Typ: KTBSB

Transcrição

Typ: KTBSB
Typ: KTBSB-112.070
Art.-No.: MA200202
Features:
Klimaregler mechanisch mit neutraler Zone, AP, 5...30°C, für 4-Rohrsysteme, Wechsler, 230VAC,
6(3)A, Schalter Ventilator 3-stufig, Schalter "EIN/AUS", reinweiß ähnlich RAL 9010
Application:
Control and monitoring of temperatures in closed, dry spaces. Remote control of air conditioners,
climate chests, fan coil systems in living and office spaces and doctors’ practices. Individual room
optimisation in central air conditioning systems (hotels, hospitals etc.).
Suitable for all heating systems. (Please note the maximum switching current)
Technical Data:
Dimensions of housing:
Dimensions of packaging:
Number of outputs:
Number, control range:
Output signal:
Output signal:
External setting:
Configuration:
Rated impulse voltage:
Operating voltage:
Design:
On Off:
setting range to:
110 x 26 x 110,7 mm
115 x 45 x 115 mm
7
1
Heizen, schaltend (230 VAC, 50 Hz)
Kühlen, schaltend (230 VAC, 50 Hz)
yes
Einzelraumklimaregler mit neutraler Zone für 4-Rohrsysteme, 3stufiger Lüfterausgang, 2x Hilfsausgang "Ein/Aus"
4000 V
230 VAC, 50 Hz
Berlin 3000
yes
30
setting range from:
Electrical connection:
Fancoil:
Colour of housing:
Sensor:
Weight:
Output, heating:
Hysteresis:
Output, cooling:
Storage temperature:
Air distribution systems:
Material of housing:
max. switching voltage:
max. switching current:
mechanical range setting:
min. switching voltage:
Installation/fastening:
Neutral zone:
Surface quality:
potential-free:
Control range up to:
Control range from:
Control function:
Switching element:
ON/OFF switch:
3-stage fan switch:
Switching contact:
Switching power:
Degree of protection:
Protection class:
Safety and EMC:
Scale - degrees Celsius:
Set point adjuster:
Part Air Conditioning:
Thermal feedback:
Ambient temperature up to:
Ambient temperature from:
Degree of fouling:
other/similar items:
Accessories:
5
Schraubklemmen
yes
reinweiß, ähnlich RAL 9010
Bimetall
ca. 170 g
yes
Heizen ca. 1 K, Kühlen ca. 2 K, bei einer Temperaturänderung von
max. 4 K / h
yes
-20...+70 °C
yes
Kunststoff ABS
230 VAC, 50 Hz
6 (3) A
yes
230 VAC, 50 Hz
Aufputz- / Wandmontage oder mittels Adapterplatte auf UP-Dose
ca. 2 K
matt
no
30
5
Heizen und Kühlen
Bimetallkontakt
yes
yes
Wechsler
1380 W
IP 30
II, nach entsprechender Montage
gemäß DIN EN 60730
yes
yes
yes
yes
30
0
2
weitere Regler mit Ausgängen für Heizen / Kühlen finden Sie unter
Heiztechnik (RTBSB/FTR)
Klemmenleisten: VOORL passende Ventilstellantriebe: ZBOOA010.100 Adapterplatte zur Montage auf UP-Dose: JZ-17
Permissible atmospheric
humidity:
Ciruit Diagram:
max. 95% r. H., nicht kondensierend