New coating system for upgrading sewer structures
Transcrição
New coating system for upgrading sewer structures
1 Products New coating system for upgrading sewer structures Neues Beschichtungssystem für die Ertüchtigung von Abwasserbauwerken Die Autoren 1 The structural maintenance of sewer structures ensures their processing functionality and thus significantly contributes to the protection of the environment and waterways. For the current (fourth) generation of wastewater treatment systems in Germany, DIN 1045: 2001-06 imposes considerably higher requirements on serviceability. The current technical regulations for sewer structures state a normative service life of 50 to 80 years; for special structures with increased exposure Juniorprofessorin Dr.-Ing. Dipl.-Chem. Andrea Dimmig- 25 to 40 years. Osburg (1958), Studium der Verfahrenschemie an der Technischen Universität Merseburg, 1982 wissenschaftliche Assistentin am Lehrstuhl Technische Chemie der Friedrich-Schiller-Universität Jena, 1989 Verfahrenstechnologin in der Forschung des Kombinates Mikroelektronik in Erfurt, 1990–1991 Leitung des Labors für Forschungund Entwicklung der Epowit Bautechnik GmbH in Weimar (zuvor Industrie- und Spezialbau des BMK Erfurt), 1991–2003 wissenschaftliche Mitarbeiterin am F.A. FingerInstitut für Baustoffkunde der Bauhaus-Universität Weimar, seit August 2003 Juniorprofessorin für Polymere Bindemittel und Baustoffe im Bauwesen am F.A. Finger-Institut für Baustoffkunde der BauhausUniversität Weimar. Dr. Wolfram Kämpfer (1954), Studium Baustoffverfahrenstechnik an der HAB Weimar, leitet die Arbeitsgruppe Materialbeständigkeit an der MFPA Weimar. Arbeitsschwerpunkte sind derzeit die Klärung von Schadensursachen und Schadensmechanismen in Anlagen der Wasserversorgung und der Abwasserentsorgung sowie Umweltsimulationsprüfungen an Bau- und Werkstoffen. 52 Sewer systems are subject to high mechanical-abrasive, chemical, biochemical and microbiological aggressive load and are therefore subject to significantly higher wear than comparable civil engineering structures. The current maintenance expenditure (absolute) for Germany is estimated at 45 billion Euro [1]. Container structures in sewer systems are generally made of reinforced concrete. Owing to the extreme loads and the severe biochemical-corrosive wear to which they are exposed, special structures (pumping stations, storage basins, preconcentration basins, digestion towers, sewage sludge basins) rarely reach the intended service life of 25 years. In particular, the combination of direct chemical attack by wastewaters and the biogenically formed acid in the condensate leads to actions to which concretes defined in DIN 1045:2001-06 have no sufficient resistance. In these structures, the limit values given in DWA M 168 and DIN 4030 are cyclically or continually exceeded. The consequences are leaching and softening in the edge zone of concrete, followed by layer-bylayer erosion. For concrete exposed to highly aggressive media, DIN 1045:2001-06 requires active protective measures, as neither the selection of specific cements and additions nor an increase in the concrete cover would ensure sufficient durability. From practice, damage cases are known where the service life lasted only five to ten years, despite interior coatings provided in the form of thin and/or thick polymer-modified mineral coatings or synthetic resin. Surface erosion due to biogenic acid attack sets in with hydrogen sulfide contents as low as ≥ 0.5 ppm and increases progressively with higher concentrations. If pH values of 3.5 are achieved above the water-change zone in the condensate of the free inner surface, a corrosion rate of 0.5 to 0.8 mm per annum can be expected. 1 Die bautechnische Instandhaltung von Abwasserbauwerken gewährleistet die verfahrenstechnische Funktionsfähigkeit und leistet damit einen wesentlichen Beitrag zum Umwelt- und Gewässerschutz. Für die derzeitig vierte Generation von Kläranlagen in der Bundesrepublik Deutschland werden nach DIN 1045: 2001-06 deutlich erhöhte Anforderungen an die Gebrauchstauglichkeit gestellt. Die normative Nutzungsdauer von Abwasserbauwerken wird nach den bestehenden technischen Regeln mit 50 bis 80 Jahren angegeben, für Sonderbauwerke bei erhöhter Exposition mit 25 bis 40 Jahren. Abwasseranlagen unterliegen durch starke mechanisch-abrassive, chemische, biochemische und mikrobiologische Angriffe einer deutlich höheren Abnutzung als vergleichbare Ingenieurbauwerke. Der aktuelle Instandsetzungsaufwand (absolut) wird für die Bundesrepublik Deutschland auf etwa 45 Mrd. Euro geschätzt [1]. Behälterkonstruktionen in Abwasseranlagen sind in der Regel aus Stahlbeton gefertigt. Durch extreme Beanspruchungen und biochemisch-korrosiven Verschleiß wird in den Sonderbauwerken (Pumpwerke, Speicherbecken, Voreindicker, Faultürme, Klärschlammbecken) die angestrebte Nutzungsdauer von 25 Jahren zumeist nicht erreicht. Insbesondere die Kombination aus direktem chemischem Angriff durch Abwässer und dem biogen gebildeten saueren Angriff im Kondensat führt zu Beanspruchungen, bei denen Betone nach DIN 1045:2001-06 keine ausreichende Beständigkeit aufweisen. Die Grenzwerte nach DWA M 168 und DIN 4030 werden in derartigen Bauwerken zyklisch oder dauerhaft überschritten. In deren Folge kommt es zu Auslaugungen und Entfestigungen in der Betonrandzone und nachfolgend zum schichtenweisen Abtrag. Bei sehr stark betonangreifenden Medien werden nach DIN 1045:2001-06 aktive Schutzmaßnahmen gefordert, da weder die Auswahl bestimmter Zemente und Zusatzstoffe noch die Erhöhung der Betonüberdeckung eine ausreichende Dauerhaftigkeit gewährleisten. Aus der Praxis sind Schadensfälle bekannt, bei denen die Nutzungsdauer trotz Innenbeschichtungen mittels kunststoffmodifizierter mineralischer Dünnbzw. Dickbeschichtungen oder Kunstharzen nur fünf bis zehn Jahre betrug. BFT 12/2006 Produkte 1 An erosion rate of 1.2 to 1.8 mm per annum can be reached at pH value of 2. For a pH value of 0, an erosion rate of up to 3.0 mm per annum can be assumed. The extent of the damage depends on the emission rate, which is determined by the temperature, the container geometry and the inlet and outlet conditions, as well as the aeration conditions [2]. General maintenance requirements for sewer structures Maintenance is understood to mean the conservation of value by means of structural measures. The structures undergoing maintenance must generally be shut down for a limited period of time. However, since the structures are firmly anchored in a technological process, rehabilitation concepts are drawn up under boundary conditions with shutdown times as brief as possible. Primary decision criteria in choosing rehabilitation methods are econo-technical aspects. A distinction is made between repair measures carried out in locally restricted areas of a structure and the renovation of large-scale structural components, as well as of the entire structure. The repair operations contain locally restricted injection and sealing measures. Coating and lining methods are part of renovation programs. Decisive factors that influence the choice of rehabilitation process are, aside from the economic assessment and the remaining service life, the amounts of time required for preparing the ground, rehabilitation and hardening. Shutting down generally involves considerable interference with the technological process, which – under the aspects of water protection engineering – is only possible for a restricted period of time. When choosing the appropriate materials for highly stressed sewer structures, the loads imposed and the materials’ properties must be matched. This refers to the mechanical and chemical loads and the impacts of climate change. For processes not yet covered by a technical standard, technical approvals or test results must be presented. The coating processes are subject to the technical regulations of the ZTV-ING code of practice and the rehabilitation guidelines of the German Committee for Reinforced Concrete (DAfStb). Synthetic resin coatings represent an essential basic principle of rehabilitation. Here, the bond behavior is of critical significance; in particular as in most cases this involves structural components in which moisture has penetrated from the backside. The experiences gained so far in various demonstration projects show that damages occurred even where all of the boundary conditions, such as the condition of the concrete base, residual moisture and quality of execution, had been observed. The formation of blisters and detachments (osmosis) are typical damage symptoms. When processing reactive resins the use of solventless, totally unsaponifiable coating systems with low moisture-induced swelling is recommended. In planning coating measures, the minimal and the maximal coating thicknesses, the target coating thickness, BFT 12/2006 Der Oberflächenabtrag infolge biogenen Säureangriffs beginnt bereits bei Hydrogensulfidanteilen ≥ 0,5 ppm und nimmt bei höheren Konzentrationen progressiv zu. Werden im Kondensat der freien Innenfläche oberhalb der Wasserwechselzone pH-Werte von 3,5 erreicht, kann mit einer Korrosionsgeschwindigkeit von 0,5 bis 0,8 mm pro Jahr gerechnet werden. Bei einem pH-Wert von 2 erreicht die Abtragsgeschwindigkeit 1,2 bis 1,8 mm pro Jahr. Für einen pH-Wert von 0 kann von einem Abtrag bis zu 3,0 mm pro Jahr ausgegangen werden. Die Schädigung hängt von den Emisionsmengen ab, die durch die Temperatur, die Behältergeometrie, die Ein- und Auslaufbedingungen sowie die Belüftungsverhältnisse bestimmt werden [2]. Generelle Anforderungen an die Instandhaltung von Abwasserbauwerken Unter Instandhaltung wird die bautechnische Werterhaltung verstanden. In der Regel sind die Bauwerke für Instandhaltungsmaßnahmen befristet außer Betrieb zu nehmen. Da diese jedoch in einem technologischen Ablauf fest verankert sind, werden Sanierungskonzepte unter den Randbedingungen einer möglichst kurzen Außerbetriebnahme erarbeitet. Wesentliche Entscheidungskriterien für die Auswahl von Sanierungsverfahren sind betriebswirtschaftlich-technische Gesichtspunkte. Es wird in Reparaturmaßnahmen örtlich begrenzter Bauteilbereiche und Renovierung großflächiger Bauteile sowie des gesamten Bauwerkes unterschieden. Die Reparaturverfahren beinhalten örtlich begrenzte Injektions- und Abdichtungsmaßnahmen. Bestandteil der Renovierung sind Beschichtungs- und Auskleidungsverfahren. Entscheidenden Einfluss auf die Auswahl von Sanierungsverfahren haben neben der betriebswirtschaftlichen Beurteilung und der Restnutzungsdauer, die Dauer von Untergrundvorbereitung, Sanierung und Aushärtung. Die Außerbetriebnahme stellt in der Regel einen erheblichen Eingriff in den technologischen Ablauf dar, der unter gewässerschutztechnischen Gesichtspunkten zeitlich nur begrenzt möglich ist. Bei der Auswahl geeigneter Werkstoffe für hochbeanspruchte Abwasserbauwerke sind die Beanspruchungen und die Werkstoffeigenschaften aufeinander abzustimmen. Dies betrifft die mechanischen Belastungen, die chemischen Beanspruchungen sowie die Klimawechselbelastungen. Für Verfahren, die noch nicht durch ein technisches Regelwerk erfasst sind, müssen bauaufsichtliche Zulassungen oder Prüfbescheide vorgelegt werden. Für Beschichtungsverfahren gelten die technischen Regeln der ZTV-ING und der Instandsetzungsrichtlinie des DAfStb. Kunstharzbeschichtungen stellen ein wesentliches Grundprinzip der Instandsetzung dar. Dem Verbundverhalten kommt hierbei eine entscheidende Bedeutung zu, insbesondere da es sich zumeist um rückwärtig durchfeuchtete Bauteile handelt. Die Erfahrungen, die bereits durch verschiedene Demonstrationsprojekte gesammelt wurden, zeigen, Dipl.-Ing. Patrick Beck (1972); Studium des Bauingenieurwesens in der Fachrichtung Baustoffe und Sanierung an der Bauhaus-Universität Weimar; Freier Mitarbeiter für verschiedene Ingenieurbüros mit Tätigkeitsschwerpunkt Betonsanierung und Bauwerkserhaltung; seit 2006 am Institut für Materialforschung und -prüfung GmbH Nordhausen, Tätigkeitsschwerpunkte: Betoninstandsetzung, Baustoffprüfung, Materialanalytik. 53 1 Products dass selbst bei Einhaltung aller Randbedingungen wie Beschaffenheit der Betonunterlage, Restfeuchte und Ausführungsqualität Schäden auftraten. Blasenbildungen und Ablösungen (Osmose) sind typische Schadensbilder. Bei Reaktionsharzen wird empfohlen, lösungsmittelfreie, vollständig unverseifbare Beschichtungssysteme mit geringer Feuchtequellung zu verwenden. Bei der Planung von Beschichtungsmaßnahmen sind die minimalen sowie maximalen Schichtdicken, die Sollschichtdicke, die Art der Untergrundvorbehandlung sowie der technologische Ablauf festzulegen. Es empfiehlt sich, zunächst durch Materialprüfungen und Anlegen von Musterflächen die Eignung des Verfahrens festzustellen und ggf. eine Optimierung der Zusammensetzung vorzunehmen. Fig. 1 Basis reaction for polyurea systems. Abb. 1 Basisreaktion für Polyurea-Systeme. Applikation eines neuen Beschichtungssystems in einem Modellprojekt the manner of substrate preparation and the technological procedure must be determined. In order to determine the suitability of a system it is recommended first to carry out materials tests and to prepare sample surfaces and optimize them if required. Application of a new coating system in a model project Within the framework of a model project, a large-scale investigative program on the application of a new coating system on the basis of Polyurea spray elastomer was conducted. The application program was accompanied Tensile strength 18 … 25 N/mm2 Zugfestigkeit Yield 250 … 430% Dehnung Temperature stability –20°C …+150°C Temperaturbeständigkeit Adhesive tensile strength Haftzugfestigkeit – on steel 8… 10 N/mm2 auf Stahl – on cast iron 6… 8 N/mm2 auf Gusseisen – on concrete C 30/37 auf Beton C 30/37 • dry without primer 3… 5 N/mm2 trocken ohne Primer • dry with primer 4… 5 N/mm2 trocken mit Primer • wet without primer 2… 4 N/mm2 nass ohne Primer • wet with primer 3…. 5 N/mm2 nass mit Primer Processing temperature –15°C … +40°C Verarbeitungstemperatur Load capability/trafficable by foot after 4 hours Belastbarkeit/Begehbarkeit nach 4 Stunden Table 1 Overview of the technical properties of polyrea spray elastomers. Tabelle 1 Übersicht zu technischen Eigenschaften von PolyureaSprühelastomeren. 54 Im Rahmen eines Modellvorhabens wurde ein umfangreiches Untersuchungsprogramm zur Applikation eines neuen Beschichtungssystems auf der Basis eines Polyurea-Sprühelastomers durchgeführt. Das Applikationsprogramm wurde durch verschiedene Labortests wissenschaftlich begleitet. Den Schwerpunkt der Untersuchungen bildete die Charakterisierung des Haftverbundes in Abhängigkeit von der Untergrundvorbehandlung sowie die Bewertung der Beschichtungen nach Klimawechsel- und Medienbeanspruchungen (Wasser und 10%ige Schwefelsäure) in Zeitraffertests. Es wurden zwei modifizierte Polyurea-Systeme auf unterschiedlich vorbereitete Wandflächen eines Faulbehälters (Baujahr 1982) sowie für Labortests auf werksmäßig hergestellten Betonplatten C 30/37 aufgebracht. Insgesamt wurden zwölf Beschichtungsvarianten in Vor-Ort-Applikationen und 24 Varianten für die Labortests realisiert. Bei Polyurea handelt es sich um ein Elastomer, das durch chemische Reaktion zwischen Isocyanaten und Aminen entsteht (Abb. 1): » Komponente A: Aliphatische oder Aromatische Isocyanate » Komponente B: Polyesteramine, Kettenverlängerer und Additive. Derzeitige industrielle Hauptanwendungen dieser Systeme liegen in den Bereichen Chemieanlagenbau und Fördertechnik, wo entsprechend hohe Anforderungen sowohl an chemische, als auch Temperatur- und Abrasionsbeständigkeit – verbunden mit sehr kurzfristigen Ausführungszeiten – bestehen. Die Produktentwicklung wurde in den letzten Jahren maßgeblich in Nordamerika vorangetrieben. Polyurea-Beschichtungen weisen eine weitgehende Feuchteunempfindlichkeit auf, dasheißt, die Applikation kann auch auf feuchte Betonuntergründe erfolgen. Sie sind durch kurzeVerarbeitungs- und Aushärtungszeiten gekennzeichnet (Gelzeiten: 3 bis 6 s, Klebzeiten < 30 s, Aushärtezeiten < 6 h). Dies bedeutet, dass frisch beschichtete Flächen in einem Zeitraum von weniger als 4 Stunden wieder voll beaufschlagt werden können. Weiterhin sind sie relativ unempfindlich gegenüber BFT 12/2006 1 Products by various further on-going laboratory tests. The investigations focused on the characterization of the bond, depending on the preparation of the substrate and the assessment of the coating following exposure to the loads of climate change and media (water and 10% sulfuric acid) in accelerated tests. Two modified polyurea systems were applied to the differently prepared wall surfaces of a digestion tank (built in 1982) as well as to concrete slabs C 30/37 manufactured under factory conditions. A total of twelve coating variants were realized on location and 24 variants in the laboratory tests. Polyurea is an elastomer formed through chemical reaction between isocyanates and amines (Fig. 1): » Component A: aliphatic or aromatic isocyanates » Component B: polyesteramines, chain extenders and additives. The principal applications for these systems currently lie in the areas of chemical plant construction and materials handling technology, where correspondingly high requirements are placed both on the chemical resistance and the resistance to temperature abrasion – in conjunction with very short execution times. Product development in recent years has been promoted particularly in North America. Polyurea coatings are largely insensitive to moisture, i.e. the coatings can also be applied to moist concrete substrates. They are characterized by short processing and hardening times (gel times: 3 to 6 s, bonding times < 30 s, hardening times < 6 h). This means that freshly coated surfaces can be fully functional within a period of less than 4 hours. In addition, they are relatively insensitive to low temperatures and higher air humidity. Application is possible at temperatures as low as –15 °C and relative humidities of up to 90% [3]. The complete conversion to a solid guarantees no VOC emission. Layer thicknesses from 1 to 6 mm are possible. The coatings can be adjusted to have specific material properties suited to special applications. Poly- tiefen Temperaturen und erhöhter Luftfeuchtigkeit. Die Applikation ist bei Temperaturen bis zu –15 °C sowie bei relativen Luftfeuchtigkeiten bis zu 90 % möglich [3]. Die vollständige Feststoffumsetzung garantiert keine VOC-Emision. Es sind Schichtdicken von 1 bis 6 mm möglich. Für spezielle Anwendungen können spezifische Materialeigenschaften eingestellt werden. Großtechnisch erprobt wurden Polyurea-Beschichtungen auf Stahl, Gusseisen und GFK-Werkstoffen. Die Qualität der Beschichtung wird wesentlich durch die Misch- und Spritztechnologie beeinflusst (Systemdruck, Mischungsverhältnis). Langzeiterfahrungen für Beschichtungen auf feuchten Betonoberflächen liegen derzeit nicht vor. Die Tabelle 1 zeigt einige mechanisch-technische Kennwerte von PolyureaSystemen [4, 5, 6]. Die Anwendung von Sprühelastomeren stellt erhöhte Anforderungen an: » die personaltechnische (Qualifizierung/Erfahrung) und gerätetechnische Ausstattung des ausführenden Unternehmens sowie » die materialtechnische Anpassung an spezifische Applikationsbedingungen (Systemaufbau, Produktauswahl). Grundsätzlich werden für die Betonunterlage Mindestdruckfestigkeiten ≥ C 20/25 und Rissbreiten ≤ 0,5 mm gefordert. Zudem ist die Betonunterlage nach Maßgabe der ZTV-ING und der Richtlinie DAfStb-SIB vorzubereiten [7]. In diesem Versuchsprogramm wurden weitere Vorbereitungsverfahren einbezogen. Zwei speziell für die Anwendung in Abwasserbauwerken modifizierte Polyurea-Beschichtungen mit den Bezeichnungen RPS-B und RPS-R wurden auf die unterschiedlich vorbereiteten Betonunterlagen auf der Innenwand eines Faulbehälter aufgesprüht (Abb. 2 bis Abb. 5). Als Untergrundvorbehandlung kamen zum Einsatz: » Trockeneisstrahlen mit CO2 (CO) Produkte 1 urea coatings were proven in full-scale tests on steel, cast iron and GRP materials. The quality of the coating is significantly influenced by the mixing and spraying technology used (system pressure, mix ratio). Longterm experiences with systems on coatings applied to moist concrete surfaces are not yet available. The Table 1 lists a number of mechanical-technical parameters for polyurea-systems [4, 5, 6]. The application of spray elastomers places higher demands on: » the technical expertise of the personnel (qualification/experience) and the technical equipment available to the company executing the job as well as » the adjustment of the materials technology to the specific application conditions (system configuration, product choice). Basically, the concrete substrates that are to receive the coating must have a minimum compressive strength of ≥ C 20/25 and crack widths ≤ 0.5 mm. Moreover, the concrete substrate must be prepared in accordance with the requirements specified in ZTV-ING and the DAfStb-SIB code of practice [7]. In this experimental program additional preparatory methods were included. Two polyurea coatings, designated RPS-B and RPS-R and especially modified for application in sewer structures, were sprayed onto differently prepared concrete substrates on the inside wall of a digestion tank (Fig. 2 to Fig. 5). Substrates prepared by the following methods were used: » Dry ice blasting with CO2 (CO) » High-pressure water jet (HDS) » Sand/shotblasting (FS). The concrete wall areas were adjusted to defined concrete moistures. The application of both systems (RPS-B, RPS-R) was executed with and/or without primer in each case; the primer was rolled on. In par- Fig. 2 General overview of the interior walls of a digestion tank made of precast components with differently prepared wall areas. Abb. 2 Gesamtübersicht Faulbehälterinnenwände aus Betonfertigteilen mit unterschiedlich vorbereiteten Wandflächen. Fig. 3 Preparation of substrate using high-pressure water jet. Abb. 3 Untergrundvorbehandlung mittels HDS. » Hochdruckwasserstrahlen (HDS) » Feststoffstrahlen (FS). Auf den Betonwandflächen wurden definierte Betonfeuchten eingestellt. Die Applikation der beiden Systeme (RPS-B, RPS-R) wurde jeweils mit bzw. ohne Primer ausgeführt, der Primer wurde aufgerollt. Parallel zu den Untersuchungen an den Musterflächen 1 Products Fig. 4 CO2-blasted concrete surface. Fig. 6 Hardware technology for polyurea coatings. Abb. 4 CO2-gestrahlte Betonoberfläche. Abb. 6 Gerätetechnik für Polyurea-Beschichtungen. Fig. 5 Adjustment of concrete moisture by airless means (right) and primers of the preparated wall surfaces (left). Fig. 7 Sample slabs coated in a field test. Abb. 5 Einstellen der Betonfeuchte mittels Airlessgerätes (rechts) und Primern der vorbehandelten Wandflächen (links). allel to the investigations of the sample areas in the digestion tank, laboratory tests were conducted on so-called composite bodies, i.e. concrete slabs of strength C 30/37 coated on site. Apart from the parameters of moisture, materials system and primer, the temperatures of the substrates were adjusted in the area of –12 °C to +40 °C. The hardware technology used and the coating procedure are presented in Fig. 6 to Fig. 8. Figure 9 illustrates the preparation of the pull-off tests on the wall surfaces of the digestion tank provided with different coatings. The coatings were applied by specialized companies. Sample surface testing was accompanied by further extensive quality tests (e.g. bond strength, visual changes such as color changes, crack and bubble formation). As a supplement to the in-situ investigations of the composite samples (24 basic variants), cyclic exposure to the loads of climate and media were performed in accelerated tests. As a principal parameter for assessing the serviceability of the system, pull-off tests were carried out to establish the bond strength. Fig. 9 Determination of the adhesive tensile strength values on the wall surfaces of the digestion tank provided with different coatings. Abb. 9 Ermittlung der Haftzugfestigkeitswerte an unterschiedlich beschichteten Wandflächen des Faulbehälters. 58 Abb. 7 Beschichtung von Probeplatten im Feldversuch. Fig. 8 Polyurea coating of sample areas in the digestion tank. Abb. 8 Polyurea-Beschichtung von Musterflächen im Faulbehälter. im Faulbehälter erfolgten Laboruntersuchungen an so genannten Verbundkörpern, dass heißt vor Ort beschichteten Betonplatten der Festigkeit C 30/37. Neben den Parametern Feuchte, Materialsystem und Primer wurden Untergrundtemperaturen im Bereich –12 °C bis +40 °C eingestellt. Die verwendete Gerätetechnik und der Beschichtungsablauf sind in den Abb. 6 bis Abb. 8 dargestellt. Die Abb. 9 zeigt die Vorbereitung der Haftverbundprüfungen an den unterschiedlich beschichteten Wandflächen des Faulbehälters. Die Ausführungen der Beschichtungen erfolgten durch Fachfirmen. Die Musterflächen wurden über einen Zeitraum von zwölf Monaten durch Qualitätsprüfungen (z. B. Haftverbund, visuelle Veränderungen wie Farbänderung, Riss- und Blasenbildungen) wissenschaftlich begleitet. Als Ergänzung zu den Vor-Ort-Untersuchungen wurBFT 12/2006 Produkte 1 Fig. 10 Adhesive tensile strength values after one year of real-time loading depending on materials system (RPS-B, RPS-R, with/without primer) and preparation of substrate. Abb. 10 Haftzugfestigkeitswerte nach einjähriger Echtzeitbelastung in Abhängigkeit von Materialsystem (RPS-B, RPS-R, mit/ohne Primer) und Untergrundvorbehandlung. Legend/Legende CO Dry ice blasting Trockeneisstrahlen HD High-pressure water jet Wasserhochdruckstrahlen FS Sand/shotblasting Feststoffstrahlen F/T Surface moist/dry Oberfläche Feucht/Trocken Value element Zahl Element First results of the investigation For the model project “rehabilitation of digestive tanks” only tendential estimations on the suitability of these polyurea coatings can currently be made. The adhesive tensile strength values recorded after one year of real time loading are contained in Fig. 10. The results of the investigation so far basically confirm that the durability/tightness of sewage structures with high chemical loads can be reinstated with polyurea spray elastomers. In this case polyurea coatings are an alternative to traditional coating materials based on polymer-modified mineral mortars and synthetic resin coatings for tanks of complex geometry (changes in level, pipe culverts, edges and projections), damp substrates and/or increased air humidities. Additionally, the main argument for the use of polyurea coatings are the very short hardening times, which allow the tanks to be put back into operation after only two hours. The results gained so far from the ongoing materials investigations are: 1. As cleaning systems for a sufficiently loadbearing concrete base, both sand/shotblasting, high-pressure water jet and CO2 blasting are suitable. The highest adhesive tensile strengths values, however, are achieved with sand/shotblasting. If the removal of concrete down to a sufficiently loadbearing layer is necessary, this result can only be achieved by means of sand/shotblasting. 2. The use of primers is absolutely necessary to achieve the minimum required adhesive tensile strength values of all existent substrates of concrete. 3. Sufficient adhesive tensile strengths are still BFT 12/2006 den an Verbundkörpern (24 Grundvarianten) zyklische Klima- und Medienbelastungen im Zeitraffertest durchgeführt. Als Hauptparameter zur Beurteilung der Gebrauchstauglichkeit wurde die Haftzugfestigkeit herangezogen. Erste Untersuchungsergebnisse Für das Modellprojekt „Instandsetzung Faulbehälter“ können derzeit nur tendenzielle Einschätzungen zur Eignung dieser Polyurea-Beschichtungen abgegeben werden. Die Haftzugfestigkeitswerte nach einjähriger Echtzeitbelastung sind in Abb. 10 enthalten. Grundsätzlich bestätigen die Untersuchungen, dass mit Polyurea-Sprühelastomeren die Dauerhaftigkeit/ Dichtigkeit von Abwasserbauwerken bei sehr starkem chemischem Angriff wiederhergestellt werden kann. Polyurea-Beschichtungen stellen dort eine Alternative zu traditionellen Beschichtungsmaterialien auf der Basis von kunststoffmodifizierten mineralischen Mörteln und Kunstharzbeschichtungen dar, wo schwierige Behältergeometrien (Ebenenwechsel, Rohrdurchführungen, Kanten, Vorsprünge), feuchte Betonuntergründe und/oder erhöhte Luftfeuchtigkeiten vorliegen. Zusätzlich liegt das Hauptargument für den Einsatz von Polyurea-Beschichtungen in den sehr kurzen Aushärtungszeiten, da die Behälter bereits nach zwei Stunden wieder in Betrieb genommen werden können. Bisherige Ergebnisse der laufenden Materialuntersuchungen sind: 1. Als Reinigungsverfahren für eine ausreichend tragfähige Betonunterlage sind sowohl Feststoffstrahlen, Hochdruckwasserstrahlen als auch CO2-Strah- 59 1 Products achieved with slightly damp concrete substrates (moisture content of up to 5 M.-%). 4. The layer thicknesses for target layer thicknesses of 2.5 mm range between 1.3 and 3.2 mm. The target layer thickness is deemed to be attained when 80% of the measured values deviate by no more than 20%. The results achieved confirm that the requirements imposed on the expertise and the experience of the nozzle operator are especially demanding for coating systems of this kind. 5. Spray shadows and spray fog droplets should be avoided and can be greatly influenced by the way in which the nozzle is operated. 6. Cavities and detachments were detected only where the concrete substrates ensured no sufficient bond with regard to the pull-off strength and/or where no primer was used. 7. When subjected to freeze-thaw cycling (–20 °C/ +20 °C), losses in adhesive tensile strength of 5 to 30% are recorded. Bond failures due to the load of climate changes can, however, be significantly reduced by preparing the substrate by means of sand/ shotblasting and by the use of primers. 8. In the presence of pressurized and non-pressurized moisture penetration from the backside, no detachments/cavities were evidenced. Osmotic damage mechanisms were not detected. 9. The media resistance was confirmed by submersion tests in water and diluted sulfuric acid. Polyurea spray elastomer coatings place high demands on the planning and execution of rehabilitation measures and require detailed steps for quality assurance (control of the execution on location). Polyurea coatings – when properly executed within the scope of a rehabilitation scheme – provide an alternative to traditional coating materials; in particular for sewer structures of complex geometry exposed to highly aggressive environments, very damp concrete substrates and high air humidities. References/Literatur 60 [1] Stein, D.: Instandhaltung von Kanalisationen; Verlag Ernst Sohn Berlin, 3. Auflage 1999 [2] Kämpfer, W.; Dimmig, A.; Stark, J.: Beständigkeit von kunststoffmodifizierten Sielbaumörteln gegenüber mechanischchemischen Belastungen; 15. Internationale Baustofftagung; Bauhaus-Universität Weimar, pp 1309; 2003 [3] Tripp, I.: Polyurea – Hydrogen Sulfide Resistant Industrial Sewage & Wastewater Coating for Rehabilitation of Concrete; Elastomer Specialities, Inc.; Madison USA; 2005 [4] STB – Produkte mit Zukunft; Präsentation PRS GmbH Schkeuditz, September 2004 [5] Broekaert; M.: New emulsifiable MDI-variants for sealers and primers on dry and wet concrete; Application and Product Development Manager – Coatings; Huntsman Polyurethanes; Everberg, Belgium; 01-2004 [6] Schmitz, J.: Aliphatische Polyisocyanate: Vom Standard HDIBiuret zu speziellen Härtern für Wasserlacke, High Solids oder schnelltrocknende 2K PUR Systeme; Bayer MaterialScience Leverkusen; 2005 [7] Bossler, B.; Puhl, R.: Beschichtungsverfahren zur Sanierung von Abwasserschächten; Kurzbericht IKT-Institut für unterirdische Infrastruktur; Februar 2005 len geeignet. Die höchsten Haftzugwerte werden jedoch mit dem Feststoffstrahlen erreicht. Ist der Abtrag des Betons bis in eine ausreichend tragfähige Schicht notwendig, dann ist dies ebenfalls nur mittels Feststoffstrahlens zu erzielen. 2. Der Einsatz von Primern ist zwingend notwendig, um die geforderten Mindesthaftzugfestigkeitswerte für die meist vorliegenden unterschiedlichen Betonuntergründe zu garantieren. 3. Auch bei mattfeuchten Betonuntergründen (Feuchtegehalt bis 5 M.-%) werden noch ausreichende Haftzugfestigkeiten gewährleistet. 4. Die Schichtdicken variieren bei einer geforderten Sollschichtdicke von 2,5 mm zwischen 1,3 und 3,2 mm. Die Sollschichtdicke gilt als erreicht, wenn 80 % der Messwerte um nicht mehr als 20 % abweichen. Die erhaltenen Resultate belegen, dass die Anforderungen an die Qualifikation und die Erfahrungen des Düsenführers für die Qualität derartiger Beschichtungssysteme besonders hoch sind. 5. Spritzschatten und Sprühnebeltröpfchen sollten vermieden werden und können durch die Düsenführung maßgeblich beeinflusst werden. 6. Hohlstellen und Ablösungen wurden nur dort detektiert, wo die Betonuntergründe keinen ausreichenden Haftverbund gewährleisten hinsichtlich der Abreißfestigkeit bzw. wo kein Primer eingesetzt wurde. 7. Unter Frost-Tau-Wechselbelastungen (–20 °C/+20 °C) sind Rückgänge der Haftzugfestigkeiten von 5 bis 30 % zu verzeichnen. Durch die Vorbereitung des Untergrundes mittels Feststoffstrahlen und den Einsatz von Primern können Verbundstörungen bei Klimawechselbelastungen jedoch erheblich reduziert werden. 8. Bei drückender und druckloser rückwärtiger Durchfeuchtung wurden keine Ablösungen/Hohlstellen festgestellt. Osmotische Schädigungsmechanismen wurden nicht detektiert. 9. Die Medienbeständigkeit wurde durch Einlagerungsversuche in Wasser und verdünnter Schwefelsäure nachgewiesen. Beschichtungen mit Polyurea-Sprühelastomeren stellen hohe Anforderungen an die Sanierungsplanung und -ausführung. Sie erfordern detaillierte Maßnahmen zur Qualitätssicherung (Kontrolle der Bauausführung). Bei ordnungsgemäßer Ausführung der Sanierungen stellen Polyurea-Beschichtungen insbesondere für hoch belastete Abwasserbauwerke mit schwieriger Behältergeometrie, hohen Beton- und Luftfeuchtigkeiten eine Alternative zu traditionellen Beschichtungen dar. Andrea Dimmig-Osburg, Wolfram Kämpfer, Pattrick Beck BFT 12/2006