rotationskontroll enligt avsnitt ”Rotationskontroll” – ”Rotationskontroll för kompressorer utan fasföljdsvakt”. Fasföljdsrelä Överströmsskydd Mjukstart Kompressor L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R Lossa ledaren till mjukstartarens uttag A1. Klipp kabelskon och flytta kabeln till fasföljdsreläets uttag 14. Anslut den medföljande nya ledaren mellan fasföljdsreläets uttag 11 och mjukstartarens uttag A1. ■ 8 Kyldelsbyte Genomför rotationskontroll enligt avsnitt ”Rotationskontroll” – ”Rotationskontroll för kompressorer med fasföljdsvakt”. Utbyte från kolvkompressor till scrollkompressor SE Inkopplingsschema FIGHTER 1120/1130 Fasföljdsrelä (Endast för 15–17 kW) A1 Bef. kabel flyttas Ny kabel A2 (Endast för 15–17 kW) 14NO SVART Vy från kontaktsida T2 6 T3 GRÅ 4 SVART T1 BRUN 2 BLÅ BRUN GUL/GRÖN Alternativ inkoppling (Plint X221 är monterad i vissa modeller) Kopplingsklämmor Kompressor Kompressorvärmare Inkopplingsschema FIGHTER 1220 Anslutningsplint Alternativ inkoppling (Plint X223 är monterad i vissa modeller) Mjukstart BLÅ BRUN GRÅ SVART BRUN Överströmsskydd GUL/GRÖN BLÅ BRUN Kopplingsklämmor Kompressor Kompressorvärmare Kyldelsbyte 9 SE Utbyte från kolvkompressor till scrollkompressor FIGHTER 1310/1320 20 kW FIGHTER 1310 25–30 kW Innehåll Innehåll 1 x Kylmodul med kompressorvärmare och anslutningskabel 1 x Kylmodul med kompressorvärmare och anslutningskabel Inkoppling 1 x Fasföljdsrelä (Art nr 018 903) Anslut kylmodulen enligt följande: 1 x Kabelsats (Art nr 009 436) ■ ■ ■ Bryt eltillförseln före arbete inuti apparaten. Allt arbete på starkströmskretsar skall utföras under överinseende av behörig elinstallatör. Inkoppling Anslut kylmodulen enligt följande: Installera kabeln till kylmodulen. Anslut kompressorvärmaren till plint (nolledare) och till kontaktorns spolanslutning alt. överströmsskyddets manöverkrets (fasledare). Anslut högtryckspressostaten (gäller Fighter 1310; gråa ledare) till plint enligt bild. Kontrollera noga att kopplingsföljden blir enligt följande: ■ Bryt eltillförseln före arbete inuti apparaten. Allt arbete på starkströmskretsar skall utföras under överinseende av behörig elinstallatör. ■ Installera kabeln till kylmodulen. Anslut kompressorvärmaren till plint (nolledare) och till kontaktorns spolanslutning (fasledare). Anslut högtryckspressostaten (gråa ledare) till plint enligt bild. ■ Montera fasföljdsreläet på lämplig plats. Anslut fasledarna till driftkontaktor B. Kontrollera noga att kopplingsföljden blir enligt följande: FIGHTER 1310: Driftkontaktor Överströmsskydd Kompressor 1 2 C 3 4 S 5 6 R FIGHTER 1320: Överströmsskydd Mjukstart Kompressor 2 L1-U C 4 L2-V S 6 L3-W R Fasföljdsrelä Driftkontaktor A DriftÖverströmskontaktor skydd B Kompressor L1 1 1 2 C L2 3 3 4 S L3 5 5 6 R Demontera kantkontakten längst till vänster på reläkortet med dess kablar och installera den medföljande kontakten enligt bild. Ta bort kabeln mellan spolanslutningarna A2 på startkontaktorn och driftkontaktor A. Installera de nya kontrolledningarna (blåa) enligt bild. ■ Genomför rotationskontroll enligt avsnitt ”Rotationskontroll” – ”Rotationskontroll för kompressorer utan fasföljdsvakt”. ■ Genomför rotationskontroll enligt avsnitt ”Rotationskontroll” – ”Rotationskontroll för kompressorer med fasföljdsvakt”. ■ Kontrollera att köldmediepumpen har rätt rotationsriktning. Om det behövs, skifta två faser i ledningen till pumpen, inte i inkommande ledning. ■ Kontrollera att köldmediepumpen har rätt rotationsriktning. Om det behövs, skifta två faser i ledningen till pumpen, inte i inkommande ledning. 10 Kyldelsbyte Utbyte från kolvkompressor till scrollkompressor SE FIGHTER 1320 25–40 kW Innehåll 1 x Kylmodul med kompressorvärmare och anslutningskabel 1 x Fasföljdsrelä (Art nr 018 903) 1 x Kabelsats (Art nr 009 436) Till denna inkoppling används kablarna 0194, 0197, 0198 och 0199. Inkoppling Anslut kylmodulen enligt följande: ■ Bryt eltillförseln före arbete inuti apparaten. Allt arbete på starkströmskretsar skall utföras under överinseende av behörig elinstallatör. ■ Installera kabeln till kylmodulen. Anslut kompressorvärmaren till plint (nolledare) och till överströmsskyddets manöverkrets (fasledare). ■ Montera fasföljdsreläet på lämplig plats. Anslut fasledarna till startkontaktor A. Kontrollera noga att kopplingsföljden blir enligt följande: Fasföljdsrelä Överströmsskydd A Mjukstart A Kompressor A L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R OBS! Om kompressor B byts är det nödvändigt att kontrollera dess inkoppling enligt följande: Kontaktor A Kontaktor B Överströmsskydd B Mjukstart B Kompressor B 1 1 2 L1-U C 3 3 4 L2-V S 5 5 6 L3-W R Klipp den blåa ledningen (035) vid kontakten på reläkortet. Lossa hela ledningen från båda mjukstartkorten och installera den omvänt enligt bild. Anslut den klippta ledningen till fasföljdsreläets uttag 11. Koppla den medföljande ledningen (0194) mellan fasföljdsreläets uttag 14 och plint X13 enligt bild ■ Genomför rotationskontroll enligt avsnitt ”Rotationskontroll” – ”Rotationskontroll för kompressorer med fasföljdsvakt”. ■ Kontrollera att köldmediepumpen har rätt rotationsriktning. Om det behövs, skifta två faser i ledningen till pumpen, inte i inkommande ledning. Kyldelsbyte 11 SE Utbyte från kolvkompressor till scrollkompressor Inkopplingsschema FIGHTER 1310 20–30 kW VIT BLÅ Kabel demonteras (Endast för 25–30 kW) Reläkort Startkontaktor Driftkontaktor Kapslad mjukstart Extra tillbehör Nytt kablage med kontakt. Kapslad mjukstart Extra tillbehör GRÅ BRUN SVART GRÅ BRUN SVART Befintligt kablage demonteras. (Endast för 25–30 kW) GRÅ BRUN BRUN SVART GRÅ SVART Fasföljdsrelä GUL/GRÖN GUL/GRÖN (Endast för 25–30 kW) GRÅ BRUN GRÅ ALT ALT BRUN GRÅ BRUN GRÅ ALT ALT BRUN BRUN BLÅ GRÅ BRUN GRÅ ALT ALT BRUN GRÅ BRUN GRÅ ALT ALT BRUN BRUN BLÅ Anslutning till högstryckspressostat Kopplingsklämmor Kompressor B Kompressorvärmare Anslutning till högstryckspressostat Kompressor A Kompressorvärmare Kopplingsklämmor 12 Kyldelsbyte Utbyte från kolvkompressor till scrollkompressor SE Inkopplingsschema FIGHTER 1320 20–40 kW Mjukstart Klipp kabel 035 (Endast för 25–40 kW) Reläkort Anslut den klippta kabeln GRÅ GUL/GRÖN BRUN SVART GRÅ GUL/GRÖN BRUN SVART (Endast för 25–40 kW) Fasföljdsrelä (Endast för 25–40 kW) Startkontaktor A Startkontaktor B BLÅ BRUN Kompressor B Kompressorvärmare Kopplingsklämmor BLÅ BRUN Kopplingsklämmor Kompressor A Kompressorvärmare Kyldelsbyte 13 SERVICE INSTRUCTION Cooling section replacement ground source heat pumps General Accessories Instructions for cooling section replacement regarding NIBE ground source heat pumps. Part no. 024 531 Hose kit cooling section 4 – 8.5 kW ■ When replacing the cooling section, a hose kit (see Accessories) may also be required if the heat pump is manufactured before 31-01-2004 (serial number XXXXXX04030XXX), cooling sections made after this date have standard conex connections. ■ Together with the cooling section, new pressostat wiring (low pressure/operation) is supplied, which, if necessary, is to be used for FIGHTER 1110/1115 and FIGHTER 1210/1215. ■ Cooling sections equipped with scroll compressors have an attached label that indicates that it contains a scroll compressor. ■ The heat pump must, in all circumstances, be equipped with a phase sequence monitor before cooling sections with 13/15, 15/17 and 20 kW scroll compressors are connected. 14 Part no. 024 536 Hose kit cooling section 10 – 15 kW Part no. 024 542 Conex kit (FIGHTER 1310- 20, 30 kW) Conex kit Cooling section replacement GB General Dismantling Re-assembly 1. Cut the power to the heat pump before starting work. 1. Re-assemble the replacement cooling section in reverse order. 2. Remove the lower side panels to access the cooling section. 3. Remove the front panel to access the wiring for the compressor and pressostats. 4. Disconnect the pressostat wiring (quick-release connectors or round sleeves). 5. Disconnect the compressor wiring. 6. Draining, collector side: Close the shut-off valves for the brine system. Disconnect the hose between the top of the evaporator and the brine pump on the evaporator (A). The loose hose end can now be bent down and emptied in a small bowl. Now loosen the connection on “Brine-out” a little to allow air to enter so the heat pump's collector side is emptied completely. 7. Draining, heat medium side: Close the shut-off valves in heating medium system. Now open the drain valve (76). A small amount of water runs out, however, to fully empty the heating medium side requires the connector that joins the heating medium side and the connection on the heat pump “VB-flow” to be loosened a little to allow air to enter so the remaining water can run out. 2. Connect the power cable. Use the supplied pressostat wiring where required. Note! If a scroll compressor is to be installed in a heat pump that did not previously contain a scroll compressor, the electrical connection differs from the earlier compressor. The electrical connection should then be carried out according to the relevant instructions on the following pages. 3. Refill the brine and heating medium system according to the instructions in ”Installation and Maintenance instructions” section Commissioning and adjustment. 4. If a scroll compressor is installed – carry out a rotation check according to section ”Rotation check”. 5. Check that the connections are secure. 6. Note! Insulate the cold side from condensation (restore any open insulation). 7. Refit the covers. KB-f B A 8. Open the insulation and disconnect the remaining connections (B). 10. For FIGHTER 1330 see the following page. 76 D B LEK 9. The cooling module rests on four rubber dampers. Three are fixed in the base panel of the cooling section (see fig) and must be disconnected. There are two on the long right-hand side (C) and can be accessed by opening the insulation slightly and the third (D) is behind the front panel of the cooling section. Note! The fourth damper (rearmost to the left) is not fixed in the cooling section and does not need to be disconnected. B C 11. The cooling section can now be pulled out. Note! Electrical installation and service must be carried out under the supervision of a qualified electrician. Cooling section replacement 15 GB Removing the cooling section from FIGHTER 1330 Removing the cooling section from FIGHTER 1330 When replacing the cooling section for the heat pump on FIGHTER 1330, grooves may need to be cut in the panel due to a blind rivet that prevents the cooling section from being removed. This only need be carried out if the heat pump was manufactured between 2006-11-28 and 2007-03-06 with serial numbers 06501706325XXX to 06501707057XXX, 06501306339XXX to 06501307030XXX or 06500806331XXX to 06500807030XXX. FIGHTER 1330 models manufactured after this time already have these grooves. Cut grooves in the panel with measurements as illustrated to be able to lift out the cooling section. To obtain better access and to facilitate work on the panel, the cooling section can be lifted 10-15 mm at its front edge. Grind and paint the affected surface black afterwards. 265 185 110 80 11 80 11 30 Cut-out grooves 16 Cooling section replacement K LE Rotation check / Replacing piston compressor for scroll compressor Rotation check Scroll type compressors can only operate in one direction of rotation. Operating in the wrong direction can damage the compressor. GB Replacing piston compressor for scroll compressor General Check the direction of rotation as follows: The cable kit makes it possible to connect a replacement compressor of the scroll type to older heat pump models. Rotation check for compressors without phase sequence monitor Refer to relevant "Installation and Maintenance Instructions" for location of components. 1. Set the switch to 1. 2. Check for heat production immediately after the compressor starts by measuring the temperature on the hot gas line. It must rise by at least 5°C within 60 seconds. 3. If the temperature remains the same, the direction of rotation is incorrect. The noise produced is also different when rotating in the incorrect direction. – Set the switch to 0 and cut the main power supply. – Swap the two incoming phases on the terminal block for incoming electricity, -X9. – Set the switch to 1 and check the rotation again. Rotation check for compressors with phase sequence monitor The phase sequence monitor senses the voltage on incoming wiring and prevents start-up if the phase sequence is not correct, or if a phase has an open-circuit or has insufficient voltage. Compressor heater For optimum function the scroll compressor oil must be continuously warmed. A compressor heater is therefore mounted in the lower part of the compressor. The heating element comes on as soon as the heat pump is switched on and is in the start position. The compressor heater is connected according to the relevant connection diagram. Phase sequence Scroll type compressors can only operate in one direction of rotation. Operating in the wrong direction can damage the compressor. Follow the connection instructions, install any phase sequence monitors and check the rotation direction after connection to ensure that the phase sequence is correct. Green LED is lit when there is power. Orange LED is lit at correct phase sequence. 1. Set the switch to 1. 2. if the orange LED on the phase sequence monitor is not lit there is a phase sequence fault. – Set the switch to 0 and Disconnect the main power supply. – Swap the two incoming phases on the terminal block for incoming electricity, -X9. – Set the switch to 1 and check the rotation again. Phase sequence monitor Cooling section replacement 17 GB Replacing piston compressor for scroll compressor FIGHTER 1110/1115, 1210/1215 10/12 kW compressor heater to terminal block (neutral conductor) and to the contactor’s spool connection (phase conductor). Connect the high-pressure pressostat (grey cable) to terminal block as illustrated. Contents 1 x Cooling module with compressor heater and connection cable ■ Connection Connect the cooling module as follows: ■ ■ ■ Disconnect the power supply before working inside the unit. All work on high current circuits must be carried out under the supervision of an authorised electrician. Models with open soft-starter: Install the cable to the cooling module. Connect the compressor heater to terminal block (neutral conductor) and to the contactor’s spool connection (phase conductor). Connect the high-pressure pressostat (grey cable) to terminal block as illustrated. Models with open or enclosed soft-starter: Soft-starter Compressor 2 L1-U C 4 L2-V S 6 L3-W R Overcurrent protection device Softstarter Compressor L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R Models with operating contactor: Models with operating contactor: ■ Phase sequence relay Disconnect the conductor to the soft-starter socket A1. Cut the cable clip and move the cable to phase sequence relay socket 11. Connect the supplied new conductor between phase sequence relay socket 14 and soft-starter socket A1. Thoroughly check that the connection sequence is as follows: Overcurrent protection device Install the phase sequence relay in a suitable location. Connect the phase conductors to the overcurrent relay. Thoroughly check that the connection sequence is as follows: Overcurrent protection device Operating contactor Compressor 2 1–2 C 4 3–4 S 6 5–6 R Phase sequence relay Overcurrent protection device Operating contactor Compressor L1 2 1–2 C L2 4 3–4 S L3 6 5–6 R Disconnect the conductor for the operating contactor socket A1. Transfer the conductor to phase sequence relay socket 11. Cut the cable clip on the supplied new conductor and connect the conductor between phase sequence relay socket 14 and operating contactor socket A1. Carry out rotation check according to section ”Rotation check” – ”Rotation check for compressors without phase sequence monitor”. Models with enclosed soft-starter: Phase sequence relay Overcurrent protection device Softstarter Compressor FIGHTER 1110/1115 13/15 & 15/17 kW L1 2 L1-U C Contents L2 4 L2-V S L3 6 L3-W R 1 x Cooling module with compressor heater and connection cable Disconnect the conductor for the soft-starter socket A3. Transfer it to phase sequence relay socket 11. Cut the cable clip on the supplied new conductor and connect the conductor between phase sequence relay socket 14 and soft-starter socket A3. 1 x Phase sequence relay (Part no. 018 903) 1 x Cable kit (Part no. 009 436) Cables 0118, 0197, 0198 and 0199 are used for this connection. Connection Connect the cooling module and phase sequence relay as follows: ■ Disconnect the power supply before working inside the unit. All work on high current circuits must be carried out under the supervision of an authorised electrician. ■ Install the cable to the cooling module. Connect the 18 ■ Carry out rotation check according to section ”Rotation check” – ”Rotation check for compressors with phase sequence monitor”. Cooling section replacement Replacing piston compressor for scroll compressor Connection diagram FIGHTER 1110/1115 Existing cable moved New cable (Only for 13-17 kW) GB Phase sequence relay (Only for 13-17 kW) Existing cable moved New cable (Only for 13-17 kW) BLACK BLACK A1 A2 GREY BLACK Enclosed soft-starter Extra accessories BROWN BROWN BLACK GREY Relay card Operating contactor installed in certain models Existing cable moved New cable (Only for 13-17 kW) BLACK Soft-starter open model BLUE BROWN GRÅOR ALT BRUN GREY BROWN GRÅOR ALT BRUN GREY BROWN GREY BLACK BROWN YELLOW/GREEN Connection to high-pressure pressostat Connection clamps Compressor Compressor heater Connection diagram FIGHTER 1210/1215 Terminal block installed in certain models BLUE BROWN Starter contactor Starter contactor Enclosed softstarter Extra accessories BLUE GRÅ ALT GREY OR BRUN BROWN GRÅ ALT GREY OR BRUN BROWN BROWN GREY GREY Operating contactor installed in certain models BROWN BLACK GREY Soft-starter installed in certain models YELLOW/GREEN GREY BLACK BROWN YELLOW/GREEN GREY BLACK BROWN Connection to high-pressure pressostat Connection clamps Compressor Compressor heater Cooling section replacement 19 GB Replacing piston compressor for scroll compressor FIGHTER 1120/1130/1220 12 kW FIGHTER 1120/1130 15–17 kW Contents 1 x Cooling module with compressor heater and connection cable Contents Connection 1 x Phase sequence relay (Part no. 018 903) Connect the cooling module as follows: 1 x Cable kit (Part no. 009 436) Cables 0118, 0197, 0198 and 0199 are used for this connection. ■ ■ ■ ■ Disconnect the power supply before working inside the unit. All work on high current circuits must be carried out under the supervision of an authorised electrician. Install the cable to the cooling module. Connect the compressor heater according to the diagram for the relevant model. On certain models there is a special terminal block for compressor heaters. Use the terminal block if this is the case. Thoroughly check that the connection sequence is as follows: Overcurrent protection device Soft-starter Compressor 2 L1-U C 4 L2-V S 6 L3-W R 1 x Cooling module with compressor heater and connection cable Connection Connect the cooling module and phase sequence relay as follows: ■ Disconnect the power supply before working inside the unit. All work on high current circuits must be carried out under the supervision of an authorised electrician. ■ Install the cable to the cooling module. Connect the compressor heater to the overcurrent protection control circuit (phase conductors) and to the contactor’s spool connection (neutral conductor). On certain models, there is a terminal block (X221) for compressor heaters. Use the terminal block if this is the case. ■ Install the phase sequence relay in a suitable location. Connect the phase conductors to the overcurrent relay. Thoroughly check that the connection sequence is as follows: Carry out rotation check according to section ”Rotation check” – ”Rotation check for compressors without phase sequence monitor”. Phase sequence relay Overcurrent protection device Softstarter Compressor L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R Disconnect the conductor to the soft-starter socket A1. Cut the cable clip and move the cable to phase sequence relay socket 14. Connect the supplied new conductor between phase sequence relay socket 11 and soft-starter socket A1. ■ 20 Carry out rotation check according to section ”Rotation check” – ”Rotation check for compressors with phase sequence monitor”. Cooling section replacement Replacing piston compressor for scroll compressor GB Connection diagram FIGHTER 1120/1130 Phase sequence relay (Only for 15–17 kW) A1 Existing cable moved New cable A2 (Only for 15–17 kW) 14NO BLACK View from contact side 4 T2 6 T3 BLACK GREY T1 BROWN 2 BLUE BROWN YELLOW/GREEN Alternative connection (Terminal block X221 is installed in certain models) Connection clamps Compressor Compressor heater Connection diagram FIGHTER 1220 Terminal block Alternative connection (Terminal block X223 is installed in certain models) Soft-starter BLUE BROWN GREY BLACK BROWN YELLOW/GREEN Overcurrent protection device BLUE BROWN Connection clamps Compressor Compressor heater Cooling section replacement 21 GB Replacing piston compressor for scroll compressor FIGHTER 1310/1320 20 kW FIGHTER 1310 25–30 kW Contents Contents 1 x Cooling module with compressor heater and connection cable 1 x Cooling module with compressor heater and connection cable Connection 1 x Phase sequence relay (Part no. 018 903) Connect the cooling module as follows: 1 x Cable kit (Part no. 009 436) ■ ■ ■ Cut the power supply before working inside the unit. All work on high current circuits must be carried out under the supervision of an authorised electrician. Install the cable to the cooling module. Connect the compressor heater to terminal block (neutral conductor) and to the contactor’s spool connection or overcurrent protection control circuit (phase conductor). Connect the high-pressure pressostat (applies to Fighter 1310; grey cable) to terminal block as illustrated. Thoroughly check that the connection sequence is as follows: Connection Connect the cooling module as follows: ■ Disconnect the power supply before working inside the unit. All work on high current circuits must be carried out under the supervision of an authorised electrician. ■ Install the cable to the cooling module. Connect the compressor heater to terminal block (neutral conductor) and to the contactor’s spool connection (phase conductor). Connect the high-pressure pressostat (grey cable) to terminal block as illustrated. ■ Install the phase sequence relay in a suitable location. Connect the phase conductors to operating contactor B. Thoroughly check that the connection sequence is as follows: FIGHTER 1310: Operating contactor Overcurrent protection device Compressor 1 2 C 3 4 S 5 6 R FIGHTER 1320: Overcurrent protection device Soft-starter 2 L1-U Compressor L2-V S 6 L3-W R ■ Carry out rotation check according to section ”Rotation check” – ”Rotation check for compressors without phase sequence monitor”. ■ Check that the brine pump rotates in the correct direction. If required, swap two phases in the cable to the pump, not in incoming cable. 22 Operating contactor A Operating contactor, B Overcurrent protection device Compressor L1 1 1 2 C L2 3 3 4 S L3 5 5 6 R Remove the edge contactor at the far left on the relay card with its cables and install the supplied contactor as illustrated. Remove the cable between the spool connections A2 on the start contactor and operating contactor A. Install the new control wiring (blue) as illustrated. C 4 Phase sequence relay ■ Carry out rotation check according to section ”Rotation check” – ”Rotation check for compressors with phase sequence monitor”. ■ Check that the brine pump rotates in the correct direction. If required, swap two phases in the cable to the pump, not incoming cable. Cooling section replacement Replacing piston compressor for scroll compressor GB FIGHTER 1320 25–40 kW Contents 1 x Cooling module with compressor heater and connection cable 1 x Phase sequence relay (Part no. 018 903) 1 x Cable kit (Part no. 009 436) Cables 0194, 0197, 0198 and 0199 are used for this connection. Connection Connect the cooling module as follows: ■ Disconnect the power supply before working inside the unit. All work on high current circuits must be carried out under the supervision of an authorised electrician. ■ Install the cable to the cooling module. Connect the compressor heater to terminal block (neutral conductor) and to the overcurrent protection control circuit (phase conductor). ■ Install the phase sequence relay in a suitable location. Connect the phase conductors to the start contactor A. Thoroughly check that the connection sequence is as follows: Phase sequence relay Overcurrent protection A Soft-starter A Compressor A L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R Note! If compressor B is replaced, it is necessary to check its connection as follows: Contactor A Contactor B Overcurrent protection B Softstarter B Compressor B 1 1 2 L1-U C 3 3 4 L2-V S 5 5 6 L3-W R Cut the blue cable (035) at the contactor on the relay card. Disconnect the entire cable from both the softstarter card and install in reverse order as illustrated. Connect the cut cable to phase sequence relay socket 11. Connect the supplied cable (0194) between phase sequence relay socket 14 and terminal block X13 as illustrated ■ Carry out rotation check according to section ”Rotation check” – ”Rotation check for compressors with phase sequence monitor”. ■ Check that the brine pump rotates in the correct direction. If required, swap two phases in the cable to the pump, not incoming cable. Cooling section replacement 23 GB Replacing piston compressor for scroll compressor Connection diagram FIGHTER 1310 20–30 kW WHITE BLUE Cable removed (Only for 25-30 kW) Relay card Starter contactor Operating contactor Enclosed soft-starter Extra accessories New wiring with contact. Enclosed soft-starter Extra accessories GREY (Only for 25-30 kW) GREY BLACK Phase sequence relay (Only for 25-30 kW) YELLOW/GREEN YELLOW/GREEN BROWN BLACK GREY BROWN BLACK BROWN GREY BLACK BROWN Existing wiring removed. GRÅ ALT BRUN GREY OR BROWN GRÅ OR ALTBROWN BRUN GREY BROWN BLUE GRÅ OR ALTBROWN BRUN GREY GRÅ BRUN GREY ALT OR BROWN BROWN BLUE Connection to high-pressure pressostat Connection clamps Compressor B Compressor heater Connection to high-pressure pressostat Compressor A Compressor heater Connection clamps 24 Cooling section replacement Replacing piston compressor for scroll compressor GB Connection diagram FIGHTER 1320 20–40 kW Soft-starter Cut cable 035 (Only for 25-40 kW) Relay card Connect the cut cable GREY YELLOW/GREEN BLACK BROWN GREY YELLOW/GREEN BLACK BROWN (Only for 25-40 kW) Phase sequence relay (Only for 25-40 kW) Start contactor A Start contactor B BLUE BROWN Compressor B Compressor heater Connection clamps BLUE BROWN Connection clamps Compressor A Compressor heater Cooling section replacement 25 SERVICE-INSTRUKTION Kühlteilwechsel Sole/Wasser - Wärmepumpen Allgemeines Zubehör Anleitung zum Kühlteilwechsel in NIBESolewasserwärmepumpen. Art.nr. 024 531 Schlauchsatz Kühlteil 4-8,5 kW Art.nr. 024 536 Schlauchsatz Kühlteil 10-15 kW Art.nr. 024 542 Conex-Satz Conex-Satz (FIGHTER 1310- 20, 30 kW) ■ Bei einem Kühlteilwechsel kann ein Schlauchsatz (siehe Zubehör) erforderlich sein, wenn die Wärmepumpe vor dem 31.01.2004 hergestellt wurde (siehe Seriennummer XXXXXX04030XXX). Kühlteile, die nach diesem Datum hergestellt wurden, verfügen standardmäßig über Conex-Anschlüsse. ■ Im Lieferumfang des Kühlteils befinden sich neue Pressostatkabel (Niederdruck/Betrieb), die bei Bedarf für FIGHTER 1110/1115 und FIGHTER 1210/1215 zu verwenden sind. ■ Mit Scrollverdichtern bestückte Kühlteile sind mit einem Etikett versehen, das auf diese Ausstattung hinweist. ■ Die Wärmepumpe muss unbedingt mit einem Phasenfolgenwächter ausgerüstet werden, bevor Kühlteile mit Scrollverdichtern der Leistungsgrößen 13/15, 15/17 und 20 kW angeschlossen werden dürfen. 26 Kühlteilwechsel DE Allgemeines Demontage Erneute Montage 1. Unterbrechen Sie vor Beginn der Arbeiten die Spannungszufuhr zur Wärmepumpe. 1. Die erneute Montage des Wechselkühlteils geschieht in umgekehrter Reihenfolge. 2. Nehmen Sie die unteren Seitenverkleidungen am, um an den Kühlteil zu gelangen. 2. Schließen Sie die Stromkabel an. Nutzen Sie bei Bedarf die beiliegenden Pressostatkabel. Hinweis: Wenn in einer Wärmepumpe erstmals ein Scrollverdichter montiert werden soll, ist der elektrische Anschluss im Gegensatz zum vorherigen Verdichter anders auszuführen. Der elektrische Anschluss muss in diesem Fall gemäß den Vorgaben auf den folgenden Seiten vorgenommen werden. 3. Heben Sie die Frontverkleidung ab, um die Kabel für Verdichter und Pressostate freizulegen. 4. Lösen Sie die Pressostatkabel (Schnellanschlüsse bzw. Buchsen). 5. Lösen Sie die Verdichterkabel. 6. Entleerung Kälteträgerseite: Schließen Sie die Absperrventile für das Kälteträgersystem. Lösen Sie den Schlauch zwischen dem oberen Verdampferteil und der Kälteträgerpumpe am Verdampfer (A). Das gelöste Schlauchende kann nach unten gebogen und der Schlauchinhalt in ein kleines Gefäß gefüllt werden. Lösen Sie anschließend die Verbindung mit ”KB-f” ein wenig, um Luft einzulassen und die Kälteträgerseite der Wärmepumpe komplett zu entleeren. 7. Entleerung Wärmeträgerseite: Schließen Sie die Absperrventile für das Wärmeträgersystem. Öffnen Sie anschließend das Entleerungsventil (76). Nun fließt etwas Wasser ab. Um die gesamte Wärmeträgerseite entleeren zu können, muss die Verbindung zwischen Wärmeträgerseite und dem Wärmepumpeanschluss ”VB-fram” leicht gelöst werden, um Luft zuzuführen und so das verbleibende Wasser abzulassen. 3. Befüllen Sie erneut das Kälte- und Wärmeträgersystem anhand der Anleitung im Abschnitt Inbetriebnahme und Einstellung in der ”Montage- und Wartungsanleitung”. 4. Wurde ein Scrollverdichter montiert, führen Sie eine Rotationskontrolle aus (siehe gleichnamiger Abschnitt). 5. Kontrollieren Sie, ob die Anschlüsse dicht sind. 6. Hinweis: Isolieren Sie die kalte Seite gegen Kondensation. (Stellen Sie dabei die zuvor geöffnete Isolierung wieder her.) 7. Bringen Sie die Abdeckungen wieder an. KB-f B A 8. Öffnen Sie die Isolierung und lösen Sie die restlichen Verbindungen (B). 76 D B LEK 9. Das Kühlmodul ruht auf vier Gummidämpfern. Drei sind an der Bodenplatte des Kühlteils befestigt (siehe Abbildung) und müssen gelöst werden. Zwei Gummidämpfer befinden sich an der rechten Längsseite (C) und sind erreichbar, wenn die Isolierung ein Stück geöffnet wird und sich der dritte Gummidämpfer (D) hinter der Frontabdeckung des Kühlteils befindet. Hinweis: Der vierte Dämpfer (ganz hinten links) ist nicht am Kühlteil festgeschraubt und muss nicht gelöst werden. B 10. Angaben zu FIGHTER 1330 finden Sie auf der nächsten Seite. C 11. Der Kühlteil kann nun herausgezogen werden. Hinweis: Die Elektroinstallation sowie eventuelle Wartungsarbeiten müssen unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. Kühlteilwechsel 27 DE Demontering kyldel FIGHTER 1330 Kühlteildemontage an FIGHTER 1330 Beim Kühlteilwechsel an Wärmepumpenmodell FIGHTER 1330 müssen evtl. Nuten im Blech angebracht werden, da eine Blindnietenmutter das Herausheben des Kühlteils verhindert. Dieser Arbeitsschritt ist nur erforderlich, wenn die Wärmepumpe im Zeitraum 28.11.2006 bis 06.03.2007 hergestellt wurde und eine Seriennummer im Bereich 06501706325XXX bis 06501707057XXX, 06501306339XXX bis 06501307030XXX oder 06500806331XXX bis 06500807030XXX liegt. FIGHTER 1320/1330-Modelle, die nach dem o.g. Zeitraum gefertigt wurden, sind bereits werkseitig mit Nuten versehen. Stellen Sie die Nuten im Blech gemäß den Abmessungen auf der Abbildung her, um den Kühlteil herausheben zu können. Um eine einfachere Erreichbarkeit und Bearbeitung des Blechs zu ermöglichen, kann der Kühlteil an der Vorderseite um 10-15 cm angehoben werden. Entgraten Sie die bearbeitete Fläche und streichen Sie sie mit schwarzer Farbe. 265 185 110 80 11 80 11 30 Nuten 28 Kühlteilwechsel K LE Rotationskontrolle / Umrüstung von Kolben- zu Scrollverdichter Rotationskontrolle Scrollverdichter können nur mit einer Rotationsrichtung betrieben werden. Bei einer falschen Rotationsrichtung kann der Verdichter beschädigt werden. Kontrollieren Sie die Rotationsrichtung wie folgt: DE Umrüstung von Kolben- zu Scrollverdichter Allgemeines Mithilfe des Kabelsatzes lassen sich ältere Wärmepumpenmodelle mit einem Scrollverdichter aufrüsten. Rotationskontrolle für Verdichter ohne Phasenfolgenwächter Hinweise zur Position der Komponenten entnehmen Sie der entsprechenden Montage- und Wartungsanleitung. 1. Bringen Sie den Betriebsschalter in Stellung 1. 2. Kontrollieren Sie, ob direkt nach dem Verdichterstart Wärme erzeugt wird, indem Sie die Temperatur an der Heißgasleitung messen. Die Temperatur muss innerhalb von ca. 60 s um mindestens 5°C steigen. 3. Ändert sich die Temperatur nicht, liegt eine falsche Rotationsrichtung vor. Eine falsche Rotationsrichtung ist ebenfalls an der Geräuschentwicklung erkennbar. Verdichtererwärmer Für eine optimale Funktionsweise muss das Öl des Scrollverdichters ständig warmgehalten werden. Daher ist um den unteren Verdichterteil ein Verdichtererwärmer montiert. Das Heizelement wird aktiviert, sobald die Wärmepumpe eingeschaltet wird und sich im Startmodus befindet. – Bringen Sie den Betriebsschalter in Stellung 0 und trennen Sie die Netzstromversorgung. Der Verdichtererwärmer wird gemäß dem entsprechenden Schaltschema eingebunden. – Vertauschen Sie zwei Eingangsphasen an der Klemme für die Stromversorgung -X9. Phasenfolge – Bringen Sie den Betriebsschalter in Stellung 1 und überprüfen Sie die Rotationsrichtung erneut. Scrollverdichter können nur mit einer Rotationsrichtung betrieben werden. Bei einer falschen Rotationsrichtung kann der Verdichter beschädigt werden. Rotationskontrolle für Verdichter mit Phasenfolgenwächter Der Phasenfolgenwächter misst die Spannung der Eingangsleitungen und verhindert einen Start, wenn die Phasenfolge nicht korrekt ist, eine Phase unterbrochen ist oder eine zu niedrige Spannung aufweist. Befolgen Sie die Anschlussanweisungen, installieren Sie einen eventuellen Phasenfolgenwächter und kontrollieren Sie nach der Montage, ob eine korrekte Rotationsrichtung vorliegt. Die grüne LED leuchtet, wenn eine Spannung anliegt. Die orangefarbene LED leuchtet bei korrekter Phasenfolge. 1. Bringen Sie den Betriebsschalter in Stellung 1. 2. Wenn die orangefarbene LED am Phasenfolgenwächter nicht leuchtet, liegt ein Phasenfolgenfehler vor. – Bringen Sie den Betriebsschalter in Stellung 0 und trennen Sie die Netzstromversorgung. – Vertauschen Sie zwei Eingangsphasen an der Klemme für die Stromversorgung -X9. – Bringen Sie den Betriebsschalter in Stellung 1 und überprüfen Sie die Rotationsrichtung erneut. Phasenfolgenwächter Kühlteilwechsel 29 DE Umrüstung von Kolben- zu Scrollverdichter FIGHTER 1110/1115, 1210/1215 für 10/12 kW ■ Inhalt 1 Kühlmodul mit Verdichtererwärmer und Anschlusskabel Anschluss Modelle mit offenem Schonstart: Schließen Sie das Kühlmodul wie folgt an: ■ Montieren Sie das Phasenfolgenrelais an einer geeigneten Position. Verbinden Sie die Phasenleiter mit dem Überstromrelais. Kontrollieren Sie genau, ob diese Schaltfolge vorliegt: Unterbrechen Sie vor der Ausführung der Arbeiten die Stromzufuhr im Gerät. Sämtliche Arbeiten an Starkstromkreisen müssen unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. Phasenfolgenrelais Überstromschutz Schontstart Verdichter L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R ■ Installieren Sie das Kabel zum Kühlmodul. Verbinden Sie den Verdichtererwärmer mit der Klemme „Nullleiter“ und dem Spulenanschluss des Schützes (Phasenleiter). Verbinden Sie den Hochdruckpressostat (graue Drähte) wie auf der Abbildung mit der Klemmleiste. ■ Kontrollieren Sie genau, ob diese Schaltfolge vorliegt: Lösen Sie den Draht am Schonstartrelais „A1“. Entfernen Sie den Kabelschuh und setzen Sie das Kabel zu Anschluss „11“ am Phasenfolgenrelais um. Verbinden Sie Anschluss „14“ am Phasenfolgenrelais und Anschluss „A1“ am Schonstart mit dem beiliegenden neuen Draht. Modelle mit offenem oder gekapseltem Schonstart: Modelle mit Betriebsschütz: Überstromschutz Schonstart Verdichter L1-U C Phasenfolgenrelais Überstromschutz Betriebsschütz Verdichter 2 4 L2-V S L1 2 1–2 C R L2 4 3–4 S L3 6 5–6 R 6 L3-W Modelle mit Betriebsschütz: ■ Überstromschutz Betriebsschütz Verdichter 2 1–2 C 4 3–4 S 6 5–6 R Lösen Sie den Draht am Betriebsschützanschluss „A1“. Setzen Sie den Draht zu Anschluss „11“ am Phasenfolgenrelais um. Entfernen Sie den Kabelschuh vom beiliegenden neuen Draht. Verbinden Sie Anschluss „14“ am Phasenfolgenrelais und Anschluss „A1“ am Betriebsschütz mit dem neuen Draht. Modelle mit gekapseltem Schonstart: Führen Sie eine Rotationskontrolle gemäß dem Abschnitt ”Rotationskontrolle” – ”Rotationskontrolle für Verdichter ohne Phasenfolgenwächter” aus. FIGHTER 1110/1115 für 13/15 und 15/17 kW 1 Kühlmodul mit Verdichtererwärmer und Anschlusskabel 1 x Phasenfolgenrelais (Art.nr. 018 903) 1 x Kabelsatz (Art.nr. 009 436) Anschluss Schließen Sie Kühlmodul und Phasenfolgenrelais wie folgt an: ■ Unterbrechen Sie vor der Ausführung der Arbeiten die Stromzufuhr im Gerät. Sämtliche Arbeiten an Starkstromkreisen müssen unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. ■ Installieren Sie das Kabel zum Kühlmodul. Verbinden Sie den Verdichtererwärmer mit der Klemme „Nullleiter“ und dem Spulenanschluss des Schützes (Phasenleiter). Verbinden Sie den Hochdruckpressostat (graue Drähte) wie auf der Abbildung mit der Klemmleiste. 30 Überstromschutz Schontstart Verdichter L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R Lösen Sie den Draht am Schonstartrelais „A3“. Setzen Sie den Draht zu Anschluss „11“ am Phasenfolgenrelais um. Entfernen Sie den Kabelschuh vom beiliegenden neuen Draht. Verbinden Sie Anschluss „14“ am Phasenfolgenrelais und Anschluss „A3“ am Schontstart mit dem neuen Draht. Inhalt Für diesen Anschluss werden die Kabel 0118, 0197, 0198 und 0199 genutzt. Phasenfolgenrelais ■ Führen Sie eine Rotationskontrolle gemäß dem Abschnitt ”Rotationskontrolle” – ”Rotationskontrolle für Verdichter mit Phasenfolgenwächter” aus. Kühlteilwechsel Umrüstung von Kolben- zu Scrollverdichter Schaltschema FIGHTER 1110/1115 Phasenfolgenrelais (nur für 13-17 kW) Vorh. Kabel wird umgesetzt Vorh. Kabel wird umgesetzt Neues Kabel Neues Kabel (nur für 13-17 kW) DE (nur für 13-17 kW) SCHWARZ SCHWARZ A1 A2 GRAU BRAUN Gekapselter Schonstart Extrazubehör SCHWARZ BRAUN SCHWARZ GRAU Relaiskarte Betriebsschütz bei bestimmten Modellen installiert Vorh. Kabel wird umgesetzt Neues Kabel (nur für 13-17 kW) SCHWARZ Modell mit offenem Schonstart BLAU BRAUN GRÅBZW. ALT BRAUN BRUN GRAU ALTBRAUN BRUN GRAUGRÅ BZW. GRAU SCHWARZ BRAUN GELB/GRÜN Anschluss am Hochdruckpressostat Anschlussklemmen Verdichter Verdichtererwärmer Schaltschema FIGHTER 1210/1215 Anschlussklemme bei bestimmten Modellen installiert BLAU BRAUN Startschütz Startschütz Gekapselter Schonstart Extrazubehör BLAU GRÅ ALT GRAU BZW.BRUN BRAUN GRÅ ALT GRAU BZW.BRUN BRAUN BRAUN GRAU GRAU Betriebsschütz bei bestimmten Modellen installiert BRAUN SCHWARZ GRAU Schonstart bei bestimmten Modellen installiert GELB/GRÜN GRAU SCHWARZ BRAUN GELB/GRÜN GRAU SCHWARZ BRAUN Anschluss am Hochdruckpressostat Anschlussklemmen Verdichter Verdichtererwärmer Kühlteilwechsel 31 DE Umrüstung von Kolben- zu Scrollverdichter FIGHTER 1120/1130/1220 für 12 kW FIGHTER 1120/1130 für 15-17 kW Inhalt 1 Kühlmodul mit Verdichtererwärmer und Anschlusskabel Inhalt Anschluss 1 x Phasenfolgenrelais (Art.nr. 018 903) Schließen Sie das Kühlmodul wie folgt an: 1 x Kabelsatz (Art.nr. 009 436) ■ ■ ■ ■ Unterbrechen Sie vor der Ausführung der Arbeiten die Stromzufuhr im Gerät. Sämtliche Arbeiten an Starkstromkreisen müssen unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. Installieren Sie das Kabel zum Kühlmodul. Schließen Sie den Verdichtererwärmer gemäß dem Schema für das jeweilige Modell an. Bestimmte Modelle besitzen eine spezielle Anschlussklemme für Verdichtererwärmer. Ist dies der Fall, sollte sie genutzt werden. 1 Kühlmodul mit Verdichtererwärmer und Anschlusskabel Für diesen Anschluss werden die Kabel 0118, 0197, 0198 und 0199 genutzt. Anschluss Schließen Sie Kühlmodul und Phasenfolgenrelais wie folgt an: ■ Unterbrechen Sie vor der Ausführung der Arbeiten die Stromzufuhr im Gerät. Sämtliche Arbeiten an Starkstromkreisen müssen unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. ■ Installieren Sie das Kabel zum Kühlmodul. Verbinden Sie den Verdichtererwärmer mit dem Steuerkreis für den Überstromschutz (Phasenleiter) und dem Spulenanschluss des Schützes (Nullleiter). Bestimmte Modelle besitzen eine Anschlussklemme (X221) für Verdichtererwärmer. Ist dies der Fall, sollte sie genutzt werden. ■ Montieren Sie das Phasenfolgenrelais an einer geeigneten Position. Verbinden Sie die Phasenleiter mit dem Überstromrelais. Kontrollieren Sie genau, ob diese Schaltfolge vorliegt: Kontrollieren Sie genau, ob diese Schaltfolge vorliegt: Überstromschutz Schontstart Verdichter 2 L1-U C 4 L2-V S 6 L3-W R Führen Sie eine Rotationskontrolle gemäß dem Abschnitt ”Rotationskontrolle” – ”Rotationskontrolle für Verdichter ohne Phasenfolgenwächter” aus. Phasenfolgenrelais Überstromschutz Schontstart Verdichter L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R Lösen Sie den Draht am Schonstartrelais „A1“. Entfernen Sie den Kabelschuh und setzen Sie das Kabel zu Anschluss „14“ am Phasenfolgenrelais um. Verbinden Sie Anschluss „11“ am Phasenfolgenrelais und Anschluss „A1“ am Schontstart mit dem beiliegenden neuen Draht. ■ 32 Führen Sie eine Rotationskontrolle gemäß dem Abschnitt ”Rotationskontrolle” – ”Rotationskontrolle für Verdichter mit Phasenfolgenwächter” aus. Kühlteilwechsel Umrüstung von Kolben- zu Scrollverdichter DE Schaltschema FIGHTER 1120/1130 Phasenfolgenrelais (nur für 15-17 kW) A1 Vorh. Kabel wird umgesetzt Neues Kabel A2 (nur für 15-17 kW) 14NO SCHWARZ Ansicht von der Anschlussseite T2 6 T3 GRAU 4 SCHWARZ T1 BRAUN 2 BLAU BRAUN GELB/GRÜN Alternativer Anschluss (Klemme X221 ist an bestimmten Modellen montiert.) Anschlussklemmen Verdichter Verdichtererwärmer Schaltschema FIGHTER 1220 Anschlussklemme Alternativer Anschluss (Klemme X223 ist an bestimmten Modellen montiert.) Schontstart GRAU BRAUN BLAU BRAUN BLAU GELB/GRÜN SCHWARZ Überstromschutz BRAUN Anschlussklemmen Verdichter Verdichtererwärmer Kühlteilwechsel 33 DE Umrüstung von Kolben- zu Scrollverdichter FIGHTER 1310/1320 für 20 kW FIGHTER 1310 für 25-30 kW Inhalt Inhalt 1 Kühlmodul mit Verdichtererwärmer und Anschlusskabel 1 Kühlmodul mit Verdichtererwärmer und Anschlusskabel Anschluss 1 x Phasenfolgenrelais (Art.nr. 018 903) Schließen Sie das Kühlmodul wie folgt an: 1 x Kabelsatz (Art.nr. 009 436) ■ ■ ■ Unterbrechen Sie vor der Ausführung der Arbeiten die Stromzufuhr im Gerät. Sämtliche Arbeiten an Starkstromkreisen müssen unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. Installieren Sie das Kabel zum Kühlmodul. Verbinden Sie den Verdichtererwärmer mit der Klemme „Nullleiter“ und dem Spulenanschluss des Schützes bzw. dem Steuerkreis für den Überstromschutz (Phasenleiter). Verbinden Sie den Hochdruckpressostat (gilt für Fighter 1310; graue Drähte) wie auf der Abbildung mit der Klemmleiste. Kontrollieren Sie genau, ob diese Schaltfolge vorliegt: Anschluss Schließen Sie das Kühlmodul wie folgt an: ■ Unterbrechen Sie vor der Ausführung der Arbeiten die Stromzufuhr im Gerät. Sämtliche Arbeiten an Starkstromkreisen müssen unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. ■ Installieren Sie das Kabel zum Kühlmodul. Verbinden Sie den Verdichtererwärmer mit der Klemme „Nullleiter“ und dem Spulenanschluss des Schützes (Phasenleiter). Verbinden Sie den Hochdruckpressostat (graue Drähte) wie auf der Abbildung mit der Klemmleiste. ■ Montieren Sie das Phasenfolgenrelais an einer geeigneten Position. Verbinden Sie die Phasenleiter mit Betriebsschütz B. Kontrollieren Sie genau, ob diese Schaltfolge vorliegt: FIGHTER 1310: Betriebsschütz Überstromschutz Verdichter 1 2 C 3 4 S 5 6 R FIGHTER 1320: Überstromschutz Schontstart Verdichter 2 L1-U C 4 L2-V S 6 L3-W R ■ Führen Sie eine Rotationskontrolle gemäß dem Abschnitt ”Rotationskontrolle” – ”Rotationskontrolle für Verdichter ohne Phasenfolgenwächter” aus. ■ Kontrollieren Sie, ob die Kälteträgerpumpe die korrekte Rotationsrichtung aufweist. Vertauschen Sie bei Bedarf zwei Phasen in der Leitung zur Pumpe, jedoch nicht in der Eingangsleitung. 34 Phasenfolgenrelais Betriebsschütz A Betriebsschütz B Überstromschutz Verdichter L1 1 1 2 C L2 3 3 4 S L3 5 5 6 R Demontieren Sie den Randkontakt samt Kabel ganz links an der Relaiskarte und bringen Sie den beiliegenden Stecker an (siehe Abbildung). Entfernen Sie das Kabel zwischen den Spulenanschlüssen A2 an Start- und Betriebsschütz A. Bringen Sie die neuen Kontrollleitungen (blau) gemäß Abbildung an. ■ Führen Sie eine Rotationskontrolle gemäß dem Abschnitt ”Rotationskontrolle” – ”Rotationskontrolle für Verdichter mit Phasenfolgenwächter” aus. ■ Kontrollieren Sie, ob die Kälteträgerpumpe die korrekte Rotationsrichtung aufweist. Vertauschen Sie bei Bedarf zwei Phasen in der Leitung zur Pumpe, jedoch nicht in der Eingangsleitung. Kühlteilwechsel Umrüstung von Kolben- zu Scrollverdichter DE FIGHTER 1320 für 25-40 kW Inhalt 1 Kühlmodul mit Verdichtererwärmer und Anschlusskabel 1 x Phasenfolgenrelais (Art.nr. 018 903) 1 x Kabelsatz (Art.nr. 009 436) Für diesen Anschluss werden die Kabel 0194, 0197, 0198 und 0199 genutzt. Anschluss Schließen Sie das Kühlmodul wie folgt an: ■ Unterbrechen Sie vor der Ausführung der Arbeiten die Stromzufuhr im Gerät. Sämtliche Arbeiten an Starkstromkreisen müssen unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. ■ Installieren Sie das Kabel zum Kühlmodul. Verbinden Sie den Verdichtererwärmer mit der Klemme „Nullleiter“ und dem Steuerkreis für den Überstromschutz (Phasenleiter). ■ Montieren Sie das Phasenfolgenrelais an einer geeigneten Position. Verbinden Sie die Phasenleiter mit Startschütz A. Kontrollieren Sie genau, ob diese Schaltfolge vorliegt: Phasenfolgenrelais Überstromschutz A Schontstart A Verdichter A L1 2 L1-U C L2 4 L2-V S L3 6 L3-W R Hinweis: Bei einem Wechsel von Verdichter B muss dessen Anschluss wie folgt kontrolliert werden: Schütz A Schütz B Überstromschutz B Schontstart B Verdichter B 1 1 2 L1-U C 3 3 4 L2-V S 5 5 6 L3-W R Durchtrennen Sie die blaue Leitung (035) am Anschluss an der Relaiskarte. Nehmen Sie die gesamte Leitung von beiden Schontstartkarten ab und bringen Sie sie umgekehrt wieder an (siehe Abbildung). Verbinden Sie die abgetrennte Leitung mit Anschluss „11“ am Phasenfolgenrelais. Verbinden Sie Anschluss „14“ am Phasenfolgenrelais und Klemme X13 laut Abbildung mit der beiliegenden Leitung (0194). ■ Führen Sie eine Rotationskontrolle gemäß dem Abschnitt ”Rotationskontrolle” – ”Rotationskontrolle für Verdichter mit Phasenfolgenwächter” aus. ■ Kontrollieren Sie, ob die Kälteträgerpumpe die korrekte Rotationsrichtung aufweist. Vertauschen Sie bei Bedarf zwei Phasen in der Leitung zur Pumpe, jedoch nicht in der Eingangsleitung. Kühlteilwechsel 35 DE Umrüstung von Kolben- zu Scrollverdichter Schaltschema FIGHTER 1310 für 20-30 kW WEISS BLAU Kabel demontieren (nur für 25-30 kW) Relaiskarte Startschütz Betriebsschütz Gekapselter Schontstart Extrazubehör GRAU (nur für 25-30 kW) Phasenfolgenrelais GRAU BRAUN SCHWARZ BRAUN SCHWARZ GRAU Vorhandenes Kabel demontieren. BRAUN SCHWARZ GRAU BRAUN SCHWARZ Neues Kabel mit Stecker. Gekapselter Schontstart Extrazubehör GELB/GRÜN GELB/GRÜN (nur für 25-30 kW) GRÅBZW. ALTBRAUN BRUN GRAU GRÅBZW. ALTBRAUN BRUN GRAU BRAUN BLAU GRÅBZW. ALTBRAUN BRUN GRAU GRÅ BRUN GRAU ALT BZW. BRAUN BRAUN BLAU Anschluss am Hochdruckpressostat Anschlussklemmen Verdichter B Verdichtererwärmer Anschluss am Hochdruckpressostat Verdichter A Verdichtererwärmer Anschlussklemmen 36 Kühlteilwechsel Umrüstung von Kolben- zu Scrollverdichter DE Schaltschema FIGHTER 1320 für 20-40 kW Schontstart Kabel 035 durchtrennen (nur für 25-40 kW) Relaiskarte Durchtrenntes Kabel anschließen GRAU GELB/GRÜN BRAUN SCHWARZ GRAU GELB/GRÜN BRAUN SCHWARZ (nur für 25-40 kW) Phasenfolgenrelais (nur für 25-40 kW) Startschütz A Startschütz B BLAU BRAUN Verdichter B Verdichtererwärmer Anschlussklemmen BLAU BRAUN Anschlussklemmen Verdichter A Verdichtererwärmer Kühlteilwechsel 37 38 CZ DE DK FI GB NL NO PL NIBE CZ, V Zavetri 1478/6, CZ-170 00 Prague 7 Tel: 0266 791 796 Fax: 0266 791 796 E-mail: [email protected] www.nibe.com NIBE Systemtechnik GmbH, Am Reiherpfahl 3, D-29223 Celle Tel: 05141/7546-0 Fax: 05141/7546-99 E-mail: [email protected] www.nibe.de Vølund Varmeteknik, Filial af NIBE AB, Brogårdsvej 7, 6920 Videbæk Tel: 97 17 20 33 Fax: 97 17 29 33 E-mail: [email protected] www.volundvt.dk NIBE – Haato, Valimotie 27, 01510 Vantaa Puh: 09-274 697 0 Fax: 09-274 697 40 E-mail: [email protected] www.haato.fi NIBE Energy Systems Ltd Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: [email protected] www.nibe.co.uk NIBE Energietechniek B.V. Postbus 2 4797 ZG WILLEMSTAD NB Tel: 0168 477722 Fax: 0168 476998 E-mail: [email protected] www.nibenl.nl NIBE AB, Jerikoveien 20, 1067 Oslo Tel: 22 90 66 00 Fax: 22 90 66 09 E-mail: [email protected] www.nibe-villavarme.no NIBE-BIAWAR Sp. z o. o. Aleja Jana Pawła II 57, 15-703 BIAŁYSTOK Tel: 085 662 84 90 Fax: 085 662 84 14 E-mail: [email protected] www.biawar.com.pl NIBE AB Sweden, Box 14, Järnvägsgatan 40, SE-285 21 Markaryd Tel: +46-(0)433-73 000 Fax: +46-(0)433-73 190 E-mail: [email protected] www.nibe.com