TECHNICAL SPECIFICATION
Transcrição
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION F899P0001 / F899P0002 Switch Probe 354 mil, Pneumatic, OFF-ON-OFF Center (mm/mil) 10,00 / 394 Current 3,0 A Current (Switch) 1,0 A Temperature -20°C...+80°C R typically 100 mOhm Technical Specification Operating pressure Operating medium Allowed leakage rate Thread (M) 5-7 bar rate of change 75cN / bar compressed air (dry & filtered) 2100782 Pneumatic tube 5 cm³/min. 8,0x1,0 Working Travel [mm] Switch point 1 2,0 ±0,2 Nominal travel 3,8 Switch point 2 4,0 ±0,2 Max. travel 5,2 Contact Force at 6 bar [cN] Working Travel [mm] Switch point 1 3,0 ±0,2 Nominal travel 3,8 Switch point 2 4,0 ±0,2 Max. travel 5,2 Contact Force at 6 bar [cN] F899P0001 F899P0002 350 ±20% 350 ±20% Materials and Plating Contact head Barrel Spring Receptacle 2104456 Connecting cable AWG 21 (0,25mm²) PVC coated Length 550 mm Synthetic, unplated Brass, gold plated Synthetic, unplated Music wire, silver plated Brass, nickel plated The pneumatic mikro switch probe F899P with off-on-off charakteristic can be used for position tests at limited space. Switch characteristic 1x F899P0001 Pneum. mikro switch 2x 2104456 Connecting cable (AWG21) Accessories Pneumatic tube Receptacle with knurl Screw-in tool (probe) 2100782 (NW2) H899RD FWZ899T Drill Size (mm) Receptacle with knurl 9,02 - 9,06 switching status 1 Included in Delivery F899P0001 F899P0002 0 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 travel [mm] To use the probe faultless, please note the following mounting- and handling information. Stand 05/2016. Änderungen vorbehalten. Nicht alle Kombinationen sind verfügbar. Weitere Varianten finden Sie unter www.feinmetall.de MOUNTING- AND HANDLING F899P Drilling recommendation for use without receptacle For mounting the F899P without receptacle and holding it in position, an accurately bore is necessary. If the modul has to be airtight, the bore needs to be especially accurate. The exact drill sizes depend on the material. These drilling recommendations are guideline values. The maximum allowed leakage rate is 5cm³/min. Screw-In-Tool FWZ899T The mounting tool fits into the provided slots. This allows to screw in and adjust the probe from backwards. FWZ899T GS500T BIT899 Adjustability in Longitudinal Direction The probe F899P can be mounted in a fixed position on stop, or adjusted up to 2,0mm by the threaded design of the probe. One rotation leads to 1,0mm longitudinal shift. Stand 05/2016. Änderungen vorbehalten. Nicht alle Kombinationen sind verfügbar. Weitere Varianten finden Sie unter www.feinmetall.de mounting direction