TECHNICAL SPECIFICATION

Transcrição

TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION
F899P0001 / F899P0002
Switch Probe 354 mil,
Pneumatic,
OFF-ON-OFF
Center (mm/mil)
10,00 / 394
Current
3,0 A
Current (Switch)
1,0 A
Temperature
-20°C...+80°C
R typically
100 mOhm
Technical Specification
Operating
pressure
Operating
medium
Allowed
leakage rate
Thread (M)
5-7 bar
rate of change 75cN / bar
compressed air
(dry & filtered)
2100782
Pneumatic tube
5 cm³/min.
8,0x1,0
Working
Travel [mm]
Switch point 1 2,0 ±0,2
Nominal travel 3,8
Switch point 2 4,0 ±0,2
Max. travel
5,2
Contact Force
at 6 bar [cN]
Working
Travel [mm]
Switch point 1 3,0 ±0,2
Nominal travel 3,8
Switch point 2 4,0 ±0,2
Max. travel
5,2
Contact Force
at 6 bar [cN]
F899P0001
F899P0002
350 ±20%
350 ±20%
Materials and Plating
Contact head
Barrel
Spring
Receptacle
2104456
Connecting cable
AWG 21 (0,25mm²)
PVC coated
Length 550 mm
Synthetic, unplated
Brass, gold plated
Synthetic, unplated
Music wire, silver plated
Brass, nickel plated
The pneumatic mikro switch probe F899P with off-on-off charakteristic can be used for
position tests at limited space.
Switch characteristic
1x F899P0001 Pneum. mikro switch
2x 2104456 Connecting cable (AWG21)
Accessories
Pneumatic tube
Receptacle with knurl
Screw-in tool (probe)
2100782
(NW2)
H899RD
FWZ899T
Drill Size (mm)
Receptacle with knurl
9,02 - 9,06
switching status
1
Included in Delivery
F899P0001
F899P0002
0
0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0
travel [mm]
To use the probe faultless, please note the following mounting- and handling
information.
Stand 05/2016. Änderungen vorbehalten. Nicht alle Kombinationen sind verfügbar. Weitere Varianten finden Sie unter www.feinmetall.de
MOUNTING- AND HANDLING F899P
Drilling recommendation
for use without receptacle
For mounting the F899P without
receptacle and holding it in position,
an accurately bore is necessary.
If the modul has to be airtight, the
bore needs to be especially accurate.
The exact drill sizes depend on the
material. These drilling recommendations are guideline values.
The maximum allowed leakage rate
is 5cm³/min.
Screw-In-Tool FWZ899T
The mounting tool fits into the
provided slots. This allows to screw in
and adjust the probe from backwards.
FWZ899T
GS500T
BIT899
Adjustability in
Longitudinal Direction
The probe F899P can be mounted in a
fixed position on stop, or adjusted up
to 2,0mm by the threaded design of
the probe. One rotation leads to
1,0mm longitudinal shift.
Stand 05/2016. Änderungen vorbehalten. Nicht alle Kombinationen sind verfügbar. Weitere Varianten finden Sie unter www.feinmetall.de
mounting
direction